Home/Catalog/EATON-OIDS

EATON-OIDS

AI MIB Summary

The EATON-OIDS MIB module defines the root OID branch (1.3.6.1.4.1.534) that serves as the namespace foundation for all Eaton power management devices, including UPS systems, power distribution units, and environmental monitoring sensors. This module enables network management systems to locate and retrieve specific operational metrics such as battery status, load levels, input/output voltage, and temperature readings from Eaton hardware.

Assigns major branches from the root of Eaton's OID tree (534). Copyright (C) Exide Electronics 1992-98 Copyright (C) Powerware Corporation 1999-2004 Copyright (C) Eaton Corporation (2005-).
Main OID:
eaton.1.3.6.1.4.1.534
29
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

29 total
Object Name
eatonAssigns major branches from the root of Eaton's OID tree (534). Copyright (C) Exide Electronics 1992-98 Copyright (C) Powerware Corporation 1999-2004 Copyright (C) Eaton Corporation (2005-).
MODULE-IDENTITY
.1.3.6.1.4.1.534
xupsMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.1
xupsEnvironment
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.1.6
xupsObjectId
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2
powerwareEthernetSnmpAdapter
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.1
powerwareNetworkSnmpAdapterEther
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.2
powerwareNetworkSnmpAdapterToken
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.3
onlinetDaemon
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.4
connectUPSAdapterEthernet
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.5
powerwareNetworkDigitalIOEther
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.6
connectUPSAdapterTokenRing
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.7
simpleSnmpAdapter
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.8
powerwareEliSnmpAdapter
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.9
powerwareBasicEmbeddedEthernet
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.10
eatonPowerChainGateway
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.11
eatonPowerChainDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.12
eatonPowerXpertMeter
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.2.13
xupsIoMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.3
powerVision
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.4
products
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6
pduAgent
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6
hdpdu
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6.2
eatonPdu
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6.4
dataCenter
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.7
environmentalMonitor
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.7.1
itProjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.7
pki
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.7.1
powerChain
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.8
powerCmnd
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.9

More MIBs from Eaton

Browse all EatonMIBs →
XUPS-MIB

Standard SNMP MIB module defining data structures for XUPS-MIB.

265 objects→
EATON-EPDU-MIB

The EATON-EPDU-MIB enables SNMP-based monitoring and management of Eaton Enclosure Power Distribution Units, providing granular access to real-time electrical metrics including voltage, current, power consumption, and outlet-level status. This module facilitates precise remote control of individual PDU outlets and the collection of environmental data such as temperature and humidity for infrastructure capacity planning and fault detection.

239 objects→
RackMonitor-MIB

Standard SNMP MIB module defining data structures for RackMonitor-MIB.

176 objects→
EATON-EPDU-MA-MIB

The EATON-EPDU-MA-MIB enables SNMP-based monitoring and control of Eaton Enclosed Power Distribution Units (ePDUs) in managed configurations, exposing critical power metrics such as outlet status, voltage, current, power consumption, and environmental sensor data.

130 objects→
EATON-ATS2-MIB

The EATON-ATS2-MIB enables SNMP-based monitoring and management of Eaton Automatic Transfer Switch (ATS) hardware, providing real-time visibility into critical power status indicators such as source availability, transfer states, and alarm conditions.

103 objects→
EATON-PDU-MIB

The EATON-PDU-MIB enables SNMP-based monitoring and management of Eaton Power Distribution Units, providing access to real-time electrical metrics including voltage, current, power consumption, and outlet-level status. It facilitates granular control over individual PDU outlets and aggregates environmental data such as temperature and humidity for infrastructure capacity planning and fault detection.

94 objects→