Home/Catalog/EATON-EPDU-MA-MIB

EATON-EPDU-MA-MIB

AI MIB Summary

The EATON-EPDU-MA-MIB enables SNMP-based monitoring and control of Eaton Enclosed Power Distribution Units (ePDUs) in managed configurations, exposing critical power metrics such as outlet status, voltage, current, power consumption, and environmental sensor data.

The MIB module for Eaton ePDUs (Enclosed Power Distribution Units) -Managed Model.
Main OID:
eatonEpduMa.1.3.6.1.4.1.534.6.6.6
123
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

123 total
Object Name
eatonEpduMaThe MIB module for Eaton ePDUs (Enclosed Power Distribution Units) -Managed Model.
MODULE-IDENTITY
.1.3.6.1.4.1.534.6.6.6
traps
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6.6.0
rebootStartedThe reboot process has started
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.1
rebootCompletedThe reboot process is complete
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.2
userLoginA user logged in
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.3
userLogoutA user logged out
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.4
userAuthenticationFailureA user authentication attempt failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.5
userSessionTimeoutA user timed out from the device
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.8
userAddedA user was added to the system
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.11
userModifiedA user account was modified
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.12
userDeletedA user was deleted from the system
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.13
groupAddedA group was added to the system
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.14
groupModifiedA group was modified
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.15
groupDeletedA group was deleted from the system
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.16
deviceUpdateStartedThe device update has started
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.20
userBlockedA blocked user tried to log in
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.22
powerControlAn outlet has been switched
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.23
userPasswordChangedA user password was changed
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.24
passwordSettingsChangedStrong password settings changed
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.28
firmwareFileDiscardedA firmware file discarded
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.36
firmwareValidationFailedA firmware validation failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.38
securityViolationSecurity violation.
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.39
logFileClearedThe log file has been cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.41
thresholdAlarmConfigured sensor theshold event. The 'thresholdType' variable will indicate whether or not the threshold triggered or cleared
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.45
outletGroupingConnectivityLostMaster PDU lost contact with the slave PDU in an outlet grouping configuration.
NOTIFICATION-TYPE
.1.3.6.1.4.1.534.6.6.6.0.50
board
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6.6.1
info
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6.6.1.1
firmwareVersionThe current firmware versionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.1
serialNumberThe serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.2
ipAddressThe current IP address. A value of 0.0.0.0 indicates an error or an unset option.ro
IpAddress
.1.3.6.1.4.1.534.6.6.6.1.1.3
netmaskThe current Netmask. A value of 0.0.0.0 indicates an error or an unset option.ro
IpAddress
.1.3.6.1.4.1.534.6.6.6.1.1.4
gatewayThe current Gateway. A value of 0.0.0.0 indicates an error or an unset option.ro
IpAddress
.1.3.6.1.4.1.534.6.6.6.1.1.5
macThe current MAC address.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.6
hardwareRevThe hardware revision number.ro
Integer32
.1.3.6.1.4.1.534.6.6.6.1.1.7
userNameThe login of a user.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.10
objectNameThe model type of the devicero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.12
objectInstanceThe device namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.13
targetUserThe user record being operated onro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.14
groupNameThe group record being operated onro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.15
imageVersionThe version of the Upgrade imagero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.18
sensorDescrSensor description indicating which sensor experienced a threshold exceeded event. When applicable the description will indicate the sensor number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.19
thresholdDescrThreshold description indicating which configured threshold has been triggered (or cleared).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.20
thresholdSeverityString (Warning, Critical, etc...) indicating the severity of the threshold which has been triggered (or cleared).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.21
thresholdEventTypeString (triggered, cleared) indicating if the threshold event indicates that a configured threshold has been triggered or cleared.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.22
statusThe success status of an operationro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.1.23
slaveIpAddressIn a shepherding configuration, this is the IP address of slave PDU. A value of 0.0.0.0 indicates an error or an unset option.ro
IpAddress
.1.3.6.1.4.1.534.6.6.6.1.1.24
outlets
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6.6.1.2
outletCountThe number of outlets (regardless of their current state) present on this pdu.ro
Integer32
.1.3.6.1.4.1.534.6.6.6.1.2.1
outletTableA list of outlet entries. The number of entries is given by the value of outletCount.
SEQUENCE OF OutletEntryStruct
.1.3.6.1.4.1.534.6.6.6.1.2.2
outletEntryAn outlet entry containing objects at the for a particular outlet.
OutletEntryStruct
.1.3.6.1.4.1.534.6.6.6.1.2.2.1
outletIndexA unique value for each outlet. Its value ranges between 1 and the value of outletCount.
Integer32
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.1
outletLabelA textual string containing information about the outlet.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.2
outletOperationalStateA value for each outlet which describes the operational state of the outlet. It is also used to set the operational state of the outletrw
Enumeration
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.3
outletCurrentA unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp)ro
MilliAmps
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.4
outletMaxCurrentA unique value for the max. current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp)ro
MilliAmps
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.5
outletVoltageA unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt)ro
MilliVolts
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.6
outletActivePowerA unique value for the active power sensor attached to the outlet. This value is reported in Watts.ro
Watts
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.7
outletApparentPowerA unique value for the apparent power sensor attached to the outlet. This value is reported in Volt-Ampsro
VoltAmps
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.8
outletPowerFactorA unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%.ro
PowerFactorPercentage
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.9
outletCurrentUpperWarningThe value of the upper warning (non-critical) current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp)rw
MilliAmps
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.21
outletCurrentUpperCriticalThe value of the upper critical current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp)rw
MilliAmps
.1.3.6.1.4.1.534.6.6.6.1.2.2.1.23
unit
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6.6.1.3
unitReadings
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6.6.1.3.1
unitCurrentThe value for the unit's current sensor in millamps.ro
MilliAmps
.1.3.6.1.4.1.534.6.6.6.1.3.1.1
unitVoltageThe value for the unit's voltage sensor in millivolts.ro
MilliVolts
.1.3.6.1.4.1.534.6.6.6.1.3.1.2
unitActivePowerThe value for the unit's voltage sensor in volt-amps.ro
Watts
.1.3.6.1.4.1.534.6.6.6.1.3.1.3
unitApparentPowerThe value for the unit's voltage sensor in volt-amps.ro
Watts
.1.3.6.1.4.1.534.6.6.6.1.3.1.4
unitCpuTempThe value for the unit's CPU temperature sensor in degrees Celsius.ro
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.1.3.1.5
unitCircuitBreak0StateThe value for the unit's circuit breaker state sensor 0.ro
Enumeration
.1.3.6.1.4.1.534.6.6.6.1.3.1.20
unitCircuitBreak1StateThe value for the unit's circuit breaker state sensor 1.ro
Enumeration
.1.3.6.1.4.1.534.6.6.6.1.3.1.21
unitCircuitBreak2StateThe value for the unit's circuit breaker state sensor 2.ro
Enumeration
.1.3.6.1.4.1.534.6.6.6.1.3.1.22
unitCircuitBreak0CurrentThe value for the unit's circuit breaker current sensor 0.ro
MilliAmps
.1.3.6.1.4.1.534.6.6.6.1.3.1.40
unitCircuitBreak1CurrentThe value for the unit's circuit breaker current sensor 1.ro
MilliAmps
.1.3.6.1.4.1.534.6.6.6.1.3.1.41
unitCircuitBreak2CurrentThe value for the unit's circuit breaker current sensor 2.ro
MilliAmps
.1.3.6.1.4.1.534.6.6.6.1.3.1.42
unitVoltageLowerWarningThe value of the lower warning (non-critical) unit level voltage threshold.rw
MilliVolts
.1.3.6.1.4.1.534.6.6.6.1.3.1.60
unitVoltageLowerCriticalThe value of the lower critical unit level voltage threshold.rw
MilliVolts
.1.3.6.1.4.1.534.6.6.6.1.3.1.61
unitVoltageUpperWarningThe value of the upper warning (non-critical) unit level voltage threshold.rw
MilliVolts
.1.3.6.1.4.1.534.6.6.6.1.3.1.62
unitVoltageUpperCriticalThe value of the upper critical unit level voltage threshold.rw
MilliVolts
.1.3.6.1.4.1.534.6.6.6.1.3.1.63
unitCurrentUpperWarningThe value of the upper warning (non-critical) unit level current threshold.rw
MilliAmps
.1.3.6.1.4.1.534.6.6.6.1.3.1.70
unitCurrentUpperCriticalThe value of the upper critical unit level current threshold. NOTE: This particular threshold is NOT settablero
MilliAmps
.1.3.6.1.4.1.534.6.6.6.1.3.1.71
unitTempLowerWarningThe value of the lower warning (non-critical) unit level temperature threshold.rw
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.1.3.1.80
unitTempLowerCriticalThe value of the lower critical unit level temperature threshold.rw
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.1.3.1.81
unitTempUpperWarningThe value of the upper warning (non-critical) unit level temperature threshold.rw
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.1.3.1.82
unitTempUpperCriticalThe value of the upper critical unit level temperature threshold.rw
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.1.3.1.83
environmental
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6.6.2
tempSensorCountThe number of external temperature sensors (regardless of their current state) present on this pdu.ro
Integer32
.1.3.6.1.4.1.534.6.6.6.2.1
tempSensorTableA list of temperature sensor entries. The number of entries is given by the value of tempSensorCount.
SEQUENCE OF TempSensorEntryStruct
.1.3.6.1.4.1.534.6.6.6.2.2
tempSensorEntryAn entry containing sensor reading and threshold settings for a particular temperature sensor.
TempSensorEntryStruct
.1.3.6.1.4.1.534.6.6.6.2.2.1
tempSensorIndexA unique value for each temperature sensor. Its value ranges between 1 and tempSensorCount.
Integer32
.1.3.6.1.4.1.534.6.6.6.2.2.1.1
tempSensorLabelA settable human-readable label for the external temperature sensor. One possible use for this label is to convey sensor location.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.2.2.1.2
temperatureThe value of the external temperature sensor reported in degrees celsius.ro
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.2.2.1.3
tempLowerWarningThe value of the lower warning (non-critical) threshold.rw
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.2.2.1.4
tempUpperWarningThe value of the upper warning (non-critical) threshold.rw
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.2.2.1.5
tempLowerCriticalThe value of the lower critical threshold.rw
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.2.2.1.6
tempUpperCriticalThe value of the upper critical threshold.rw
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.2.2.1.7
tempLowerWarningResetThe value of the lower warning (non-critical) reset/hysteresis value.rw
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.2.2.1.8
tempUpperWarningResetThe value of the upper warning (non-critical) reset/hysteresis value.rw
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.2.2.1.9
tempLowerCriticalResetThe value of the lower critical reset/hysteresis value.rw
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.2.2.1.10
tempUpperCriticalResetThe value of the upper critical reset/hysteresis value.rw
DegreesCelsius
.1.3.6.1.4.1.534.6.6.6.2.2.1.11
humiditySensorCountThe number of external humidity sensors (regardless of their current state) present on this pdu.ro
Integer32
.1.3.6.1.4.1.534.6.6.6.2.3
humiditySensorTableA list of humidity sensor entries. The number of entries is given by the value of humiditySensorCount.
SEQUENCE OF HumiditySensorEntryStruct
.1.3.6.1.4.1.534.6.6.6.2.4
humiditySensorEntryAn entry containing sensor reading and threshold settings for a particular humidity sensor.
HumiditySensorEntryStruct
.1.3.6.1.4.1.534.6.6.6.2.4.1
humiditySensorIndexA unique value for each humidity sensor. Its value ranges between 1 and humiditySensorCount.
Integer32
.1.3.6.1.4.1.534.6.6.6.2.4.1.1
humiditySensorLabelA settable human-readable label for the external humidity sensor. One possible use for this label is to convey sensor location.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.534.6.6.6.2.4.1.2
humidityThe value of the external humidity sensor reported as relative humidity (a percentage).ro
RelativeHumidity
.1.3.6.1.4.1.534.6.6.6.2.4.1.3
humidityLowerWarningThe value of the lower warning (non-critical) threshold.rw
RelativeHumidity
.1.3.6.1.4.1.534.6.6.6.2.4.1.4
humidityUpperWarningThe value of the upper warning (non-critical) threshold.rw
RelativeHumidity
.1.3.6.1.4.1.534.6.6.6.2.4.1.5
humidityLowerCriticalThe value of the lower critical threshold.rw
RelativeHumidity
.1.3.6.1.4.1.534.6.6.6.2.4.1.6
humidityUpperCriticalThe value of the upper critical threshold.rw
RelativeHumidity
.1.3.6.1.4.1.534.6.6.6.2.4.1.7
humidityLowerWarningResetThe value of the lower warning (non-critical) reset/hysteresis value.rw
RelativeHumidity
.1.3.6.1.4.1.534.6.6.6.2.4.1.8
humidityUpperWarningResetThe value of the upper warning (non-critical) reset/hysteresis value.rw
RelativeHumidity
.1.3.6.1.4.1.534.6.6.6.2.4.1.9
humidityLowerCriticalResetThe value of the lower critical reset/hysteresis value.rw
RelativeHumidity
.1.3.6.1.4.1.534.6.6.6.2.4.1.10
humidityUpperCriticalResetThe value of the upper critical reset/hysteresis value.rw
RelativeHumidity
.1.3.6.1.4.1.534.6.6.6.2.4.1.11
conformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6.6.9
compliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6.6.9.1
complianceThe requirements for conformance to the PDU-MIB.
Unknown
.1.3.6.1.4.1.534.6.6.6.9.1.1
groups
OBJECT IDENTIFIER
.1.3.6.1.4.1.534.6.6.6.9.2
infoGroupA collection of objects providing basic information about the pdu.
Unknown
.1.3.6.1.4.1.534.6.6.6.9.2.1
outletsGroupA collection of objects providing basic information about the outlets, including sensor readings.
Unknown
.1.3.6.1.4.1.534.6.6.6.9.2.2
unitSensorsGroupA collection of objects providing unit level sensor readings.
Unknown
.1.3.6.1.4.1.534.6.6.6.9.2.4
externalTemperatureGroupA collection of objects providing external temperature sensor readings and threshold settings.
Unknown
.1.3.6.1.4.1.534.6.6.6.9.2.6
externalHumidityGroupA collection of objects providing external humidity sensor readings and threshold settings.
Unknown
.1.3.6.1.4.1.534.6.6.6.9.2.7
trapsGroupA collection of traps.
Unknown
.1.3.6.1.4.1.534.6.6.6.9.2.9
EATON-EPDU-MA-MIB - SNMP MIB Reference | MIBs Explorer