30 total| Object Name |
|---|
rlLan1 MODULE-IDENTITY .1.3.6.1.4.1.9.6.1.101.224 |
rlLan1STagEtherTyperw OCTET STRING .1.3.6.1.4.1.9.6.1.101.224.1 |
rlLan1CPVlanIdrw VlanIdOrNone .1.3.6.1.4.1.9.6.1.101.224.2 |
rlLan1CPVlanCosrw INTEGER .1.3.6.1.4.1.9.6.1.101.224.3 |
rlLan1x86Portrw INTEGER .1.3.6.1.4.1.9.6.1.101.224.4 |
rlLan1x86VlanMappingTable SEQUENCE OF RlLan1x86VlanMappingEntry .1.3.6.1.4.1.9.6.1.101.224.5 |
rlLan1x86VlanMappingEntry RlLan1x86VlanMappingEntry .1.3.6.1.4.1.9.6.1.101.224.5.1 |
rlLan1x86VlanMappingVlanId VlanId (Q-BRIDGE-MIB) .1.3.6.1.4.1.9.6.1.101.224.5.1.1 |
rlLan1x86VlanMappingGroupIdrw GroupId .1.3.6.1.4.1.9.6.1.101.224.5.1.2 |
rlLan1x86VlanMappingRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.224.5.1.3 |
rlLan1VfMacMappingTable SEQUENCE OF RlLan1VfMacMappingEntry .1.3.6.1.4.1.9.6.1.101.224.6 |
rlLan1VfMacMappingEntry RlLan1VfMacMappingEntry .1.3.6.1.4.1.9.6.1.101.224.6.1 |
rlLan1VfMacMappingDstMacAddress MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.224.6.1.1 |
rlLan1VfMacMappingVlanIdrw VlanId (Q-BRIDGE-MIB) .1.3.6.1.4.1.9.6.1.101.224.6.1.2 |
rlLan1VfMacMappingMulticastrw Enumeration .1.3.6.1.4.1.9.6.1.101.224.6.1.3 |
rlLan1VfMacMappingRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.224.6.1.4 |
rlLan1ModulePortTable SEQUENCE OF RlLan1ModulePortEntry .1.3.6.1.4.1.9.6.1.101.224.7 |
rlLan1ModulePortEntry RlLan1ModulePortEntry .1.3.6.1.4.1.9.6.1.101.224.7.1 |
rlLan1ModulePortIfIndex INTEGER .1.3.6.1.4.1.9.6.1.101.224.7.1.1 |
rlLan1ModulePortCPAllowedrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.224.7.1.2 |
rlLan1ModulePortMulticastBroadcastAllowedVlanrw Enumeration .1.3.6.1.4.1.9.6.1.101.224.7.1.3 |
rlLan1ModulePortIngressGroupIdrw GroupId .1.3.6.1.4.1.9.6.1.101.224.7.1.4 |
rlLan1ModulePortEgressGroupIdListrw GroupIdList .1.3.6.1.4.1.9.6.1.101.224.7.1.5 |
rlLan1ModulePortRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.224.7.1.6 |
rlLan1x86PfcTable SEQUENCE OF RlLan1x86PfcEntry .1.3.6.1.4.1.9.6.1.101.224.8 |
rlLan1x86PfcEntry RlLan1x86PfcEntry .1.3.6.1.4.1.9.6.1.101.224.8.1 |
rlLan1x86PriorityIndex INTEGER .1.3.6.1.4.1.9.6.1.101.224.8.1.1 |
rlLan1x86PriorityIsLossyrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.224.8.1.2 |
rlLan1x86PriorityXoffThresholdrw INTEGER .1.3.6.1.4.1.9.6.1.101.224.8.1.3 |
rlLan1x86PriorityXonThresholdrw INTEGER .1.3.6.1.4.1.9.6.1.101.224.8.1.4 |
CISCOSBLAN1-MIB Technical Reference Overview
The CISCOSBLAN1-MIB SNMP MIB module published by Cisco defines 30 managed OID objects, including 21 scalar/column metrics, 4 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.6.1.101.224. Key tabular structures include rlLan1x86VlanMappingTable, rlLan1VfMacMappingTable, rlLan1ModulePortTable, rlLan1x86PfcTable.
Key OID Definitions in CISCOSBLAN1-MIB
.1.3.6.1.4.1.9.6.1.101.224The Lan1 MIB module for supporting Lan1 fetaure.
.1.3.6.1.4.1.9.6.1.101.224.5A table that contains information mapping s-tag to group id.
.1.3.6.1.4.1.9.6.1.101.224.6A table that contains information mapping Mac to s-tag.
.1.3.6.1.4.1.9.6.1.101.224.7A table that contains information on a LAN1 module port.
.1.3.6.1.4.1.9.6.1.101.224.8A table that contains information on a LAN1 x86 port PFC configuration per priority.
.1.3.6.1.4.1.9.6.1.101.224.1Specifies the Ethernet type identifying the S-VLAN tag.
.1.3.6.1.4.1.9.6.1.101.224.2Specifies the CP VLAN ID. 0 indicateds no CP vlan.
.1.3.6.1.4.1.9.6.1.101.224.3Specifies the cos assigned to ingress traffic on module ports into the CP VLAN.
.1.3.6.1.4.1.9.6.1.101.224.4Specifies the interface-id of the Ethernet port connecting LAN1 to the x86 environment implementing Virtual Functions (VFs). 0 indicateds no x86 port defined.
.1.3.6.1.4.1.9.6.1.101.224.5.1A mapping of incoming s-tag to a group.
.1.3.6.1.4.1.9.6.1.101.224.5.1.1The s-tag to mapped to group
.1.3.6.1.4.1.9.6.1.101.224.5.1.2group for filtering traffic
.1.3.6.1.4.1.9.6.1.101.224.5.1.3This object indicates the status of this entry.
.1.3.6.1.4.1.9.6.1.101.224.6.1A mapping of incoming s-tag to a group.
.1.3.6.1.4.1.9.6.1.101.224.6.1.1destination mac address
.1.3.6.1.4.1.9.6.1.101.224.6.1.2The s-tag
.1.3.6.1.4.1.9.6.1.101.224.6.1.3cp - Specifies the VF which S-VLAN-ID is assigned to multicast/broadcast traffic bridged into the CP VLAN from modules to x86 noncp - Specifies the VF which S-VLAN-ID is assigned to multicast/broadcast traffic
.1.3.6.1.4.1.9.6.1.101.224.6.1.4This object indicates the status of this entry.
.1.3.6.1.4.1.9.6.1.101.224.7.1A mapping of incoming s-tag to a group.
.1.3.6.1.4.1.9.6.1.101.224.7.1.1Specifies the interface-id.
.1.3.6.1.4.1.9.6.1.101.224.7.1.2Specifies that CP traffic is allowed on the port, it is used to allow CP multicast/broadcast traffic.
.1.3.6.1.4.1.9.6.1.101.224.7.1.3Specifies that multicast/broadcast traffic is allowed on the CP VLAN or on non-CP VLAN. If the parameter is not configured then only unicast traffic is allowed.
.1.3.6.1.4.1.9.6.1.101.224.7.1.4Specifies the group number assigned to the input frame on the interface
.1.3.6.1.4.1.9.6.1.101.224.7.1.5Specifies the list of egress group numbers
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.