The CISCOSB-STACK-MIB provides private SNMP access to monitor and manage Cisco StackWise stack topology, member device status, and stack-wide operational parameters on Cisco Catalyst switches. It exposes specific metrics including stack member IDs, priority levels, active stack ports, and stack synchronization states to facilitate centralized stack management.
Imported Objects
Objects
26 total| Object Name |
|---|
rlStack MODULE-IDENTITY .1.3.6.1.4.1.9.6.1.101.107 |
rlStackActiveUnitIdTable SEQUENCE OF RlStackActiveUnitIdEntry .1.3.6.1.4.1.9.6.1.101.107.1 |
rlStackActiveUnitIdEntry RlStackActiveUnitIdEntry .1.3.6.1.4.1.9.6.1.101.107.1.1 |
rlStackCurrentUnitId INTEGER .1.3.6.1.4.1.9.6.1.101.107.1.1.1 |
rlStackActiveUnitIdAfterResetrw INTEGER .1.3.6.1.4.1.9.6.1.101.107.1.1.2 |
rlStackUnitModeAfterResetrw Enumeration .1.3.6.1.4.1.9.6.1.101.107.2 |
rlStackUnitModero Enumeration .1.3.6.1.4.1.9.6.1.101.107.3 |
rlStackUnitMacAddressAfterResetrw MacAddress (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.107.4 |
rlStackHybridTable SEQUENCE OF RlStackHybridEntry .1.3.6.1.4.1.9.6.1.101.107.5 |
rlStackHybridEntry RlStackHybridEntry .1.3.6.1.4.1.9.6.1.101.107.5.1 |
rlStackHybridUnitId INTEGER .1.3.6.1.4.1.9.6.1.101.107.5.1.1 |
rlStackHybridStackModero StackMode .1.3.6.1.4.1.9.6.1.101.107.5.1.2 |
rlStackHybridPortsPairro PortsPair .1.3.6.1.4.1.9.6.1.101.107.5.1.3 |
rlStackHybridPortNo1speedro HybridStackPortSpeed .1.3.6.1.4.1.9.6.1.101.107.5.1.4 |
rlStackHybridPortNo2speedro HybridStackPortSpeed .1.3.6.1.4.1.9.6.1.101.107.5.1.5 |
rlStackHybridUnitIdAfterResetrw INTEGER .1.3.6.1.4.1.9.6.1.101.107.5.1.6 |
rlStackHybridStackModeAfterResetrw StackMode .1.3.6.1.4.1.9.6.1.101.107.5.1.7 |
rlStackHybridPortsPairAfterResetrw PortsPair .1.3.6.1.4.1.9.6.1.101.107.5.1.8 |
rlStackHybridPortNo1speedAfterResetrw HybridStackPortSpeed .1.3.6.1.4.1.9.6.1.101.107.5.1.9 |
rlStackHybridPortNo2speedAfterResetrw HybridStackPortSpeed .1.3.6.1.4.1.9.6.1.101.107.5.1.10 |
rlStackHybridDeleteStartupAfterResetro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.6.1.101.107.5.1.11 |
rlStackHybridDeviceModeAfterResetrw HybridStackDeviceMode .1.3.6.1.4.1.9.6.1.101.107.5.1.12 |
rlStackHybridXgPortNo1Numro INTEGER .1.3.6.1.4.1.9.6.1.101.107.5.1.13 |
rlStackHybridXgPortNo1NumAfterResetrw INTEGER .1.3.6.1.4.1.9.6.1.101.107.5.1.14 |
rlStackHybridXgPortNo2Numro INTEGER .1.3.6.1.4.1.9.6.1.101.107.5.1.15 |
rlStackHybridXgPortNo2NumAfterResetrw INTEGER .1.3.6.1.4.1.9.6.1.101.107.5.1.16 |
CISCOSB-STACK-MIB Technical Reference Overview
The CISCOSB-STACK-MIB SNMP MIB module published by Cisco defines 26 managed OID objects, including 21 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.6.1.101.107. Key tabular structures include rlStackActiveUnitIdTable, rlStackHybridTable.
Key OID Definitions in CISCOSB-STACK-MIB
.1.3.6.1.4.1.9.6.1.101.107The private MIB module definition for stack.
.1.3.6.1.4.1.9.6.1.101.107.1The table listing the active unit id of the requested unit.
.1.3.6.1.4.1.9.6.1.101.107.5The table listing information required for hybrid stack.
.1.3.6.1.4.1.9.6.1.101.107.4The MAC address used by this bridge after rest.
.1.3.6.1.4.1.9.6.1.101.107.3show unit type standalone or stack.
.1.3.6.1.4.1.9.6.1.101.107.2set unit type that will be after reset, standalone or stack.
.1.3.6.1.4.1.9.6.1.101.107.1.1.2Indicates the unit id that will be after reset.
.1.3.6.1.4.1.9.6.1.101.107.1.1An entry in the rlStackActiveUnitIdTable.
.1.3.6.1.4.1.9.6.1.101.107.1.1.1The unit number device, which is the active unit id
.1.3.6.1.4.1.9.6.1.101.107.5.1.11Indicates whether the startup configuration is deleted after reset.
.1.3.6.1.4.1.9.6.1.101.107.5.1.12Indicates Device mode (Layer2 or Layer3) after reset.
.1.3.6.1.4.1.9.6.1.101.107.5.1An entry in the rlStackActiveUnitIdTable.
.1.3.6.1.4.1.9.6.1.101.107.5.1.4Indicates the rlStackHybridPortNo1speed.
.1.3.6.1.4.1.9.6.1.101.107.5.1.9Indicates the HybridStackPortSpeed that will be after reset.
.1.3.6.1.4.1.9.6.1.101.107.5.1.5Indicates the rlStackHybridPortNo2speed.
.1.3.6.1.4.1.9.6.1.101.107.5.1.10Indicates the HybridStackPortSpeed that will be after reset.
.1.3.6.1.4.1.9.6.1.101.107.5.1.3Indicates the PortsPair.
.1.3.6.1.4.1.9.6.1.101.107.5.1.8Indicates the PortsPair that will be after reset.
.1.3.6.1.4.1.9.6.1.101.107.5.1.2Indicates the unit stack mode.
.1.3.6.1.4.1.9.6.1.101.107.5.1.7Indicates the unit stack mode that will be after reset.
.1.3.6.1.4.1.9.6.1.101.107.5.1.1The unit number device, which is the active unit id
.1.3.6.1.4.1.9.6.1.101.107.5.1.6Indicates the unit id that will be after reset.
.1.3.6.1.4.1.9.6.1.101.107.5.1.13Indicates the 1st stack cascade active port number.
.1.3.6.1.4.1.9.6.1.101.107.5.1.14Indicates the 1st stack cascade port number that will be after reset.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.