CISCO-SWITCH-NETFLOW-MIB
AI MIB Summary
The CISCO-SWITCH-NETFLOW-MIB enables SNMP-based monitoring of NetFlow export statistics, active flow records, and cache utilization on Cisco Layer 2 and Layer 3 switching platforms. It provides granular visibility into traffic flow metrics, including packet and byte counts, protocol distributions, and flow table occupancy for network capacity planning and security analysis.
This MIB module defines management objects for the Netflow features on Cisco Layer 2 and Layer 3 devices.
Main OID:
ciscoSwitchNetflowMIB.1.3.6.1.4.1.9.9.737
29
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
29 total| Object Name |
|---|
ciscoSwitchNetflowMIBThis MIB module defines management objects for the
Netflow features on Cisco Layer 2 and Layer 3 devices. MODULE-IDENTITY .1.3.6.1.4.1.9.9.737 |
ciscoSwitchNetflowMIBNotifs OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.737.0 |
csnUsageThreshExceededNotifA csnUsageThreshExceededNotif is sent if the Netflow
table usage has exceeded the configured threshold
specified by csnUsageThreshold. NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.737.0.1 |
ciscoSwitchNetflowMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.737.1 |
csnAccounting OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.737.1.1 |
csnAccGlobal OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.737.1.1.1 |
csnNetflowDirectionTypeThis object specifies the direction type of Netflow
enabled on this system.rw CsnNetflowDirectionTypes .1.3.6.1.4.1.9.9.737.1.1.1.1 |
csnAccNotifControl OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.737.1.1.2 |
csnUsageThreshExceedNotifEnableThis object specifies whether the system produces the
csnUsageThreshExceededNotif.
A 'false' value will prevent csnUsageThreshExceededNotif
notifications from being generated by this system.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.737.1.1.2.1 |
cshAccUsageThresh OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.737.1.1.3 |
csnUsageThreshTableA table containing Netflow table usage monitoring
configuration information. SEQUENCE OF CsnUsageThreshEntry .1.3.6.1.4.1.9.9.737.1.1.3.1 |
csnUsageThreshEntryA conceptual row of csnUsageThreshTable, containing
the Netflow table usage monitoring configuration
information. CsnUsageThreshEntry .1.3.6.1.4.1.9.9.737.1.1.3.1.1 |
csnUsageDirectionThis object specifies the direction of Netflow
on the system. CsnNetflowDirectionTypes .1.3.6.1.4.1.9.9.737.1.1.3.1.1.1 |
csnUsageThresholdThis object specifies the Netflow table usage threshold
in percentage value.
When the value of this object is set to zero, Netflow table
usage monitoring is disabled.
When the value of this object is set to greater than zero,
Netflow table usage monitoring is enabled.rw Percent (CISCO-QOS-PIB-MIB) .1.3.6.1.4.1.9.9.737.1.1.3.1.1.2 |
csnUsageIntervalThis object specifies the interval in seconds over
which the Netflow table usage (the value of csnUtilization)
will be compared against the threshold specified by
csnUsageThreshold.rw Unsigned32 .1.3.6.1.4.1.9.9.737.1.1.3.1.1.3 |
csnAccUtilization OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.737.1.1.4 |
csnUtilizationTableA table containing Netflow table utilization information
of each switching engine and a Newflow direction type. SEQUENCE OF CsnUtilizationEntry .1.3.6.1.4.1.9.9.737.1.1.4.1 |
csnUtilizationEntryA conceptual row of csnUtilizationTable, containing
the Netflow table utilization information for a particular
switching engine and a particular Netflow type. CsnUtilizationEntry .1.3.6.1.4.1.9.9.737.1.1.4.1.1 |
csnUtilizationThis object indicates the percentage of Netflow table
utilization.ro Percent (CISCO-QOS-PIB-MIB) .1.3.6.1.4.1.9.9.737.1.1.4.1.1.1 |
csnAccNetflowTableSize OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.737.1.1.5 |
csnNetflowTableSizeTableA table containing Netflow table size information
of each Netflow type supported in the system. SEQUENCE OF CsnNetflowTableSizeEntry .1.3.6.1.4.1.9.9.737.1.1.5.1 |
csnNetflowTableSizeEntryA conceptual row of csnNetflowTableSizeTable, containing
the Netflow table size information for a particular
Netflow type. CsnNetflowTableSizeEntry .1.3.6.1.4.1.9.9.737.1.1.5.1.1 |
csnNetflowTableTotalEntriesThis object indicates the total number of entries
in the Netflow table for a particular Netflow
direction type.ro Unsigned32 .1.3.6.1.4.1.9.9.737.1.1.5.1.1.1 |
csnAccSampler OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.737.1.1.6 |
csnSamplerTotalThis object indicates the total number of Netflow
samplers in the device.ro Unsigned32 .1.3.6.1.4.1.9.9.737.1.1.6.1 |
csnSamplerAvailableThis object indicates the number of Netflow samplers
available in the system.ro Unsigned32 .1.3.6.1.4.1.9.9.737.1.1.6.2 |
ciscoSwitchNetflowMIBConform OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.737.2 |
csnMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.737.2.1 |
csnMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.737.2.2 |