Home/Catalog/CISCO-LRE-CPE-MIB

CISCO-LRE-CPE-MIB

AI MIB Summary

The CISCO-LRE-CPE-MIB enables monitoring and management of Cisco Long Reach Ethernet (LRE) Customer Premise Equipment, specifically tracking DSL/VDSL line parameters, port status, and session statistics for remote access aggregation. This module provides visibility into physical layer connectivity and data rates for LRE-based last-mile deployments where traditional Ethernet or standard DSL is unavailable.

The MIB module for the Cisco Long Reach Ethernet Customer Premise Equipment device information. *** ABBREVIATIONS, ACRONYMS, AND SYMBOLS *** CPE - Customer Premise Equipment DSL - Digital Subscriber Loop VDSL - Very High Speed DSL LRE - Long Reach Ethernet
Main OID:
ciscoLreCpeMIB.1.3.6.1.4.1.9.9.340
19
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

19 total
Object Name
ciscoLreCpeMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.340
clreCpeMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.340.0
clreCpeMIBNotificationsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.340.0.0
ciscoLreCpeMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.340.1
clreCpeDot1dTp
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.340.1.1
clreCpeDot1dTpFdbTable
SEQUENCE OF ClreCpeDot1dTpFdbEntry
.1.3.6.1.4.1.9.9.340.1.1.1
clreCpeDot1dTpFdbEntry
ClreCpeDot1dTpFdbEntry
.1.3.6.1.4.1.9.9.340.1.1.1.1
clreCpeDot1dBasePortIfIndexro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.9.9.340.1.1.1.1.1
clreCpePort
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.340.1.2
clreCpePortTable
SEQUENCE OF ClreCpePortEntry
.1.3.6.1.4.1.9.9.340.1.2.1
clreCpePortEntry
ClreCpePortEntry
.1.3.6.1.4.1.9.9.340.1.2.1.1
clreCpePortAdminStatusrw
Enumeration
.1.3.6.1.4.1.9.9.340.1.2.1.1.1
clreCpePortAdminSpeedrw
Enumeration
.1.3.6.1.4.1.9.9.340.1.2.1.1.2
clreCpePortAdminDuplexrw
Enumeration
.1.3.6.1.4.1.9.9.340.1.2.1.1.3
clreCpePortAdminProtectedrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.340.1.2.1.1.4
clreCpePortOperProtectedro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.340.1.2.1.1.5
clreCpeMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.340.2
clreCpeMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.340.2.1
clreCpeMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.340.2.2

CISCO-LRE-CPE-MIB Technical Reference Overview

The CISCO-LRE-CPE-MIB SNMP MIB module published by Cisco defines 19 managed OID objects, including 6 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.340. Key tabular structures include clreCpeDot1dTpFdbTable, clreCpePortTable.

Key OID Definitions in CISCO-LRE-CPE-MIB

ciscoLreCpeMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.340

The MIB module for the Cisco Long Reach Ethernet Customer Premise Equipment device information. *** ABBREVIATIONS, ACRONYMS, AND SYMBOLS *** CPE - Customer Premise Equipment DSL - Digital Subscriber Loop VDSL - Very High Speed DSL LRE - Long Reach Ethernet

clreCpeDot1dTpFdbTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.340.1.1.1

A table that supplements the information from the BRIDGE-MIB. The BRIDGE-MIB tracks the MAC address to switch interface mapping in the dot1dTpFdbTable. On the long reach ethernet switch, CPE devices connect to the switch interfaces. Each CPE device has one or more ports. This table maps a MAC address on the switch to an interface associated with a CPE port.

clreCpePortTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.340.1.2.1

A list of LRE CPE port entries. The number of entries is determined by the number of Long Reach Ethernet interfaces (to which the CPE attaches) on the switch and the number of Fast Ethernet ports each CPE supports.

clreCpeDot1dTpFdbEntryClreCpeDot1dTpFdbEntrynot-accessible
.1.3.6.1.4.1.9.9.340.1.1.1.1

An entry that supplements the information in the dot1dTpFdbTable table from the BRIDGE-MIB.

clreCpeDot1dBasePortIfIndexInterfaceIndexread-only
.1.3.6.1.4.1.9.9.340.1.1.1.1.1

The value of the instance of the ifIndex object, define in MIB-II, for the interface corresponding to this CPE port. The Forwarding database on the switch tracks a MAC address and its associated switch interface in the dot1dTpFdbTable table. This object adds information about which port on the CPE the MAC address was learnt on.

clreCpePortEntryClreCpePortEntrynot-accessible
.1.3.6.1.4.1.9.9.340.1.2.1.1

Entry containing information for a particular CPE Fast Ethernet port. The entries are created as new CPE devices are discovered. A new CPE device is discovered when the LRE link between that CPE device and the LRE switch becomes operational. These entries are only valid for ifIndexes of ifType ethernetCsmacd(6).

clreCpePortAdminStatusINTEGERread-write
.1.3.6.1.4.1.9.9.340.1.2.1.1.1

The desired state of the CPE port. The testing(3) state indicates that no operational packets can be passed. When a managed system initializes, all CPE ports start with clreCpePortAdminStatus in the down(2) state. As a result of either explicit management action or per configuration information retained by the managed system, clreCpePortAdminStatus is then changed to either the up(1) or testing(3) states (or remains in the down(2) state).

clreCpePortAdminSpeedINTEGERread-write
.1.3.6.1.4.1.9.9.340.1.2.1.1.2

This object controls the speed of this CPE Fast Ethernet port. When set to autoDetect(1), the CPE port negotiates with its peer for the optimum speed, either s10000000(10000000) or s100000000(100000000). If the peer does not support the autoDetect(1) capability, the CPE port speed defaults to s10000000(10000000).

clreCpePortAdminDuplexINTEGERread-write
.1.3.6.1.4.1.9.9.340.1.2.1.1.3

This object controls the duplex of this CPE Fast Ethernet port. When set to autoDetect(1), the CPE port negotiates with its peer for the optimum duplex setting, either fullDuplex(2) or halfDuplex(3). If the peer does not support the autoDetect(1) capability, this CPE port's duplex defaults to halfDuplex(3).

clreCpePortAdminProtectedTruthValueread-write
.1.3.6.1.4.1.9.9.340.1.2.1.1.4

This object configures a CPE Fast Ethernet port as a protected port when its value is set to true. Data traffic is disallowed between two CPE ports configured as protected ports. When the value of this object is set to false, the protected port property of this CPE port is removed. The value of this object can be set to true only on those CPE ports that support the protected port function.Note that the value of this object represents the desired state of the port. The actual state of the port may have a different value.

clreCpePortOperProtectedTruthValueread-only
.1.3.6.1.4.1.9.9.340.1.2.1.1.5

The value represented by this object is the actual protected port state of the CPE port. The object value is true when this CPE port is configured as a protected port. Data packets are not forwarded between two CPE ports configured as protected ports.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→