Home/Catalog/CISCO-IEEE8021-CFM-EXT-MIB

CISCO-IEEE8021-CFM-EXT-MIB

AI MIB Summary

The CISCO-IEEE8021-CFM-EXT-MIB extends Cisco IOS and Catalyst switch monitoring capabilities to track proprietary Connectivity Fault Management (CFM) objects, specifically exposing detailed state data for Maintenance Association End Points (MEPs), Intermediate Points (MIPs), and Linktrace operations that are not defined in the standard IEEE 802.1ag MIB. This module enables granular visibility into Ethernet service instance continuity, fault isolation, and path tracing metrics across Cisco-specific Maintenance Domains and Service Access Points.

A MIB module for extending the IEEE8021-CFM-MIB and IEEE8021-CFM-V2-MIB to add objects which provide additional information about Connectivity Fault management(CFM) not available in IEEE8021-CFM-MIB and IEEE8021-CFM-V2-MIB. Glossary: Connectivity Fault Management (CFM): Connectivity Fault Management comprises capabilities for detecting, verifying, and isolating connectivity failures in Virtual Bridged Local Area Networks. Maintenance Domain (MD): The network or the part of the network for which faults in connectivity can be managed. Service Access Point (SAP): The point at which a service is offered. Domain Service Access Point (DoSAP): A member of a set of SAPs at which a Maintenance Domain is capable of offering connectivity to systems outside the Maintenance Domain. Intermediate Service Access Points (ISAP): A SAP, interior to a Maintenance Domain, through which frames can pass in transit from DoSAP to DoSAP. Maintenance association End Point (MEP): An actively managed CFM entity, associated with a specific domain service access point of a service instance, which can generate and receive CFM PDUs and track any responses. Maintenance Association (MA): A set of MEPs, each configured with the same MAID and MD Level, established to verify the integrity of a single service instance. Maintenance domain Intermediate Point (MIP): A CFM entity consisting of two MHFs. A MHF is a CFM entity, associated with a single Maintenance Domain, and thus with a single MD Level and a set of VIDs, that cannot generate CFM PDUs, but only in response to received CFM PDUs. Continuity Check Message (CCM): A multicast CFM PDU transmitted periodically by a MEP in order to ensure continuity over the MA to which the transmitting MEP belongs. No reply is sent by any MP in response to receiving a CCM. Continuity Check Initiator (CCI): A state machine. Once it starts, CCMs will be generated. Linktrace Message (LTM): A CFM PDU initiated by a MEP to trace a path to a target MAC address, forwarded from MIP to MIP, up to the point at which the LTM reaches its target, a MEP, or can no longer be forwarded. Linktrace Reply (LTR): A unicast CFM PDU sent by an MP to a MEP, in response to receiving an LTM from that MEP. Content Addressable memory (CAM): The CAM table is consulted to make the frame forwarding decision. On Ethernet networks that transmit IP, switches learn MAC addresses from the source address of ethernet frames on the interfaces.
Main OID:
ciscoIeee8021CfmExtMIB.1.3.6.1.4.1.9.9.679
40
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

40 total
Object Name
ciscoIeee8021CfmExtMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.679
cIeeeCfmExtMIBNotifs
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.679.0
cIeeeCfmExtMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.679.1
ciceCfmGlobal
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.679.1.1
ciceCfmEnablerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.679.1.1.1
ciceCfmMaxMdLevelro
Unsigned32
.1.3.6.1.4.1.9.9.679.1.1.2
ciceCfmBrainAddressro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.679.1.1.3
ciceCfmCcMulticastAddressro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.679.1.1.4
ciceCfmLtmMulticastAddressro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.9.9.679.1.1.5
ciceCfmEnableFaultAlarmrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.679.1.1.6
ciceCfmLtr
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.679.1.2
ciceCfmLtrEnablerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.679.1.2.1
ciceCfmLtrHoldTimerw
Unsigned32
.1.3.6.1.4.1.9.9.679.1.2.2
ciceCfmLtrSizerw
Unsigned32
.1.3.6.1.4.1.9.9.679.1.2.3
ciceCfmMa
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.679.1.3
ciceCfmMaNetTable
SEQUENCE OF CiceCfmMaNetEntry
.1.3.6.1.4.1.9.9.679.1.3.1
ciceCfmMaNetEntry
CiceCfmMaNetEntry
.1.3.6.1.4.1.9.9.679.1.3.1.1
ciceCfmMaNetCciEnablerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.679.1.3.1.1.1
ciceCfmMaNetCciDirectionrw
Dot1agCfmMpDirection
.1.3.6.1.4.1.9.9.679.1.3.1.1.2
ciceCfmMaNetLossThresholdrw
Unsigned32
.1.3.6.1.4.1.9.9.679.1.3.1.1.3
ciceCfmIfObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.679.1.4
ciceCfmInterfaceTable
SEQUENCE OF CiceCfmInterfaceEntry
.1.3.6.1.4.1.9.9.679.1.4.1
ciceCfmInterfaceEntry
CiceCfmInterfaceEntry
.1.3.6.1.4.1.9.9.679.1.4.1.1
ciceCfmIfIndex
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.9.9.679.1.4.1.1.1
ciceCfmIfStaterw
Enumeration
.1.3.6.1.4.1.9.9.679.1.4.1.1.2
ciceCfmMipTable
SEQUENCE OF CiceCfmMipEntry
.1.3.6.1.4.1.9.9.679.1.4.2
ciceCfmMipEntry
CiceCfmMipEntry
.1.3.6.1.4.1.9.9.679.1.4.2.1
ciceCfmMipVlanIndex
VlanId (Q-BRIDGE-MIB)
.1.3.6.1.4.1.9.9.679.1.4.2.1.1
ciceCfmMipMdLevelrw
Unsigned32
.1.3.6.1.4.1.9.9.679.1.4.2.1.2
ciceCfmMipStorageTyperw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.679.1.4.2.1.3
ciceCfmMipRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.679.1.4.2.1.4
ciceCfmMacEnableIfTable
SEQUENCE OF CiceCfmMacEnableIfEntry
.1.3.6.1.4.1.9.9.679.1.4.3
ciceCfmMacEnableIfEntry
CiceCfmMacEnableIfEntry
.1.3.6.1.4.1.9.9.679.1.4.3.1
ciceCfmMacEnableVlanIndex
VlanId (Q-BRIDGE-MIB)
.1.3.6.1.4.1.9.9.679.1.4.3.1.1
ciceCfmMacEnableStorageTyperw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.679.1.4.3.1.2
ciceCfmMacEnableRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.679.1.4.3.1.3
ciceCfmMep
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.679.1.5
cIeeeCfmExtMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.679.2
ciceCfmMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.679.2.1
ciceCfmMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.679.2.2

CISCO-IEEE8021-CFM-EXT-MIB Technical Reference Overview

The CISCO-IEEE8021-CFM-EXT-MIB SNMP MIB module published by Cisco defines 40 managed OID objects, including 21 scalar/column metrics, 4 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.679. Key tabular structures include ciceCfmMaNetTable, ciceCfmInterfaceTable, ciceCfmMipTable, ciceCfmMacEnableIfTable.

Key OID Definitions in CISCO-IEEE8021-CFM-EXT-MIB

ciscoIeee8021CfmExtMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.679

A MIB module for extending the IEEE8021-CFM-MIB and IEEE8021-CFM-V2-MIB to add objects which provide additional information about Connectivity Fault management(CFM) not available in IEEE8021-CFM-MIB and IEEE8021-CFM-V2-MIB. Glossary: Connectivity Fault Management (CFM): Connectivity Fault Management comprises capabilities for detecting, verifying, and isolating connectivity failures in Virtual Bridged Local Area Networks. Maintenance Domain (MD): The network or the part of the network for which faults in connectivity can be managed. Service Access Point (SAP): The point at which a service is offered. Domain Service Access Point (DoSAP): A member of a set of SAPs at which a Maintenance Domain is capable of offering connectivity to systems outside the Maintenance Domain. Intermediate Service Access Points (ISAP): A SAP, interior to a Maintenance Domain, through which frames can pass in transit from DoSAP to DoSAP. Maintenance association End Point (MEP): An actively managed CFM entity, associated with a specific domain service access point of a service instance, which can generate and receive CFM PDUs and track any responses. Maintenance Association (MA): A set of MEPs, each configured with the same MAID and MD Level, established to verify the integrity of a single service instance. Maintenance domain Intermediate Point (MIP): A CFM entity consisting of two MHFs. A MHF is a CFM entity, associated with a single Maintenance Domain, and thus with a single MD Level and a set of VIDs, that cannot generate CFM PDUs, but only in response to received CFM PDUs. Continuity Check Message (CCM): A multicast CFM PDU transmitted periodically by a MEP in order to ensure continuity over the MA to which the transmitting MEP belongs. No reply is sent by any MP in response to receiving a CCM. Continuity Check Initiator (CCI): A state machine. Once it starts, CCMs will be generated. Linktrace Message (LTM): A CFM PDU initiated by a MEP to trace a path to a target MAC address, forwarded from MIP to MIP, up to the point at which the LTM reaches its target, a MEP, or can no longer be forwarded. Linktrace Reply (LTR): A unicast CFM PDU sent by an MP to a MEP, in response to receiving an LTM from that MEP. Content Addressable memory (CAM): The CAM table is consulted to make the frame forwarding decision. On Ethernet networks that transmit IP, switches learn MAC addresses from the source address of ethernet frames on the interfaces.

ciceCfmMaNetTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.679.1.3.1

This table contains a list of Maintenance Association.

ciceCfmInterfaceTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.679.1.4.1

This table contains a list of CFM capable ports.

ciceCfmMipTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.679.1.4.2

This table contains a list of Maintenance domain Intermediate Points. This table manages MIPs which are created by rules specified on the Maintenance Association (MA) and Maintenance Domain (MD) on the local device. MIPs can also be created by rules specified on Default MD Level, which is covered by dot1agCfmDefaultMdTable in IEEE8021-CFM-MIB.

ciceCfmMacEnableIfTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.679.1.4.3

This table contains a list of VLANs on CFM interfaces. Each row in the table represents a MAC enable configuration on an interface associated with a VLAN. Creating one row installs a system CAM entry. Linktrace replies and Loopback messages and replies could be seen from the interface for which the Mac address was learnt via the system CAM table for Down MEPs.

ciceCfmEnableTruthValueread-write
.1.3.6.1.4.1.9.9.679.1.1.1

This object enables or disables the CFM feature of the local device. When the object is 'true', CFM feature is enabled. When the object is 'false', CFM feature is disabled.

ciceCfmMaxMdLevelUnsigned32read-only
.1.3.6.1.4.1.9.9.679.1.1.2

This object indicates the maximum MD level that has been configured through dot1agCfmMdMdLevel of IEEE8021-CFM-MIB in the system.

ciceCfmBrainAddressMacAddressread-only
.1.3.6.1.4.1.9.9.679.1.1.3

This object indicates the brain MAC address of the bridge. The brain MAC address is used by unicast CFM messages.

ciceCfmCcMulticastAddressMacAddressread-only
.1.3.6.1.4.1.9.9.679.1.1.4

This object indicates the CFM Continuity Check multicast Mac Address.

ciceCfmLtmMulticastAddressMacAddressread-only
.1.3.6.1.4.1.9.9.679.1.1.5

This object indicates the CFM LTM multicast Mac Address.

ciceCfmEnableFaultAlarmTruthValueread-write
.1.3.6.1.4.1.9.9.679.1.1.6

This variable indicates whether the system produces the dot1agCfmFaultAlarm defined in IEEE8021-CFM-MIB. A value of 'false' prevents dot1agCfmFaultAlarm from being generated.

ciceCfmLtrEnableTruthValueread-write
.1.3.6.1.4.1.9.9.679.1.2.1

This object specifies whether caching CFM LTRs in dot1agCfmLtrTable of IEEE8021-CFM-MIB is enabled. The Linktrace replies will be cached in dot1agCfmLtrTable only if this object has the value of 'true'.

ciceCfmLtrHoldTimeUnsigned32read-write
.1.3.6.1.4.1.9.9.679.1.2.2

This object is the cache time for retaining an entry in dot1agCfmLtrTable of IEEE8021-CFM-MIB.

ciceCfmLtrSizeUnsigned32read-write
.1.3.6.1.4.1.9.9.679.1.2.3

This object is the cache size of LTRs in dot1agCfmLtrTable of IEEE8021-CFM-MIB. A value of zero for this object indicates that there is no limitation on the cache size.

ciceCfmMaNetEntryCiceCfmMaNetEntrynot-accessible
.1.3.6.1.4.1.9.9.679.1.3.1.1

An entry containing Continuity Check configuration for a particular MA.

ciceCfmMaNetCciEnableTruthValueread-write
.1.3.6.1.4.1.9.9.679.1.3.1.1.1

This object specifies whether Continuity Check Initiator is enabled. A value of 'true' indicates that the Continuity Check Initiator state machine will start and all MEPs in this MA will generate Continuity Check Messages (CCMs).

ciceCfmMaNetCciDirectionDot1agCfmMpDirectionread-write
.1.3.6.1.4.1.9.9.679.1.3.1.1.2

This object specifies the direction in which the Maintenance association faces on the bridge port.

ciceCfmMaNetLossThresholdUnsigned32read-write
.1.3.6.1.4.1.9.9.679.1.3.1.1.3

This object specifies the number of CCMs that is allowed to be lost before cleaning up the corresponding entry in CC database.

ciceCfmInterfaceEntryCiceCfmInterfaceEntrynot-accessible
.1.3.6.1.4.1.9.9.679.1.4.1.1

An entry containing information about the CFM state on a particular CFM capable port.

ciceCfmIfIndexInterfaceIndexnot-accessible
.1.3.6.1.4.1.9.9.679.1.4.1.1.1

The port number associated with this CFM port. This is a unique index for an entry in the ciceCfmInterfaceTable. A non-zero index for an entry indicates the ifIndex for the corresponding CFM capable interface entry in the ifTable. Note that this table does not necessarily correspond one-to-one with all entries in the Interface MIB; rather, only those which are enabled for CFM functionality.

ciceCfmIfStateINTEGERread-write
.1.3.6.1.4.1.9.9.679.1.4.1.1.2

The administrative CFM state of the port. enable - enables CFM on the port. disable - disables CFM on the port. transparent - forward CFM frames like regular data traffic.

ciceCfmMipEntryCiceCfmMipEntrynot-accessible
.1.3.6.1.4.1.9.9.679.1.4.2.1

An entry containing configuration of a particular MIP. Each row in the table represents a different MIP. In order to facilitate the diagnosis of connectivity failures, an administrator can make a DoSAP visible as an ISAP to the immediately enclosing Maintenance Domain by configuring it as a MIP. In the lowest Maintenance Domains, the MIPs can be configured on individual Bridge Ports.

ciceCfmMipVlanIndexVlanIdnot-accessible
.1.3.6.1.4.1.9.9.679.1.4.2.1.1

The VLAN-ID with which the MIP is associated on the interface.

ciceCfmMipMdLevelUnsigned32read-create
.1.3.6.1.4.1.9.9.679.1.4.2.1.2

The MD level of the MIP.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→