CISCO-GSLB-SYSTEM-MIB
The CISCO-GSLB-SYSTEM-MIB provides SNMP management objects for Cisco Global Server Load Balancers (GSLB) to monitor device status, peer relationships, and proximity probing metrics such as Round-Trip Time (RTT) and Director Response Protocol (DRP) statistics. It enables the tracking of network topology-based load distribution decisions, including zone and location assignments, to facilitate optimal client request routing based on topological proximity and server availability.
Imported Objects
Objects
85 total| Object Name |
|---|
ciscoGslbSystemMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.589 |
ciscoGslbSystemMIBNotifs OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.589.0 |
ciscoGslbSystemPeerEventStatus NOTIFICATION-TYPE .1.3.6.1.4.1.9.9.589.0.1 |
ciscoGslbSystemMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.589.1 |
cgsNotifControl OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.589.1.1 |
cgsPeerEventNotifEnablerw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.589.1.1.1 |
cgsNotifObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.589.1.2 |
cgsPeerPrevStatusro CiscoGslbPeerStatus (CISCO-GSLB-TC-MIB) .1.3.6.1.4.1.9.9.589.1.2.1 |
cgsGeneral OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.589.1.3 |
cgsNodeServicerw CiscoGslbNodeServices (CISCO-GSLB-TC-MIB) .1.3.6.1.4.1.9.9.589.1.3.1 |
cgsNodeCommIfNamerw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.589.1.3.2 |
cgsNodeCommIfIndexro InterfaceIndexOrZero (IF-MIB) .1.3.6.1.4.1.9.9.589.1.3.3 |
cgsNodeStatusro CiscoGslbPeerStatus (CISCO-GSLB-TC-MIB) .1.3.6.1.4.1.9.9.589.1.3.4 |
cgsNodeLocationrw SnmpAdminString .1.3.6.1.4.1.9.9.589.1.3.5 |
cgsNodeRegionro SnmpAdminString .1.3.6.1.4.1.9.9.589.1.3.6 |
cgsPeer OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.589.1.4 |
cgsPeerTable SEQUENCE OF CgsPeerEntry .1.3.6.1.4.1.9.9.589.1.4.1 |
cgsPeerEntry CgsPeerEntry .1.3.6.1.4.1.9.9.589.1.4.1.1 |
cgsPeerAddressType InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.589.1.4.1.1.1 |
cgsPeerAddress InetAddress .1.3.6.1.4.1.9.9.589.1.4.1.1.2 |
cgsPeerLocationrw SnmpAdminString .1.3.6.1.4.1.9.9.589.1.4.1.1.3 |
cgsPeerDnsNamero InetAddressDNS (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.589.1.4.1.1.4 |
cgsPeerServicero CiscoGslbNodeServices (CISCO-GSLB-TC-MIB) .1.3.6.1.4.1.9.9.589.1.4.1.1.5 |
cgsPeerStatusro CiscoGslbPeerStatus (CISCO-GSLB-TC-MIB) .1.3.6.1.4.1.9.9.589.1.4.1.1.6 |
cgsPeerVersionro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.589.1.4.1.1.7 |
cgsProxZoneStats OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.589.1.5 |
cgsProxZoneTable SEQUENCE OF CgsProxZoneEntry .1.3.6.1.4.1.9.9.589.1.5.1 |
cgsProxZoneEntry CgsProxZoneEntry .1.3.6.1.4.1.9.9.589.1.5.1.1 |
cgsProxZoneName SnmpAdminString .1.3.6.1.4.1.9.9.589.1.5.1.1.1 |
cgsProxPrimaryAddressTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.589.1.5.1.1.2 |
cgsProxPrimaryAddressrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.589.1.5.1.1.3 |
cgsProxSecondaryAddressTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.589.1.5.1.1.4 |
cgsProxSecondaryAddressrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.9.9.589.1.5.1.1.5 |
cgsProxEchoSentReqsro Counter32 UNITS "requests" .1.3.6.1.4.1.9.9.589.1.5.1.1.6 |
cgsProxEchoRcvdRespsro Counter32 UNITS "responses" .1.3.6.1.4.1.9.9.589.1.5.1.1.7 |
cgsProxSentMeasureReqsro Counter32 UNITS "requests" .1.3.6.1.4.1.9.9.589.1.5.1.1.8 |
cgsProxRcvdMeasureRespsro Counter32 UNITS "responses" .1.3.6.1.4.1.9.9.589.1.5.1.1.9 |
cgsProxTotalSentReqsro Counter32 UNITS "requests" .1.3.6.1.4.1.9.9.589.1.5.1.1.10 |
cgsProxTotalRcvdRespsro Counter32 UNITS "responses" .1.3.6.1.4.1.9.9.589.1.5.1.1.11 |
cgsProxSendRatero Unsigned32 UNITS "rate per second" .1.3.6.1.4.1.9.9.589.1.5.1.1.12 |
cgsProxRcvdRatero Unsigned32 UNITS "rate per second" .1.3.6.1.4.1.9.9.589.1.5.1.1.13 |
cgsProxPeakSendRatero Unsigned32 UNITS "rate per second" .1.3.6.1.4.1.9.9.589.1.5.1.1.14 |
cgsProxPeakRcvdRatero Unsigned32 UNITS "rate per second" .1.3.6.1.4.1.9.9.589.1.5.1.1.15 |
cgsProxStorageTyperw StorageType (SNMPv2-TC) .1.3.6.1.4.1.9.9.589.1.5.1.1.16 |
cgsProxRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.589.1.5.1.1.17 |
cgsResources OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.589.1.6 |
cgsRegionTabledeprecated SEQUENCE OF CgsRegionEntry .1.3.6.1.4.1.9.9.589.1.6.1 |
cgsRegionEntrydeprecated CgsRegionEntry .1.3.6.1.4.1.9.9.589.1.6.1.1 |
cgsRegionNamedeprecated SnmpAdminString .1.3.6.1.4.1.9.9.589.1.6.1.1.1 |
cgsRegionCommentsrwdeprecated SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.589.1.6.1.1.2 |
cgsRegionStorageTyperwdeprecated StorageType (SNMPv2-TC) .1.3.6.1.4.1.9.9.589.1.6.1.1.3 |
cgsRegionRowStatusrwdeprecated RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.589.1.6.1.1.4 |
cgsLocationTable SEQUENCE OF CgsLocationEntry .1.3.6.1.4.1.9.9.589.1.6.2 |
cgsLocationEntry CgsLocationEntry .1.3.6.1.4.1.9.9.589.1.6.2.1 |
cgsLocationName SnmpAdminString .1.3.6.1.4.1.9.9.589.1.6.2.1.1 |
cgsLocationRegionrw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.589.1.6.2.1.2 |
cgsLocationZonerw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.589.1.6.2.1.3 |
cgsLocationCommentsrw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.589.1.6.2.1.4 |
cgsLocationStorageTyperw StorageType (SNMPv2-TC) .1.3.6.1.4.1.9.9.589.1.6.2.1.5 |
cgsLocationRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.589.1.6.2.1.6 |
cgsRegionIdTable SEQUENCE OF CgsRegionIdEntry .1.3.6.1.4.1.9.9.589.1.6.3 |
cgsRegionIdEntry CgsRegionIdEntry .1.3.6.1.4.1.9.9.589.1.6.3.1 |
cgsRegionId Unsigned32 .1.3.6.1.4.1.9.9.589.1.6.3.1.1 |
cgsRegionIdNamerw SnmpAdminString .1.3.6.1.4.1.9.9.589.1.6.3.1.2 |
cgsRegionIdCommentsrw SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.9.9.589.1.6.3.1.3 |
cgsReqCountPerRegionIdro Counter32 UNITS "number of hits" .1.3.6.1.4.1.9.9.589.1.6.3.1.4 |
cgsReqCountRatePerRegionId1Minro Gauge32 UNITS "hits per second" .1.3.6.1.4.1.9.9.589.1.6.3.1.5 |
cgsReqCountRatePerRegionId5Minro Gauge32 UNITS "hits per second" .1.3.6.1.4.1.9.9.589.1.6.3.1.6 |
cgsReqCountRatePerRegionId30Minro Gauge32 UNITS "hits per second" .1.3.6.1.4.1.9.9.589.1.6.3.1.7 |
cgsReqCountRatePerRegionId4Hrro Gauge32 UNITS "hits per second" .1.3.6.1.4.1.9.9.589.1.6.3.1.8 |
cgsAnswerCountPerRegionIdro Counter32 UNITS "number of hits" .1.3.6.1.4.1.9.9.589.1.6.3.1.9 |
cgsAnswerCountRatePerRegionId1Minro Gauge32 UNITS "hits per second" .1.3.6.1.4.1.9.9.589.1.6.3.1.10 |
cgsAnswerCountRatePerRegionId5Minro Gauge32 UNITS "hits per second" .1.3.6.1.4.1.9.9.589.1.6.3.1.11 |
cgsAnswerCountRatePerRegionId30Minro Gauge32 UNITS "hits per second" .1.3.6.1.4.1.9.9.589.1.6.3.1.12 |
cgsAnswerCountRatePerRegionId4Hrro Gauge32 UNITS "hits per second" .1.3.6.1.4.1.9.9.589.1.6.3.1.13 |
cgsUnAnswerCountPerRegionIdro Counter32 UNITS "number of hits" .1.3.6.1.4.1.9.9.589.1.6.3.1.14 |
cgsUnAnswerCountRatePerRegionId1Minro Gauge32 UNITS "hits per second" .1.3.6.1.4.1.9.9.589.1.6.3.1.15 |
cgsUnAnswerCountRatePerRegionId5Minro Gauge32 UNITS "hits per second" .1.3.6.1.4.1.9.9.589.1.6.3.1.16 |
cgsUnAnswerCountRatePerRegionId30Minro Gauge32 UNITS "hits per second" .1.3.6.1.4.1.9.9.589.1.6.3.1.17 |
cgsUnAnswerCountRatePerRegionId4Hrro Gauge32 UNITS "hits per second" .1.3.6.1.4.1.9.9.589.1.6.3.1.18 |
cgsRegionIdStorageTyperw StorageType (SNMPv2-TC) .1.3.6.1.4.1.9.9.589.1.6.3.1.19 |
cgsRegionIdRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.9.9.589.1.6.3.1.20 |
ciscoGslbSystemMIBConform OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.589.2 |
ciscoGslbSystemMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.589.2.1 |
ciscoGslbSystemMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.589.2.2 |
CISCO-GSLB-SYSTEM-MIB Technical Reference Overview
The CISCO-GSLB-SYSTEM-MIB SNMP MIB module published by Cisco defines 85 managed OID objects, including 62 scalar/column metrics, 5 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.589. Key tabular structures include cgsPeerTable, cgsProxZoneTable, cgsRegionTable, cgsLocationTable, cgsRegionIdTable. Monitored SNMP traps/notifications include ciscoGslbSystemPeerEventStatus.
Key OID Definitions in CISCO-GSLB-SYSTEM-MIB
.1.3.6.1.4.1.9.9.589This MIB module defines objects for network and system information of Global Server Load Balancer(GSLB) as a network device. A GSLB device is used to allocate the least-loaded and proximate resource to the requester. The MIB objects define information about GLSB status, GSLB's peers (other GSLB devices available on its network with which it interacts) information & status, GSLB's proximity information related statistics, etc. Further it defines related notifications. Acronyms and their description: DNS : Domain Name Service (RFC1035). D-proxy : Local DNS name server of the client. Proximity : Refers to the distance or delay, in terms of network topology and not geographic distance, between the requesting client's D-proxy and the resources corresponding to that request. Proximity : To respond to DNS requests with the most probing proximate answers, the GSLB device communicates with a probing device located in each proximity zone to gather round-trip time (RTT) metric information measured between the requesting client's D-proxy and the zone. The GSLB device then directs client requests to an available resource with the lowest RTT value. Probed : This is the device to which the GSLB device device sends a proximity probe. This is done to learn the proximity of the device. DRP : Director Response Protocol (DRP) is a simple User Datagram Protocol (UDP) based application developed by Cisco Systems, Inc. DRP enables Cisco Distributed-Director product to perform global load distribution and content routing in a sophisticated manner that accounts for server availability, relative client-to-server topological proximities, and client-to-server link latency to determine the best server. Using routing table intelligence in the network infrastructure, Distributed-Director transparently redirects end-user service requests to the closest server, as determined by client-to-server topological proximity or client-to-server link latency, resulting in increased access performance seen by the end user. Region : Higher-level geographical groupings that may contain one or more locations. Each location should be assigned to a region. Location : Grouping for devices with common geographical attributes. A location is assigned to a region. A location is also assigned to a zone, which is used for proximity probing. Zone : A network can be logically partioned into zones based on the arrangement of devices and network partion characteristics. A zone can be geographically related to data centers in a continent, a country, or a major city. All devices, such as web servers in a data center, that are located in the same zone have the same proximity value when communicating with other areas of the Internet. Within each zone, there is an active probing device that is configured to accept probing instructions from any GSLB device. Probing here refers to the process of measuring RTT from one probing device to a requesting D-proxy.
.1.3.6.1.4.1.9.9.589.1.4.1This table lists the information on peers in the GSLB network of devices.
.1.3.6.1.4.1.9.9.589.1.5.1This table is used for configuring proximity zones. It consists a list of proximity probing statistics for each configured proximity zone.
.1.3.6.1.4.1.9.9.589.1.6.1This table is used to configure regions on the device. It consists a list of regions configured on the GSLB device.
.1.3.6.1.4.1.9.9.589.1.6.2This table is used to configure locations on the device. It consists a list of locations configured on the GSLB device.
.1.3.6.1.4.1.9.9.589.1.6.3This table is used to configure regions on the device. It consists a list of regions configured on the GSLB device.
.1.3.6.1.4.1.9.9.589.0.1This notification is sent when the value of cgsPeerStatus changes from one state to another. This notification is reported only by a GSLB device with cgsNodeService value of 'primary'.
.1.3.6.1.4.1.9.9.589.1.3.1This object specifies the type of role of the GSLB device amongst its peers.
.1.3.6.1.4.1.9.9.589.1.3.2This object specifies the textual name of the interface used by the GSLB device to communicate with peer GSLB devices. The value of this object must be same as the ifName reported by IF-MIB for the interface instance.
.1.3.6.1.4.1.9.9.589.1.3.3This object is used as an identifier for the interface used by the GSLB device to communicate with peer GSLB devices. The value of this object must be same as the ifIndex reported by IF-MIB for the interface identified by cgsNodeCommIfName.
.1.3.6.1.4.1.9.9.589.1.3.4This object specifies the status of the GSLB device as known on the GSLB network of peers.
.1.3.6.1.4.1.9.9.589.1.3.5This object specifies the administratively assigned location for the GSLB device.
.1.3.6.1.4.1.9.9.589.1.3.6This object specifies the administratively assigned region for the GSLB device. This value corresponds to an instance of cgsLocationRegion from cgsLocationTable.
.1.3.6.1.4.1.9.9.589.1.1.1This object defines the administrative state of sending notifications to signal a GSLB peer status change.
.1.3.6.1.4.1.9.9.589.1.2.1This object is used for sending the value of cgsPeerStatus before transitioning to new state.
.1.3.6.1.4.1.9.9.589.1.4.1.1An entry in cgsPeerEntryTable. Each entry contains information on the GSLB peers. Entries are added/deleted when a GSLB peer device is added/deleted in GSLB network of peers.
.1.3.6.1.4.1.9.9.589.1.4.1.1.1This object specifies the IP address type of the GSLB peer.
.1.3.6.1.4.1.9.9.589.1.4.1.1.2This object specifies the GSLB peer IP address. The type of IP address is identified by cgsPeerAddressType.
.1.3.6.1.4.1.9.9.589.1.4.1.1.3This object specifies the administratively assigned location of the GSLB peer. Its value must be same as the value configured in cgsLocationTable.
.1.3.6.1.4.1.9.9.589.1.4.1.1.4This object specifies the host name assigned uniquely to a GSLB peer. Its value is same as the value of sysName of the GSLB peer.
.1.3.6.1.4.1.9.9.589.1.4.1.1.5This object specifies the type of role the GSLB peer has in a GSLB network of peers. Its value is same as value of cgsNodeService of the GSLB peer.
.1.3.6.1.4.1.9.9.589.1.4.1.1.6This object specifies the status of GSLB peer as known to the reporting GSLB device.
.1.3.6.1.4.1.9.9.589.1.4.1.1.7This object specifies the software version installed on the GSLB peer.
.1.3.6.1.4.1.9.9.589.1.5.1.1An entry in cgsProxZoneTable. Each entry contains information on proximity zones and probing statistics. Entries can be added/deleted/modified by administrator action.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.