CISCO-EVC-MIB

AI MIB Summary

The CISCO-EVC-MIB enables monitoring and provisioning of Metro Ethernet Forum (MEF) defined Ethernet Virtual Connections (EVCs) on Cisco IOS/IOS-XE platforms, specifically managing service instances, User Network Interface (UNI) attributes, and CE-VLAN mapping. It tracks operational states for EVC creation and deletion, monitors flow points for ingress/egress demarcation, and provides notifications for service instance status changes and associated Layer 2 control protocol processing.

Metro Ethernet services can support a wide range of applications and subscriber needs easily, efficiently and cost-effectively. Using standard Ethernet interfaces, subscribers can set up secure, private Ethernet Virtual Connections, to connect their sites together and connect to business partners, suppliers and the Internet. This MIB module defines the managed objects and notifications describing Ethernet Virtual Connections. Ethernet Virtual Connections (EVC), are defined by the Metro Ethernet Forum (MEF), as an association between two or more UNIs. Frames within an EVC can only be exchanged among the associated UNIs. Frames sent into the MEN via a particular UNI must not be delivered back to the UNI from which it originated. Along an EVC path, there are demarcation flow points on associated ingress and egress interface, of every device, through which the EVC passes. A service instance represents these flow points where a service passes through an interface. From an operational perspective, a service instance serves three purposes: 1. Defines the instance of a particular EVC service on a specific interface and identifies all frames that belongs to that particular service/flow. 2. To provide the capability of applying the configured features to those frames belonging to the service. 3. To optionally define how to forward those frames in the data-path. The association of a service instance to an EVC depicts an instance of an Ethernet flow on a particular interface for an end-to-end (UNI-to-UNI) Ethernet service for a subscriber. The following diagram illustrates the association of EVC, UNIs and service instances. UNI physical ports are depicted as 'U', and service instances as 'x'. CE MEN MEN CE - - | | | | () | | | | | |Ux x||x xU| | | | | | () | | | | - - ^ ^ | | EVC - This MIB module addresses the functional areas of network management for EVC, including: The operational mode for interfaces that are providing Ethernet service(s). The service attributes regarding an interface behaving as UNI, such as CE-VLAN mapping and layer 2 control protocol (eg. stp, vtp, cdp) processing. The provisioning of service instances to define flow points for an Ethernet service. The operational status of EVCs for notifications of status changes, and EVC creation and deletion. Definition of terms and acronyms: B-Tag: Backbone Tag field in Ethernet 802.1ah frame CE: Customer Edge CE-VLAN: Customer Edge VLAN CoS: Class Of Service EVC: Ethernet Virtual Connection I-SID: Service Instance Identifier field in Ethernet 802.1ah frame MAC: Media Access Control MEN: Metro Ethernet Network NNI: Network to Network Interface OAM: Operations Administration and Management PPPoE: Point-to-Point Protocol over Ethernet Service frame: An Ethernet frame transmitted across the UNI toward the service provider or an Ethernet frame transmitted across the UNI toward the Subscriber. Service Instance: A flow point of an Ethernet service Service provider: The organization providing Ethernet service(s). Subscriber: The organization purchasing and/or using Ethernet service(s). UNI: User Network Interface The physical demarcation point between the responsibility of the service provider and the responsibility of the Subscriber. UNI-C: User Network Interface, subscriber side UNI-N: User Network Interface, service provider side VLAN: Virtual Local Area Network
Main OID:
ciscoEvcMIB.1.3.6.1.4.1.9.9.613
136
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

136 total
Object Name
ciscoEvcMIB
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.613
ciscoEvcMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.613.0
ciscoEvcNotificationPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.613.0.0
cevcEvcStatusChangedNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.613.0.0.1
cevcEvcCreationNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.613.0.0.2
cevcEvcDeletionNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.613.0.0.3
cevcMacSecurityViolationNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.613.0.0.4
ciscoEvcMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.613.1
cevcSystem
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.613.1.1
cevcMaxNumEvcsro
Gauge32
.1.3.6.1.4.1.9.9.613.1.1.1
cevcNumCfgEvcsro
Gauge32
.1.3.6.1.4.1.9.9.613.1.1.2
cevcPort
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.613.1.2
cevcPortTable
SEQUENCE OF CevcPortEntry
.1.3.6.1.4.1.9.9.613.1.2.1
cevcPortEntry
CevcPortEntry
.1.3.6.1.4.1.9.9.613.1.2.1.1
cevcPortModerw
Enumeration
.1.3.6.1.4.1.9.9.613.1.2.1.1.1
cevcPortMaxNumEVCsro
Gauge32
.1.3.6.1.4.1.9.9.613.1.2.1.1.2
cevcPortMaxNumServiceInstancesro
Gauge32
.1.3.6.1.4.1.9.9.613.1.2.1.1.3
cevcUniTable
SEQUENCE OF CevcUniEntry
.1.3.6.1.4.1.9.9.613.1.2.2
cevcUniEntry
CevcUniEntry
.1.3.6.1.4.1.9.9.613.1.2.2.1
cevcUniIdentifierrw
SnmpAdminString
.1.3.6.1.4.1.9.9.613.1.2.2.1.1
cevcUniPortTyperw
Enumeration
.1.3.6.1.4.1.9.9.613.1.2.2.1.2
cevcUniServiceAttributesrw
Bits
.1.3.6.1.4.1.9.9.613.1.2.2.1.3
cevcPortL2ControlProtocolTable
SEQUENCE OF CevcPortL2ControlProtocolEntry
.1.3.6.1.4.1.9.9.613.1.2.3
cevcPortL2ControlProtocolEntry
CevcPortL2ControlProtocolEntry
.1.3.6.1.4.1.9.9.613.1.2.3.1
cevcPortL2ControlProtocolType
CevcL2ControlProtocolType
.1.3.6.1.4.1.9.9.613.1.2.3.1.1
cevcPortL2ControlProtocolActionrw
Enumeration
.1.3.6.1.4.1.9.9.613.1.2.3.1.2
cevcUniCEVlanEvcTable
SEQUENCE OF CevcUniCEVlanEvcEntry
.1.3.6.1.4.1.9.9.613.1.2.4
cevcUniCEVlanEvcEntry
CevcUniCEVlanEvcEntry
.1.3.6.1.4.1.9.9.613.1.2.4.1
cevcUniEvcIndex
CiscoEvcIndex
.1.3.6.1.4.1.9.9.613.1.2.4.1.1
cevcUniCEVlanEvcBeginningVlan
VlanId (Q-BRIDGE-MIB)
.1.3.6.1.4.1.9.9.613.1.2.4.1.2
cevcUniCEVlanEvcEndingVlanro
VlanIdOrNone (Q-BRIDGE-MIB)
.1.3.6.1.4.1.9.9.613.1.2.4.1.3
cevcEvc
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.613.1.3
cevcEvcTable
SEQUENCE OF CevcEvcEntry
.1.3.6.1.4.1.9.9.613.1.3.1
cevcEvcEntry
CevcEvcEntry
.1.3.6.1.4.1.9.9.613.1.3.1.1
cevcEvcIndex
CiscoEvcIndex
.1.3.6.1.4.1.9.9.613.1.3.1.1.1
cevcEvcRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.3.1.1.2
cevcEvcStorageTyperw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.3.1.1.3
cevcEvcIdentifierrw
SnmpAdminString
.1.3.6.1.4.1.9.9.613.1.3.1.1.4
cevcEvcTyperw
Enumeration
.1.3.6.1.4.1.9.9.613.1.3.1.1.5
cevcEvcCfgUnisrw
Unsigned32
.1.3.6.1.4.1.9.9.613.1.3.1.1.6
cevcEvcStateTable
SEQUENCE OF CevcEvcStateEntry
.1.3.6.1.4.1.9.9.613.1.3.2
cevcEvcStateEntry
CevcEvcStateEntry
.1.3.6.1.4.1.9.9.613.1.3.2.1
cevcEvcOperStatusro
Enumeration
.1.3.6.1.4.1.9.9.613.1.3.2.1.1
cevcEvcActiveUnisro
Gauge32
.1.3.6.1.4.1.9.9.613.1.3.2.1.2
cevcEvcUniTable
SEQUENCE OF CevcEvcUniEntry
.1.3.6.1.4.1.9.9.613.1.3.3
cevcEvcUniEntry
CevcEvcUniEntry
.1.3.6.1.4.1.9.9.613.1.3.3.1
cevcEvcUniIndex
Unsigned32
.1.3.6.1.4.1.9.9.613.1.3.3.1.1
cevcEvcUniIdro
SnmpAdminString
.1.3.6.1.4.1.9.9.613.1.3.3.1.2
cevcEvcUniOperStatusro
Enumeration
.1.3.6.1.4.1.9.9.613.1.3.3.1.3
cevcEvcLocalUniIfIndexro
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.9.9.613.1.3.3.1.4
cevcServiceInstance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.613.1.4
cevcSITable
SEQUENCE OF CevcSIEntry
.1.3.6.1.4.1.9.9.613.1.4.1
cevcSIEntry
CevcSIEntry
.1.3.6.1.4.1.9.9.613.1.4.1.1
cevcSIIndex
Unsigned32
.1.3.6.1.4.1.9.9.613.1.4.1.1.1
cevcSIRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.4.1.1.2
cevcSIStorageTyperw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.4.1.1.3
cevcSITargetTyperw
ServiceInstanceTargetType
.1.3.6.1.4.1.9.9.613.1.4.1.1.4
cevcSITargetrw
ServiceInstanceTarget
.1.3.6.1.4.1.9.9.613.1.4.1.1.5
cevcSINamerw
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.9.9.613.1.4.1.1.6
cevcSIEvcIndexrw
CiscoEvcIndexOrZero
.1.3.6.1.4.1.9.9.613.1.4.1.1.7
cevcSIAdminStatusrw
Enumeration
.1.3.6.1.4.1.9.9.613.1.4.1.1.8
cevcSIForwardingTyperw
Enumeration
.1.3.6.1.4.1.9.9.613.1.4.1.1.9
cevcSICreationTypero
Enumeration
.1.3.6.1.4.1.9.9.613.1.4.1.1.10
cevcSITyperw
Enumeration
.1.3.6.1.4.1.9.9.613.1.4.1.1.11
cevcSIStateTable
SEQUENCE OF CevcSIStateEntry
.1.3.6.1.4.1.9.9.613.1.4.2
cevcSIStateEntry
CevcSIStateEntry
.1.3.6.1.4.1.9.9.613.1.4.2.1
cevcSIOperStatusro
Enumeration
.1.3.6.1.4.1.9.9.613.1.4.2.1.1
cevcSIVlanRewriteTable
SEQUENCE OF CevcSIVlanRewriteEntry
.1.3.6.1.4.1.9.9.613.1.4.3
cevcSIVlanRewriteEntry
CevcSIVlanRewriteEntry
.1.3.6.1.4.1.9.9.613.1.4.3.1
cevcSIVlanRewriteDirection
Enumeration
.1.3.6.1.4.1.9.9.613.1.4.3.1.1
cevcSIVlanRewriteRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.4.3.1.2
cevcSIVlanRewriteStorageTyperw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.4.3.1.3
cevcSIVlanRewriteActionrw
Enumeration
.1.3.6.1.4.1.9.9.613.1.4.3.1.4
cevcSIVlanRewriteEncapsulationrw
Enumeration
.1.3.6.1.4.1.9.9.613.1.4.3.1.5
cevcSIVlanRewriteVlan1rw
VlanId (Q-BRIDGE-MIB)
.1.3.6.1.4.1.9.9.613.1.4.3.1.6
cevcSIVlanRewriteVlan2rw
VlanId (Q-BRIDGE-MIB)
.1.3.6.1.4.1.9.9.613.1.4.3.1.7
cevcSIVlanRewriteSymmetricrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.4.3.1.8
cevcSIL2ControlProtocolTable
SEQUENCE OF CevcSIL2ControlProtocolEntry
.1.3.6.1.4.1.9.9.613.1.4.4
cevcSIL2ControlProtocolEntry
CevcSIL2ControlProtocolEntry
.1.3.6.1.4.1.9.9.613.1.4.4.1
cevcSIL2ControlProtocolType
CevcL2ControlProtocolType
.1.3.6.1.4.1.9.9.613.1.4.4.1.1
cevcSIL2ControlProtocolActionrw
Enumeration
.1.3.6.1.4.1.9.9.613.1.4.4.1.2
cevcSICEVlanTable
SEQUENCE OF CevcSICEVlanEntry
.1.3.6.1.4.1.9.9.613.1.4.5
cevcSICEVlanEntry
CevcSICEVlanEntry
.1.3.6.1.4.1.9.9.613.1.4.5.1
cevcSICEVlanBeginningVlan
VlanId (Q-BRIDGE-MIB)
.1.3.6.1.4.1.9.9.613.1.4.5.1.1
cevcSICEVlanRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.4.5.1.2
cevcSICEVlanStorageTyperw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.4.5.1.3
cevcSICEVlanEndingVlanrw
VlanIdOrNone (Q-BRIDGE-MIB)
.1.3.6.1.4.1.9.9.613.1.4.5.1.4
cevcSIMatchCriteriaTable
SEQUENCE OF CevcSIMatchCriteriaEntry
.1.3.6.1.4.1.9.9.613.1.4.6
cevcSIMatchCriteriaEntry
CevcSIMatchCriteriaEntry
.1.3.6.1.4.1.9.9.613.1.4.6.1
cevcSIMatchCriteriaIndex
Unsigned32
.1.3.6.1.4.1.9.9.613.1.4.6.1.1
cevcSIMatchRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.4.6.1.2
cevcSIMatchStorageTyperw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.4.6.1.3
cevcSIMatchCriteriaTyperw
Enumeration
.1.3.6.1.4.1.9.9.613.1.4.6.1.4
cevcSIMatchEncapTable
SEQUENCE OF CevcSIMatchEncapEntry
.1.3.6.1.4.1.9.9.613.1.4.7
cevcSIMatchEncapEntry
CevcSIMatchEncapEntry
.1.3.6.1.4.1.9.9.613.1.4.7.1
cevcSIMatchEncapRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.4.7.1.1
cevcSIMatchEncapStorageTyperw
StorageType (SNMPv2-TC)
.1.3.6.1.4.1.9.9.613.1.4.7.1.2
cevcSIMatchEncapValidrw
Bits
.1.3.6.1.4.1.9.9.613.1.4.7.1.3
cevcSIMatchEncapEncapsulationrw
Enumeration
.1.3.6.1.4.1.9.9.613.1.4.7.1.4
cevcSIMatchEncapPrimaryCosrw
CiscoCosList (CISCO-TC)
.1.3.6.1.4.1.9.9.613.1.4.7.1.5
Showing 100 of 136 OID objects

CISCO-EVC-MIB Technical Reference Overview

The CISCO-EVC-MIB SNMP MIB module published by Cisco defines 136 managed OID objects, including 85 scalar/column metrics, 17 SNMP tables, and 4 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.613. Key tabular structures include cevcPortTable, cevcUniTable, cevcPortL2ControlProtocolTable, cevcUniCEVlanEvcTable, cevcEvcTable, cevcEvcStateTable. Monitored SNMP traps/notifications include cevcEvcStatusChangedNotification, cevcEvcCreationNotification, cevcEvcDeletionNotification, cevcMacSecurityViolationNotification.

Key OID Definitions in CISCO-EVC-MIB

ciscoEvcMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.9.9.613

Metro Ethernet services can support a wide range of applications and subscriber needs easily, efficiently and cost-effectively. Using standard Ethernet interfaces, subscribers can set up secure, private Ethernet Virtual Connections, to connect their sites together and connect to business partners, suppliers and the Internet. This MIB module defines the managed objects and notifications describing Ethernet Virtual Connections. Ethernet Virtual Connections (EVC), are defined by the Metro Ethernet Forum (MEF), as an association between two or more UNIs. Frames within an EVC can only be exchanged among the associated UNIs. Frames sent into the MEN via a particular UNI must not be delivered back to the UNI from which it originated. Along an EVC path, there are demarcation flow points on associated ingress and egress interface, of every device, through which the EVC passes. A service instance represents these flow points where a service passes through an interface. From an operational perspective, a service instance serves three purposes: 1. Defines the instance of a particular EVC service on a specific interface and identifies all frames that belongs to that particular service/flow. 2. To provide the capability of applying the configured features to those frames belonging to the service. 3. To optionally define how to forward those frames in the data-path. The association of a service instance to an EVC depicts an instance of an Ethernet flow on a particular interface for an end-to-end (UNI-to-UNI) Ethernet service for a subscriber. The following diagram illustrates the association of EVC, UNIs and service instances. UNI physical ports are depicted as 'U', and service instances as 'x'. CE MEN MEN CE - - | | | | () | | | | | |Ux x||x xU| | | | | | () | | | | - - ^ ^ | | EVC - This MIB module addresses the functional areas of network management for EVC, including: The operational mode for interfaces that are providing Ethernet service(s). The service attributes regarding an interface behaving as UNI, such as CE-VLAN mapping and layer 2 control protocol (eg. stp, vtp, cdp) processing. The provisioning of service instances to define flow points for an Ethernet service. The operational status of EVCs for notifications of status changes, and EVC creation and deletion. Definition of terms and acronyms: B-Tag: Backbone Tag field in Ethernet 802.1ah frame CE: Customer Edge CE-VLAN: Customer Edge VLAN CoS: Class Of Service EVC: Ethernet Virtual Connection I-SID: Service Instance Identifier field in Ethernet 802.1ah frame MAC: Media Access Control MEN: Metro Ethernet Network NNI: Network to Network Interface OAM: Operations Administration and Management PPPoE: Point-to-Point Protocol over Ethernet Service frame: An Ethernet frame transmitted across the UNI toward the service provider or an Ethernet frame transmitted across the UNI toward the Subscriber. Service Instance: A flow point of an Ethernet service Service provider: The organization providing Ethernet service(s). Subscriber: The organization purchasing and/or using Ethernet service(s). UNI: User Network Interface The physical demarcation point between the responsibility of the service provider and the responsibility of the Subscriber. UNI-C: User Network Interface, subscriber side UNI-N: User Network Interface, service provider side VLAN: Virtual Local Area Network

cevcPortTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.2.1

This table provides the operational mode and configuration limitations of the physical interfaces (ports) that provide Ethernet services for the MEN. This table has a sparse depedent relationship on the ifTable, containing a row for each ifEntry having an ifType of 'ethernetCsmacd' capable of supporting Ethernet services.

cevcUniTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.2.2

This table contains a list of UNIs locally configured on the system. This table has a sparse dependent relationship on the cevcPortTable, containing a row for each cevcPortEntry having a cevcPortMode column value 'uni'.

cevcPortL2ControlProtocolTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.2.3

This table lists the layer 2 control protocol processing attributes at UNI ports. This table has an expansion dependent relationship on the cevcUniTable, containing zero or more rows for each UNI.

cevcUniCEVlanEvcTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.2.4

This table contains for each UNI, a list of EVCs and the association of CE-VLANs to the EVC. The CE-VLAN mapping is locally significant to the UNI. This table has an expansion dependent relationship on the cevcUniTable, containing zero or more rows for each UNI.

cevcEvcTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.3.1

This table contains a list of EVCs and their service attributes.

cevcEvcStateTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.3.2

This table lists statical/status data of the EVC. This table has an one-to-one dependent relationship on the cevcEvcTable, containing a row for each EVC.

cevcEvcUniTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.3.3

This table contains a list of UNI's for each EVC configured on the device. The UNIs can be local (i.e. physically located on the system) or remote (i.e. not physically located on the device). For local UNIs, the UNI Id is the same as denoted by cevcUniIdentifier with the same ifIndex value as cevcEvcLocalUniIfIndex. For remote UNIs, the underlying OAM protocol, if capable, provides the UNI Id via its protocol messages. This table has an expansion dependent relationship on the cevcEvcTable, containing a row for each UNI that is in the EVC.

cevcSITableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.4.1

This table lists each service instance and its service attributes.

cevcSIStateTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.4.2

This table lists statical status data of the service instance. This table has an one-to-one dependent relationship on the cevcSITable, containing a row for each service instance.

cevcSIVlanRewriteTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.4.3

This table lists the rewrite adjustments of the service frame's VLAN tags for service instances. This table has an expansion dependent relationship on the cevcSITable, containing a row for a VLAN adjustment for ingress and egress frames at each service instance.

cevcSIL2ControlProtocolTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.4.4

This table lists the layer 2 control protocol processing attributes at service instances. This table has an expansion dependent relationship on the cevcSITable, containing a row for each layer 2 control protocol disposition at each service instance.

cevcSICEVlanTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.4.5

This table contains the CE-VLAN map list for each Service Instance. This table has an expansion dependent relationship on the cevcSITable, containing a row for each CE-VLAN or a range of CE-VLANs that are mapped to a service instance.

cevcSIMatchCriteriaTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.4.6

This table contains the match criteria for each Service Instance. This table has an expansion dependent relationship on the cevcSITable, containing a row for each group of match criteria of each service instance.

cevcSIMatchEncapTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.4.7

This table contains the encapsulation based match criteria for each service instance. This table has a sparse dependent relationship on the cevcSIMatchCriteriaTable, containing a row for each match criteria having one of the following values for cevcSIMatchCriteriaType: - 'dot1q' - 'dot1ad' - 'untaggedAndDot1q' - 'untaggedAndDot1ad' - 'priorityTagged'

cevcSIPrimaryVlanTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.4.8

This table contains the primary VLAN ID list for each Service Instance. This table has an expansion dependent relationship on the cevcSIMatchEncapTable, containing zero or more rows for each encapsulation match criteria.

cevcSISecondaryVlanTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.4.9

This table contains the seconadary VLAN ID list for each service instance. This table has an expansion dependent relationship on the cevcSIMatchEncapTable, containing zero or more rows for each encapsulation match criteria.

cevcSIForwardBdTableSEQUENCEnot-accessible
.1.3.6.1.4.1.9.9.613.1.4.10

This table contains the forwarding bridge domain information for each service instance. This table has a sparse dependent relationship on the cevcSITable, containing a row for each service instance having a cevcSIForwardingType of 'bridgeDomain'.

cevcEvcStatusChangedNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.613.0.0.1

A device generates this notification when an EVC's operational status changes, or the number of active UNIs associated with the EVC (cevcNumActiveUnis) changes.

cevcEvcCreationNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.613.0.0.2

A device generates this notification upon the creation of an EVC.

cevcEvcDeletionNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.613.0.0.3

A device generates this notification upon the deletion of an EVC.

cevcMacSecurityViolationNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.9.9.613.0.0.4

A SNMP entity generates this notification in the following cases: When the system MAC Address limit is exceeded, the cevcMacSecurityViolationCauseType will contain 'exceedSystemLimit' value. When the Bridge domain limit is exceeded, the cevcMacSecurityViolationCauseType will contain 'exceedBdLimit' value. When the Service Instance limit is exceeded, the cevcMacSecurityViolationCauseType will contain 'exceedSILimit' value. If the MAC address is present in the Black list then cevcMacSecurityViolationCauseType will contain 'blackListDeny' value. Description of all the varbinds for this Notification is as follows: ifIndex indicates the interface index which identifies the interface that the service instance is attached. cevcSIForwardBdNumberBase indicates the base of bridge domain. The bridge domain range is 1~16k, this object is to track the base of each 4k bitmap. cevcSIForwardBdNumber1kBitmap indicates a string of octets containing one bit per Bridge domain per service instance. This 128-octet bitmap represents bridge domain ID values 0~1023. cevcSIForwardBdNumber2kBitmap indicates a string of octets containing one bit per Bridge domain per service instance. This 128-octet bitmap represents bridge domain ID values 1024~2047. cevcSIForwardBdNumber3kBitmap indicates a string of octets containing one bit per Bridge domain per service instance. This 128-octet bitmap represents bridge domain ID values 2048~3071. cevcSIForwardBdNumber4kBitmap indicates a string of octets containing one bit per Bridge domain per service instance. This 128-octet bitmap represents bridge domain ID values 3072~4095. cevcSIID indicates the service instance ID for the Mac security violation notification. cevcMacAddress indicates the Mac address which has violated the Mac security rules. cevcMaxMacConfigLimit indicates the maximum Mac configuration limit. This is also sent as a part of Mac security violation notification. cevcViolationCause indicates the Mac security violation cause.

cevcMacAddressMacAddressread-only
.1.3.6.1.4.1.9.9.613.1.6.1

This object indicates the MAC Address which has violated the Mac security rules.

cevcMaxMacConfigLimitUnsigned32read-write
.1.3.6.1.4.1.9.9.613.1.6.2

This object specifies the maximum MAC configuration limit. This is also sent as a part of MAC security violation notification. Every platform has their own forwarding table limitation. User can also set the maximum MAC configuration limit and if the limit set by user is not supported by platform then the object returns error.

More MIBs from Cisco

Browse all CiscoMIBs →
CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.

1401 objects→
CISCO-UNIFIED-COMPUTING-STORAGE-MIB

The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.

1295 objects→
CISCO-UNIFIED-COMPUTING-VNIC-MIB

The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.

1161 objects→
CERENT-GENERIC-MIB

SNMP MIB module

984 objects→
CISCO-UNIFIED-COMPUTING-BIOS-MIB

The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.

937 objects→
CISCO-UNIFIED-COMPUTING-ETHER-MIB

The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.

920 objects→