CISCO-ADSL-DMT-LINE-MIB
The CISCO-ADSL-DMT-LINE-MIB monitors Cisco-specific Discrete Multi-Tone (DMT) ADSL line characteristics, including aggregate data rates, bearer channel configurations, and per-bin signal-to-noise margins. It provides granular visibility into DMT-specific physical layer parameters such as symbol rates, line coding bin allocations, and error correction overhead distinct from the standard ADSL-LINE-MIB.
Imported Objects
Objects
58 total| Object Name |
|---|
ciscoAdslDmtLineMIB MODULE-IDENTITY .1.3.6.1.4.1.9.9.130 |
ciscoAdslDmtLineMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.130.1 |
cAdslDmtLineTable SEQUENCE OF CAdslDmtLineEntry .1.3.6.1.4.1.9.9.130.1.1 |
cAdslDmtLineEntry CAdslDmtLineEntry .1.3.6.1.4.1.9.9.130.1.1.1 |
cAdslDmtLineOverheadFramingro DmtOverheadFraming .1.3.6.1.4.1.9.9.130.1.1.1.1 |
cAdslAtucDmtPhysTable SEQUENCE OF CAdslAtucDmtPhysEntry .1.3.6.1.4.1.9.9.130.1.2 |
cAdslAtucDmtPhysEntry CAdslAtucDmtPhysEntry .1.3.6.1.4.1.9.9.130.1.2.1 |
cAdslAtucDmtStatero Enumeration .1.3.6.1.4.1.9.9.130.1.2.1.1 |
cAdslAtucDmtChanTable SEQUENCE OF CAdslAtucDmtChanEntry .1.3.6.1.4.1.9.9.130.1.4 |
cAdslAtucDmtChanEntry CAdslAtucDmtChanEntry .1.3.6.1.4.1.9.9.130.1.4.1 |
cAdslAtucDmtChanFecSizero DmtFecSize UNITS "bytes" .1.3.6.1.4.1.9.9.130.1.4.1.1 |
cAdslAtucDmtChanCodewordSizero DmtCodewordSize UNITS "symbols" .1.3.6.1.4.1.9.9.130.1.4.1.2 |
cAdslAturDmtChanTable SEQUENCE OF CAdslAturDmtChanEntry .1.3.6.1.4.1.9.9.130.1.5 |
cAdslAturDmtChanEntry CAdslAturDmtChanEntry .1.3.6.1.4.1.9.9.130.1.5.1 |
cAdslAturDmtChanFecSizero DmtFecSize UNITS "bytes" .1.3.6.1.4.1.9.9.130.1.5.1.1 |
cAdslAturDmtChanCodewordSizero DmtCodewordSize UNITS "symbols" .1.3.6.1.4.1.9.9.130.1.5.1.2 |
cAdslDmtLineConfProfileTable SEQUENCE OF CAdslDmtLineConfProfileEntry .1.3.6.1.4.1.9.9.130.1.14 |
cAdslDmtLineConfProfileEntry CAdslDmtLineConfProfileEntry .1.3.6.1.4.1.9.9.130.1.14.1 |
cAdslLineDmtConfOperatingModerw Enumeration .1.3.6.1.4.1.9.9.130.1.14.1.1 |
cAdslLineDmtConfTrainingModerw Enumeration .1.3.6.1.4.1.9.9.130.1.14.1.2 |
cAdslAtucDmtConfFastFecSizerw DmtFecSize UNITS "bytes" .1.3.6.1.4.1.9.9.130.1.14.1.3 |
cAdslAtucDmtConfInterleaveFecSizerw DmtFecSize UNITS "bytes" .1.3.6.1.4.1.9.9.130.1.14.1.4 |
cAdslAtucDmtConfCodewordSizerw DmtCodewordSize UNITS "symbols" .1.3.6.1.4.1.9.9.130.1.14.1.5 |
cAdslAtucDmtConfOverheadFramingrw DmtOverheadFraming .1.3.6.1.4.1.9.9.130.1.14.1.6 |
cAdslAtucDmtConfBitSwapEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.130.1.14.1.7 |
cAdslAtucDmtConfBitSwapFromrw Integer32 .1.3.6.1.4.1.9.9.130.1.14.1.8 |
cAdslAtucDmtConfBitSwapTorw Integer32 .1.3.6.1.4.1.9.9.130.1.14.1.9 |
cAdslAturDmtConfFastFecSizerw DmtFecSize UNITS "bytes" .1.3.6.1.4.1.9.9.130.1.14.1.10 |
cAdslAturDmtConfInterleaveFecSizerw DmtFecSize UNITS "bytes" .1.3.6.1.4.1.9.9.130.1.14.1.11 |
cAdslAturDmtConfCodewordSizerw DmtCodewordSize UNITS "symbols" .1.3.6.1.4.1.9.9.130.1.14.1.12 |
cAdslAtucDmtConfMinrateBlockrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.130.1.14.1.13 |
cAdslAtucDmtDualBitmapEnabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.9.9.130.1.14.1.14 |
cAdslDmtLineAlarmConfProfileTable SEQUENCE OF CAdslDmtLineAlarmConfProfileEntry .1.3.6.1.4.1.9.9.130.1.15 |
cAdslDmtLineAlarmConfProfileEntry CAdslDmtLineAlarmConfProfileEntry .1.3.6.1.4.1.9.9.130.1.15.1 |
cAdslAtucDmtThreshRateFallbackrw Integer32 .1.3.6.1.4.1.9.9.130.1.15.1.1 |
cAdslAturDmtThreshRateFallbackrw Integer32 .1.3.6.1.4.1.9.9.130.1.15.1.2 |
cAdslDmtBinIfNumberrw InterfaceIndexOrZero (IF-MIB) .1.3.6.1.4.1.9.9.130.1.16 |
cAdslDmtBinIfRqstStatusrw Enumeration .1.3.6.1.4.1.9.9.130.1.17 |
cAdslDmtBinIfLstRqstUpldTimero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.9.9.130.1.18 |
cAdslAtucDmtBinTable SEQUENCE OF CAdslAtucDmtBinEntry .1.3.6.1.4.1.9.9.130.1.19 |
cAdslAtucDmtBinEntry CAdslAtucDmtBinEntry .1.3.6.1.4.1.9.9.130.1.19.1 |
cAdslAtucDmtBitmapIndex Unsigned32 .1.3.6.1.4.1.9.9.130.1.19.1.1 |
cAdslAtucDmtBinIndex Unsigned32 .1.3.6.1.4.1.9.9.130.1.19.1.2 |
cAdslAtucDmtBinBitAllocro Unsigned32 .1.3.6.1.4.1.9.9.130.1.19.1.3 |
cAdslAtucDmtBinTxGainro Unsigned32 .1.3.6.1.4.1.9.9.130.1.19.1.4 |
cAdslAtucDmtBinNumberro Unsigned32 .1.3.6.1.4.1.9.9.130.1.19.1.5 |
cAdslAturDmtBinTable SEQUENCE OF CAdslAturDmtBinEntry .1.3.6.1.4.1.9.9.130.1.20 |
cAdslAturDmtBinEntry CAdslAturDmtBinEntry .1.3.6.1.4.1.9.9.130.1.20.1 |
cAdslAturDmtBitmapIndex Unsigned32 .1.3.6.1.4.1.9.9.130.1.20.1.1 |
cAdslAturDmtBinIndex Unsigned32 .1.3.6.1.4.1.9.9.130.1.20.1.2 |
cAdslAturDmtBinBitAllocro Unsigned32 .1.3.6.1.4.1.9.9.130.1.20.1.3 |
cAdslAturDmtBinTxGainro Unsigned32 .1.3.6.1.4.1.9.9.130.1.20.1.4 |
cAdslAturDmtBinNumberro Unsigned32 .1.3.6.1.4.1.9.9.130.1.20.1.5 |
ciscoAdslDmtLineMIBNotificationsPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.130.2 |
ciscoAdslDmtLineMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.130.2.0 |
ciscoAdslDmtLineMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.130.3 |
ciscoAdslDmtLineMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.130.3.1 |
ciscoAdslDmtLineMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.130.3.2 |
CISCO-ADSL-DMT-LINE-MIB Technical Reference Overview
The CISCO-ADSL-DMT-LINE-MIB SNMP MIB module published by Cisco defines 58 managed OID objects, including 35 scalar/column metrics, 8 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.9.9.130. Key tabular structures include cAdslDmtLineTable, cAdslAtucDmtPhysTable, cAdslAtucDmtChanTable, cAdslAturDmtChanTable, cAdslDmtLineConfProfileTable, cAdslDmtLineAlarmConfProfileTable.
Key OID Definitions in CISCO-ADSL-DMT-LINE-MIB
.1.3.6.1.4.1.9.9.130This MIB module serves as an enterprise-specific extension of the ADSL-LINE-MIB. The structure of this MIB module shadows the structure of the ADSL-LINE-MIB, table for table. The tables defined by this MIB module contain managed objects that meet the following criteria: 1) A managed object represents an attribute or characteristic specific to DMT (Digital Multi-Tone) modems. 2) The ADSL-DMT-LINE-MIB does not already contain a managed object representing the same information as a managed object. Observe that entries contained by the tables in this MIB module do not augment the corresponding entries in the ADSL-LINE-MIB, as every modem represented by the ADSL-LINE-MIB is not necessarily a DMT modem. Also observe that entries contained by the tables in this MIB module do not augment the corresponding entries in the ADSL-DMT-LINE-MIB, as this assumes that the ADSL-DMT-LINE-MIB defines tables that correspond to every table defined by the ADSL-LINE-MIB. At this time, this assumption does not hold true. *** DEFINITIONS *** AGGREGATE DATA RATE Data rate transmitted by an ADSL system in any one direction. This includes both net data rates and overhead used by the system, including: - EOC - AOC (ADSL Overhead Control channel) - CRC (Cyclic Redundancy Check) check bytes - fixed indicator bits for OAM (Operatings, Administration, and Maintenance) - synchronization control bytes - capacity for bearer channel synchronization control BEARER CHANNEL A user data stream of a specific data rate that is transported transparently by an ADSL system over one of the simplex channels (i.e., AS0, AS1, AS2, or AS3) or one of the duplex channels (i.e., LS0, LS1, or LS2). BIN DMT line coding divides the frequency spectrum above the voice band of a line (i.e., 0-4 kHz) into 255 sub-carriers, each supporting 4.3125 kHz of bandwidth. A 'bin' refers to a single sub-carrier. DATA SYMBOL RATE The average symbol rate (after allowing for the overhead of the sync symbol) at which symbols carrying data are transmitted; that is, 4000 symbols/second. DOWNSTREAM The flow of data in the direction from the ATU-C to ATU-R. LINE RATE The total data rate supported by a line; that is, (sum of b(i) for all i) * 4 kbps. MARGIN (also referred to as 'SNR margin') The difference between the SNR of the received signal and the SNR required to provide a BER of 10E-7. NET DATA RATE The data rate that is available for user data in any one direction; for the downstream direction this is the sum of the simplex and duplex bearer channel rates. SPLITTER Filters that separate the high frequency signals (ADSL) from the voice band signals; (frequently called POTS splitters even though the voice band signals may comprise more than just POTS). SYMBOL The number of bits the transmitter is capable of multiplexing and modulating over all the bins in a single signalling interval. SYMBOL RATE The rate at which all symbols, including the sync symbol, are transmitted; that is, (69/68) * 4000 symbols/sec; contrasted with the data symbol rate. TOTAL DATA RATE The aggregate data rate (q.v.) plus Reed-Solomon FEC overhead. UPSTREAM The flow of data in the direction from the ATU-R to ATU-C. *** ABBREVIATIONS, ACRONYMS, AND SYMBOLS *** ADSL - Asymmetric Digital Subscriber Line. ATM - Asynchronous Transfer Mode. ATU-C - ADSL Transceiver Unit, Central Office end. ATU-R - ADSL Transceiver Unit, Remote terminal end. b(i) - the number of bits (i.e., constellation size) modulated on bin i. BER - Bit Error Ratio. DMT - Discrete MultiTone. DSL - Digital Subscriber Line. EOC - Embedded Operations Channel. FEC - Forward Error Correction. SNR - Signal-to-Noise Ratio. STM - Synchronous Transfer Mode.
.1.3.6.1.4.1.9.9.130.1.1This table extends the adslLineTable and contains enterprise- specific common attributes describing both ends of ADSL lines supported by the system.
.1.3.6.1.4.1.9.9.130.1.2This table extends the adslAtucPhysTable and contains enterprise-specific physical layer parameters for ATU-C class devices supported by the system.
.1.3.6.1.4.1.9.9.130.1.4This table extends the adslAtucChanTable and contains enterprise-specific physical layer parameters for the ATU-C channels supported by the system.
.1.3.6.1.4.1.9.9.130.1.5This table extends the adslAturChanTable and contains enterprise-specific physical layer parameters for the ATU-R channels supported by the system.
.1.3.6.1.4.1.9.9.130.1.14This table extends the adslLineConfProfileTable and contains enterprise-specific ADSL DMT line configuration information.
.1.3.6.1.4.1.9.9.130.1.15This table extends the adslLineAlarmConfProfileTable and contains enterprise-specific ADSL line configuration information pertaining to alarms.
.1.3.6.1.4.1.9.9.130.1.19This table contains information on the 256 DMT bins in the downstream direction. Bins correspond to 4 kHz slots on a trained DSL line modem. The information stored in each bin includes bit counts per hertz of bandwidth and the transmitter gain in 0.01 dB increments.
.1.3.6.1.4.1.9.9.130.1.20This table contains information for the 32 DMT bins in the upstream direction. A bin corresponds to a 4 kHz slots on a trained DSL line modem. The information stored in each bin includes bit counts per hertz and the transmitter gain in 0.01 dB increments.
.1.3.6.1.4.1.9.9.130.1.16The cAdslDmtBinIfNumber is used to set the ifIndex for for which DMT bin information will be collected in cAdslAtucDmtBinTable and cAdslAturDmtBinTable. The request will be processed when cAdslDmtIfRqstStatus is set to pollNow (1). Setting this object will fail if the value of cAdslDmtIfRqstStatus is currently rqstInProgress (3). In addition, the interface must have an ifEntry with an ifType of adsl(94) and an adslLineCoding of dmt(2).
.1.3.6.1.4.1.9.9.130.1.17This object initiates the polling and stores the status of the last DMT Bin request. This object can have the following values : reset (-1) : write this value to reset the the finite state machine (FSM) that controls the reading of bin information on a DMT interface. pollNow (1) : write this value to begin bin polling on an interface specified in cAdslDmtBinIfNumber. noIfConfigured(2) : status read when no valid interface is set in cAdslDmtBinIfNumber ifConfigured(3) : status read when a valid interface is set in cAdslDmtBinIfNumber rqstInProgress(4) : status returned until the data collection is complete on an interface. lcDownForIf (5) : status returned if the line card is down for the interface. ifUntrained (6) : status returned if the interface on the DSLAM is untrained. failure (7) : status returned when the request cannot be completed due to error. success (8) : status returned when bin data collection has been properly completed. Data collected on a status of success (8) will be available in cAdslAtucDmtBinTable and cAdslAturDmtBinTable. A read of this object can return any value between 2 and 8, while a write can only be set to the value of 1 or -1.
.1.3.6.1.4.1.9.9.130.1.18cAdslDmtBinIfLstRqstUpldTime stores the time and date when the last successful upload request was done. This field is used to determine the age of DMT Bin data in the cAdslAtucDmtBinTable and cAdslAturDmtBinTable.
.1.3.6.1.4.1.9.9.130.1.1.1A set of enterprise-specific common attributes describing both ends of an ADSL line supported by the system. There exists an entry for each ifEntry with an ifType of adsl(94).
.1.3.6.1.4.1.9.9.130.1.1.1.1This object represents the negotiated overhead framing structure being used by the ATU-C and ATU-R.
.1.3.6.1.4.1.9.9.130.1.2.1A set of enterprise-specific physical-layer parameters for an ATU-C class device supported by the system. There exists an entry for each ifEntry with an ifType of adsl(94).
.1.3.6.1.4.1.9.9.130.1.2.1.1The value of this object specifies the enterprise-specific specific status of the ATU-C. If the value of adslAtucDMTState is not 'other', then the value of this object is 'standard'. If the value of adslAtucDMTState is 'other', and the ATU-C is in an unrecognized state, then the value of this object is 'unknown'. If the value of adslAtucDMTState is 'other', and the ATU-C is not in an unrecognized state, then the value of this object specifies the enterprise-specific state of the ATU-C.
.1.3.6.1.4.1.9.9.130.1.4.1A set of enterprise-specific physical-layer parameters for an ATU-C channel supported by the system. There exists an entry for each ifEntry with an ifType of adslInterleave(124) or adslFast(125).
.1.3.6.1.4.1.9.9.130.1.4.1.1This object specifies the number of FEC redundancy bytes the ATU-C appends to downstream on the corresponding channel. The ATU-C can fallback from the initial value specified for the corresponding channel (i.e., cAdslAtucDmtConfFastFecSize or cAdslAtucInterleaveFecSize) based on the aggregate data rate rate achieved during training.
.1.3.6.1.4.1.9.9.130.1.4.1.2This object specifies the actual number of symbols per codeword being used by the ATU-C for downstream messages. The ATU-C and ATU-R negotiate this value during the training sequence. A value of 0 indicates the automatic mode.
.1.3.6.1.4.1.9.9.130.1.5.1A set of enterprise-specific physical-layer parameters for an ATU-R channel supported by the system. There exists an entry for each ifEntry with an ifType of adslInterleave(124) or adslFast(125).
.1.3.6.1.4.1.9.9.130.1.5.1.1This object specifies the number of FEC redundancy bytes the ATU-R appends to upstream on the corresponding channel. The ATU-C can fallback from the initial value specified for the corresponding channel (i.e., cAdslAturDmtConfFastFecSize or cAdslAturInterleaveFecSize) based on the aggregate data rate achieved during training.
.1.3.6.1.4.1.9.9.130.1.5.1.2This object specifies the actual number of symbols per codeword being used by the ATU-R for upstream messages. The ATU-C and ATU-R negotiate this value during the training sequence.
.1.3.6.1.4.1.9.9.130.1.14.1A configuration profile containing enterprise-specific ADSL DMT line configuration information.
.1.3.6.1.4.1.9.9.130.1.14.1.1This object specifies the line operating mode being employed by the ADSL line. An ADSL line uses of one of two operating modes: - Automatic An ATU-C that employs this operating mode automatically detects the capabilities of the ATU-R and utilizes either a startup sequence specified by G.992.1, G.992.2, or T1.413-1998. This line operating mode is the default for an ADSL line. - Splitterless This operating mode should no longer be used. It is equivalent to the G.992.2 selection. Selecting this mode will automatically map to the G992.2 mode. It is appropriate in this case that both the ATU-C and ATU-R support 'heavy' capability but the ATU-C side wishes to force 'lite' operation. Selecting this mode will automatically convert to the G992.2 mode. - G992.1 This operating mode forces the used of the G994.1 startup sequence and compliance to G992.1 operation. - G992.2 This operating mode forces the use of the G994.1 startup sequence and compliance to G992.2 operation. It is appropriate in this case that both the ATU-C and ATU-R support 'heavy' capability but the ATU-C side wishes to force 'lite' operation. - T1.413 This operating mode forces the ATU-R to use the T1.413-1998 startup sequence.
More MIBs from Cisco
Browse all CiscoMIBs →The CISCO-UNIFIED-COMPUTING-COMPUTE-MIB provides SNMP-based monitoring and management of Cisco UCS compute blades, servers, and chassis components, exposing critical metrics such as CPU utilization, memory usage, thermal sensor readings, power supply status, and interface operational states. This module enables granular visibility into the health and performance of the Cisco Unified Computing System's compute subsystems for capacity planning and fault isolation.
The CISCO-UNIFIED-COMPUTING-STORAGE-MIB facilitates SNMP-based monitoring and management of storage subsystems, including Fibre Channel and iSCSI interfaces, within the Cisco Unified Computing System (UCS) fabric interconnects and blade servers. It exposes critical operational metrics such as port status, error counters, throughput statistics, and storage controller health states to enable granular visibility into the storage infrastructure.
The CISCO-UNIFIED-COMPUTING-VNIC-MIB enables SNMP-based monitoring and management of Virtual Network Interface Card (vNIC) attributes, including operational status, traffic counters, and binding configurations, within the Cisco Unified Computing System (UCS) fabric interconnects and server blades.
SNMP MIB module
The CISCO-UNIFIED-COMPUTING-BIOS-MIB enables SNMP-based monitoring and configuration of BIOS-level parameters, firmware versions, and hardware initialization states within Cisco Unified Computing System (UCS) servers. It provides visibility into critical server boot diagnostics, BIOS settings, and hardware readiness indicators to facilitate low-level infrastructure management and troubleshooting.
The CISCO-UNIFIED-COMPUTING-ETHER-MIB provides SNMP management interfaces for monitoring Ethernet interface statistics, link states, and error counters on Cisco Unified Computing System (UCS) fabric interconnects and blade server line cards. This module enables the tracking of physical layer connectivity, port throughput, and packet error rates within the UCS Ethernet switching infrastructure.