Home/Catalog/CISCO-ACCESS-ENVMON-MIB

CISCO-ACCESS-ENVMON-MIB

AI MIB Summary

The CISCO-ACCESS-ENVMON-MIB enables SNMP-based monitoring of environmental telemetry, including temperature, voltage, and fan status, on Cisco Access Network devices equipped with an integrated Environmental Monitor. This module provides critical hardware health data for proactive fault detection and thermal management within the access layer infrastructure.

The MIB module to describe the additional status of the Environmental Monitor on those Cisco Access devices which support one.
15
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

15 total
Object Name
ciscoAccessEnvMonMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.61
IMPORTS
Unknown
.1.3.6.1.4.1.9.9.61
caemObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.61.1
caemSupplyStatusTableThe table contains the additional power supply information that are not covered in the ciscoEnvMonSupplyStatusTable of CISCO-ENVMON-MIB.
SEQUENCE OF CaemSupplyStatusEntry
.1.3.6.1.4.1.9.9.61.1.1
caemSupplyStatusEntryAdditional information about the failure component or location in the power Supply beyond that provided by Cisco Environmental Monitor MIB's ciscoEnvMonSupplyStatusEntry.
CaemSupplyStatusEntry
.1.3.6.1.4.1.9.9.61.1.1.1
caemSupplyFailedComponentThe failure component of the power supply being instrumented. none - No failure. inputVoltage - Input power lost in one of the power supplies dcOutputVoltage - DC output voltage lost in one of the power supplies thermal - Power supply thermal failure. multiple - Multiple failures. fan - Fan failure overvoltage - Over voltage.ro
Enumeration
.1.3.6.1.4.1.9.9.61.1.1.1.1
caemMIBNotificationPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.61.2
caemMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.61.2.0
caemTemperatureNotificationA caemTemperatureNotification is sent if the over temperature condition is detected in the managed system. This is a replacement for the ciscoEnvMonTemperatureNotification trap because the information 'ciscoEnvMonTemperatureStatusValue' required by the trap is not available in the managed system.
TRAP-TYPE
.1.3.6.1.4.1.9.9.61.2.0.1
caemVoltageNotificationA caemVoltageNotification is sent if the over voltage condition is detected and ciscoEnvMonVoltageState is not set to 'notPresent' in the managed system. This is a replacement for the ciscoEnvMonVoltageNotification trap because the information 'ciscoEnvMonVoltageStatusValue' required by the trap is not available in the managed system.
TRAP-TYPE
.1.3.6.1.4.1.9.9.61.2.0.2
caemConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.61.3
caemCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.61.3.1
caemCompliance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.61.3.1.1
caemGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.61.3.2
caemGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.61.3.2.1