CISCO-ACCESS-ENVMON-MIB
AI MIB Summary
The CISCO-ACCESS-ENVMON-MIB enables SNMP-based monitoring of environmental telemetry, including temperature, voltage, and fan status, on Cisco Access Network devices equipped with an integrated Environmental Monitor. This module provides critical hardware health data for proactive fault detection and thermal management within the access layer infrastructure.
The MIB module to describe the additional status of the Environmental Monitor on those Cisco Access devices which support one.
15
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
15 total| Object Name |
|---|
ciscoAccessEnvMonMIB OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.61 |
IMPORTS Unknown .1.3.6.1.4.1.9.9.61 |
caemObjects OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.61.1 |
caemSupplyStatusTableThe table contains the additional power supply information
that are not covered in the ciscoEnvMonSupplyStatusTable of
CISCO-ENVMON-MIB. SEQUENCE OF CaemSupplyStatusEntry .1.3.6.1.4.1.9.9.61.1.1 |
caemSupplyStatusEntryAdditional information about the failure component or location
in the power Supply beyond that provided by Cisco Environmental
Monitor MIB's ciscoEnvMonSupplyStatusEntry. CaemSupplyStatusEntry .1.3.6.1.4.1.9.9.61.1.1.1 |
caemSupplyFailedComponentThe failure component of the power supply being instrumented.
none - No failure.
inputVoltage - Input power lost in one of the power supplies
dcOutputVoltage - DC output voltage lost in one of the power supplies
thermal - Power supply thermal failure.
multiple - Multiple failures.
fan - Fan failure
overvoltage - Over voltage.ro Enumeration .1.3.6.1.4.1.9.9.61.1.1.1.1 |
caemMIBNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.61.2 |
caemMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.61.2.0 |
caemTemperatureNotificationA caemTemperatureNotification is sent if the over temperature
condition is detected in the managed system.
This is a replacement for the ciscoEnvMonTemperatureNotification
trap because the information 'ciscoEnvMonTemperatureStatusValue'
required by the trap is not available in the managed system. TRAP-TYPE .1.3.6.1.4.1.9.9.61.2.0.1 |
caemVoltageNotificationA caemVoltageNotification is sent if the over voltage
condition is detected and ciscoEnvMonVoltageState is not set
to 'notPresent' in the managed system.
This is a replacement for the ciscoEnvMonVoltageNotification
trap because the information 'ciscoEnvMonVoltageStatusValue'
required by the trap is not available in the managed system. TRAP-TYPE .1.3.6.1.4.1.9.9.61.2.0.2 |
caemConformance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.61.3 |
caemCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.61.3.1 |
caemCompliance OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.61.3.1.1 |
caemGroups OBJECT IDENTIFIER .1.3.6.1.4.1.9.9.61.3.2 |