CISCO-ENVMON-MIB

AI MIB Summary

The CISCO-ENVMON-MIB enables SNMP-based monitoring of Cisco hardware environmental conditions, specifically tracking temperature sensors, fan module status, and power supply voltages to detect thermal anomalies or hardware failures.

The MIB module to describe the status of the Environmental Monitor on those devices which support one.
Main OID:
ciscoEnvMonMIB.1.3.6.1.4.1.9.9.13
53
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

53 total
Object Name
ciscoEnvMonMIBThe MIB module to describe the status of the Environmental Monitor on those devices which support one.
MODULE-IDENTITY
.1.3.6.1.4.1.9.9.13
ciscoEnvMonObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.13.1
ciscoEnvMonPresentThe type of environmental monitor located in the chassis. An oldAgs environmental monitor card is identical to an ags environmental card except that it is not capable of supplying data, and hence no instance of the remaining objects in this MIB will be returned in response to an SNMP query. Note that only a firmware upgrade is required to convert an oldAgs into an ags card.ro
Enumeration
.1.3.6.1.4.1.9.9.13.1.1
ciscoEnvMonVoltageStatusTableThe table of voltage status maintained by the environmental monitor.
SEQUENCE OF CiscoEnvMonVoltageStatusEntry
.1.3.6.1.4.1.9.9.13.1.2
ciscoEnvMonVoltageStatusEntryAn entry in the voltage status table, representing the status of the associated testpoint maintained by the environmental monitor.
CiscoEnvMonVoltageStatusEntry
.1.3.6.1.4.1.9.9.13.1.2.1
ciscoEnvMonVoltageStatusIndexUnique index for the testpoint being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning.
Integer32
.1.3.6.1.4.1.9.9.13.1.2.1.1
ciscoEnvMonVoltageStatusDescrTextual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.ro
DisplayString
.1.3.6.1.4.1.9.9.13.1.2.1.2
ciscoEnvMonVoltageStatusValueThe current measurement of the testpoint being instrumented.ro
CiscoSignedGauge UNITS "millivolts"
.1.3.6.1.4.1.9.9.13.1.2.1.3
ciscoEnvMonVoltageThresholdLowThe lowest value that the associated instance of the object ciscoEnvMonVoltageStatusValue may obtain before an emergency shutdown of the managed device is initiated.ro
Integer32 UNITS "millivolts"
.1.3.6.1.4.1.9.9.13.1.2.1.4
ciscoEnvMonVoltageThresholdHighThe highest value that the associated instance of the object ciscoEnvMonVoltageStatusValue may obtain before an emergency shutdown of the managed device is initiated.ro
Integer32 UNITS "millivolts"
.1.3.6.1.4.1.9.9.13.1.2.1.5
ciscoEnvMonVoltageLastShutdownThe value of the associated instance of the object ciscoEnvMonVoltageStatusValue at the time an emergency shutdown of the managed device was last initiated. This value is stored in non-volatile RAM and hence is able to survive the shutdown.ro
Integer32 UNITS "millivolts"
.1.3.6.1.4.1.9.9.13.1.2.1.6
ciscoEnvMonVoltageStateThe current state of the testpoint being instrumented.ro
CiscoEnvMonState
.1.3.6.1.4.1.9.9.13.1.2.1.7
ciscoEnvMonTemperatureStatusTableThe table of ambient temperature status maintained by the environmental monitor.
SEQUENCE OF CiscoEnvMonTemperatureStatusEntry
.1.3.6.1.4.1.9.9.13.1.3
ciscoEnvMonTemperatureStatusEntryAn entry in the ambient temperature status table, representing the status of the associated testpoint maintained by the environmental monitor.
CiscoEnvMonTemperatureStatusEntry
.1.3.6.1.4.1.9.9.13.1.3.1
ciscoEnvMonTemperatureStatusIndexUnique index for the testpoint being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning.
Integer32
.1.3.6.1.4.1.9.9.13.1.3.1.1
ciscoEnvMonTemperatureStatusDescrTextual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.ro
DisplayString
.1.3.6.1.4.1.9.9.13.1.3.1.2
ciscoEnvMonTemperatureStatusValueThe current measurement of the testpoint being instrumented.ro
Gauge32 UNITS "degrees Celsius"
.1.3.6.1.4.1.9.9.13.1.3.1.3
ciscoEnvMonTemperatureThresholdThe highest value that the associated instance of the object ciscoEnvMonTemperatureStatusValue may obtain before an emergency shutdown of the managed device is initiated.ro
Integer32 UNITS "degrees Celsius"
.1.3.6.1.4.1.9.9.13.1.3.1.4
ciscoEnvMonTemperatureLastShutdownThe value of the associated instance of the object ciscoEnvMonTemperatureStatusValue at the time an emergency shutdown of the managed device was last initiated. This value is stored in non-volatile RAM and hence is able to survive the shutdown.ro
Integer32 UNITS "degrees Celsius"
.1.3.6.1.4.1.9.9.13.1.3.1.5
ciscoEnvMonTemperatureStateThe current state of the testpoint being instrumented.ro
CiscoEnvMonState
.1.3.6.1.4.1.9.9.13.1.3.1.6
ciscoEnvMonFanStatusTableThe table of fan status maintained by the environmental monitor.
SEQUENCE OF CiscoEnvMonFanStatusEntry
.1.3.6.1.4.1.9.9.13.1.4
ciscoEnvMonFanStatusEntryAn entry in the fan status table, representing the status of the associated fan maintained by the environmental monitor.
CiscoEnvMonFanStatusEntry
.1.3.6.1.4.1.9.9.13.1.4.1
ciscoEnvMonFanStatusIndexUnique index for the fan being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning.
Integer32
.1.3.6.1.4.1.9.9.13.1.4.1.1
ciscoEnvMonFanStatusDescrTextual description of the fan being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.ro
DisplayString
.1.3.6.1.4.1.9.9.13.1.4.1.2
ciscoEnvMonFanStateThe current state of the fan being instrumented.ro
CiscoEnvMonState
.1.3.6.1.4.1.9.9.13.1.4.1.3
ciscoEnvMonSupplyStatusTableThe table of power supply status maintained by the environmental monitor card.
SEQUENCE OF CiscoEnvMonSupplyStatusEntry
.1.3.6.1.4.1.9.9.13.1.5
ciscoEnvMonSupplyStatusEntryAn entry in the power supply status table, representing the status of the associated power supply maintained by the environmental monitor card.
CiscoEnvMonSupplyStatusEntry
.1.3.6.1.4.1.9.9.13.1.5.1
ciscoEnvMonSupplyStatusIndexUnique index for the power supply being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning.
Integer32
.1.3.6.1.4.1.9.9.13.1.5.1.1
ciscoEnvMonSupplyStatusDescrTextual description of the power supply being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.ro
DisplayString
.1.3.6.1.4.1.9.9.13.1.5.1.2
ciscoEnvMonSupplyStateThe current state of the power supply being instrumented.ro
CiscoEnvMonState
.1.3.6.1.4.1.9.9.13.1.5.1.3
ciscoEnvMonSupplySourceThe power supply source. unknown - Power supply source unknown ac - AC power supply dc - DC power supply externalPowerSupply - External power supply internalRedundant - Internal redundant power supplyro
Enumeration
.1.3.6.1.4.1.9.9.13.1.5.1.4
ciscoEnvMonAlarmContactsEach bit is set to reflect the respective alarm being set. The bit will be cleared when the respective alarm is cleared.ro
Bits
.1.3.6.1.4.1.9.9.13.1.6
ciscoEnvMonMIBNotificationEnables
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.13.2
ciscoEnvMonEnableShutdownNotificationThis variable indicates whether the system produces the ciscoEnvMonShutdownNotification. A false value will prevent shutdown notifications from being generated by this system.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.13.2.1
ciscoEnvMonEnableVoltageNotificationThis variable indicates whether the system produces the ciscoEnvMonVoltageNotification. A false value will prevent voltage notifications from being generated by this system. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif.rwdeprecated
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.13.2.2
ciscoEnvMonEnableTemperatureNotificationThis variable indicates whether the system produces the ciscoEnvMonTemperatureNotification. A false value prevents temperature notifications from being sent by this entity. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif.rwdeprecated
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.13.2.3
ciscoEnvMonEnableFanNotificationThis variable indicates whether the system produces the ciscoEnvMonFanNotification. A false value prevents fan notifications from being sent by this entity. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif.rwdeprecated
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.13.2.4
ciscoEnvMonEnableRedundantSupplyNotificationThis variable indicates whether the system produces the ciscoEnvMonRedundantSupplyNotification. A false value prevents redundant supply notifications from being generated by this system. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif.rwdeprecated
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.13.2.5
ciscoEnvMonEnableStatChangeNotifThis variable indicates whether the system produces the ciscoEnvMonVoltStatusChangeNotif, ciscoEnvMonTempStatusChangeNotif, ciscoEnvMonFanStatusChangeNotif and ciscoEnvMonSuppStatusChangeNotif. A false value will prevent these notifications from being generated by this system.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.9.9.13.2.6
ciscoEnvMonMIBNotificationPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.13.3
ciscoEnvMonMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.13.3.0
ciscoEnvMonShutdownNotificationA ciscoEnvMonShutdownNotification is sent if the environmental monitor detects a testpoint reaching a critical state and is about to initiate a shutdown. This notification contains no objects so that it may be encoded and sent in the shortest amount of time possible. Even so, management applications should not rely on receiving such a notification as it may not be sent before the shutdown completes.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.13.3.0.1
ciscoEnvMonVoltageNotificationA ciscoEnvMonVoltageNotification is sent if the voltage measured at a given testpoint is outside the normal range for the testpoint (i.e. is at the warning, critical, or shutdown stage). Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonVoltStatusChangeNotif.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.13.3.0.2
ciscoEnvMonTemperatureNotificationA ciscoEnvMonTemperatureNotification is sent if the temperature measured at a given testpoint is outside the normal range for the testpoint (i.e. is at the warning, critical, or shutdown stage). Since such a Notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonTempStatusChangeNotif.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.13.3.0.3
ciscoEnvMonFanNotificationA ciscoEnvMonFanNotification is sent if any one of the fans in the fan array (where extant) fails. Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonFanStatusChangeNotif.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.13.3.0.4
ciscoEnvMonRedundantSupplyNotificationA ciscoEnvMonRedundantSupplyNotification is sent if the redundant power supply (where extant) fails. Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonSuppStatusChangeNotif.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.13.3.0.5
ciscoEnvMonVoltStatusChangeNotifA ciscoEnvMonVoltStatusChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonVoltageState.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.13.3.0.6
ciscoEnvMonTempStatusChangeNotifA ciscoEnvMonTempStatusChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonTemperatureState.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.13.3.0.7
ciscoEnvMonFanStatusChangeNotifA ciscoEnvMonFanStatusChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonFanState.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.13.3.0.8
ciscoEnvMonSuppStatusChangeNotifA ciscoEnvMonSupplyStatChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonSupplyState.
NOTIFICATION-TYPE
.1.3.6.1.4.1.9.9.13.3.0.9
ciscoEnvMonMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.13.4
ciscoEnvMonMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.13.4.1
ciscoEnvMonMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.9.9.13.4.2