AT-PLUGGABLE-DIAGNOSTICS-MIB

AI MIB Summary

The AT-PLUGGABLE-DIAGNOSTICS-MIB enables SNMP-based retrieval of standard diagnostic parameters, including optical power levels, temperature, and voltage, from installed Small Form-factor Pluggable (SFP) transceivers on Allied Telesis networking equipment.

The AT Pluggbale Diagnostics MIB contains objects to retrieve the standard diagnostic information from installed SFP modules.
Main OID:
atPluggableDiag.1.3.6.1.4.1.207.8.4.4.3.28
62
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

62 total
Object Name
atPluggableDiag
MODULE-IDENTITY
.1.3.6.1.4.1.207.8.4.4.3.28
atPluggableDiagTable
OBJECT IDENTIFIER
.1.3.6.1.4.1.207.8.4.4.3.28.1
atPluggableDiagTempTable
SEQUENCE OF AtPluggableDiagTempEntry
.1.3.6.1.4.1.207.8.4.4.3.28.1.1
atPluggableDiagTempEntry
AtPluggableDiagTempEntry
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1
atPluggableDiagTempIfIndex
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.1
atPluggableDiagTempChannel
Integer32
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.2
atPluggableDiagTempStatusReadingro
Integer32 UNITS "0.001 degree C"
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.3
atPluggableDiagTempCurrentAlarmro
OCTET STRING
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.4
atPluggableDiagTempAlarmMaxro
Integer32 UNITS "0.001 degree C"
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.5
atPluggableDiagTempAlarmMinro
Integer32 UNITS "0.001 degree C"
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.6
atPluggableDiagTempCurrentWarningro
OCTET STRING
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.7
atPluggableDiagTempWarningMaxro
Integer32 UNITS "0.001 degree C"
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.8
atPluggableDiagTempWarningMinro
Integer32 UNITS "0.001 degree C"
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.9
atPluggableDiagVccTable
SEQUENCE OF AtPluggableDiagVccEntry
.1.3.6.1.4.1.207.8.4.4.3.28.1.2
atPluggableDiagVccEntry
AtPluggableDiagVccEntry
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1
atPluggableDiagVccIfIndex
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.1
atPluggableDiagVccChannel
Integer32
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.2
atPluggableDiagVccStatusReadingro
Integer32 UNITS "0.0001 volts"
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.3
atPluggableDiagVccCurrentAlarmro
OCTET STRING
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.4
atPluggableDiagVccAlarmMaxro
Integer32 UNITS "0.0001 volts"
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.5
atPluggableDiagVccAlarmMinro
Integer32 UNITS "0.0001 volts"
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.6
atPluggableDiagVccCurrentWarningro
OCTET STRING
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.7
atPluggableDiagVccWarningMaxro
Integer32 UNITS "0.0001 volts"
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.8
atPluggableDiagVccWarningMinro
Integer32 UNITS "0.0001 volts"
.1.3.6.1.4.1.207.8.4.4.3.28.1.2.1.9
atPluggableDiagTxBiasTable
SEQUENCE OF AtPluggableDiagTxBiasEntry
.1.3.6.1.4.1.207.8.4.4.3.28.1.3
atPluggableDiagTxBiasEntry
AtPluggableDiagTxBiasEntry
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1
atPluggableDiagTxBiasIfIndex
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.1
atPluggableDiagTxBiasChannel
Integer32
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.2
atPluggableDiagTxBiasStatusReadingro
Integer32 UNITS "0.001 mA"
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.3
atPluggableDiagTxBiasCurrentAlarmro
OCTET STRING
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.4
atPluggableDiagTxBiasAlarmMaxro
Integer32 UNITS "0.001 mA"
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.5
atPluggableDiagTxBiasAlarmMinro
Integer32 UNITS "0.001 mA"
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.6
atPluggableDiagTxBiasCurrentWarningro
OCTET STRING
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.7
atPluggableDiagTxBiasWarningMaxro
Integer32 UNITS "0.001 mA"
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.8
atPluggableDiagTxBiasWarningMinro
Integer32 UNITS "0.001 mA"
.1.3.6.1.4.1.207.8.4.4.3.28.1.3.1.9
atPluggableDiagTxPowerTable
SEQUENCE OF AtPluggableDiagTxPowerEntry
.1.3.6.1.4.1.207.8.4.4.3.28.1.4
atPluggableDiagTxPowerEntry
AtPluggableDiagTxPowerEntry
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1
atPluggableDiagTxPowerIfIndex
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.1
atPluggableDiagTxPowerChannel
Integer32
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.2
atPluggableDiagTxPowerStatusReadingro
Integer32 UNITS "0.0001 mW"
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.3
atPluggableDiagTxPowerCurrentAlarmro
OCTET STRING
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.4
atPluggableDiagTxPowerAlarmMaxro
Integer32 UNITS "0.0001 mW"
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.5
atPluggableDiagTxPowerAlarmMinro
Integer32 UNITS "0.0001 mW"
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.6
atPluggableDiagTxPowerCurrentWarningro
OCTET STRING
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.7
atPluggableDiagTxPowerWarningMaxro
Integer32 UNITS "0.0001 mW"
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.8
atPluggableDiagTxPowerWarningMinro
Integer32 UNITS "0.0001 mW"
.1.3.6.1.4.1.207.8.4.4.3.28.1.4.1.9
atPluggableDiagRxPowerTable
SEQUENCE OF AtPluggableDiagRxPowerEntry
.1.3.6.1.4.1.207.8.4.4.3.28.1.5
atPluggableDiagRxPowerEntry
AtPluggableDiagRxPowerEntry
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1
atPluggableDiagRxPowerIfIndex
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.1
atPluggableDiagRxPowerChannel
Integer32
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.2
atPluggableDiagRxPowerStatusReadingro
Integer32 UNITS "0.0001 mW"
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.3
atPluggableDiagRxPowerCurrentAlarmro
OCTET STRING
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.4
atPluggableDiagRxPowerAlarmMaxro
Integer32 UNITS "0.0001 mW"
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.5
atPluggableDiagRxPowerAlarmMinro
Integer32 UNITS "0.0001 mW"
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.6
atPluggableDiagRxPowerCurrentWarningro
OCTET STRING
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.7
atPluggableDiagRxPowerWarningMaxro
Integer32 UNITS "0.0001 mW"
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.8
atPluggableDiagRxPowerWarningMinro
Integer32 UNITS "0.0001 mW"
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.9
atPluggableDiagRxLosTable
SEQUENCE OF AtPluggableDiagRxLosEntry
.1.3.6.1.4.1.207.8.4.4.3.28.1.6
atPluggableDiagRxLosEntry
AtPluggableDiagRxLosEntry
.1.3.6.1.4.1.207.8.4.4.3.28.1.6.1
atPluggableDiagRxLosIfIndex
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.1
atPluggableDiagRxLosChannel
Integer32
.1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.2
atPluggableDiagRxLosStatusReadingro
OCTET STRING
.1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.3

AT-PLUGGABLE-DIAGNOSTICS-MIB Technical Reference Overview

The AT-PLUGGABLE-DIAGNOSTICS-MIB SNMP MIB module published by Allied Telesis defines 62 managed OID objects, including 48 scalar/column metrics, 6 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.207.8.4.4.3.28. Key tabular structures include atPluggableDiagRxLosTable, atPluggableDiagRxPowerTable, atPluggableDiagTempTable, atPluggableDiagTxBiasTable, atPluggableDiagTxPowerTable, atPluggableDiagVccTable.

Key OID Definitions in AT-PLUGGABLE-DIAGNOSTICS-MIB

atPluggableDiagMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.207.8.4.4.3.28

The AT Pluggbale Diagnostics MIB contains objects to retrieve the standard diagnostic information from installed SFP modules.

atPluggableDiagRxLosTableSEQUENCEnot-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.6

A table of information regarding the Rx Loss of Singal (Los) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.

atPluggableDiagRxPowerTableSEQUENCEnot-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.5

A table of information regarding the various Rx Power (mW) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.

atPluggableDiagTempTableSEQUENCEnot-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.1

A table of information regarding the various temperature parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.

atPluggableDiagTxBiasTableSEQUENCEnot-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.3

A table of information regarding the various Tx Bias Current (mA) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.

atPluggableDiagTxPowerTableSEQUENCEnot-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.4

A table of information regarding the various Tx Power (mW) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.

atPluggableDiagVccTableSEQUENCEnot-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.2

A table of information regarding the various Voltage (Vcc) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices.

atPluggableDiagRxLosChannelInteger32(1..16)not-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.2

The channel number of the pluggable.

atPluggableDiagRxLosEntryAtPluggableDiagRxLosEntrynot-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.6.1

The information about various Rx Loss of Singal (Los) parameters of pluggables such as current status reading.

atPluggableDiagRxLosIfIndexInterfaceIndexnot-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.1

The ifindex of the pluggable.

atPluggableDiagRxLosStatusReadingOCTETread-only
.1.3.6.1.4.1.207.8.4.4.3.28.1.6.1.3

The current Rx Los status reading.

atPluggableDiagRxPowerAlarmMaxInteger32read-only
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.5

The maximum Rx Power (mW) alarm threshold value.

atPluggableDiagRxPowerAlarmMinInteger32read-only
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.6

The minimum Rx Power (mW) alarm threshold value.

atPluggableDiagRxPowerChannelInteger32(1..16)not-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.2

The channel number of the pluggable.

atPluggableDiagRxPowerCurrentAlarmOCTETread-only
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.4

The current Rx Power (mW) alarm reading.

atPluggableDiagRxPowerCurrentWarningOCTETread-only
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.7

The current Rx Power (mW) warnings.

atPluggableDiagRxPowerEntryAtPluggableDiagRxPowerEntrynot-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1

The information about various Rx Power (mW) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold.

atPluggableDiagRxPowerIfIndexInterfaceIndexnot-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.1

The ifindex of the pluggable.

atPluggableDiagRxPowerStatusReadingInteger32read-only
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.3

The current Rx Power (mW) status reading.

atPluggableDiagRxPowerWarningMaxInteger32read-only
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.8

The maximum Rx Power (mW) warning threshold value.

atPluggableDiagRxPowerWarningMinInteger32read-only
.1.3.6.1.4.1.207.8.4.4.3.28.1.5.1.9

The minimum Rx Power (mW) warning threshold value.

atPluggableDiagTempAlarmMaxInteger32read-only
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.5

The maximum temperature alarm threshold value.

atPluggableDiagTempAlarmMinInteger32read-only
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.6

The minimum temperature alarm threshold value.

atPluggableDiagTempChannelInteger32(1..16)not-accessible
.1.3.6.1.4.1.207.8.4.4.3.28.1.1.1.2

The channel number of the pluggable.

More MIBs from Allied Telesis

Browse all Allied TelesisMIBs →
AT-UWC-WLAN-SWITCH-MIB

The AT-UWC-WLAN-SWITCH-MIB provides vendor-specific SNMP management for Allied Telesis Universal Wireless Controller (UWC) hardware, enabling monitoring of WLAN switch operational states, interface statistics, and wireless client association metrics.

1459 objects→
AtiEdgeSwitch-MIB

The AtiEdgeSwitch-MIB provides vendor-specific SNMP extensions for monitoring and managing Layer 2 stackable switch operations, including interface status, port statistics, and stack topology, on ATI hardware platforms within Windows and UNIX network management environments.

924 objects→
ALLIEDTELESYN-MIB

Standard SNMP MIB module defining data structures for ALLIEDTELESYN-MIB.

772 objects→
AT-BOARDS-MIB

The AT-BOARDS-MIB module provides a structured OID hierarchy for monitoring and managing specific hardware components on Allied Telesis devices, including board identifiers, firmware release versions, interface type definitions, and integrated chip IDs. This MIB enables granular inventory tracking and hardware status verification by mapping logical identifiers to physical subsystems within the network equipment chassis.

328 objects→
SWITCH-ATM-MIB

SWITCH-ATM-MIB monitors and manages Asynchronous Transfer Mode (ATM) interfaces and virtual circuit states on network switches, specifically tracking VPI/VCI pairings and traffic counters under the constraint that the Virtual Path Identifier is fixed by the implementation and excluded from table indexing.

263 objects→
AtiL2-MIB

Standard SNMP MIB module defining data structures for AtiL2-MIB.

239 objects→