Home/Catalog/ZYXEL-PPPoE-MIB

ZYXEL-PPPoE-MIB

The subtree for Point-to-Point Protocol over Ethernet (PPPoE)
Main OID:
zyxelPppoe.1.3.6.1.4.1.890.1.15.3.67
29
Objects
Active
Status
14
Dependencies

Imported Objects

Objects

29 total
Object Name
zyxelPppoeThe subtree for Point-to-Point Protocol over Ethernet (PPPoE)
MODULE-IDENTITY
.1.3.6.1.4.1.890.1.15.3.67
RFC1155-SMIThe subtree for Point-to-Point Protocol over Ethernet (PPPoE)
Unknown
.1.3.6.1.4.1.890.1.15.3.67
IF-MIBThe subtree for Point-to-Point Protocol over Ethernet (PPPoE)
NOTIFICATION-TYPE
.1.3.6.1.4.1.890.1.15.3.67
zyxelPppoeIaSetup
OBJECT IDENTIFIER
.1.3.6.1.4.1.890.1.15.3.67.1
zyPppoeIaStateEnable/Disable PPPoE intermediate agent globally on the switch.rw
EnabledStatus (P-BRIDGE-MIB)
.1.3.6.1.4.1.890.1.15.3.67.1.1
zyPppoeIaAccessNodeIdStringUp to 20 alphanumeric characters to identify the PPPoE intermediate agent. Hyphens and spaces are also allowed. The default is the switch's host name.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.15.3.67.1.2
zyPppoeIaFlexibleCircuitIdSyntaxStateEnable/Disable this if you want the switch to add the user-defined identifier string and variables to PADI and PADR packets from PPPoE clients.rw
EnabledStatus (P-BRIDGE-MIB)
.1.3.6.1.4.1.890.1.15.3.67.1.3
zyPppoeIaFlexibleCircuitIdSyntaxIdStringSpecify a string that the switch adds in the agent Circuit ID sub-option.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.15.3.67.1.4
zyPppoeIaFlexibleCircuitIdSyntaxOptionSelect the variables that you want the switch to generate and add in the agnet circuit ID sub-option. The variable options include sp, sv,pv and spv which indicate combinations of slot-port, slot-VLAN, port-VLAN and slot-port-VLAN respectively.rw
Enumeration
.1.3.6.1.4.1.890.1.15.3.67.1.5
zyPppoeIaFlexibleCircuitIdSyntaxDelimiterSelect a delimiter to spearate the identifier-string, slot ID, port number and/or VLAN ID from each other.rw
Enumeration
.1.3.6.1.4.1.890.1.15.3.67.1.6
zyxelPppoeIaPortTableThe table contains PPPoE intermediate agent on the specified port configuration.
SEQUENCE OF ZyxelPppoeIaPortEntry
.1.3.6.1.4.1.890.1.15.3.67.1.7
zyxelPppoeIaPortEntryAn entry contains PPPoE intermediate agent on the specified port configuration
ZyxelPppoeIaPortEntry
.1.3.6.1.4.1.890.1.15.3.67.1.7.1
zyPppoeIaPortTrustStateEnable/Disable trusted port on the specified port. Trusted ports are uplink ports connected to PPPoE servers. If a PADO (PPPoE Active Discovery Offer), PADS (PPPoE Active Discovery Session-confirmation), or PADT (PPPoE Active Discovery Terminate) packet is sent from a PPPoE server and received on a trusted port, the Switch forwards it to all other ports. If a PADI or PADR packet is sent from a PPPoE client but received on a trusted port, the Switch forwards it to other trusted port(s). Untrusted ports are downlink ports connected to subscribers. If a PADI, PADR, or PADT packet is sent from a PPPoE client and received on an untrusted port, the Switch adds a vendor-specific tag to the packet and then forwards it to the trusted port(s). The Switch discards PADO and PADS packets which are sent from a PPPoE server but received on an untrusted port.rw
EnabledStatus (P-BRIDGE-MIB)
.1.3.6.1.4.1.890.1.15.3.67.1.7.1.1
zyPppoeIaPortCircuitIdStringEnter a string of up to 63 ASCII characters that the switch adds into the Agent Circuit ID sub-option for PPPoE discovery packets received on this port. Spaces are allowed.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.15.3.67.1.7.1.2
zyPppoeIaPortRemoteIdStringEnter a string of up to 63 ASCII characters that the switch adds into the Agent Remote ID sub-option for PPPoE discovery packets received on this port. Space are allows. If you do not specify a string here or in the Remote-id field for a VLAN on a port, the Switch automatically uses the PPPoE clients MAC address.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.15.3.67.1.7.1.3
zyPppoeIaMaxNumberOfVlansThe maximum number of PPPoE IA vlan entries that can be created.ro
INTEGER
.1.3.6.1.4.1.890.1.15.3.67.1.8
zyxelPppoeIaVlanTableThe table contains PPPoE intermediate agent for the specified VLAN configuration.
SEQUENCE OF ZyxelPppoeIaVlanEntry
.1.3.6.1.4.1.890.1.15.3.67.1.9
zyxelPppoeIaVlanEntryAn entry contains PPPoE intermediate agent for the specified VLAN configuration.
ZyxelPppoeIaVlanEntry
.1.3.6.1.4.1.890.1.15.3.67.1.9.1
zyPppoeIaVlanVidVLAN ID you want to configure.
INTEGER
.1.3.6.1.4.1.890.1.15.3.67.1.9.1.1
zyPppoeIaVlanCircuitIdStateEnable/Disable circuit ID setting for a specific VLAN take effectrw
EnabledStatus (P-BRIDGE-MIB)
.1.3.6.1.4.1.890.1.15.3.67.1.9.1.2
zyPppoeIaVlanRemoteIdStateEnable/Disable remote ID settings for a specific VLAN take effect.rw
EnabledStatus (P-BRIDGE-MIB)
.1.3.6.1.4.1.890.1.15.3.67.1.9.1.3
zyPppoeIaVlanRowStatusThis object allows entries to be created and deleted from the PPPoE IA VLAN table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.890.1.15.3.67.1.9.1.4
zyPppoeIaMaxNumberOfPortVlansThe maximum number of PPPoE IA per port per vlan entries that can be created.ro
INTEGER
.1.3.6.1.4.1.890.1.15.3.67.1.10
zyxelPppoeIaPortVlanTableThe table contains PPPoE intermediate agent for the specified VLAN on the specified port configuration.
SEQUENCE OF ZyxelPppoeIaPortVlanEntry
.1.3.6.1.4.1.890.1.15.3.67.1.11
zyxelPppoeIaPortVlanEntryAn entry contains PPPoE intermediate agent for the specified VLAN on the specified port configuration
ZyxelPppoeIaPortVlanEntry
.1.3.6.1.4.1.890.1.15.3.67.1.11.1
zyPppoeIaPortVlanVidVLAN ID you want to configure.
INTEGER
.1.3.6.1.4.1.890.1.15.3.67.1.11.1.1
zyPppoeIaPortVlanCircuitIdStringA string of up to 63 ASCII characters that the switch adds into the agent circuit ID sub-option for PPPoE discovery packets received on this VLAN on the specified port. The circuit ID you configure for a specific VLAN on a port has the highest priority.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.15.3.67.1.11.1.2
zyPppoeIaPortVlanRemoteIdStringA string of up to 63 ASCII characters that the switch adds into the agent remote ID sub-option for PPPoE discovery packets received on this VLAN on the specified port. If you do not specify a string here or in the Remote-id field for a specific port, the Switch automatically uses the PPPoE clients MAC address. The remote ID you configure for a specific VLAN on a port has the highest priority.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.890.1.15.3.67.1.11.1.3
zyPppoeIaPortVlanRowStatusThis object allows entries to be created and deleted from the PPPoE IA port VLAN table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.890.1.15.3.67.1.11.1.4
ZYXEL-PPPoE-MIB - SNMP MIB Reference | MIBs Explorer