ZYXEL-PPPoE-MIB
The subtree for Point-to-Point Protocol over Ethernet (PPPoE)
Main OID:
zyxelPppoe.1.3.6.1.4.1.890.1.15.3.67
29
Objects
Active
Status
14
Dependencies
Imported Objects
Objects
29 total| Object Name |
|---|
zyxelPppoeThe subtree for Point-to-Point Protocol over Ethernet (PPPoE) MODULE-IDENTITY .1.3.6.1.4.1.890.1.15.3.67 |
RFC1155-SMIThe subtree for Point-to-Point Protocol over Ethernet (PPPoE) Unknown .1.3.6.1.4.1.890.1.15.3.67 |
IF-MIBThe subtree for Point-to-Point Protocol over Ethernet (PPPoE) NOTIFICATION-TYPE .1.3.6.1.4.1.890.1.15.3.67 |
zyxelPppoeIaSetup OBJECT IDENTIFIER .1.3.6.1.4.1.890.1.15.3.67.1 |
zyPppoeIaStateEnable/Disable PPPoE intermediate agent globally on the switch.rw EnabledStatus (P-BRIDGE-MIB) .1.3.6.1.4.1.890.1.15.3.67.1.1 |
zyPppoeIaAccessNodeIdStringUp to 20 alphanumeric characters to identify the PPPoE intermediate agent.
Hyphens and spaces are also allowed. The default is the switch's host name.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.15.3.67.1.2 |
zyPppoeIaFlexibleCircuitIdSyntaxStateEnable/Disable this if you want the switch to add the user-defined identifier string and
variables to PADI and PADR packets from PPPoE clients.rw EnabledStatus (P-BRIDGE-MIB) .1.3.6.1.4.1.890.1.15.3.67.1.3 |
zyPppoeIaFlexibleCircuitIdSyntaxIdStringSpecify a string that the switch adds in the agent Circuit ID sub-option.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.15.3.67.1.4 |
zyPppoeIaFlexibleCircuitIdSyntaxOptionSelect the variables that you want the switch to generate and add in the agnet circuit
ID sub-option. The variable options include sp, sv,pv and spv which indicate combinations
of slot-port, slot-VLAN, port-VLAN and slot-port-VLAN respectively.rw Enumeration .1.3.6.1.4.1.890.1.15.3.67.1.5 |
zyPppoeIaFlexibleCircuitIdSyntaxDelimiterSelect a delimiter to spearate the identifier-string, slot ID, port number and/or VLAN ID from each other.rw Enumeration .1.3.6.1.4.1.890.1.15.3.67.1.6 |
zyxelPppoeIaPortTableThe table contains PPPoE intermediate agent on the specified port configuration. SEQUENCE OF ZyxelPppoeIaPortEntry .1.3.6.1.4.1.890.1.15.3.67.1.7 |
zyxelPppoeIaPortEntryAn entry contains PPPoE intermediate agent on the specified port configuration ZyxelPppoeIaPortEntry .1.3.6.1.4.1.890.1.15.3.67.1.7.1 |
zyPppoeIaPortTrustStateEnable/Disable trusted port on the specified port.
Trusted ports are uplink ports connected to PPPoE servers.
If a PADO (PPPoE Active Discovery Offer), PADS (PPPoE Active Discovery Session-confirmation), or PADT (PPPoE Active Discovery Terminate) packet is sent from a PPPoE server and received on a trusted port, the Switch forwards it to all other ports.
If a PADI or PADR packet is sent from a PPPoE client but received on a trusted port, the Switch forwards it to other trusted port(s).
Untrusted ports are downlink ports connected to subscribers.
If a PADI, PADR, or PADT packet is sent from a PPPoE client and received on an untrusted port, the Switch adds a vendor-specific tag to the packet and then forwards it to the trusted port(s).
The Switch discards PADO and PADS packets which are sent from a PPPoE server but received on an untrusted port.rw EnabledStatus (P-BRIDGE-MIB) .1.3.6.1.4.1.890.1.15.3.67.1.7.1.1 |
zyPppoeIaPortCircuitIdStringEnter a string of up to 63 ASCII characters that the switch adds into the Agent Circuit ID
sub-option for PPPoE discovery packets received on this port. Spaces are allowed.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.15.3.67.1.7.1.2 |
zyPppoeIaPortRemoteIdStringEnter a string of up to 63 ASCII characters that the switch adds into the Agent Remote ID sub-option
for PPPoE discovery packets received on this port. Space are allows. If you do not specify a string
here or in the Remote-id field for a VLAN on a port, the Switch automatically uses the PPPoE clients
MAC address.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.15.3.67.1.7.1.3 |
zyPppoeIaMaxNumberOfVlansThe maximum number of PPPoE IA vlan entries that can be created.ro INTEGER .1.3.6.1.4.1.890.1.15.3.67.1.8 |
zyxelPppoeIaVlanTableThe table contains PPPoE intermediate agent for the specified VLAN configuration. SEQUENCE OF ZyxelPppoeIaVlanEntry .1.3.6.1.4.1.890.1.15.3.67.1.9 |
zyxelPppoeIaVlanEntryAn entry contains PPPoE intermediate agent for the specified VLAN configuration. ZyxelPppoeIaVlanEntry .1.3.6.1.4.1.890.1.15.3.67.1.9.1 |
zyPppoeIaVlanVidVLAN ID you want to configure. INTEGER .1.3.6.1.4.1.890.1.15.3.67.1.9.1.1 |
zyPppoeIaVlanCircuitIdStateEnable/Disable circuit ID setting for a specific VLAN take effectrw EnabledStatus (P-BRIDGE-MIB) .1.3.6.1.4.1.890.1.15.3.67.1.9.1.2 |
zyPppoeIaVlanRemoteIdStateEnable/Disable remote ID settings for a specific VLAN take effect.rw EnabledStatus (P-BRIDGE-MIB) .1.3.6.1.4.1.890.1.15.3.67.1.9.1.3 |
zyPppoeIaVlanRowStatusThis object allows entries to be created and deleted from the PPPoE IA VLAN table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.890.1.15.3.67.1.9.1.4 |
zyPppoeIaMaxNumberOfPortVlansThe maximum number of PPPoE IA per port per vlan entries that can be created.ro INTEGER .1.3.6.1.4.1.890.1.15.3.67.1.10 |
zyxelPppoeIaPortVlanTableThe table contains PPPoE intermediate agent for the specified VLAN on the specified port configuration. SEQUENCE OF ZyxelPppoeIaPortVlanEntry .1.3.6.1.4.1.890.1.15.3.67.1.11 |
zyxelPppoeIaPortVlanEntryAn entry contains PPPoE intermediate agent for the specified VLAN on the specified port configuration ZyxelPppoeIaPortVlanEntry .1.3.6.1.4.1.890.1.15.3.67.1.11.1 |
zyPppoeIaPortVlanVidVLAN ID you want to configure. INTEGER .1.3.6.1.4.1.890.1.15.3.67.1.11.1.1 |
zyPppoeIaPortVlanCircuitIdStringA string of up to 63 ASCII characters that the switch adds into the agent circuit ID sub-option for
PPPoE discovery packets received on this VLAN on the specified port. The circuit ID you configure for
a specific VLAN on a port has the highest priority.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.15.3.67.1.11.1.2 |
zyPppoeIaPortVlanRemoteIdStringA string of up to 63 ASCII characters that the switch adds into the agent remote ID sub-option for
PPPoE discovery packets received on this VLAN on the specified port. If you do not specify a string
here or in the Remote-id field for a specific port, the Switch automatically uses the PPPoE clients
MAC address. The remote ID you configure for a specific VLAN on a port has the highest priority.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.890.1.15.3.67.1.11.1.3 |
zyPppoeIaPortVlanRowStatusThis object allows entries to be created and deleted from the PPPoE IA port VLAN table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.890.1.15.3.67.1.11.1.4 |