Home/Catalog/WebGraph-Thermo-Hygrometer-US-MIB

WebGraph-Thermo-Hygrometer-US-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for WebGraph-Thermo-Hygrometer-US-MIB.

197
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

197 total
Object Name
wut
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040
IMPORTS
Unknown
.1.3.6.1.4.1.5040
wtComServer
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1
wtWebio
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2
wtWebGraphThermHygro
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9
wtWebGraphThermHygroAlert1This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.31
wtWebGraphThermHygroAlert2This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.32
wtWebGraphThermHygroAlert3This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.33
wtWebGraphThermHygroAlert4This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.34
wtWebGraphThermHygroAlert5This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.35
wtWebGraphThermHygroAlert6This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.36
wtWebGraphThermHygroAlert7This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.37
wtWebGraphThermHygroAlert8This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.38
wtWebGraphThermHygroAlert9This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.91
wtWebGraphThermHygroAlert10This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.92
wtWebGraphThermHygroAlert11This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.93
wtWebGraphThermHygroAlert12This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.94
wtWebGraphThermHygroAlert13This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.95
wtWebGraphThermHygroAlert14This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.96
wtWebGraphThermHygroAlert15This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.97
wtWebGraphThermHygroAlert16This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.98
wtWebGraphThermHygroAlertDiagThis SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled.
TRAP-TYPE
.1.3.6.1.4.1.5040.1.2.9.0.110
wtWebGraphThermHygroTemp
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.1
wtWebGraphThermHygroSensorsNumber of sensorsro
INTEGER
.1.3.6.1.4.1.5040.1.2.9.1.1
wtWebGraphThermHygroSensorTableList of sensors.
SEQUENCE OF WtWebGraphThermHygroSensorEntry
.1.3.6.1.4.1.5040.1.2.9.1.2
wtWebGraphThermHygroSensorEntryList of sensor numbers.
WtWebGraphThermHygroSensorEntry
.1.3.6.1.4.1.5040.1.2.9.1.2.1
wtWebGraphThermHygroSensorNoSensor number.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.9.1.2.1.1
wtWebGraphThermHygroTempValueTableList of measurement values corresponding to the channel numbers.
SEQUENCE OF WtWebGraphThermHygroTempValueEntry
.1.3.6.1.4.1.5040.1.2.9.1.3
wtWebGraphThermHygroTempValueEntryMeasurement values of the sensors.
WtWebGraphThermHygroTempValueEntry
.1.3.6.1.4.1.5040.1.2.9.1.3.1
wtWebGraphThermHygroTempValueMeasurement value of the sensor, ASCII, 5 characters in length.ro
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.1.3.1.1
wtWebGraphThermHygroBinaryTempValueTableList of binary measurement values corresponding to the channel numbers.
SEQUENCE OF WtWebGraphThermHygroBinaryTempValueEntry
.1.3.6.1.4.1.5040.1.2.9.1.4
wtWebGraphThermHygroBinaryTempValueEntryBinary measurement values of the sensors.
WtWebGraphThermHygroBinaryTempValueEntry
.1.3.6.1.4.1.5040.1.2.9.1.4.1
wtWebGraphThermHygroBinaryTempValueBinary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent, signed number, 0x4FFF6 indicates an invalid measured value.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.9.1.4.1.1
wtWebGraphThermHygroSessCntrl
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.2
wtWebGraphThermHygroSessCntrlPasswordEntering this password opens a session which is ended by writing a 1 to wtWebGraphThermHygroSessCntrlLogout. When read this variable provides a string of length zero.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.2.1
wtWebGraphThermHygroSessCntrlConfigModeWhen the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.ro
Enumeration
.1.3.6.1.4.1.5040.1.2.9.2.2
wtWebGraphThermHygroSessCntrlLogoutIf the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.2.3
wtWebGraphThermHygroSessCntrlAdminPasswordThis password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.2.4
wtWebGraphThermHygroSessCntrlConfigPasswordThis password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.2.5
wtWebGraphThermHygroConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3
wtWebGraphThermHygroDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1
wtWebGraphThermHygroText
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.1
wtWebGraphThermHygroDeviceNameName of the Webio, which is user definable.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.1.1
wtWebGraphThermHygroDeviceTextDescription of the Webio, which is user definable.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.1.2
wtWebGraphThermHygroDeviceLocationDescription of the location of the Webio, which is user definable.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.1.3
wtWebGraphThermHygroDeviceContactContact address of the system operator of the Webio, which is user definable.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.1.4
wtWebGraphThermHygroTimeDate
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.2
wtWebGraphThermHygroTimeZone
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1
wtWebGraphThermHygroTzOffsetHrsOffset hours for the time zone (winter time) with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.1
wtWebGraphThermHygroTzOffsetMinOffset minutes for the time zone (winter time) with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.2
wtWebGraphThermHygroTzEnableBinary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezonerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.3
wtWebGraphThermHygroStTzOffsetHrsOffset hours of the time zone (summer time) with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.4
wtWebGraphThermHygroStTzOffsetMinOffset minutes of the time zone (summer time) with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.5
wtWebGraphThermHygroStTzEnableBinary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertimerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.6
wtWebGraphThermHygroStTzStartMonthMonth in which the change is made from winter time to summer time.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.7
wtWebGraphThermHygroStTzStartModeMode of the day of the week for which the change is made from winter time to summer time.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.8
wtWebGraphThermHygroStTzStartWdayDay of the week on which the change is made from winter time to summer timerw
Enumeration
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.9
wtWebGraphThermHygroStTzStartHrsHour in which the time zone is changed from winter to summer time with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.10
wtWebGraphThermHygroStTzStartMinMinute in which the time zone is changed from winter to summer time with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.11
wtWebGraphThermHygroStTzStopMonthMonth in which the change is made from summer time to winter time.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.12
wtWebGraphThermHygroStTzStopModeMode of the week day on which the change is made from summer time to winter time.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.13
wtWebGraphThermHygroStTzStopWdayDay of the week on which the change is made from summer time to winter time.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.14
wtWebGraphThermHygroStTzStopHrsHour at which the time zone is changed from summer to winter time with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.15
wtWebGraphThermHygroStTzStopMinMinute at which the time zone is changed from summer to winter time with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.1.16
wtWebGraphThermHygroTimeServer
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.2
wtWebGraphThermHygroTimeServer1IP address or name of the 1st time server in ASCIIrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.2.2.1
wtWebGraphThermHygroTimeServer2IP address or name of the 2nd time server in ASCIIrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.2.2.2
wtWebGraphThermHygroTsEnableBinary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Serverrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.2.2.3
wtWebGraphThermHygroTsSyncTimeDaily synchronisation time with the time server (hour: 0-23).rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.2.4
wtWebGraphThermHygroDeviceClock
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.3
wtWebGraphThermHygroClockHrsClock hours taking into account the time zone settings.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.3.1
wtWebGraphThermHygroClockMinClock minutes taking into account the time zone settings.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.3.2
wtWebGraphThermHygroClockDayDate: Day of the month, taking into account the time zone settings.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.3.3
wtWebGraphThermHygroClockMonthDate: Month, taking into account the time zone settings.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.9.3.1.2.3.4
wtWebGraphThermHygroClockYearDate: Year, taking into account the time zone settings.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.2.3.5
wtWebGraphThermHygroBasic
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.3
wtWebGraphThermHygroNetwork
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.3.1
wtWebGraphThermHygroIpAddressIP address of the Webiorw
IpAddress
.1.3.6.1.4.1.5040.1.2.9.3.1.3.1.1
wtWebGraphThermHygroSubnetMaskSubnet mask of the Webiorw
IpAddress
.1.3.6.1.4.1.5040.1.2.9.3.1.3.1.2
wtWebGraphThermHygroGatewayGateway of the Webiorw
IpAddress
.1.3.6.1.4.1.5040.1.2.9.3.1.3.1.3
wtWebGraphThermHygroDnsServer1IP address of the 1st DNS server in ASCIIrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.1.4
wtWebGraphThermHygroDnsServer2IP address of the 2nd DNS server in ASCIIrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.1.5
wtWebGraphThermHygroAddConfigAdditional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: BOOTP disablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.1.6
wtWebGraphThermHygroHTTP
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.3.2
wtWebGraphThermHygroStartupBinary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.2.1
wtWebGraphThermHygroGetHeaderEnableIf this bit is set, every answer of a short form GET question will be lead by the IP-address and name of the device: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : GET Header enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.2.2
wtWebGraphThermHygroHttpPortDefinition of the standard HTML port (Default: 80).rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.3.2.3
wtWebGraphThermHygroMail
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.3.3
wtWebGraphThermHygroMailAdNameDevice name for mail administration.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.3.1
wtWebGraphThermHygroMailReplyReply address for the mail server.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.3.2
wtWebGraphThermHygroMailServerName or IP address of the mail server.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.3.3
wtWebioAn1MailEnableSet this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.3.4
wtWebGraphThermHygroMailAuthenticationSelection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authenticationrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.3.5
wtWebGraphThermHygroMailAuthUserName of the user to be authenticated.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.3.6
wtWebGraphThermHygroMailAuthPasswordAuthentication password.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.3.7
wtWebGraphThermHygroMailPop3ServerName or Ip-address of the POP3 Servers.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.3.8
wtWebGraphThermHygroSNMP
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.3.4
wtWebGraphThermHygroSnmpCommunityStringReadCommunity string read onlyrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.4.1
wtWebGraphThermHygroSnmpCommunityStringReadWriteCommunity string read / writerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.4.2
wtWebGraphThermHygroSystemTrapManagerIPName or IP address of the TCP server which accepts the system trap.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.4.3
wtWebGraphThermHygroSystemTrapEnableBinary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.4.4
wtWebGraphThermHygroSnmpEnableSet bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.4.5
wtWebGraphThermHygroSnmpCommunityStringTrapCommunity string send within traps.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.4.6
wtWebGraphThermHygroUDP
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.3.5
wtWebGraphThermHygroUdpPortUdp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.3.5.1
wtWebGraphThermHygroUdpEnableSet this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.5.2
wtWebGraphThermHygroSyslog
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.3.6
wtWebGraphThermHygroSyslogServerIPName or IP address of the Syslog server, which accepts the Syslog messgaes.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.6.1
wtWebGraphThermHygroSyslogServerPortPortnumber of the Syslog servers, default 514.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.3.6.2
wtWebGraphThermHygroSyslogSystemMessagesEnableBinary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.6.3
wtWebGraphThermHygroSyslogEnableSet bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.6.4
wtWebGraphThermHygroFTP
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.3.7
wtWebGraphThermHygroFTPServerIPName or IP address of the FTP server, which accepts the FTP messages.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.7.1
wtWebGraphThermHygroFTPServerControlPortPortnumber of the control port of the FTP server, default 21.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.3.7.2
wtWebGraphThermHygroFTPUserNameFTP Loggin: user name.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.7.3
wtWebGraphThermHygroFTPPasswordFTP Loggin: user password.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.7.4
wtWebGraphThermHygroFTPAccountFTP Loggin: name of account.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.7.5
wtWebGraphThermHygroFTPOptionBit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.7.6
wtWebGraphThermHygroFTPEnableSet Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.3.7.7
wtWebGraphThermHygroDatalogger
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.4
wtWebGraphThermHygroLoggerTimebaseTime base of the data loggerrw
Enumeration
.1.3.6.1.4.1.5040.1.2.9.3.1.4.1
wtWebGraphThermHygroLoggerSensorSelBinary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.4.2
wtWebGraphThermHygroDisplaySensorSelBinary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.4.3
wtWebGraphThermHygroSensorColorTableList of sensor colors for the praphical presentation.
SEQUENCE OF WtWebGraphThermHygroSensorColorEntry
.1.3.6.1.4.1.5040.1.2.9.3.1.4.4
wtWebGraphThermHygroSensorColorEntryIndex numbers of the sensors.
WtWebGraphThermHygroSensorColorEntry
.1.3.6.1.4.1.5040.1.2.9.3.1.4.4.1
wtWebGraphThermHygroSensorColorColor of the sensors at the praphical presention.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.4.4.1.1
wtWebGraphThermHygroAutoScaleEnableIf bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.4.5
wtWebGraphThermHygroVerticalUpperLimitThis value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.4.6
wtWebGraphThermHygroVerticalLowerLimitThis value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.4.7
wtWebGraphThermHygroHorizontalZoomDefines the default zoom stage, if no auto scaling is selected.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.9.3.1.4.8
wtWebGraphThermHygroAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.1.5
wtWebGraphThermHygroAlarmCountNumber of independent alarms.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.5.1
wtWebGraphThermHygroAlarmIfTableList of alarm indices.
SEQUENCE OF WtWebGraphThermHygroAlarmIfEntry
.1.3.6.1.4.1.5040.1.2.9.3.1.5.2
wtWebGraphThermHygroAlarmIfEntryNumbers of the alarms.
WtWebGraphThermHygroAlarmIfEntry
.1.3.6.1.4.1.5040.1.2.9.3.1.5.2.1
wtWebGraphThermHygroAlarmNoAlarm number.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.5.2.1.1
wtWebGraphThermHygroAlarmTableList of settings depending on the alarm number.
SEQUENCE OF WtWebGraphThermHygroAlarmEntry
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3
wtWebGraphThermHygroAlarmEntryAlarm parameters of the individual alarms.
WtWebGraphThermHygroAlarmEntry
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1
wtWebGraphThermHygroAlarmTriggerBinary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.1
wtWebGraphThermHygroAlarmMinMinimum temperature in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.2
wtWebGraphThermHygroAlarmMaxMaximum temperature in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.3
wtWebGraphThermHygroAlarmHysteresisTemperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.4
wtWebGraphThermHygroAlarmDelayAlarm will be delayed by setting this time while stable alarm condition occur (time in minutes).rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.5
wtWebGraphThermHygroAlarmIntervalSend interval for alarm messages.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.6
wtWebGraphThermHygroAlarmEnableBinary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.7
wtWebGraphThermHygroAlarmEMailAddrE-Mail address for sending the alarm mail to.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.8
wtWebGraphThermHygroAlarmMailSubjectSubject line for alarm mail.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.9
wtWebGraphThermHygroAlarmMailTextAlarm mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.10
wtWebGraphThermHygroAlarmManagerIPName or IP address of the SNMP Manager which accepts the trap.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.11
wtWebGraphThermHygroAlarmTrapTextThis text is sent in the trap body.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.12
wtWebGraphThermHygroAlarmMailOptionsBinary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.13
wtWebGraphThermHygroAlarmTcpIpAddrName or IP address of the TCP server which accepts the trap.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.14
wtWebGraphThermHygroAlarmTcpPortPort number of the TCP server which accepts the trap.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.15
wtWebGraphThermHygroAlarmTcpTextThis text is sent in the TCP trap body.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.16
wtWebGraphThermHygroAlarmClearMailSubjectSubject line for alarm clear mail.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.17
wtWebGraphThermHygroAlarmClearMailTextAlarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.18
wtWebGraphThermHygroAlarmClearTrapTextThis text is sent in the trap body.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.19
wtWebGraphThermHygroAlarmClearTcpTextThis text is sent in the TCP trap body.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.20
wtWebGraphThermHygroAlarmDeltaTempMaximum rate of change degrees/min with maximum 2 decimal places. Compared with the average of a period of 5 minutes.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.21
wtWebGraphThermHygroAlarmRHMinMinimum rel. Humidity in percent with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.22
wtWebGraphThermHygroAlarmRHMaxMaximum rel.Humidity in percent with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.23
wtWebGraphThermHygroAlarmRHHysteresisHysterese rel. Humidity in percent with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.24
wtWebGraphThermHygroAlarmAHMinMinimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.25
wtWebGraphThermHygroAlarmAHMaxMaximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.26
wtWebGraphThermHygroAlarmSyslogIpAddrIP address of the syslog server to which the Webio device should send syslog messages.rw
IpAddress
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.27
wtWebGraphThermHygroAlarmSyslogPortPort number of the syslog server to which the Webio device should send syslog messages.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.28
wtWebGraphThermHygroAlarmSyslogTextEvery message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.29
wtWebGraphThermHygroAlarmSyslogClearTextEvery message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.30
wtWebGraphThermHygroAlarmFtpDataPortLocal data port: 1..65535 or AUTO: the next free port will be assigned.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.31
wtWebGraphThermHygroAlarmFtpFileNameName of the file including path informations.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.32
wtWebGraphThermHygroAlarmFtpTextMessage text to store on the FTP server.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.33
wtWebGraphThermHygroAlarmFtpClearTextAlarm clear message to store on the FTP server.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.34
wtWebGraphThermHygroAlarmFtpOptionsBinary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.35
wtWebGraphThermHygroAlarmTimerCronThis entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.1.5.3.1.36
wtWebGraphThermHygroPorts
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.2
wtWebGraphThermHygroPortTableList of settings depending on the sensor number.
SEQUENCE OF WtWebGraphThermHygroPortEntry
.1.3.6.1.4.1.5040.1.2.9.3.2.1
wtWebGraphThermHygroPortEntrySensor parameters for the individual sensors.
WtWebGraphThermHygroPortEntry
.1.3.6.1.4.1.5040.1.2.9.3.2.1.1
wtWebGraphThermHygroPortNameName of the sensor.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.2.1.1.1
wtWebGraphThermHygroPortTextDescription of the sensor.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.2.1.1.2
wtWebGraphThermHygroPortOffset1Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.2.1.1.3
wtWebGraphThermHygroPortTemperature1Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.2.1.1.4
wtWebGraphThermHygroPortOffset2Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.2.1.1.5
wtWebGraphThermHygroPortTemperature2Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.2.1.1.6
wtWebGraphThermHygroPortCommentOffset calibration: informations of date, name of operator, reference devices.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.2.1.1.7
wtWebGraphThermHygroPortSensorSelectBinary coded options for sensor 1: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: unused Binary coded options for sensor 2: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : W&T Sensor rel. humidity (default) Bit 1 : Skalar 0-2.5V Bit 2 : Disconnect Bit 3-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.2.1.1.8
wtWebGraphThermHygroManufact
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.3.3
wtWebGraphThermHygroMfNameManufacturer company namerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.3.1
wtWebGraphThermHygroMfAddrManufacturer address.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.3.2
wtWebGraphThermHygroMfHotlineManufacturer hotline.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.3.3
wtWebGraphThermHygroMfInternetManufacturer Internet address.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.3.4
wtWebGraphThermHygroMfDeviceTypManufacturer device name (model number).rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.3.5
wtWebGraphThermHygroMfOrderNoManufacturer part number.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.3.3.6
wtWebGraphThermHygroDiag
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.9.4
wtWebGraphThermHygroDiagErrorCountNumber of entries in the error memory.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.9.4.1
wtWebGraphThermHygroDiagBinaryErrorError causes coded bit-by-bit.ro
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.4.2
wtWebGraphThermHygroDiagErrorIndexThe value of this variable is used as an index to read an error massege from wtWebGraphThermHygroDiagErrorMessage. Errors are numbered from 1 to wtWebGraphThermHygroDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebGraphThermHygroDiagErrorMessage.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.4.3
wtWebGraphThermHygroDiagErrorMessageUsing wtWebGraphThermHygroDiagErrorIndex as an index, the appropriate message is available.ro
OCTET STRING
.1.3.6.1.4.1.5040.1.2.9.4.4
wtWebGraphThermHygroDiagErrorClearWriting 1 into this variable clears all diagnosis messages.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.9.4.5
WebGraph-Thermo-Hygrometer-US-MIB - SNMP MIB Reference | MIBs Explorer