WebGraph-Thermometer-PT-US-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for WebGraph-Thermometer-PT-US-MIB.
501
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
501 total| Object Name |
|---|
wut OBJECT IDENTIFIER .1.3.6.1.4.1.5040 |
IMPORTS Unknown .1.3.6.1.4.1.5040 |
wtComServer OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1 |
wtWebio OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2 |
wtWebioAn1GraphPt OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17 |
wtWebioAn1GraphPtAlert1This SNMP trap is generated when Alarm 1 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.31 |
wtWebioAn1GraphPtAlert2This SNMP trap is generated when Alarm 2 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.32 |
wtWebioAn1GraphPtAlert3This SNMP trap is generated when Alarm 3 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.33 |
wtWebioAn1GraphPtAlert4This SNMP trap is generated when Alarm 4 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.34 |
wtWebioAn1GraphPtAlert5This SNMP trap is generated when Alarm 5 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.35 |
wtWebioAn1GraphPtAlert6This SNMP trap is generated when Alarm 6 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.36 |
wtWebioAn1GraphPtAlert7This SNMP trap is generated when Alarm 7 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.37 |
wtWebioAn1GraphPtAlert8This SNMP trap is generated when Alarm 8 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.38 |
wtWebioAn1GraphPtAlert9This SNMP trap is generated when Alarm 1 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.91 |
wtWebioAn1GraphPtAlert10This SNMP trap is generated when Alarm 2 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.92 |
wtWebioAn1GraphPtAlert11This SNMP trap is generated when Alarm 3 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.93 |
wtWebioAn1GraphPtAlert12This SNMP trap is generated when Alarm 4 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.94 |
wtWebioAn1GraphPtAlert13This SNMP trap is generated when Alarm 5 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.95 |
wtWebioAn1GraphPtAlert14This SNMP trap is generated when Alarm 6 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.96 |
wtWebioAn1GraphPtAlert15This SNMP trap is generated when Alarm 7 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.97 |
wtWebioAn1GraphPtAlert16This SNMP trap is generated when Alarm 8 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.98 |
wtWebioAn1GraphPtAlertDiagThis SNMP trap is generated when a diagnosis/error message was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.17.0.110 |
wtWebioAn1GraphPtTemp OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.1 |
wtWebioAn1GraphPtSensorsNumber of temperature sensorsro INTEGER (1) .1.3.6.1.4.1.5040.1.2.17.1.1 |
wtWebioAn1GraphPtSensorTableList of sensors. SEQUENCE OF WtWebioAn1GraphPtSensorEntry .1.3.6.1.4.1.5040.1.2.17.1.2 |
wtWebioAn1GraphPtSensorEntryTemperature sensor numbers. WtWebioAn1GraphPtSensorEntry .1.3.6.1.4.1.5040.1.2.17.1.2.1 |
wtWebioAn1GraphPtSensorNoTemperature sensor number.ro INTEGER (1) .1.3.6.1.4.1.5040.1.2.17.1.2.1.1 |
wtWebioAn1GraphPtTempValueTableList of temperature values corresponding to the channel numbers. SEQUENCE OF WtWebioAn1GraphPtTempValueEntry .1.3.6.1.4.1.5040.1.2.17.1.3 |
wtWebioAn1GraphPtTempValueEntryTemperatures of the sensors. WtWebioAn1GraphPtTempValueEntry .1.3.6.1.4.1.5040.1.2.17.1.3.1 |
wtWebioAn1GraphPtTempValueTemperature value of the sensor, ASCII, 5 characters in length.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.17.1.3.1.1 |
wtWebioAn1GraphPtBinaryTempValueTableList of binary temperature values corresponding to the channel numbers. SEQUENCE OF WtWebioAn1GraphPtBinaryTempValueEntry .1.3.6.1.4.1.5040.1.2.17.1.4 |
wtWebioAn1GraphPtBinaryTempValueEntryBinary temperature values of the sensors. WtWebioAn1GraphPtBinaryTempValueEntry .1.3.6.1.4.1.5040.1.2.17.1.4.1 |
wtWebioAn1GraphPtBinaryTempValueBinary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an
invalid measured value.ro INTEGER .1.3.6.1.4.1.5040.1.2.17.1.4.1.1 |
wtWebioAn1GraphPtTempValuePktTableList of temperature values corresponding to the channel numbers. SEQUENCE OF WtWebioAn1GraphPtTempValuePktEntry .1.3.6.1.4.1.5040.1.2.17.1.8 |
wtWebioAn1GraphPtTempValuePktEntryTemperatures of the sensors. WtWebioAn1GraphPtTempValuePktEntry .1.3.6.1.4.1.5040.1.2.17.1.8.1 |
wtWebioAn1GraphPtTempValuePktTemperature value of the sensor, ASCII, 5 characters in length, decimal point.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.17.1.8.1.1 |
wtWebioAn1GraphPtSessCntrl OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.2 |
wtWebioAn1GraphPtSessCntrlPasswordEntering this password opens a session which is ended by writing a 1 to
wtWebioAn1GraphPtSessCntrlLogout. When read this variable provides a string of
length zero.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.2.1 |
wtWebioAn1GraphPtSessCntrlConfigModeWhen the device is in SNMP configuration mode, the value 1 is
returned, otherwise 0. If the read value is 0 even though the
password was written, the device is already in config mode and the
variables can only be read.ro Enumeration .1.3.6.1.4.1.5040.1.2.17.2.2 |
wtWebioAn1GraphPtSessCntrlLogoutIf the device is in configuration mode and the session was opened by
this SNMP Manager, writing a 1 to this variable will end the session
and all parameters are stored.
Writing a 2 discards all entries again.
When read this variable provides the value 0.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.2.3 |
wtWebioAn1GraphPtSessCntrlAdminPasswordThis password protects access to the variables with administrator rights.
It can only be changed by the administrator. If no password was assigned,
the valid password is public.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.2.4 |
wtWebioAn1GraphPtSessCntrlConfigPasswordThis password protects access to the variables with configurator rights. It can
be changed by the administrator and by the configurator. If no password was assigned,
the valid password is public. When read this variable provides a null-pointer.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.2.5 |
wtWebioAn1GraphPtConfig OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3 |
wtWebioAn1GraphPtDevice OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1 |
wtWebioAn1GraphPtText OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.1 |
wtWebioAn1GraphPtDeviceNameName of the Webio, which is user definable.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.1.1 |
wtWebioAn1GraphPtDeviceTextDescription of the Webio, which is user definable.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.1.2 |
wtWebioAn1GraphPtDeviceLocationDescription of the location of the Webio, which is user definable.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.1.3 |
wtWebioAn1GraphPtDeviceContactContact address of the system operator of the Webio, which is user definable.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.1.4 |
wtWebioAn1GraphPtTimeDate OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.2 |
wtWebioAn1GraphPtTimeZone OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.2.1 |
wtWebioAn1GraphPtTzOffsetHrsOffset hours for the time zone (winter time) with respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.1 |
wtWebioAn1GraphPtTzOffsetMinOffset minutes for the time zone (winter time) with respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.2 |
wtWebioAn1GraphPtTzEnableBinary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Timezonerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.3 |
wtWebioAn1GraphPtStTzOffsetHrsOffset hours of the time zone (summer time) with respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.4 |
wtWebioAn1GraphPtStTzOffsetMinOffset minutes of the time zone (summer time) with respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.5 |
wtWebioAn1GraphPtStTzEnableBinary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Summertimerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.6 |
wtWebioAn1GraphPtStTzStartMonthMonth in which the change is made from winter time to summer time.rw Enumeration .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.7 |
wtWebioAn1GraphPtStTzStartModeMode of the day of the week for which the change is made from winter time to summer time.rw Enumeration .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.8 |
wtWebioAn1GraphPtStTzStartWdayDay of the week on which the change is made from winter time to summer timerw Enumeration .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.9 |
wtWebioAn1GraphPtStTzStartHrsHour in which the time zone is changed from winter to summer time with
respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.10 |
wtWebioAn1GraphPtStTzStartMinMinute in which the time zone is changed from winter to summer time with
respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.11 |
wtWebioAn1GraphPtStTzStopMonthMonth in which the change is made from summer time to winter time.rw Enumeration .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.12 |
wtWebioAn1GraphPtStTzStopModeMode of the week day on which the change is made from summer time to winter time.rw Enumeration .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.13 |
wtWebioAn1GraphPtStTzStopWdayDay of the week on which the change is made from summer time to winter time.rw Enumeration .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.14 |
wtWebioAn1GraphPtStTzStopHrsHour at which the time zone is changed from summer to winter time with
respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.15 |
wtWebioAn1GraphPtStTzStopMinMinute at which the time zone is changed from summer to winter time with
respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.1.16 |
wtWebioAn1GraphPtTimeServer OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.2.2 |
wtWebioAn1GraphPtTimeServer1IP address or name of the 1st time server in ASCIIrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.2.2.1 |
wtWebioAn1GraphPtTimeServer2IP address or name of the 2nd time server in ASCIIrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.2.2.2 |
wtWebioAn1GraphPtTsEnableBinary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Time Serverrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.2.2.3 |
wtWebioAn1GraphPtTsSyncTimeDaily synchronisation time with the time server (hour: 0-23).rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.2.4 |
wtWebioAn1GraphPtDeviceClock OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.2.3 |
wtWebioAn1GraphPtClockHrsClock hours taking into account the time zone settings.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.3.1 |
wtWebioAn1GraphPtClockMinClock minutes taking into account the time zone settings.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.3.2 |
wtWebioAn1GraphPtClockDayDate: Day of the month, taking into account the time zone settings.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.3.3 |
wtWebioAn1GraphPtClockMonthDate: Month, taking into account the time zone settings.rw Enumeration .1.3.6.1.4.1.5040.1.2.17.3.1.2.3.4 |
wtWebioAn1GraphPtClockYearDate: Year, taking into account the time zone settings.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.2.3.5 |
wtWebioAn1GraphPtBasic OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.3 |
wtWebioAn1GraphPtNetwork OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.3.1 |
wtWebioAn1GraphPtIpAddressIP address of the Webiorw IpAddress .1.3.6.1.4.1.5040.1.2.17.3.1.3.1.1 |
wtWebioAn1GraphPtSubnetMaskSubnet mask of the Webiorw IpAddress .1.3.6.1.4.1.5040.1.2.17.3.1.3.1.2 |
wtWebioAn1GraphPtGatewayGateway of the Webiorw IpAddress .1.3.6.1.4.1.5040.1.2.17.3.1.3.1.3 |
wtWebioAn1GraphPtDnsServer1IP address of the 1st DNS server in ASCIIrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.1.4 |
wtWebioAn1GraphPtDnsServer2IP address of the 2nd DNS server in ASCIIrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.1.5 |
wtWebioAn1GraphPtAddConfigAdditional configuration (1=ON):
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: DHCP disable
Bit 0: BOOTP disablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.1.6 |
wtWebioAn1GraphPtHTTP OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.3.2 |
wtWebioAn1GraphPtStartupBinary coded start page:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: Index.htm
Bit 2: Home.htm
Bit 3: User.htm
Only one page may be selected at a time.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.2.1 |
wtWebioAn1GraphPtGetHeaderEnableIf these bits are set, every answer of a short form GET question will be lead
by the IP-address and name of the device and/or a HTTP header:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-6: unused
Bit 1 : GET HTTP enable
Bit 0 : GET Header enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.2.2 |
wtWebioAn1GraphPtHttpPortDefinition of the standard HTML port (Default: 80).rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.3.2.3 |
wtWebioAn1GraphPtMail OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.3.3 |
wtWebioAn1GraphPtMailAdNameDevice name for mail administration.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.3.1 |
wtWebioAn1GraphPtMailReplyReply address for the mail server.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.3.2 |
wtWebioAn1GraphPtMailServerName or IP address of the mail server.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.3.3 |
wtWebioAn1GraphPtMailEnableSet this bit to enable the sending of mails:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Mail enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.3.4 |
wtWebioAn1GraphPtMailAuthenticationSelection of the authentication modi:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : POP3 before SMTP
Bit 1 : ESMTP, authentication
Bit 0 : SMTP, no authenticationrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.3.5 |
wtWebioAn1GraphPtMailAuthUserName of the user to be authenticated.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.3.6 |
wtWebioAn1GraphPtMailAuthPasswordAuthentication password.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.3.7 |
wtWebioAn1GraphPtMailPop3ServerName or Ip-address of the POP3 Servers.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.3.8 |
wtWebioAn1GraphPtSNMP OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.3.4 |
wtWebioAn1GraphPtSnmpCommunityStringReadCommunity string read onlyrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.4.1 |
wtWebioAn1GraphPtSnmpCommunityStringReadWriteCommunity string read / writerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.4.2 |
wtWebioAn1GraphPtSystemTrapManagerIPName or IP address of the TCP server which accepts the system trap.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.4.3 |
wtWebioAn1GraphPtSystemTrapEnableBinary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.4.4 |
wtWebioAn1GraphPtSnmpEnableSet bit 0 to enable SNMP.
If disabled, the device did not respond to any SNMP requests.
Bit 1 decided wether the community string of read operations
is compared with the system password or not:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : SNMP enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.4.5 |
wtWebioAn1GraphPtSnmpCommunityStringTrapCommunity string send within traps.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.4.6 |
wtWebioAn1GraphPtUDP OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.3.5 |
wtWebioAn1GraphPtUdpPortUdp port to which the Udp queries ( short form GET requests) can be sent. This
port number must be unique within the device.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.3.5.1 |
wtWebioAn1GraphPtUdpEnableSet this bit to enable UDP support:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : UDP enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.5.2 |
wtWebioAn1GraphPtSyslog OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.3.6 |
wtWebioAn1GraphPtSyslogServerIPName or IP address of the Syslog server, which accepts the Syslog messgaes.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.6.1 |
wtWebioAn1GraphPtSyslogServerPortPortnumber of the Syslog servers, default 514.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.3.6.2 |
wtWebioAn1GraphPtSyslogSystemMessagesEnableBinary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2: Diag Messages
Bit 3-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.6.3 |
wtWebioAn1GraphPtSyslogEnableSet bit 0 to enable Syslog:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Syslog enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.6.4 |
wtWebioAn1GraphPtFTP OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.3.7 |
wtWebioAn1GraphPtFTPServerIPName or IP address of the FTP server, which accepts the FTP messages.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.7.1 |
wtWebioAn1GraphPtFTPServerControlPortPortnumber of the control port of the FTP server, default 21.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.3.7.2 |
wtWebioAn1GraphPtFTPUserNameFTP Loggin: user name.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.7.3 |
wtWebioAn1GraphPtFTPPasswordFTP Loggin: user password.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.7.4 |
wtWebioAn1GraphPtFTPAccountFTP Loggin: name of account.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.7.5 |
wtWebioAn1GraphPtFTPOptionBit 0 switches the FTP Server in Passiv-Mode,
the Client controls the data connection on its own:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : PASV enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.7.6 |
wtWebioAn1GraphPtFTPEnableSet Bit 0 to enable FTP:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : FTP enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.7.7 |
wtWebioAn1GraphPtLanguage OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.3.9 |
wtWebioAn1GraphPtLanguageSelectLanguage selection:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 2-7: unused
Bit 1 : english
Bit 0 : germanrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.3.9.1 |
wtWebioAn1GraphPtDatalogger OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.4 |
wtWebioAn1GraphPtLoggerTimebaseTime base of the data loggerrw Enumeration .1.3.6.1.4.1.5040.1.2.17.3.1.4.1 |
wtWebioAn1GraphPtLoggerSensorSelBinary coded sensor selection:
only selected sensors will be logged.
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.4.2 |
wtWebioAn1GraphPtDisplaySensorSelBinary coded sensor selection:
only selected sensors will be shown in the graphical presentation:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.4.3 |
wtWebioAn1GraphPtSensorColorTableList of sensor colors for the praphical presentation. SEQUENCE OF WtWebioAn1GraphPtSensorColorEntry .1.3.6.1.4.1.5040.1.2.17.3.1.4.4 |
wtWebioAn1GraphPtSensorColorEntryIndex numbers of the sensors. WtWebioAn1GraphPtSensorColorEntry .1.3.6.1.4.1.5040.1.2.17.3.1.4.4.1 |
wtWebioAn1GraphPtSensorColorColor of the sensors at the praphical presention.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.4.4.1.1 |
wtWebioAn1GraphPtAutoScaleEnableIf bit 0 is set, vertical auto scale is enabled:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Auto Scale enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.4.5 |
wtWebioAn1GraphPtVerticalUpperLimitThis value defines the maximum temperature shown in the graphical presentation,
if no auto scaling is selected.
Temperature in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.4.6 |
wtWebioAn1GraphPtVerticalLowerLimitThis value defines the minimum temperature shown in the graphical presentation,
if no auto scaling is selected.
Temperature in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.4.7 |
wtWebioAn1GraphPtHorizontalZoomDefines the default zoom stage, if no auto scaling is selected.rw Enumeration .1.3.6.1.4.1.5040.1.2.17.3.1.4.8 |
wtWebioAn1GraphPtAlarm OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.5 |
wtWebioAn1GraphPtAlarmCountNumber of independent alarms.ro INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.5.1 |
wtWebioAn1GraphPtAlarmIfTableList of alarm indices. SEQUENCE OF WtWebioAn1GraphPtAlarmIfEntry .1.3.6.1.4.1.5040.1.2.17.3.1.5.2 |
wtWebioAn1GraphPtAlarmIfEntryNumbers of the alarms. WtWebioAn1GraphPtAlarmIfEntry .1.3.6.1.4.1.5040.1.2.17.3.1.5.2.1 |
wtWebioAn1GraphPtAlarmNoAlarm number.ro INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.5.2.1.1 |
wtWebioAn1GraphPtAlarmTableList of settings depending on the alarm number. SEQUENCE OF WtWebioAn1GraphPtAlarmEntry .1.3.6.1.4.1.5040.1.2.17.3.1.5.3 |
wtWebioAn1GraphPtAlarmEntryAlarm parameters of the individual alarms. WtWebioAn1GraphPtAlarmEntry .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1 |
wtWebioAn1GraphPtAlarmTriggerBinary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0 : Timer
Bit 1 : ColdStart
Bit 2 : WarmStart
Bit 3 : Sensor lost
Bit 4-7: unused
Octet 4:
Bit 0 : Sensor 1
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.1 |
wtWebioAn1GraphPtAlarmMinMinimum temperature in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.2 |
wtWebioAn1GraphPtAlarmMaxMaximum temperature in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.3 |
wtWebioAn1GraphPtAlarmHysteresisTemperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.4 |
wtWebioAn1GraphPtAlarmDelayAlarm will be delayed by setting this time while stable alarm
condition occur (time in minutes).rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.5 |
wtWebioAn1GraphPtAlarmIntervalSend interval for alarm messages.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.6 |
wtWebioAn1GraphPtAlarmEnableBinary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Mail Enable
Bit 1 : SNMP Trap enable
Bit 2 : TCP Client enable
Bit 3 : Syslog Messages enable
Bit 4 : FTP enable
Bit 5-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.7 |
wtWebioAn1GraphPtAlarmEMailAddrE-Mail address for sending the alarm mail to.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.8 |
wtWebioAn1GraphPtAlarmMailSubjectSubject line for alarm mail.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.9 |
wtWebioAn1GraphPtAlarmMailTextAlarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.10 |
wtWebioAn1GraphPtAlarmManagerIPName or IP address of the SNMP Manager which accepts the trap.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.11 |
wtWebioAn1GraphPtAlarmTrapTextThis text is sent in the trap body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.12 |
wtWebioAn1GraphPtAlarmMailOptionsBinary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.13 |
wtWebioAn1GraphPtAlarmTcpIpAddrName or IP address of the TCP server which accepts the trap.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.14 |
wtWebioAn1GraphPtAlarmTcpPortPort number of the TCP server which accepts the trap.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.15 |
wtWebioAn1GraphPtAlarmTcpTextThis text is sent in the TCP trap body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.16 |
wtWebioAn1GraphPtAlarmClearMailSubjectSubject line for alarm clear mail.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.17 |
wtWebioAn1GraphPtAlarmClearMailTextAlarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.18 |
wtWebioAn1GraphPtAlarmClearTrapTextThis text is sent in the trap body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.19 |
wtWebioAn1GraphPtAlarmClearTcpTextThis text is sent in the TCP trap body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.20 |
wtWebioAn1GraphPtAlarmSyslogIpAddrIP address of the syslog server to which the Webio device should send syslog messages.rw IpAddress .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.21 |
wtWebioAn1GraphPtAlarmSyslogPortPort number of the syslog server to which the Webio device should send syslog messages.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.22 |
wtWebioAn1GraphPtAlarmSyslogTextEvery message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.23 |
wtWebioAn1GraphPtAlarmSyslogClearTextEvery message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.24 |
wtWebioAn1GraphPtAlarmFtpDataPortLocal data port: 1..65535 or AUTO: the next free port will be assigned.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.25 |
wtWebioAn1GraphPtAlarmFtpFileNameName of the file including path informations.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.26 |
wtWebioAn1GraphPtAlarmFtpTextMessage text to store on the FTP server.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.27 |
wtWebioAn1GraphPtAlarmFtpClearTextAlarm clear message to store on the FTP server.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.28 |
wtWebioAn1GraphPtAlarmFtpOptionBinary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STORE
Bit 1 : APPEND
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.29 |
wtWebioAn1GraphPtAlarmTimerCronThis entry defines a time window for alarm 1-8 and a activation time for the report.
A time window is definied by start and stop time stamp, seperated by a space or tab.
The activation time of the report is defined by a single start time stamp.
Each time stamp contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger an action, weekday and day of month
are interpreted separatley.
1: Minutes Range 0-59
2. Hours Range 0-23, 0 is midnight
3: Day of month Range 1-31
4: Month Range 1-12
5: Weekday Range 0-6, 0 is sunday
Syntax for every field:
- an asterix (*) enables every possible setting of a field
- single numbers seperated by commas (i.e.: 2,14,22)
- a partition within the allowed range (i.e.: 1-5)
- step size within a partition of the allowed range (i.e.: 0-59/2 every second minute).rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.30 |
wtWebioAn1GraphPtAlarmDeltaTempMaximum rate of change degrees/min with maximum 2 decimal places.
Compared with the average of a period of 5 minutes.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.31 |
wtWebioAn1GraphPtAlarmNameAlert namerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.39 |
wtWebioAn1GraphPtAlarmActiveAlert active
1 = ON
0 = OFFrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.5.3.1.40 |
wtWebioAn1GraphPtGraphics OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.6 |
wtWebioAn1GraphPtGraphicsBase OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.6.1 |
wtWebioAn1GraphPtGraphicsBaseEnableDefines the viewing options of the graphic:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Auto scroll enable
Bit 1 : Show table
Bit 2 : Show graph
Bit 3 : Show control buttons
Bit 4 : Show config menu
Bit 5 : Show Logo
Bit 6-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.1.1 |
wtWebioAn1GraphPtGraphicsBaseWidthDefines the width of the graphic in pixels.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.6.1.2 |
wtWebioAn1GraphPtGraphicsBaseHeightDefines the height of the graphic in pixels.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.6.1.3 |
wtWebioAn1GraphPtGraphicsBaseFrameColorFrame color definition in RGB.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.1.4 |
wtWebioAn1GraphPtGraphicsBaseBackgroundColorBackground color definition in RGB.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.1.5 |
wtWebioAn1GraphPtGraphicsBasePollingrateDefines the pollingrate in seconds,
which defines the refreshing intervall of the graphic.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.6.1.6 |
wtWebioAn1GraphPtGraphicsSelect OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.6.2 |
wtWebioAn1GraphPtGraphicsSelectDisplaySensorSelBinary coded sensor selection:
only selected sensors will be shown in the graphical presentation:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Sensor 1
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.2.1 |
wtWebioAn1GraphPtGraphicsSelectDisplayShowExtremBinary coded sensor selection:
only selected sensors will be shown with minima and maxima:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Sensor 1
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.2.2 |
wtWebioAn1GraphPt2SensorColorTableList of sensor colors for the praphical presentation. SEQUENCE OF WtWebioAn1GraphPt2SensorColorEntry .1.3.6.1.4.1.5040.1.2.17.3.1.6.2.3 |
wtWebioAn1GraphPt2SensorColorEntryNumbers of the sensors. WtWebioAn1GraphPt2SensorColorEntry .1.3.6.1.4.1.5040.1.2.17.3.1.6.2.3.1 |
wtWebioAn1GraphPt2GraphicsSensorColorColor of the sensors at the praphical presention.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.2.3.1.1 |
wtWebioAn1GraphPt2GraphicsSelectScaleAssignes one of 4 scales to a sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Use Scale 1
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.2.3.1.2 |
wtWebioAn1GraphPtGraphicsScale OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.1.6.3 |
wtWebioAn1GraphPtGraphicsScaleAutoScaleEnableSelect the Auto Scale Mode:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Scale 1 Auto scale enable
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.1 |
wtWebioAn1GraphPtGraphicsScaleAutoFitEnableSelect the Auto Fit Mode::
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Scale 1 Auto fit enable
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.2 |
wtWebioAn1GraphPtGraphicsScale1MinScale 1: Minimum.ro INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.3 |
wtWebioAn1GraphPtGraphicsScale2MinScale 2: Minimum.ro INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.4 |
wtWebioAn1GraphPtGraphicsScale3MinScale 3: Minimum.ro INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.5 |
wtWebioAn1GraphPtGraphicsScale4MinScale 4: Minimum.ro INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.6 |
wtWebioAn1GraphPtGraphicsScale1MaxScale 1: Maximum.ro INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.7 |
wtWebioAn1GraphPtGraphicsScale2MaxScale 2: Maximum.ro INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.8 |
wtWebioAn1GraphPtGraphicsScale3MaxScale 3: Maximum.ro INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.9 |
wtWebioAn1GraphPtGraphicsScale4MaxScale 4: Maximum.ro INTEGER .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.10 |
wtWebioAn1GraphPtGraphicsScale1UnitScale 1: Unit.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.11 |
wtWebioAn1GraphPtGraphicsScale2UnitScale 2: Unit.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.12 |
wtWebioAn1GraphPtGraphicsScale3UnitScale 3: Unit.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.13 |
wtWebioAn1GraphPtGraphicsScale4UnitScale 4: Unit.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.1.6.3.14 |
wtWebioAn1GraphPtPorts OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.2 |
wtWebioAn1GraphPtPortTableList of settings depending on the sensor number. SEQUENCE OF WtWebioAn1GraphPtPortEntry .1.3.6.1.4.1.5040.1.2.17.3.2.1 |
wtWebioAn1GraphPtPortEntrySensor parameters for the individual sensors. WtWebioAn1GraphPtPortEntry .1.3.6.1.4.1.5040.1.2.17.3.2.1.1 |
wtWebioAn1GraphPtPortNameName of the sensor.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.1 |
wtWebioAn1GraphPtPortTextDescription of the sensor.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.2 |
wtWebioAn1GraphPtPortOffset1Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.3 |
wtWebioAn1GraphPtPortTemperature1Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.4 |
wtWebioAn1GraphPtPortOffset2Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.5 |
wtWebioAn1GraphPtPortTemperature2Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.6 |
wtWebioAn1GraphPtPortCommentOffset calibration: informations of date, name of operator, reference devices.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.7 |
wtWebioAn1GraphPtPortSensorSelectBinary coded options of the sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : PT100 (default)
Bit 1 : PT1000
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.2.1.1.8 |
wtWebioAn1GraphPtManufact OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.3.3 |
wtWebioAn1GraphPtMfNameManufacturer company namerw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.3.1 |
wtWebioAn1GraphPtMfAddrManufacturer address.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.3.2 |
wtWebioAn1GraphPtMfHotlineManufacturer hotline.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.3.3 |
wtWebioAn1GraphPtMfInternetManufacturer Internet address.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.3.4 |
wtWebioAn1GraphPtMfDeviceTypManufacturer device name (model number).rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.3.5 |
wtWebioAn1GraphPtMfOrderNoManufacturer part number.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.17.3.3.6 |
wtWebioAn1GraphPtDiag OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.17.4 |
wtWebioAn1GraphPtDiagErrorCountNumber of entries in the error memory.ro INTEGER .1.3.6.1.4.1.5040.1.2.17.4.1 |
wtWebioAn1GraphPtDiagBinaryErrorError causes coded bit-by-bit.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.17.4.2 |
wtWebioAn1GraphPtDiagErrorIndexThe value of this variable is used as an index to read
an error massege from wtWebioAn1GraphPtDiagErrorMessage.
Errors are numbered from 1 to wtWebioAn1GraphPtDiagErrorCount.
Writing a valid value into this variable, making the appropriate
message readable from wtWebioAn1GraphPtDiagErrorMessage.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.4.3 |
wtWebioAn1GraphPtDiagErrorMessageUsing wtWebioAn1GraphPtDiagErrorIndex as an index, the appropriate message is available.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.17.4.4 |
wtWebioAn1GraphPtDiagErrorClearWriting 1 into this variable clears all diagnosis messages.rw INTEGER .1.3.6.1.4.1.5040.1.2.17.4.5 |
wtWebioAn1GraphPtSw OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23 |
wtWebioAn1GraphPtSwAlert1This SNMP trap is generated when Alarm 1 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.31 |
wtWebioAn1GraphPtSwAlert2This SNMP trap is generated when Alarm 2 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.32 |
wtWebioAn1GraphPtSwAlert3This SNMP trap is generated when Alarm 3 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.33 |
wtWebioAn1GraphPtSwAlert4This SNMP trap is generated when Alarm 4 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.34 |
wtWebioAn1GraphPtSwAlert5This SNMP trap is generated when Alarm 5 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.35 |
wtWebioAn1GraphPtSwAlert6This SNMP trap is generated when Alarm 6 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.36 |
wtWebioAn1GraphPtSwAlert7This SNMP trap is generated when Alarm 7 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.37 |
wtWebioAn1GraphPtSwAlert8This SNMP trap is generated when Alarm 8 was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.38 |
wtWebioAn1GraphPtSwAlert9This SNMP trap is generated when Alarm 1 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.91 |
wtWebioAn1GraphPtSwAlert10This SNMP trap is generated when Alarm 2 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.92 |
wtWebioAn1GraphPtSwAlert11This SNMP trap is generated when Alarm 3 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.93 |
wtWebioAn1GraphPtSwAlert12This SNMP trap is generated when Alarm 4 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.94 |
wtWebioAn1GraphPtSwAlert13This SNMP trap is generated when Alarm 5 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.95 |
wtWebioAn1GraphPtSwAlert14This SNMP trap is generated when Alarm 6 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.96 |
wtWebioAn1GraphPtSwAlert15This SNMP trap is generated when Alarm 7 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.97 |
wtWebioAn1GraphPtSwAlert16This SNMP trap is generated when Alarm 8 was cleared,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.98 |
wtWebioAn1GraphPtSwAlertDiagThis SNMP trap is generated when a diagnosis/error message was triggered,
SNMP trap enable is set and
SNMP is enabled. TRAP-TYPE .1.3.6.1.4.1.5040.1.2.23.0.110 |
wtWebioAn1GraphPtSwTemp OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.1 |
wtWebioAn1GraphPtSwSensorsNumber of temperature sensorsro INTEGER (1) .1.3.6.1.4.1.5040.1.2.23.1.1 |
wtWebioAn1GraphPtSwSensorTableList of sensors. SEQUENCE OF WtWebioAn1GraphPtSwSensorEntry .1.3.6.1.4.1.5040.1.2.23.1.2 |
wtWebioAn1GraphPtSwSensorEntryTemperature sensor numbers. WtWebioAn1GraphPtSwSensorEntry .1.3.6.1.4.1.5040.1.2.23.1.2.1 |
wtWebioAn1GraphPtSwSensorNoTemperature sensor number.ro INTEGER (1) .1.3.6.1.4.1.5040.1.2.23.1.2.1.1 |
wtWebioAn1GraphPtSwTempValueTableList of temperature values corresponding to the channel numbers. SEQUENCE OF WtWebioAn1GraphPtSwTempValueEntry .1.3.6.1.4.1.5040.1.2.23.1.3 |
wtWebioAn1GraphPtSwTempValueEntryTemperatures of the sensors. WtWebioAn1GraphPtSwTempValueEntry .1.3.6.1.4.1.5040.1.2.23.1.3.1 |
wtWebioAn1GraphPtSwTempValueTemperature value of the sensor, ASCII, 5 characters in length.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.23.1.3.1.1 |
wtWebioAn1GraphPtSwBinaryTempValueTableList of binary temperature values corresponding to the channel numbers. SEQUENCE OF WtWebioAn1GraphPtSwBinaryTempValueEntry .1.3.6.1.4.1.5040.1.2.23.1.4 |
wtWebioAn1GraphPtSwBinaryTempValueEntryBinary temperature values of the sensors. WtWebioAn1GraphPtSwBinaryTempValueEntry .1.3.6.1.4.1.5040.1.2.23.1.4.1 |
wtWebioAn1GraphPtSwBinaryTempValueBinary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an
invalid measured value.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.1.4.1.1 |
wtWebioAn1GraphPtSwOutputsNumber of outputs.ro INTEGER (1) .1.3.6.1.4.1.5040.1.2.23.1.5 |
wtWebioAn1GraphPtSwOutputTableList of outputs. SEQUENCE OF WtWebioAn1GraphPtSwOutputEntry .1.3.6.1.4.1.5040.1.2.23.1.6 |
wtWebioAn1GraphPtSwOutputEntryOutput numbers. WtWebioAn1GraphPtSwSensorEntry .1.3.6.1.4.1.5040.1.2.23.1.6.1 |
wtWebioAn1GraphPtSwOutputNoOutput number.ro INTEGER (1) .1.3.6.1.4.1.5040.1.2.23.1.6.1.1 |
wtWebioAn1GraphPtSwBinaryOutputValueTableList of binary ouput values corresponding to the channel numbers. SEQUENCE OF WtWebioAn1GraphPtSwBinaryOutputValueEntry .1.3.6.1.4.1.5040.1.2.23.1.7 |
wtWebioAn1GraphPtSwBinaryOutputValueEntryBinary states of the outputs. WtWebioAn1GraphPtSwBinaryOutputValueEntry .1.3.6.1.4.1.5040.1.2.23.1.7.1 |
wtWebioAn1GraphPtSwBinaryOutputValueBinary state of the output.ro Enumeration .1.3.6.1.4.1.5040.1.2.23.1.7.1.1 |
wtWebioAn1GraphPtSwTempValuePktTableList of temperature values corresponding to the channel numbers. SEQUENCE OF WtWebioAn1GraphPtSwTempValuePktEntry .1.3.6.1.4.1.5040.1.2.23.1.8 |
wtWebioAn1GraphPtSwTempValuePktEntryTemperatures of the sensors. WtWebioAn1GraphPtSwTempValuePktEntry .1.3.6.1.4.1.5040.1.2.23.1.8.1 |
wtWebioAn1GraphPtSwTempValuePktTemperature value of the sensor, ASCII, 5 characters in length, decimal point.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.23.1.8.1.1 |
wtWebioAn1GraphPtSwSessCntrl OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.2 |
wtWebioAn1GraphPtSwSessCntrlPasswordEntering this password opens a session which is ended by writing a 1 to
wtWebioAn1GraphPtSwSessCntrlLogout. When read this variable provides a string of
length zero.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.2.1 |
wtWebioAn1GraphPtSwSessCntrlConfigModeWhen the device is in SNMP configuration mode, the value 1 is
returned, otherwise 0. If the read value is 0 even though the
password was written, the device is already in config mode and the
variables can only be read.ro Enumeration .1.3.6.1.4.1.5040.1.2.23.2.2 |
wtWebioAn1GraphPtSwSessCntrlLogoutIf the device is in configuration mode and the session was opened by
this SNMP Manager, writing a 1 to this variable will end the session
and all parameters are stored.
Writing a 2 discards all entries again.
When read this variable provides the value 0.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.2.3 |
wtWebioAn1GraphPtSwSessCntrlAdminPasswordThis password protects access to the variables with administrator rights.
It can only be changed by the administrator. If no password was assigned,
the valid password is public.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.2.4 |
wtWebioAn1GraphPtSwSessCntrlConfigPasswordThis password protects access to the variables with configurator rights. It can
be changed by the administrator and by the configurator. If no password was assigned,
the valid password is public. When read this variable provides a null-pointer.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.2.5 |
wtWebioAn1GraphPtSwConfig OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3 |
wtWebioAn1GraphPtSwDevice OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1 |
wtWebioAn1GraphPtSwText OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.1 |
wtWebioAn1GraphPtSwDeviceNameName of the Webio, which is user definable.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.1.1 |
wtWebioAn1GraphPtSwDeviceTextDescription of the Webio, which is user definable.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.1.2 |
wtWebioAn1GraphPtSwDeviceLocationDescription of the location of the Webio, which is user definable.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.1.3 |
wtWebioAn1GraphPtSwDeviceContactContact address of the system operator of the Webio, which is user definable.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.1.4 |
wtWebioAn1GraphPtSwTimeDate OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.2 |
wtWebioAn1GraphPtSwTimeZone OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.2.1 |
wtWebioAn1GraphPtSwTzOffsetHrsOffset hours for the time zone (winter time) with respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.1 |
wtWebioAn1GraphPtSwTzOffsetMinOffset minutes for the time zone (winter time) with respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.2 |
wtWebioAn1GraphPtSwTzEnableBinary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Timezonerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.3 |
wtWebioAn1GraphPtSwStTzOffsetHrsOffset hours of the time zone (summer time) with respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.4 |
wtWebioAn1GraphPtSwStTzOffsetMinOffset minutes of the time zone (summer time) with respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.5 |
wtWebioAn1GraphPtSwStTzEnableBinary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Summertimerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.6 |
wtWebioAn1GraphPtSwStTzStartMonthMonth in which the change is made from winter time to summer time.rw Enumeration .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.7 |
wtWebioAn1GraphPtSwStTzStartModeMode of the day of the week for which the change is made from winter time to summer time.rw Enumeration .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.8 |
wtWebioAn1GraphPtSwStTzStartWdayDay of the week on which the change is made from winter time to summer timerw Enumeration .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.9 |
wtWebioAn1GraphPtSwStTzStartHrsHour in which the time zone is changed from winter to summer time with
respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.10 |
wtWebioAn1GraphPtSwStTzStartMinMinute in which the time zone is changed from winter to summer time with
respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.11 |
wtWebioAn1GraphPtSwStTzStopMonthMonth in which the change is made from summer time to winter time.rw Enumeration .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.12 |
wtWebioAn1GraphPtSwStTzStopModeMode of the week day on which the change is made from summer time to winter time.rw Enumeration .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.13 |
wtWebioAn1GraphPtSwStTzStopWdayDay of the week on which the change is made from summer time to winter time.rw Enumeration .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.14 |
wtWebioAn1GraphPtSwStTzStopHrsHour at which the time zone is changed from summer to winter time with
respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.15 |
wtWebioAn1GraphPtSwStTzStopMinMinute at which the time zone is changed from summer to winter time with
respect to UTC.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.1.16 |
wtWebioAn1GraphPtSwTimeServer OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.2.2 |
wtWebioAn1GraphPtSwTimeServer1IP address or name of the 1st time server in ASCIIrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.2.2.1 |
wtWebioAn1GraphPtSwTimeServer2IP address or name of the 2nd time server in ASCIIrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.2.2.2 |
wtWebioAn1GraphPtSwTsEnableBinary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Time Serverrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.2.2.3 |
wtWebioAn1GraphPtSwTsSyncTimeDaily synchronisation time with the time server (hour: 0-23).rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.2.4 |
wtWebioAn1GraphPtSwDeviceClock OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.2.3 |
wtWebioAn1GraphPtSwClockHrsClock hours taking into account the time zone settings.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.3.1 |
wtWebioAn1GraphPtSwClockMinClock minutes taking into account the time zone settings.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.3.2 |
wtWebioAn1GraphPtSwClockDayDate: Day of the month, taking into account the time zone settings.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.3.3 |
wtWebioAn1GraphPtSwClockMonthDate: Month, taking into account the time zone settings.rw Enumeration .1.3.6.1.4.1.5040.1.2.23.3.1.2.3.4 |
wtWebioAn1GraphPtSwClockYearDate: Year, taking into account the time zone settings.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.2.3.5 |
wtWebioAn1GraphPtSwBasic OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.3 |
wtWebioAn1GraphPtSwNetwork OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.3.1 |
wtWebioAn1GraphPtSwIpAddressIP address of the Webiorw IpAddress .1.3.6.1.4.1.5040.1.2.23.3.1.3.1.1 |
wtWebioAn1GraphPtSwSubnetMaskSubnet mask of the Webiorw IpAddress .1.3.6.1.4.1.5040.1.2.23.3.1.3.1.2 |
wtWebioAn1GraphPtSwGatewayGateway of the Webiorw IpAddress .1.3.6.1.4.1.5040.1.2.23.3.1.3.1.3 |
wtWebioAn1GraphPtSwDnsServer1IP address of the 1st DNS server in ASCIIrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.1.4 |
wtWebioAn1GraphPtSwDnsServer2IP address of the 2nd DNS server in ASCIIrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.1.5 |
wtWebioAn1GraphPtSwAddConfigAdditional configuration (1=ON):
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: DHCP disable
Bit 0: BOOTP disablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.1.6 |
wtWebioAn1GraphPtSwHTTP OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.3.2 |
wtWebioAn1GraphPtSwStartupBinary coded start page:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: Index.htm
Bit 2: Home.htm
Bit 3: User.htm
Only one page may be selected at a time.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.2.1 |
wtWebioAn1GraphPtSwGetHeaderEnableIf these bits are set, every answer of a short form GET question will be lead
by the IP-address and name of the device and/or a HTTP header:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-6: unused
Bit 1 : GET HTTP enable
Bit 0 : GET Header enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.2.2 |
wtWebioAn1GraphPtSwHttpPortDefinition of the standard HTML port (Default: 80).rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.3.2.3 |
wtWebioAn1GraphPtSwMail OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.3.3 |
wtWebioAn1GraphPtSwMailAdNameDevice name for mail administration.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.3.1 |
wtWebioAn1GraphPtSwMailReplyReply address for the mail server.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.3.2 |
wtWebioAn1GraphPtSwMailServerName or IP address of the mail server.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.3.3 |
wtWebioAn1MailEnableSet this bit to enable the sending of mails:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Mail enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.3.4 |
wtWebioAn1GraphPtSwMailAuthenticationSelection of the authentication modi:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : POP3 before SMTP
Bit 1 : ESMTP, authentication
Bit 0 : SMTP, no authenticationrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.3.5 |
wtWebioAn1GraphPtSwMailAuthUserName of the user to be authenticated.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.3.6 |
wtWebioAn1GraphPtSwMailAuthPasswordAuthentication password.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.3.7 |
wtWebioAn1GraphPtSwMailPop3ServerName or Ip-address of the POP3 Servers.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.3.8 |
wtWebioAn1GraphPtSwSNMP OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.3.4 |
wtWebioAn1GraphPtSwSnmpCommunityStringReadCommunity string read onlyrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.4.1 |
wtWebioAn1GraphPtSwSnmpCommunityStringReadWriteCommunity string read / writerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.4.2 |
wtWebioAn1GraphPtSwSystemTrapManagerIPName or IP address of the TCP server which accepts the system trap.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.4.3 |
wtWebioAn1GraphPtSwSystemTrapEnableBinary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.4.4 |
wtWebioAn1GraphPtSwSnmpEnableSet bit 0 to enable SNMP.
If disabled, the device did not respond to any SNMP requests.
Bit 1 decided wether the community string of read operations
is compared with the system password or not:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : SNMP enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.4.5 |
wtWebioAn1GraphPtSwSnmpCommunityStringTrapCommunity string send within traps.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.4.6 |
wtWebioAn1GraphPtSwUDP OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.3.5 |
wtWebioAn1GraphPtSwUdpPortUdp port to which the Udp queries ( short form GET requests) can be sent. This
port number must be unique within the device.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.3.5.1 |
wtWebioAn1GraphPtSwUdpEnableSet this bit to enable UDP support:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : UDP enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.5.2 |
wtWebioAn1GraphPtSwSyslog OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.3.6 |
wtWebioAn1GraphPtSwSyslogServerIPName or IP address of the Syslog server, which accepts the Syslog messgaes.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.6.1 |
wtWebioAn1GraphPtSwSyslogServerPortPortnumber of the Syslog servers, default 514.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.3.6.2 |
wtWebioAn1GraphPtSwSyslogSystemMessagesEnableBinary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2: Diag Messages
Bit 3-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.6.3 |
wtWebioAn1GraphPtSwSyslogEnableSet bit 0 to enable Syslog:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Syslog enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.6.4 |
wtWebioAn1GraphPtSwFTP OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.3.7 |
wtWebioAn1GraphPtSwFTPServerIPName or IP address of the FTP server, which accepts the FTP messages.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.7.1 |
wtWebioAn1GraphPtSwFTPServerControlPortPortnumber of the control port of the FTP server, default 21.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.3.7.2 |
wtWebioAn1GraphPtSwFTPUserNameFTP Loggin: user name.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.7.3 |
wtWebioAn1GraphPtSwFTPPasswordFTP Loggin: user password.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.7.4 |
wtWebioAn1GraphPtSwFTPAccountFTP Loggin: name of account.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.7.5 |
wtWebioAn1GraphPtSwFTPOptionBit 0 switches the FTP Server in Passiv-Mode,
the Client controls the data connection on its own:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : PASV enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.7.6 |
wtWebioAn1GraphPtSwFTPEnableSet Bit 0 to enable FTP:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : FTP enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.7.7 |
wtWebioAn1GraphPtSwLanguage OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.3.9 |
wtWebioAn1GraphPtSwLanguageSelectLanguage selection:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 2-7: unused
Bit 1 : English
Bit 0 : Germanrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.3.9.1 |
wtWebioAn1GraphPtSwDatalogger OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.4 |
wtWebioAn1GraphPtSwLoggerTimebaseTime base of the data loggerrw Enumeration .1.3.6.1.4.1.5040.1.2.23.3.1.4.1 |
wtWebioAn1GraphPtSwLoggerSensorSelBinary coded sensor / output selection:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Output 1
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.4.2 |
wtWebioAn1GraphPtSwDisplaySensorSelBinary coded sensor selection:
only selected sensors / outputs will be shown in the graphical presentation:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Output 1
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.4.3 |
wtWebioAn1GraphPtSwSensorColorTableList of sensor colors for the praphical presentation. SEQUENCE OF WtWebioAn1GraphPtSwSensorColorEntry .1.3.6.1.4.1.5040.1.2.23.3.1.4.4 |
wtWebioAn1GraphPtSwSensorColorEntryIndex numbers of the sensors. WtWebioAn1GraphPtSwSensorColorEntry .1.3.6.1.4.1.5040.1.2.23.3.1.4.4.1 |
wtWebioAn1GraphPtSwSensorColorColor of the sensors at the praphical presention.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.4.4.1.1 |
wtWebioAn1GraphPtSwAutoScaleEnableIf bit 0 is set, vertical auto scale is enabled:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Auto Scale enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.4.5 |
wtWebioAn1GraphPtSwVerticalUpperLimitThis value defines the maximum temperature shown in the graphical presentation,
if no auto scaling is selected.
Temperature in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.4.6 |
wtWebioAn1GraphPtSwVerticalLowerLimitThis value defines the minimum temperature shown in the graphical presentation,
if no auto scaling is selected.
Temperature in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.4.7 |
wtWebioAn1GraphPtSwHorizontalZoomDefines the default zoom stage, if no auto scaling is selected.rw Enumeration .1.3.6.1.4.1.5040.1.2.23.3.1.4.8 |
wtWebioAn1GraphPtSwAlarm OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.5 |
wtWebioAn1GraphPtSwAlarmCountNumber of independent alarms.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.5.1 |
wtWebioAn1GraphPtSwAlarmIfTableList of alarm indices. SEQUENCE OF WtWebioAn1GraphPtSwAlarmIfEntry .1.3.6.1.4.1.5040.1.2.23.3.1.5.2 |
wtWebioAn1GraphPtSwAlarmIfEntryNumbers of the alarms. WtWebioAn1GraphPtSwAlarmIfEntry .1.3.6.1.4.1.5040.1.2.23.3.1.5.2.1 |
wtWebioAn1GraphPtSwAlarmNoAlarm number.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.5.2.1.1 |
wtWebioAn1GraphPtSwAlarmTableList of settings depending on the alarm number. SEQUENCE OF WtWebioAn1GraphPtSwAlarmEntry .1.3.6.1.4.1.5040.1.2.23.3.1.5.3 |
wtWebioAn1GraphPtSwAlarmEntryAlarm parameters of the individual alarms. WtWebioAn1GraphPtSwAlarmEntry .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1 |
wtWebioAn1GraphPtSwAlarmTriggerBinary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0 : Timer
Bit 1 : ColdStart
Bit 2 : WarmStart
Bit 3 : Sensor lost
Bit 4-7: unused
Octet 4:
Bit 0 : Sensor 1
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.1 |
wtWebioAn1GraphPtSwAlarmMinMinimum temperature in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.2 |
wtWebioAn1GraphPtSwAlarmMaxMaximum temperature in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.3 |
wtWebioAn1GraphPtSwAlarmHysteresisTemperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.4 |
wtWebioAn1GraphPtSwAlarmDelayAlarm will be delayed by setting this time while stable alarm
condition occur (time in minutes).rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.5 |
wtWebioAn1GraphPtSwAlarmIntervalSend interval for alarm messages.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.6 |
wtWebioAn1GraphPtSwAlarmEnableBinary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Output switch enable
Bit 1 : Mail Enable
Bit 2 : SNMP Trap enable
Bit 3 : TCP Client enable
Bit 4 : Syslog Messages enable
Bit 5 : FTP enable
Bit 6-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.7 |
wtWebioAn1GraphPtSwAlarmEMailAddrE-Mail address for sending the alarm mail to.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.8 |
wtWebioAn1GraphPtSwAlarmMailSubjectSubject line for alarm mail.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.9 |
wtWebioAn1GraphPtSwAlarmMailTextAlarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.10 |
wtWebioAn1GraphPtSwAlarmManagerIPName or IP address of the SNMP Manager which accepts the trap.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.11 |
wtWebioAn1GraphPtSwAlarmTrapTextThis text is sent in the trap body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.12 |
wtWebioAn1GraphPtSwAlarmMailOptionsBinary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.13 |
wtWebioAn1GraphPtSwAlarmTcpIpAddrName or IP address of the TCP server which accepts the trap.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.14 |
wtWebioAn1GraphPtSwAlarmTcpPortPort number of the TCP server which accepts the trap.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.15 |
wtWebioAn1GraphPtSwAlarmTcpTextThis text is sent in the TCP trap body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.16 |
wtWebioAn1GraphPtSwAlarmClearMailSubjectSubject line for alarm clear mail.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.17 |
wtWebioAn1GraphPtSwAlarmClearMailTextAlarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.18 |
wtWebioAn1GraphPtSwAlarmClearTrapTextThis text is sent in the trap body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.19 |
wtWebioAn1GraphPtSwAlarmClearTcpTextThis text is sent in the TCP trap body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.20 |
wtWebioAn1GraphPtSwAlarmSyslogIpAddrIP address of the syslog server to which the Webio device should send syslog messages.rw IpAddress .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.21 |
wtWebioAn1GraphPtSwAlarmSyslogPortPort number of the syslog server to which the Webio device should send syslog messages.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.22 |
wtWebioAn1GraphPtSwAlarmSyslogTextEvery message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.23 |
wtWebioAn1GraphPtSwAlarmSyslogClearTextEvery message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.24 |
wtWebioAn1GraphPtSwAlarmFtpDataPortLocal data port: 1..65535 or AUTO: the next free port will be assigned.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.25 |
wtWebioAn1GraphPtSwAlarmFtpFileNameName of the file including path informations.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.26 |
wtWebioAn1GraphPtSwAlarmFtpTextMessage text to store on the FTP server.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.27 |
wtWebioAn1GraphPtSwAlarmFtpClearTextAlarm clear message to store on the FTP server.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.28 |
wtWebioAn1GraphPtSwAlarmFtpOptionsBinary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STORE
Bit 1 : APPEND
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.29 |
wtWebioAn1GraphPtSwAlarmTimerCronThis entry contains 5 text fields space or tab seperated for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separately.
1: Minutes Range 0-59
2. Hours Range 0-23, 0 is midnight
3: Day of month Range 1-31
4: Month Range 1-12
5: Weekday Range 0-6, 0 is sunday
Syntax for every field:
- an asterix (*) enables every possible setting of a field
- single numbers seperated by commas
- a partition within the allowed range (1-5)
- step size within an partition of the allowed range (0-59/2: every second minute).rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.30 |
wtWebioAn1GraphPtSwAlarmDeltaTempMaximum rate of change degrees/min with maximum 2 decimal places.
Compared with the average of a period of 5 minutes.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.31 |
wtWebioAn1GraphPtSwAlarmNameAlert namerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.39 |
wtWebioAn1GraphPtSwAlarmActiveAlert active
1 = ON
0 = OFFrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.5.3.1.40 |
wtWebioAn1GraphPtSwGraphics OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.6 |
wtWebioAn1GraphPtSwGraphicsBase OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.6.1 |
wtWebioAn1GraphPtSwGraphicsBaseEnableDefines the viewing options of the graphic:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Auto scroll enable
Bit 1 : Show table
Bit 2 : Show graph
Bit 3 : Show control buttons
Bit 4 : Show config menu
Bit 5 : Show alarm monitor
Bit 6-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.1.1 |
wtWebioAn1GraphPtSwGraphicsBaseWidthDefines the width of the graphic in pixels.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.6.1.2 |
wtWebioAn1GraphPtSwGraphicsBaseHeightDefines the height of the graphic in pixels.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.6.1.3 |
wtWebioAn1GraphPtSwGraphicsBaseFrameColorFrame color definition in RGB.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.1.4 |
wtWebioAn1GraphPtSwGraphicsBaseBackgroundColorBackground color definition in RGB.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.1.5 |
wtWebioAn1GraphPtSwGraphicsBasePollingrateDefines the pollingrate in seconds,
which defines the refreshing intervall of the graphic.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.6.1.6 |
wtWebioAn1GraphPtSwGraphicsSelect OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.6.2 |
wtWebioAn1GraphPtSwGraphicsSelectDisplaySensorSelBinary coded sensor selection:
only selected sensors will be shown in the graphical presentation:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Sensor 1
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.2.1 |
wtWebioAn1GraphPtSwGraphicsSelectDisplayShowExtremBinary coded sensor selection:
only selected sensors will be shown with minima and maxima:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Sensor 1
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.2.2 |
wtWebioAn1GraphPtSw2SensorColorTableList of sensor colors for the praphical presentation. SEQUENCE OF WtWebioAn1GraphPtSw2SensorColorEntry .1.3.6.1.4.1.5040.1.2.23.3.1.6.2.3 |
wtWebioAn1GraphPtSw2SensorColorEntryNumbers of the sensors. WtWebioAn1GraphPtSw2SensorColorEntry .1.3.6.1.4.1.5040.1.2.23.3.1.6.2.3.1 |
wtWebioAn1GraphPtSw2GraphicsSensorColorColor of the sensors at the praphical presention.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.2.3.1.1 |
wtWebioAn1GraphPtSw2GraphicsSelectScaleAssignes one of 4 scales to a sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Use Scale 1
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.2.3.1.2 |
wtWebioAn1GraphPtSwGraphicsScale OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.6.3 |
wtWebioAn1GraphPtSwGraphicsScaleAutoScaleEnableSelect the Auto Scale Mode:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Scale 1 Auto scale enable
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.1 |
wtWebioAn1GraphPtSwGraphicsScaleAutoFitEnableSelect the Auto Fit Mode::
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Scale 1 Auto fit enable
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.2 |
wtWebioAn1GraphPtSwGraphicsScale1MinScale 1: Minimum.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.3 |
wtWebioAn1GraphPtSwGraphicsScale2MinScale 2: Minimum.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.4 |
wtWebioAn1GraphPtSwGraphicsScale3MinScale 3: Minimum.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.5 |
wtWebioAn1GraphPtSwGraphicsScale4MinScale 4: Minimum.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.6 |
wtWebioAn1GraphPtSwGraphicsScale1MaxScale 1: Maximum.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.7 |
wtWebioAn1GraphPtSwGraphicsScale2MaxScale 2: Maximum.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.8 |
wtWebioAn1GraphPtSwGraphicsScale3MaxScale 3: Maximum.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.9 |
wtWebioAn1GraphPtSwGraphicsScale4MaxScale 4: Maximum.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.10 |
wtWebioAn1GraphPtSwGraphicsScale1UnitScale 1: Unit.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.11 |
wtWebioAn1GraphPtSwGraphicsScale2UnitScale 2: Unit.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.12 |
wtWebioAn1GraphPtSwGraphicsScale3UnitScale 3: Unit.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.13 |
wtWebioAn1GraphPtSwGraphicsScale4UnitScale 4: Unit.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.6.3.14 |
wtWebioAn1GraphPtSwReport OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.1.7 |
wtWebioAn1GraphPtSwReportCountNumber of independent Reports.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.7.1 |
wtWebioAn1GraphPtSwReportIfTableList of Report indices. SEQUENCE OF WtWebioAn1GraphPtSwReportIfEntry .1.3.6.1.4.1.5040.1.2.23.3.1.7.2 |
wtWebioAn1GraphPtSwReportIfEntryNumbers of the Reports. WtWebioAn1GraphPtSwReportIfEntry .1.3.6.1.4.1.5040.1.2.23.3.1.7.2.1 |
wtWebioAn1GraphPtSwReportNoReport number.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.7.2.1.1 |
wtWebioAn1GraphPtSwReportTableList of settings depending on the Report number. SEQUENCE OF WtWebioAn1GraphPtSwReportEntry .1.3.6.1.4.1.5040.1.2.23.3.1.7.3 |
wtWebioAn1GraphPtSwReportEntryReport parameters of the individual Reports. WtWebioAn1GraphPtSwReportEntry .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1 |
wtWebioAn1GraphPtSwReportEnableBinr kodierte Triggerbedingungen:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Report enable
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.1 |
wtWebioAn1GraphPtSwReportTimerCronThis entry defines a time window for alarm 1-8 and a activation time for the report.
A time window is definied by start and stop time stamp, seperated by a space or tab.
The activation time of the report is defined by a single start time stamp.
Each time stamp contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger an action, weekday and day of month
are interpreted separatley.
1: Minutes Range 0-59
2. Hours Range 0-23, 0 is midnight
3: Day of month Range 1-31
4: Month Range 1-12
5: Weekday Range 0-6, 0 is sunday
Syntax for every field:
- an asterix (*) enables every possible setting of a field
- single numbers seperated by commas (i.e.: 2,14,22)
- a partition within the allowed range (i.e.: 1-5)
- step size within a partition of the allowed range (i.e.: 0-59/2 every second minute).rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.2 |
wtWebioAn1GraphPtSwReportMethodeEnableBinary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable
Bit 3: Syslog enable
Bit 4: FTP Client enablerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.3 |
wtWebioAn1GraphPtSwReportEMailAddrE-Mail address for sending the alarm mail to.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.8 |
wtWebioAn1GraphPtSwReportMailSubjectSubject line for alarm mail.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.9 |
wtWebioAn1GraphPtSwReportMailTextReport mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.10 |
wtWebioAn1GraphPtSwReportManagerIPName or IP address of the SNMP Manager which accepts the trap.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.11 |
wtWebioAn1GraphPtSwReportTrapTextThis text is sent in the trap body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.12 |
wtWebioAn1GraphPtSwReportMailOptionsBinary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Logger.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.13 |
wtWebioAn1GraphPtSwReportTcpIpAddrName or IP address of the TCP server which accepts the trap.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.14 |
wtWebioAn1GraphPtSwReportTcpPortPort number of the TCP server which accepts the trap.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.15 |
wtWebioAn1GraphPtSwReportTcpTextThis text is sent in the TCP trap body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.16 |
wtWebioAn1GraphPtSwReportClearMailSubjectSubject line for alarm clear mail.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.17 |
wtWebioAn1GraphPtSwReportClearMailTextReport clear mail text: <Mn> provides the current temperature; n = 1..2.
<Z> provides the current time.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.18 |
wtWebioAn1GraphPtSwReportClearTrapTextThis text is sent in the trap body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.19 |
wtWebioAn1GraphPtSwReportClearTcpTextThis text is sent in the TCP trap body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.20 |
wtWebioAn1GraphPtSwReportSyslogIpAddrIP address of the syslog server to which the Webio device should send syslog messages.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.24 |
wtWebioAn1GraphPtSwReportSyslogPortPort number of the syslog server to which the Webio device should send syslog messages.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.25 |
wtWebioAn1GraphPtSwReportSyslogTextEvery message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.26 |
wtWebioAn1GraphPtSwReportSyslogClearTextEvery message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body of a alarm clear message.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.27 |
wtWebioAn1GraphPtSwReportFtpDataPortLocal data port: 1..65535 or AUTO: the next free port will be assigned.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.28 |
wtWebioAn1GraphPtSwReportFtpFileNameName of the file including path informations.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.29 |
wtWebioAn1GraphPtSwReportFtpTextMessage text to store on the FTP server.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.30 |
wtWebioAn1GraphPtSwReportFtpClearTextReport clear message to store on the FTP server.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.31 |
wtWebioAn1GraphPtSwReportFtpOptionBinary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STORE
Bit 1 : APPEND
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.1.7.3.1.32 |
wtWebioAn1GraphPtSwPorts OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.2 |
wtWebioAn1GraphPtSwPortTableList of settings depending on the sensor number. SEQUENCE OF WtWebioAn1GraphPtSwPortEntry .1.3.6.1.4.1.5040.1.2.23.3.2.1 |
wtWebioAn1GraphPtSwPortEntrySensor parameters for the individual sensors. WtWebioAn1GraphPtSwPortEntry .1.3.6.1.4.1.5040.1.2.23.3.2.1.1 |
wtWebioAn1GraphPtSwPortNameName of the sensor.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.1 |
wtWebioAn1GraphPtSwPortTextDescription of the sensor.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.2 |
wtWebioAn1GraphPtSwPortOffset1Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.3 |
wtWebioAn1GraphPtSwPortTemperature1Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.4 |
wtWebioAn1GraphPtSwPortOffset2Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.5 |
wtWebioAn1GraphPtSwPortTemperature2Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.6 |
wtWebioAn1GraphPtSwPortCommentOffset calibration: informations of date, name of operator, reference devices.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.7 |
wtWebioAn1GraphPtSwPortSensorSelectBinary coded options of the sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : PT100 (default)
Bit 1 : PT1000
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.8 |
wtWebioAn1GraphPtSwPortSensorUnitBinary coded options of the sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Celsius (default)
Bit 1 : Fahrenheit
Bit 2 : Kelvin
Bit 3-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.1.1.9 |
wtWebioAn1GraphPtSwPortOutputTableList of settings depending on the sensor number. SEQUENCE OF WtWebioAn1GraphPtSwPortOutputEntry .1.3.6.1.4.1.5040.1.2.23.3.2.3 |
wtWebioAn1GraphPtSwPortOutputEntryParameters for the individual outputs. WtWebioAn1GraphPtSwPortOutputEntry .1.3.6.1.4.1.5040.1.2.23.3.2.3.1 |
wtWebioAn1GraphPtSwPortOutputNameName of the output.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.3.1.1 |
wtWebioAn1GraphPtSwPortOutputTextDescription of the output.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.3.1.2 |
wtWebioAn1GraphPtSwPortOutputPolarityBinary coded options of the output:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Normally open (default)
Bit 1 : Normally closed
Bit 2-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.3.1.3 |
wtWebioAn1GraphPtSwPortOutputCommentAdditional informations of date, name of operator, reference devices.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.3.1.4 |
wtWebioAn1GraphPortOutputResetEnableBinary coded options of the output:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Manual Reset enable (default off)
Bit 1-7: unusedrw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.2.3.1.5 |
wtWebioAn1GraphPtSwManufact OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.3.3 |
wtWebioAn1GraphPtSwMfNameManufacturer company namerw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.3.1 |
wtWebioAn1GraphPtSwMfAddrManufacturer address.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.3.2 |
wtWebioAn1GraphPtSwMfHotlineManufacturer hotline.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.3.3 |
wtWebioAn1GraphPtSwMfInternetManufacturer Internet address.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.3.4 |
wtWebioAn1GraphPtSwMfDeviceTypManufacturer device name (model number).rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.3.5 |
wtWebioAn1GraphPtSwMfOrderNoManufacturer part number.rw OCTET STRING .1.3.6.1.4.1.5040.1.2.23.3.3.6 |
wtWebioAn1GraphPtSwDiag OBJECT IDENTIFIER .1.3.6.1.4.1.5040.1.2.23.4 |
wtWebioAn1GraphPtSwDiagErrorCountNumber of entries in the error memory.ro INTEGER .1.3.6.1.4.1.5040.1.2.23.4.1 |
wtWebioAn1GraphPtSwDiagBinaryErrorError causes coded bit-by-bit.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.23.4.2 |
wtWebioAn1GraphPtSwDiagErrorIndexThe value of this variable is used as an index to read
an error massege from wtWebioAn1GraphPtSwDiagErrorMessage.
Errors are numbered from 1 to wtWebioAn1GraphPtSwDiagErrorCount.
Writing a valid value into this variable, making the appropriate
message readable from wtWebioAn1GraphPtSwDiagErrorMessage.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.4.3 |
wtWebioAn1GraphPtSwDiagErrorMessageUsing wtWebioAn1GraphPtSwDiagErrorIndex as an index, the appropriate message is available.ro OCTET STRING .1.3.6.1.4.1.5040.1.2.23.4.4 |
wtWebioAn1GraphPtSwDiagErrorClearWriting 1 into this variable clears all diagnosis messages.rw INTEGER .1.3.6.1.4.1.5040.1.2.23.4.5 |