Home/Catalog/WebGraph-8xThermometer-US-MIB

WebGraph-8xThermometer-US-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for WebGraph-8xThermometer-US-MIB.

205
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

205 total
Object Name
wut
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040
IMPORTS
Unknown
.1.3.6.1.4.1.5040
wtComServer
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1
wtWebio
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2
wtWebioAn8Graph
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6
wtWebioAn8GraphTemp
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.1
wtWebioAn8GraphSensorsNumber of temperature sensorsro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.1.1
wtWebioAn8GraphSensorTableList of sensors.
SEQUENCE OF WtWebioAn8GraphSensorEntry
.1.3.6.1.4.1.5040.1.2.6.1.2
wtWebioAn8GraphSensorEntryTemperature sensor numbers.
WtWebioAn8GraphSensorEntry
.1.3.6.1.4.1.5040.1.2.6.1.2.1
wtWebioAn8GraphSensorNoTemperature sensor number.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.1.2.1.1
wtWebioAn8GraphTempValueTableList of temperature values corresponding to the channel numbers.
SEQUENCE OF WtWebioAn8GraphTempValueEntry
.1.3.6.1.4.1.5040.1.2.6.1.3
wtWebioAn8GraphTempValueEntryTemperatures of the sensors.
WtWebioAn8GraphTempValueEntry
.1.3.6.1.4.1.5040.1.2.6.1.3.1
wtWebioAn8GraphTempValueTemperature value of the sensor, ASCII, 5 characters in length.ro
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.1.3.1.1
wtWebioAn8GraphBinaryTempValueTableList of binary temperature values corresponding to the channel numbers.
SEQUENCE OF WtWebioAn8GraphBinaryTempValueEntry
.1.3.6.1.4.1.5040.1.2.6.1.4
wtWebioAn8GraphBinaryTempValueEntryBinary temperature values of the sensors.
WtWebioAn8GraphBinaryTempValueEntry
.1.3.6.1.4.1.5040.1.2.6.1.4.1
wtWebioAn8GraphBinaryTempValueBinary temperature value of the sensor in 1/10 degrees Celsius, signed number, 0x4FFF6 indicates an invalid measured value.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.1.4.1.1
wtWebioAn8GraphTempValuePktTableList of temperature values corresponding to the channel numbers.
SEQUENCE OF WtWebioAn8GraphTempValuePktEntry
.1.3.6.1.4.1.5040.1.2.6.1.8
wtWebioAn8GraphTempValuePktEntryTemperatures of the sensors.
WtWebioAn8GraphTempValuePktEntry
.1.3.6.1.4.1.5040.1.2.6.1.8.1
wtWebioAn8GraphTempValuePktTemperature value of the sensor, ASCII, 5 characters in length, decimal point.ro
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.1.8.1.1
wtWebioAn8GraphSessCntrl
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.2
wtWebioAn8GraphSessCntrlPasswordEntering this password opens a session which is ended by writing a 1 to wtWebioAn8GraphSessCntrlLogout. When read this variable provides a string of length zero.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.2.1
wtWebioAn8GraphSessCntrlConfigModeWhen the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read.ro
Enumeration
.1.3.6.1.4.1.5040.1.2.6.2.2
wtWebioAn8GraphSessCntrlLogoutIf the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.2.3
wtWebioAn8GraphSessCntrlAdminPasswordThis password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.2.4
wtWebioAn8GraphSessCntrlConfigPasswordThis password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.2.5
wtWebioAn8GraphConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3
wtWebioAn8GraphDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1
wtWebioAn8GraphText
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.1
wtWebioAn8GraphDeviceNameName of the Webio, which is user definable.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.1.1
wtWebioAn8GraphDeviceTextDescription of the Webio, which is user definable.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.1.2
wtWebioAn8GraphDeviceLocationDescription of the location of the Webio, which is user definable.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.1.3
wtWebioAn8GraphDeviceContactContact address of the system operator of the Webio, which is user definable.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.1.4
wtWebioAn8GraphTimeDate
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.2
wtWebioAn8GraphTimeZone
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1
wtWebioAn8GraphTzOffsetHrsOffset hours for the time zone (winter time) with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.1
wtWebioAn8GraphTzOffsetMinOffset minutes for the time zone (winter time) with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.2
wtWebioAn8GraphTzEnableBinary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezonerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.3
wtWebioAn8GraphStTzOffsetHrsOffset hours of the time zone (summer time) with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.4
wtWebioAn8GraphStTzOffsetMinOffset minutes of the time zone (summer time) with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.5
wtWebioAn8GraphStTzEnableBinary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertimerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.6
wtWebioAn8GraphStTzStartMonthMonth in which the change is made from winter time to summer time.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.7
wtWebioAn8GraphStTzStartModeMode of the day of the week for which the change is made from winter time to summer time.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.8
wtWebioAn8GraphStTzStartWdayDay of the week on which the change is made from winter time to summer timerw
Enumeration
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.9
wtWebioAn8GraphStTzStartHrsHour in which the time zone is changed from winter to summer time with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.10
wtWebioAn8GraphStTzStartMinMinute in which the time zone is changed from winter to summer time with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.11
wtWebioAn8GraphStTzStopMonthMonth in which the change is made from summer time to winter time.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.12
wtWebioAn8GraphStTzStopModeMode of the week day on which the change is made from summer time to winter time.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.13
wtWebioAn8GraphStTzStopWdayDay of the week on which the change is made from summer time to winter time.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.14
wtWebioAn8GraphStTzStopHrsHour at which the time zone is changed from summer to winter time with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.15
wtWebioAn8GraphStTzStopMinMinute at which the time zone is changed from summer to winter time with respect to UTC.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.1.16
wtWebioAn8GraphTimeServer
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.2
wtWebioAn8GraphTimeServer1IP address or name of the 1st time server in ASCIIrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.2.2.1
wtWebioAn8GraphTimeServer2IP address or name of the 2nd time server in ASCIIrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.2.2.2
wtWebioAn8GraphTsEnableBinary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Serverrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.2.2.3
wtWebioAn8GraphTsSyncTimeDaily synchronisation time with the time server (hour: 0-23).rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.2.4
wtWebioAn8GraphDeviceClock
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.3
wtWebioAn8GraphClockHrsClock hours taking into account the time zone settings.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.3.1
wtWebioAn8GraphClockMinClock minutes taking into account the time zone settings.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.3.2
wtWebioAn8GraphClockDayDate: Day of the month, taking into account the time zone settings.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.3.3
wtWebioAn8GraphClockMonthDate: Month, taking into account the time zone settings.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.6.3.1.2.3.4
wtWebioAn8GraphClockYearDate: Year, taking into account the time zone settings.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.2.3.5
wtWebioAn8GraphBasic
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.3
wtWebioAn8GraphNetwork
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.3.1
wtWebioAn8GraphIpAddressIP address of the Webiorw
IpAddress
.1.3.6.1.4.1.5040.1.2.6.3.1.3.1.1
wtWebioAn8GraphSubnetMaskSubnet mask of the Webiorw
IpAddress
.1.3.6.1.4.1.5040.1.2.6.3.1.3.1.2
wtWebioAn8GraphGatewayGateway of the Webiorw
IpAddress
.1.3.6.1.4.1.5040.1.2.6.3.1.3.1.3
wtWebioAn8GraphDnsServer1IP address of the 1st DNS server in ASCIIrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.1.4
wtWebioAn8GraphDnsServer2IP address of the 2nd DNS server in ASCIIrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.1.5
wtWebioAn8GraphAddConfigAdditional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: BOOTP disable Bit 1: DHCP disablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.1.6
wtWebioAn8GraphHTTP
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.3.2
wtWebioAn8GraphStartupBinary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.2.1
wtWebioAn8GraphGetHeaderEnableIf these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.2.2
wtWebioAn8GraphHttpPortDefinition of the standard HTML port (Default: 80).rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.3.2.3
wtWebioAn8GraphMail
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.3.3
wtWebioAn8GraphMailAdNameDevice name for mail administration.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.3.1
wtWebioAn8GraphMailReplyReply address for the mail server.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.3.2
wtWebioAn8GraphMailServerName or IP address of the mail server.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.3.3
wtWebioAn1MailEnableSet this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.3.4
wtWebioAn8GraphMailAuthenticationSelection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authenticationrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.3.5
wtWebioAn8GraphMailAuthUserName of the user to be authenticated.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.3.6
wtWebioAn8GraphMailAuthPasswordAuthentication password.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.3.7
wtWebioAn8GraphMailPop3ServerName or Ip-address of the POP3 Servers.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.3.8
wtWebioAn8GraphSNMP
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.3.4
wtWebioAn8GraphSnmpCommunityStringReadCommunity string read onlyrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.4.1
wtWebioAn8GraphSnmpCommunityStringReadWriteCommunity string read / writerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.4.2
wtWebioAn8GraphSystemTrapManagerIPName or IP address of the TCP server which accepts the system trap.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.4.3
wtWebioAn8GraphSystemTrapEnableBinary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.4.4
wtWebioAn8GraphSnmpEnableSet bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.4.5
wtWebioAn8GraphSnmpCommunityStringTrapCommunity string send within traps.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.4.6
wtWebioAn8GraphUDP
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.3.5
wtWebioAn8GraphUdpPortUdp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.3.5.1
wtWebioAn8GraphUdpEnableSet this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.5.2
wtWebioAn8GraphSyslog
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.3.6
wtWebioAn8GraphSyslogServerIPName or IP address of the Syslog server, which accepts the Syslog messgaes.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.6.1
wtWebioAn8GraphSyslogServerPortPortnumber of the Syslog servers, default 514.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.3.6.2
wtWebioAn8GraphSyslogSystemMessagesEnableBinary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.6.3
wtWebioAn8GraphSyslogEnableSet bit 0 to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.6.4
wtWebioAn8GraphFTP
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.3.7
wtWebioAn8GraphFTPServerIPName or IP address of the FTP server, which accepts the FTP messages.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.7.1
wtWebioAn8GraphFTPServerControlPortPortnumber of the control port of the FTP server, default 21.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.3.7.2
wtWebioAn8GraphFTPUserNameFTP Loggin: user name.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.7.3
wtWebioAn8GraphFTPPasswordFTP Loggin: user password.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.7.4
wtWebioAn8GraphFTPAccountFTP Loggin: name of account.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.7.5
wtWebioAn8GraphFTPOptionBit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.7.6
wtWebioAn8GraphFTPEnableSet Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.3.7.7
wtWebioAn8GraphDatalogger
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.4
wtWebioAn8GraphLoggerTimebaseTime base of the data loggerrw
Enumeration
.1.3.6.1.4.1.5040.1.2.6.3.1.4.1
wtWebioAn8GraphLoggerSensorSelBinary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.4.2
wtWebioAn8GraphDisplaySensorSelBinary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.4.3
wtWebioAn8GraphAutoScaleEnableIf bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.4.5
wtWebioAn8GraphVerticalUpperLimitThis value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.4.6
wtWebioAn8GraphVerticalLowerLimitThis value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.4.7
wtWebioAn8GraphHorizontalZoomDefines the default zoom stage, if no auto scaling is selected.rw
Enumeration
.1.3.6.1.4.1.5040.1.2.6.3.1.4.8
wtWebioAn8GraphAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.5
wtWebioAn8GraphAlarmCountNumber of independent alarms.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.5.1
wtWebioAn8GraphAlarmIfTableList of alarm indices.
SEQUENCE OF WtWebioAn8GraphAlarmIfEntry
.1.3.6.1.4.1.5040.1.2.6.3.1.5.2
wtWebioAn8GraphAlarmIfEntryNumbers of the alarms.
WtWebioAn8GraphAlarmIfEntry
.1.3.6.1.4.1.5040.1.2.6.3.1.5.2.1
wtWebioAn8GraphAlarmNoAlarm number.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.5.2.1.1
wtWebioAn8GraphAlarmTableList of settings depending on the alarm number.
SEQUENCE OF WtWebioAn8GraphAlarmEntry
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3
wtWebioAn8GraphAlarmEntryAlarm parameters of the individual alarms.
WtWebioAn8GraphAlarmEntry
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1
wtWebioAn8GraphAlarmTriggerBinary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.1
wtWebioAn8GraphAlarmMinMinimum temperature in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.2
wtWebioAn8GraphAlarmMaxMaximum temperature in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.3
wtWebioAn8GraphAlarmHysteresisTemperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.4
wtWebioAn8GraphAlarmDelayAlarm will be delayed by setting this time while stable alarm condition occur (time in minutes).rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.5
wtWebioAn8GraphAlarmIntervalSend interval for alarm messages.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.6
wtWebioAn8GraphAlarmEnableBinary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enablerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.7
wtWebioAn8GraphAlarmEMailAddrE-Mail address for sending the alarm mail to.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.8
wtWebioAn8GraphAlarmMailSubjectSubject line for alarm mail.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.9
wtWebioAn8GraphAlarmMailTextAlarm mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.10
wtWebioAn8GraphAlarmManagerIPName or IP address of the SNMP Manager which accepts the trap.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.11
wtWebioAn8GraphAlarmTrapTextThis text is sent in the trap body.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.12
wtWebioAn8GraphAlarmMailOptionsBinary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.13
wtWebioAn8GraphAlarmTcpIpAddrName or IP address of the TCP server which accepts the trap.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.14
wtWebioAn8GraphAlarmTcpPortPort number of the TCP server which accepts the trap.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.15
wtWebioAn8GraphAlarmTcpTextThis text is sent in the TCP trap body.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.16
wtWebioAn8GraphAlarmClearMailSubjectSubject line for alarm clear mail.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.17
wtWebioAn8GraphAlarmClearMailTextAlarm clear mail text: <Tn> provides the current temperature; n = 1..8. <Z> provides the current time.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.18
wtWebioAn8GraphAlarmClearTrapTextThis text is sent in the trap body.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.19
wtWebioAn8GraphAlarmClearTcpTextThis text is sent in the TCP trap body.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.20
wtWebioAn8GraphAlarmSyslogIpAddrIP address of the syslog server to which the Webio device should send syslog messages.rw
IpAddress
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.21
wtWebioAn8GraphAlarmSyslogPortPort number of the syslog server to which the Webio device should send syslog messages.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.22
wtWebioAn8GraphAlarmSyslogTextEvery message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.23
wtWebioAn8GraphAlarmSyslogClearTextEvery message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.24
wtWebioAn8GraphAlarmFtpDataPortLocal data port: 1..65535 or AUTO: the next free port will be assigned.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.25
wtWebioAn8GraphAlarmFtpFileNameName of the file including path informations.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.26
wtWebioAn8GraphAlarmFtpTextMessage text to store on the FTP server.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.27
wtWebioAn8GraphAlarmFtpClearTextAlarm clear message to store on the FTP server.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.28
wtWebioAn8GraphAlarmFtpOptionsBinary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.29
wtWebioAn8GraphAlarmTimerCronThis entry contains 5 text fields space or tab seperated for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute).rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.5.3.1.30
wtWebioAn8GraphGraphics
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.6
wtWebioAn8GraphGraphicsBase
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.1
wtWebioAn8GraphGraphicsBaseEnableDefines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.1.1
wtWebioAn8GraphGraphicsBaseWidthDefines the width of the graphic in pixels.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.1.2
wtWebioAn8GraphGraphicsBaseHeightDefines the height of the graphic in pixels.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.1.3
wtWebioAn8GraphGraphicsBaseFrameColorFrame color definition in RGB.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.1.4
wtWebioAn8GraphGraphicsBaseBackgroundColorBackground color definition in RGB.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.1.5
wtWebioAn8GraphGraphicsBasePollingrateDefines the pollingrate in seconds, which defines the refreshing intervall of the graphic.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.1.6
wtWebioAn8GraphGraphicsSelect
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.2
wtWebioAn8GraphGraphicsSelectDisplaySensorSelBinary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.2.1
wtWebioAn8GraphGraphicsSelectDisplayShowExtremBinary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.2.2
wtWebioAn8GraphSensorColorTableList of sensor colors for the praphical presentation.
SEQUENCE OF WtWebioAn8GraphSensorColorEntry
.1.3.6.1.4.1.5040.1.2.6.3.1.6.2.3
wtWebioAn8GraphSensorColorEntryNumbers of the sensors.
WtWebioAn8GraphSensorColorEntry
.1.3.6.1.4.1.5040.1.2.6.3.1.6.2.3.1
wtWebioAn8GraphSensorColorColor of the sensors at the praphical presention.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.2.3.1.1
wtWebioAn8GraphGraphicsSensorColorColor of the sensors at the praphical presention.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.2.3.1.1
wtWebioAn8GraphGraphicsSelectScaleAssignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3 : Use Scale 4 Bit 4-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.2.3.1.2
wtWebioAn8GraphGraphicsScale
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3
wtWebioAn8GraphGraphicsScaleAutoScaleEnableSelect the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2 : Scale 3 Auto scale enable Bit 3 : Scale 4 Auto scale enable Bit 4-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.1
wtWebioAn8GraphGraphicsScaleAutoFitEnableSelect the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2 : Scale 3 Auto fit enable Bit 3 : Scale 4 Auto fit enable Bit 4-7: unusedrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.2
wtWebioAn8GraphGraphicsScale1MinScale 1: Minimum.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.3
wtWebioAn8GraphGraphicsScale2MinScale 2: Minimum.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.4
wtWebioAn8GraphGraphicsScale3MinScale 3: Minimum.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.5
wtWebioAn8GraphGraphicsScale4MinScale 4: Minimum.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.6
wtWebioAn8GraphGraphicsScale1MaxScale 1: Maximum.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.7
wtWebioAn8GraphGraphicsScale2MaxScale 2: Maximum.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.8
wtWebioAn8GraphGraphicsScale3MaxScale 3: Maximum.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.9
wtWebioAn8GraphGraphicsScale4MaxScale 4: Maximum.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.10
wtWebioAn8GraphGraphicsScale1UnitScale 1: Unit.ro
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.11
wtWebioAn8GraphGraphicsScale2UnitScale 2: Unit.ro
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.12
wtWebioAn8GraphGraphicsScale3UnitScale 3: Unit.ro
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.13
wtWebioAn8GraphGraphicsScale4UnitScale 4: Unit.ro
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.1.6.3.14
wtWebioAn8GraphPorts
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.2
wtWebioAn8GraphPortTableList of settings depending on the sensor number.
SEQUENCE OF WtWebioAn8GraphPortEntry
.1.3.6.1.4.1.5040.1.2.6.3.2.1
wtWebioAn8GraphPortEntrySensor parameters for the individual sensors.
WtWebioAn8GraphPortEntry
.1.3.6.1.4.1.5040.1.2.6.3.2.1.1
wtWebioAn8GraphPortNameName of the sensor.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.2.1.1.1
wtWebioAn8GraphPortTextDescription of the sensor.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.2.1.1.2
wtWebioAn8GraphPortOffset1Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.2.1.1.3
wtWebioAn8GraphPortTemperature1Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.2.1.1.4
wtWebioAn8GraphPortOffset2Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.2.1.1.5
wtWebioAn8GraphPortTemperature2Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.2.1.1.6
wtWebioAn8GraphPortCommentOffset calibration: informations of date, name of operator, reference devices.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.2.1.1.7
wtWebioAn8GraphPortSensorSelectBinr kodierte Optionen fr Sensor: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: ungenutztrw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.2.1.1.8
wtWebioAn8GraphManufact
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.3.3
wtWebioAn8GraphMfNameManufacturer company namerw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.3.1
wtWebioAn8GraphMfAddrManufacturer address.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.3.2
wtWebioAn8GraphMfHotlineManufacturer hotline.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.3.3
wtWebioAn8GraphMfInternetManufacturer Internet address.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.3.4
wtWebioAn8GraphMfDeviceTypManufacturer device name (model number).rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.3.5
wtWebioAn8GraphMfOrderNoManufacturer part number.rw
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.3.3.6
wtWebioAn8GraphDiag
OBJECT IDENTIFIER
.1.3.6.1.4.1.5040.1.2.6.4
wtWebioAn8GraphDiagErrorCountNumber of entries in the error memory.ro
INTEGER
.1.3.6.1.4.1.5040.1.2.6.4.1
wtWebioAn8GraphDiagBinaryErrorError causes coded bit-by-bit.ro
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.4.2
wtWebioAn8GraphDiagErrorIndexThe value of this variable is used as an index to read an error massege from wtWebioAn8GraphDiagErrorMessage. Errors are numbered from 1 to wtWebioAn8GraphDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioAn8GraphDiagErrorMessage.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.4.3
wtWebioAn8GraphDiagErrorMessageUsing wtWebioAn8GraphDiagErrorIndex as an index, the appropriate message is available.ro
OCTET STRING
.1.3.6.1.4.1.5040.1.2.6.4.4
wtWebioAn8GraphDiagErrorClearWriting 1 into this variable clears all diagnosis messages.rw
INTEGER
.1.3.6.1.4.1.5040.1.2.6.4.5