Home/Catalog/VERTICAL-ENV-MIB

VERTICAL-ENV-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for VERTICAL-ENV-MIB.

17
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

17 total
Object Name
vertical
OBJECT IDENTIFIER
.1.3.6.1.4.1.2338
RFC1213-MIB
Unknown
.1.3.6.1.4.1.2338
environment
OBJECT IDENTIFIER
.1.3.6.1.4.1.2338.11
iOFanTableTable of status information about all Instant Office cooling fans
SEQUENCE OF IOFanEntry
.1.3.6.1.4.1.2338.11.1
iOFanEntryAn entry in the Fan Table.
IOFanEntry
.1.3.6.1.4.1.2338.11.1.1
fanIndexThe index of the cooling fan within the systemro
INTEGER
.1.3.6.1.4.1.2338.11.1.1.1
fanOperStatusThe operational status of this fan. The following are valid values: running =1,(the normal operational state), stopped =2, unknown =3ro
Enumeration
.1.3.6.1.4.1.2338.11.1.1.2
iOPSTableTable of status information about all Instant Office power supplies
SEQUENCE OF IOPSEntry
.1.3.6.1.4.1.2338.11.2
iOPSEntryAn entry in the Power Supply Table.
IOPSEntry
.1.3.6.1.4.1.2338.11.2.1
psIndexThe index of the power supply unit within the systemro
INTEGER
.1.3.6.1.4.1.2338.11.2.1.1
psOperStatusThe operational status of this power supply. The following are valid values: on=1, off=2, unknown=3ro
Enumeration
.1.3.6.1.4.1.2338.11.2.1.2
iOFaultMonitorGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2338.11.3
iOFaultMonitorStatusThe operational status of the Fault Monitor. The following are valid values: RAMFull =1, NotResponding =2, Ok =3, ModemFailed =4ro
Enumeration
.1.3.6.1.4.1.2338.11.3.1
iOTrapInfoGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2338.11.4
iOLastFanTrapThis object describes,in more detail,the last Fan Trap event that occured. Since traps for all fans are combined into one Trap, this string describes each fan status just after the trap condition.ro
DisplayString
.1.3.6.1.4.1.2338.11.4.1
iOLastPowerSupplyTrapThis object describes,in more detail,the last Power Supply Trap event that occured. Since traps for all power supplies are combined into one Trap, this string describes each power supply status just after the trap condition.ro
DisplayString
.1.3.6.1.4.1.2338.11.4.2
iOLastFaultMonitorTrapThis object describes,in more detail,the last Fault Monitor Trap event that occured. Since traps for all Fault Monitor events are combined into one Trap,this string describes the Fault Monitor event (RAM full, NotResponding or Modem Failed) that caused this trap.ro
DisplayString
.1.3.6.1.4.1.2338.11.4.3