Home/Catalog/TPLINK-SFLOW-MIB

TPLINK-SFLOW-MIB

Private MIB for the sFlow configuration.
Main OID:
tplinkSflowMIB.1.3.6.1.4.1.11863.6.95
26
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

26 total
Object Name
tplinkSflowMIBPrivate MIB for the sFlow configuration.
MODULE-IDENTITY
.1.3.6.1.4.1.11863.6.95
IMPORTSPrivate MIB for the sFlow configuration.
Unknown
.1.3.6.1.4.1.11863.6.95
tplinkSflowMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.11863.6.95.1
tpSflowGlobalConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.11863.6.95.1.1
tpSflowGlobalConfigStatusAllows you to Enable/Disable the sFlow function. 0. disable 1. enablerw
Enumeration
.1.3.6.1.4.1.11863.6.95.1.1.1
tpSflowGlobalConfigAddressThe IP address of the agent.rw
IpAddress
.1.3.6.1.4.1.11863.6.95.1.1.2
tpSflowGlobalConfigVersionThe sFlow version number.ro
INTEGER
.1.3.6.1.4.1.11863.6.95.1.1.3
tpSflowCollector
OBJECT IDENTIFIER
.1.3.6.1.4.1.11863.6.95.1.2
tpSflowCollectorTableA list of sflow collector entries. Here you can configure the sflow collector.
SEQUENCE OF TpSflowCollectorEntry
.1.3.6.1.4.1.11863.6.95.1.2.1
tpSflowCollectorEntryAn entry contains the information of sflow collector.
TpSflowCollectorEntry
.1.3.6.1.4.1.11863.6.95.1.2.1.1
tpSflowCollectorCollectorIdThe collector ID.ro
INTEGER
.1.3.6.1.4.1.11863.6.95.1.2.1.1.1
tpSflowCollectorDescriptionThis description of the collector.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11863.6.95.1.2.1.1.2
tpSflowCollectorCollectorIpThe IP address of the collectorrw
IpAddress
.1.3.6.1.4.1.11863.6.95.1.2.1.1.3
tpSflowCollectorCollectorPortThe UDP port of the collector.rw
INTEGER
.1.3.6.1.4.1.11863.6.95.1.2.1.1.4
tpSflowCollectorMaxDatagramThe max datagram of the collector.rw
INTEGER
.1.3.6.1.4.1.11863.6.95.1.2.1.1.5
tpSflowCollectorTimeoutThe timeout value of the collector.rw
INTEGER
.1.3.6.1.4.1.11863.6.95.1.2.1.1.6
tpSflowCollectorLifetimeThe lifetime of the collector.ro
INTEGER
.1.3.6.1.4.1.11863.6.95.1.2.1.1.7
tpSflowSampler
OBJECT IDENTIFIER
.1.3.6.1.4.1.11863.6.95.1.3
tpSflowSamplerTableA list of sflow sampler entries. Here you can configure the sflow sampler.
SEQUENCE OF TpSflowSamplerEntry
.1.3.6.1.4.1.11863.6.95.1.3.1
tpSflowSamplerEntryAn entry contains the information of the sflow sampler.
TpSflowSamplerEntry
.1.3.6.1.4.1.11863.6.95.1.3.1.1
tpSflowSamplerPortThe port number of the switch.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.11863.6.95.1.3.1.1.1
tpSflowSamplerCollectorIdThe collector ID.rw
INTEGER
.1.3.6.1.4.1.11863.6.95.1.3.1.1.2
tpSflowSamplerIngRateThe ratio of ingress packets to the samples generated(Range:0, 1024-65535).rw
INTEGER
.1.3.6.1.4.1.11863.6.95.1.3.1.1.3
tpSflowSamplerEgRateThe ratio of egress packets to the samples generated(Range:0, 1024-65535).rw
INTEGER
.1.3.6.1.4.1.11863.6.95.1.3.1.1.4
tpSflowSamplerMaxHeaderThe maximum number of bytes that should be sampled.rw
INTEGER
.1.3.6.1.4.1.11863.6.95.1.3.1.1.5
tpSflowSamplerPortLagThe LAG number which the port belongs to.ro
OCTET STRING
.1.3.6.1.4.1.11863.6.95.1.3.1.1.6
TPLINK-SFLOW-MIB - SNMP MIB Reference | MIBs Explorer