TPLINK-SFLOW-MIB
Private MIB for the sFlow configuration.
Main OID:
tplinkSflowMIB.1.3.6.1.4.1.11863.6.95
26
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
26 total| Object Name |
|---|
tplinkSflowMIBPrivate MIB for the sFlow configuration. MODULE-IDENTITY .1.3.6.1.4.1.11863.6.95 |
IMPORTSPrivate MIB for the sFlow configuration. Unknown .1.3.6.1.4.1.11863.6.95 |
tplinkSflowMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.11863.6.95.1 |
tpSflowGlobalConfig OBJECT IDENTIFIER .1.3.6.1.4.1.11863.6.95.1.1 |
tpSflowGlobalConfigStatusAllows you to Enable/Disable the sFlow function.
0. disable
1. enablerw Enumeration .1.3.6.1.4.1.11863.6.95.1.1.1 |
tpSflowGlobalConfigAddressThe IP address of the agent.rw IpAddress .1.3.6.1.4.1.11863.6.95.1.1.2 |
tpSflowGlobalConfigVersionThe sFlow version number.ro INTEGER .1.3.6.1.4.1.11863.6.95.1.1.3 |
tpSflowCollector OBJECT IDENTIFIER .1.3.6.1.4.1.11863.6.95.1.2 |
tpSflowCollectorTableA list of sflow collector entries.
Here you can configure the sflow collector. SEQUENCE OF TpSflowCollectorEntry .1.3.6.1.4.1.11863.6.95.1.2.1 |
tpSflowCollectorEntryAn entry contains the information of sflow collector. TpSflowCollectorEntry .1.3.6.1.4.1.11863.6.95.1.2.1.1 |
tpSflowCollectorCollectorIdThe collector ID.ro INTEGER .1.3.6.1.4.1.11863.6.95.1.2.1.1.1 |
tpSflowCollectorDescriptionThis description of the collector.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11863.6.95.1.2.1.1.2 |
tpSflowCollectorCollectorIpThe IP address of the collectorrw IpAddress .1.3.6.1.4.1.11863.6.95.1.2.1.1.3 |
tpSflowCollectorCollectorPortThe UDP port of the collector.rw INTEGER .1.3.6.1.4.1.11863.6.95.1.2.1.1.4 |
tpSflowCollectorMaxDatagramThe max datagram of the collector.rw INTEGER .1.3.6.1.4.1.11863.6.95.1.2.1.1.5 |
tpSflowCollectorTimeoutThe timeout value of the collector.rw INTEGER .1.3.6.1.4.1.11863.6.95.1.2.1.1.6 |
tpSflowCollectorLifetimeThe lifetime of the collector.ro INTEGER .1.3.6.1.4.1.11863.6.95.1.2.1.1.7 |
tpSflowSampler OBJECT IDENTIFIER .1.3.6.1.4.1.11863.6.95.1.3 |
tpSflowSamplerTableA list of sflow sampler entries.
Here you can configure the sflow sampler. SEQUENCE OF TpSflowSamplerEntry .1.3.6.1.4.1.11863.6.95.1.3.1 |
tpSflowSamplerEntryAn entry contains the information of the sflow sampler. TpSflowSamplerEntry .1.3.6.1.4.1.11863.6.95.1.3.1.1 |
tpSflowSamplerPortThe port number of the switch.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.11863.6.95.1.3.1.1.1 |
tpSflowSamplerCollectorIdThe collector ID.rw INTEGER .1.3.6.1.4.1.11863.6.95.1.3.1.1.2 |
tpSflowSamplerIngRateThe ratio of ingress packets to the samples generated(Range:0, 1024-65535).rw INTEGER .1.3.6.1.4.1.11863.6.95.1.3.1.1.3 |
tpSflowSamplerEgRateThe ratio of egress packets to the samples generated(Range:0, 1024-65535).rw INTEGER .1.3.6.1.4.1.11863.6.95.1.3.1.1.4 |
tpSflowSamplerMaxHeaderThe maximum number of bytes that should be sampled.rw INTEGER .1.3.6.1.4.1.11863.6.95.1.3.1.1.5 |
tpSflowSamplerPortLagThe LAG number which the port belongs to.ro OCTET STRING .1.3.6.1.4.1.11863.6.95.1.3.1.1.6 |