T11-IETF-IMSS-FC-VIRTUAL-FABRIC-MIB
The T11-IETF-IMSS-FC-VIRTUAL-FABRIC-MIB enables the monitoring and management of Fibre Channel Virtual Fabric partitions, specifically tracking switch link states, N_Port configurations, and the isolation of Fabric Services within a single management domain. It facilitates the administration of logical fabric independence by exposing metrics related to virtual fabric membership, partition boundaries, and associated Fabric Services availability.
Imported Objects
Objects
20 total| Object Name |
|---|
t11vfLocallyEnabledRowStatusThe status of this conceptual row.rw RowStatus (SNMPv2-TC) .1.3.6.1.2.1.147.1.4.1.4 |
t11FcVirtualFabricMIBThis module defines management information specific to
Fibre Channel Virtual Fabrics. A Virtual Fabric is a
Fabric composed of partitions of switches, links and N_Ports
with a single Fabric management domain, Fabric Services
and independence from other Virtual Fabrics.
Copyright (C) The Internet Society (2005). This version of
this MIB module is part of RFC yyyy; see the RFC itself for
full legal notices. MODULE-IDENTITY .1.3.6.1.4.1.3727.20.20.3.1.nnn |
t11vfObjects OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.nnn.1 |
t11vfCoreSwitchTableA table of core switches supported by the current
management entity. SEQUENCE OF T11vfCoreSwitchEntry .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.1 |
t11vfCoreSwitchEntryEach entry represents one core switch. T11vfCoreSwitchEntry .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.1.1 |
t11vfCoreSwitchSwitchNameThe Core Switch_Name (WWN) of this Core Switch. A
zero-length string for this field is not allowed. FcNameIdOrZero (FC-MGMT-MIB) .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.1.1.1 |
t11vfCoreSwitchMaxSupportedIn switches that do not support Virtual Fabrics,
this object has the value of 1. If Virtual Fabrics
are supported, this object is the maximum number of
Virtual Fabrics supported by the Core Switch. For
the purpose of this count, the Control VF_ID is
ignored.rw Unsigned32 .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.1.1.2 |
t11vfVirtualSwitchTableA table of Virtual Switches. When one Core Switch
provides switching functions for multiple Virtual Fabrics,
that Core Switch is modeled as containing multiple
Virtual Switches, one for each Virtual Fabric. This table
contains one row for every Virtual Switch on every Core
Switch. This table augments the basic switch information in
the fcmSwitchTable Table in the FCMGMT-MIB. SEQUENCE OF T11vfVirtualSwitchEntry .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.2 |
t11vfVirtualSwitchEntryAn entry of the Virtual Switch table. Each row is for a
Virtual Switch. T11vfVirtualSwitchEntry .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.2.1 |
t11vfVirtualSwitchVfIdThe VF_ID of the Virtual Fabric for which this virtual
switch performs its switching function. The Control
VF_ID is implicitly enabled and is not set.
Communication with the Control VF_ID is required.rw T11FabricIndex (T11-TC-MIB) .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.2.1.1 |
t11vfVirtualSwitchCoreSwitchNameThe Core Switch_Name (WWN) of the Core Switch that
contains this Virtual Switch.ro FcNameIdOrZero (FC-MGMT-MIB) .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.2.1.2 |
t11vfVirtualSwitchRowStatusThe status of this row.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.2.1.3 |
t11vfPortTableA table of Port attributes related to Virtual Fabrics. SEQUENCE OF T11vfPortEntry .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.3 |
t11vfPortEntryEach entry represents a physical Port on a switch. T11vfPortEntry .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.3.1 |
t11vfPortVfIdThe Port VF_ID assigned to this Port. The Port VF_ID is the
default Virtual Fabric that is assigned to untagged frames
arriving at this Port. The Control VF_ID is implicitly
enabled and is not set. Communication with the Control
VF_ID is required.rw T11FabricIndex (T11-TC-MIB) .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.3.1.1 |
t11vfPortTaggingAdminStatusThis object is used to configure the administrative status
of Virtual Fabric tagging on this Port.
SET operation Description
-
off(1) To disable Virtual Fabric tagging on this
Port.
on(2) To enable Virtual Fabric tagging on this
Port if the attached Port doesn't
prohibit it.
auto(3) To enable Virtual Fabric tagging if the
peer requests it.rw Enumeration .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.3.1.2 |
t11vfPortTaggingOperStatusThis object is used to report the operational status of
Virtual Fabric tagging on this Port.
SET operation Description
-
Internet Draft Virtual Fabrics MIB September 2005
off(1) Virtual Fabric tagging is disabled on this
Port.
on(2) Virtual Fabric tagging is enabled on this
Port.
REFERENCEro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.nnn.1.3.1.3 |
t11vfConformance OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.nnn.2 |
t11vfMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.nnn.2.1 |
t11vfMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.nnn.2.2 |
More MIBs from Pseudowire Edge-to-Edge Emulation (PWE3)
Browse all Pseudowire Edge-to-Edge Emulation (PWE3)MIBs →The SUPERCAPBATTERY-MIB module provides SNMP objects to monitor the voltage, current, temperature, and remaining capacity of supercapacitor-based backup power units and their associated battery management systems on networked infrastructure. It enables administrators to track charge levels and health status of these energy storage components to prevent unexpected device shutdowns during power failures.
The VSL2-LINE-MIB module provides a unified management framework for monitoring VDSL2, ADSL, ADSL2, and ADSL2+ physical line interfaces, exposing standardized counters and status objects defined by ITU-T G.99x series and DSL Forum TR-129 specifications. It facilitates the collection of critical performance metrics such as line attenuation, signal-to-noise ratio, and error counts (FEC/HEC) across these copper-based broadband technologies via the SNMP MIB-2 transmission hierarchy.