OTN-MIB
The draft MIB module to describe OTN interfaces objects.
Main OID:
optIfMibModule.1.3.6.1.4.1.3727.20.20.3.1.10.1
294
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
294 total| Object Name |
|---|
optIfODUkTTIMActEnabledIndicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled.rw TruthValue (SNMPv2-TC) .1.3.6.1.2.1.10.133.1.9.1.1.7 |
optIfMibModuleThe draft MIB module to describe OTN interfaces objects. MODULE-IDENTITY .1.3.6.1.4.1.3727.20.20.3.1.10.1 |
optIfObjects OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.10.1.1 |
optIfPerfMon OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.1 |
optIfPerfMonCurrentTimeElapsedNumber of seconds elapsed in the current 15 minute
performance monitoring interval.ro Gauge32 .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.1.1 |
optIfPerfMonCurDayTimeElapsedNumber of seconds elapsed in the current calendar day
performance monitoring period.ro Gauge32 .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.1.2 |
optIfPerfMonIntervalTableA table of 15 minute performance monitoring interval
information. SEQUENCE OF OptIfPerfMonIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.1.3 |
optIfPerfMonIntervalEntryA conceptual row that contains 15 minute performance
monitoring interval information of an interface. OptIfPerfMonIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.1.3.1 |
optIfPerfMonIntervalNumIntervalsThe number of 15 minute intervals for which performance
monitoring data is available. The number is the same for all
the associated sub layers of the interface.
An optical interface must be capable of supporting at least
n intervals, where n is defined as follows:
The minimum value of n is 4.
The default of n is 32.
The maximum value of n is 96.
The value of this object will be n unless performance
monitoring was (re-)started for the interface within the last
(n*15) minutes, in which case the value will be the number of
complete 15 minute intervals since measurement was
(re-)started.ro Unsigned32 .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.1.3.1.1 |
optIfPerfMonIntervalNumInvalidIntervalsThe number of intervals in the range from 0 to
optIfPerfMonIntervalNumIntervals for which no performance
monitoring data is available and/or the data is invalid.ro Unsigned32 .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.1.3.1.2 |
optIfOTSn OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2 |
optIfOTSnConfigTableA table of OTSn configuration information. SEQUENCE OF OptIfOTSnConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1 |
optIfOTSnConfigEntryA conceptual row that contains OTSn configuration
information of an interface. OptIfOTSnConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1.1 |
optIfOTSnTraceIdentifierTransmittedThe trace identifier transmitted.rw SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1.1.1 |
optIfOChSinkAdaptActiveIndicates whether the sink adaptation function is activated or not.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1.1.1 |
optIfOTSnDAPIExpectedThe DAPI expected by the receiver.rw SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1.1.2 |
optIfOChSourceAdaptActiveIndicates whether the source adaptation function is activated or
not.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1.1.2 |
optIfOTSnSAPIExpectedThe SAPI expected by the receiver.rw SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1.1.3 |
optIfOChSinkFECEnabledIf Forward Error Correction (FEC) is supported, this object
indicates whether FEC at the OCh sink adaptation function is
enabled or not.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1.1.3 |
optIfOTSnTraceIdentifierAcceptedThe actual trace identifier received.ro SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1.1.4 |
optIfOTSnAcTIStatusThe status of the accepted Trail Trace Identifier by the receiver.ro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1.1.5 |
optIfOTSnTIMDetModeIndicates the mode of the Trace Identifier Mismatch (TIM)
Detection function.rw Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1.1.6 |
optIfOTSnTIMActEnabledIndicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1.1.7 |
optIfOTSnCurrentStatusIndicates the failure condition of the entity, if any.ro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.1.1.8 |
optIfOTSnSinkCurrentTableA table of OTSn sink performance monitoring information for
the current 15 minute interval. SEQUENCE OF OptIfOTSnSinkCurrentEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.2 |
optIfOTSnSinkCurrentEntryA conceptual row that contains OTSn sink performance
monitoring information of an interface for the current
15 minute interval. OptIfOTSnSinkCurrentEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.2.1 |
optIfOTSnSinkCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.2.1.1 |
optIfOTSnSinkCurrentInputPowerThe optical power monitored at the input.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.2.1.2 |
optIfOTSnSinkCurrentLowInputPowerThe lowest optical power monitored at the input during the
current interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.2.1.3 |
optIfOTSnSinkCurrentHighInputPowerThe highest optical power monitored at the input during the
current interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.2.1.4 |
optIfOTSnSinkCurrentLowerInputPowerThresholdThe lower limit threshold on input power. If
optIfOTSnSinkCurrentInputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.2.1.5 |
optIfOTSnSinkCurrentUpperInputPowerThresholdThe upper limit threshold on input power. If
optIfOTSnSinkCurrentInputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.2.1.6 |
optIfOTSnSinkIntervalTableA table of historical OTSn sink performance monitoring
information. SEQUENCE OF OptIfOTSnSinkIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.3 |
optIfOTSnSinkIntervalEntryA conceptual row that contains OTSn sink performance
monitoring information of an interface during a particular
historical interval. OptIfOTSnSinkIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.3.1 |
optIfOTSnSinkIntervalNumberUniquely identifies the interval. IntervalNumber .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.3.1.1 |
optIfOTSnSinkIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.3.1.2 |
optIfOTSnSinkIntervalLastInputPowerThe last optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.3.1.3 |
optIfOTSnSinkIntervalLowInputPowerThe lowest optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.3.1.4 |
optIfOTSnSinkIntervalHighInputPowerThe highest optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.3.1.5 |
optIfOTSnSinkCurDayTableA table of OTSn sink performance monitoring information for
the current calendar day. SEQUENCE OF OptIfOTSnSinkCurDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.4 |
optIfOTSnSinkCurDayEntryA conceptual row that contains OTSn sink performance
monitoring information of an interface for the current
calendar day. OptIfOTSnSinkCurDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.4.1 |
optIfOTSnSinkCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.4.1.1 |
optIfOTSnSinkCurDayLowInputPowerThe lowest optical power monitored at the input during the
current calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.4.1.2 |
optIfOTSnSinkCurDayHighInputPowerThe highest optical power monitored at the input during the
current calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.4.1.3 |
optIfOTSnSinkPrevDayTableA table of OTSn sink performance monitoring information for
the previous calendar day. SEQUENCE OF OptIfOTSnSinkPrevDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.5 |
optIfOTSnSinkPrevDayEntryA conceptual row that contains OTSn sink performance
monitoring information of an interface for the previous
calendar day. OptIfOTSnSinkPrevDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.5.1 |
optIfOTSnSinkPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.5.1.1 |
optIfOTSnSinkPrevDayLastInputPowerThe last optical power monitored at the input during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.5.1.2 |
optIfOTSnSinkPrevDayLowInputPowerThe lowest optical power monitored at the input during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.5.1.3 |
optIfOTSnSinkPrevDayHighInputPowerThe highest optical power monitored at the input during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.5.1.4 |
optIfOTSnSrcCurrentTableA table of OTSn source performance monitoring information for
the current 15 minute interval. SEQUENCE OF OptIfOTSnSrcCurrentEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6 |
optIfOTSnSrcCurrentEntryA conceptual row that contains OTSn source performance
monitoring information of an interface for the current
15 minute interval. OptIfOTSnSrcCurrentEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6.1 |
optIfOTSnSrcCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6.1.1 |
optIfOTSnSrcCurrentOutputPowerThe optical power monitored at the output.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6.1.2 |
optIfOTSnSrcCurrentLowOutputPowerThe lowest optical power monitored at the output during the
current interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6.1.3 |
optIfOTSnSrcCurrentHighOutputPowerThe highest optical power monitored at the output during the
current interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6.1.4 |
optIfOTSnSrcCurrentLowerOutputPowerThresholdThe lower limit threshold on output power. If
optIfOTSnSrcCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6.1.5 |
optIfOTSnSrcCurrentUpperOutputPowerThresholdThe upper limit threshold on output power. If
optIfOTSnSrcCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6.1.6 |
optIfOTSnSrcCurrentLaserTempThe operating temperature of the laser.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6.1.7 |
optIfOTSnSrcCurrentLowLaserTempThe lowest operating temperature of the laser during the
current interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6.1.8 |
optIfOTSnSrcCurrentHighLaserTempThe highest operating temperature of the laser during the
current interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6.1.9 |
optIfOTSnSrcCurrentLowerLaserTempThresholdThe lower limit threshold on laser temperature. If
optIfOTSnSrcCurrentLaserTemp drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6.1.10 |
optIfOTSnSrcCurrentUpperLaserTempThresholdThe upper limit threshold on laser temperature. If
optIfOTSnSrcCurrentLaserTemp reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.6.1.11 |
optIfOTSnSrcIntervalTableA table of historical OTSn source performance monitoring
information. SEQUENCE OF OptIfOTSnSrcIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.7 |
optIfOTSnSrcIntervalEntryA conceptual row that contains OTSn source performance
monitoring information of an interface during a particular
historical interval. OptIfOTSnSrcIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.7.1 |
optIfOTSnSrcIntervalNumberUniquely identifies the interval. IntervalNumber .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.7.1.1 |
optIfOTSnSrcIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.7.1.2 |
optIfOTSnSrcIntervalLastOutputPowerThe last optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.7.1.3 |
optIfOTSnSrcIntervalLowOutputPowerThe lowest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.7.1.4 |
optIfOTSnSrcIntervalHighOutputPowerThe highest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.7.1.5 |
optIfOTSnSrcIntervalLastLaserTempThe last operating temperature of the laser during the
interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.7.1.6 |
optIfOTSnSrcIntervalLowLaserTempThe lowest operating temperature of the laser during the
interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.7.1.7 |
optIfOTSnSrcIntervalHighLaserTempThe highest operating temperature of the laser during the
interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.7.1.8 |
optIfOTSnSrcCurDayTableA table of OTSn source performance monitoring information for
the current calendar day. SEQUENCE OF OptIfOTSnSrcCurDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.8 |
optIfOTSnSrcCurDayEntryA conceptual row that contains OTSn source performance
monitoring information of an interface for the current
calendar day. OptIfOTSnSrcCurDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.8.1 |
optIfOTSnSrcCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.8.1.1 |
optIfOTSnSrcCurDayLowOutputPowerThe lowest optical power monitored at the output during the
current calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.8.1.2 |
optIfOTSnSrcCurDayHighOutputPowerThe highest optical power monitored at the output during the
current calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.8.1.3 |
optIfOTSnSrcCurDayLowLaserTempThe lowest operating temperature of the laser during the
current calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.8.1.4 |
optIfOTSnSrcCurDayHighLaserTempThe highest operating temperature of the laser during the
current calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.8.1.5 |
optIfOTSnSrcPrevDayTableA table of OTSn source performance monitoring information for
the previous calendar day. SEQUENCE OF OptIfOTSnSrcPrevDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.9 |
optIfOTSnSrcPrevDayEntryA conceptual row that contains OTSn source performance
monitoring information of an interface for the previous
calendar day. OptIfOTSnSrcPrevDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.9.1 |
optIfOTSnSrcPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.9.1.1 |
optIfOTSnSrcPrevDayLastOutputPowerThe last optical power monitored at the output during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.9.1.2 |
optIfOTSnSrcPrevDayLowOutputPowerThe lowest optical power monitored at the output during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.9.1.3 |
optIfOTSnSrcPrevDayHighOutputPowerThe highest optical power monitored at the output during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.9.1.4 |
optIfOTSnSrcPrevDayLastLaserTempThe last operating temperature of the laser during the
previous calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.9.1.5 |
optIfOTSnSrcPrevDayLowLaserTempThe lowest operating temperature of the laser during the
previous calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.9.1.6 |
optIfOTSnSrcPrevDayHighLaserTempThe highest operating temperature of the laser during the
previous calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.2.9.1.7 |
optIfOMSn OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3 |
optIfOMSnConfigTableA table of OMSn configuration information. SEQUENCE OF OptIfOMSnConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.1 |
optIfOMSnConfigEntryA conceptual row that contains OMSn configuration
information of an interface. OptIfOMSnConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.1.1 |
optIfOMSnOrderThe number of multiplexed optical channels.ro Unsigned32 .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.1.1.1 |
optIfOMSnCurrentStatusIndicates the failure condition of the entity, if any.ro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.1.1.2 |
optIfOMSnSinkCurrentTableA table of OMSn sink performance monitoring information for
the current 15 minute interval. SEQUENCE OF OptIfOMSnSinkCurrentEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2 |
optIfOMSnSinkCurrentEntryA conceptual row that contains OMSn sink performance
monitoring information of an interface for the current
15 minute interval. OptIfOMSnSinkCurrentEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2.1 |
optIfOMSnSinkCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2.1.1 |
optIfOMSnSinkCurrentAggregatedInputPowerThe aggregated optical power of all the DWDM input
channels.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2.1.2 |
optIfOMSnSinkCurrentLowAggregatedInputPowerThe lowest aggregated optical power of all the DWDM input
channels during the current interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2.1.3 |
optIfOMSnSinkCurrentHighAggregatedInputPowerThe highest aggregated optical power of all the DWDM input
channels during the current interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2.1.4 |
optIfOMSnSinkCurrentLowerInputPowerThresholdThe lower limit threshold on aggregated input power. If
optIfOMSnSinkCurrentAggregatedInputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2.1.5 |
optIfOMSnSinkCurrentUpperInputPowerThresholdThe upper limit threshold on aggregated input power. If
optIfOMSnSinkCurrentAggregatedInputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2.1.6 |
optIfOMSnSinkCurrentLaserTempThe operating temperature of the laser.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2.1.7 |
optIfOMSnSinkCurrentLowLaserTempThe lowest operating temperature of the laser during the
current interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2.1.8 |
optIfOMSnSinkCurrentHighLaserTempThe highest operating temperature of the laser during the
current interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2.1.9 |
optIfOMSnSinkCurrentLowerLaserTempThresholdThe lower limit threshold on laser temperature. If
optIfOMSnSinkCurrentLaserTemp drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2.1.10 |
optIfOMSnSinkCurrentUpperLaserTempThresholdThe upper limit threshold on aggregated input power. If
optIfOMSnSinkCurrentLaserTemp reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.2.1.11 |
optIfOMSnSinkIntervalTableA table of historical OMSn sink performance monitoring
information. SEQUENCE OF OptIfOMSnSinkIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.3 |
optIfOMSnSinkIntervalEntryA conceptual row that contains OMSn sink performance
monitoring information of an interface during a particular
historical interval. OptIfOMSnSinkIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.3.1 |
optIfOMSnSinkIntervalNumberUniquely identifies the interval. IntervalNumber .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.3.1.1 |
optIfOMSnSinkIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.3.1.2 |
optIfOMSnSinkIntervalLastAggregatedInputPowerThe last aggregated optical power of all the DWDM input
channels during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.3.1.3 |
optIfOMSnSinkIntervalLowAggregatedInputPowerThe lowest aggregated optical power of all the DWDM input
channels during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.3.1.4 |
optIfOMSnSinkIntervalHighAggregatedInputPowerThe highest aggregated optical power of all the DWDM input
channels during the interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.3.1.5 |
optIfOMSnSinkIntervalLastLaserTempThe last operating temperature of the laser during the
interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.3.1.6 |
optIfOMSnSinkIntervalLowLaserTempThe lowest operating temperature of the laser during the
interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.3.1.7 |
optIfOMSnSinkIntervalHighLaserTempThe highest operating temperature of the laser during the
interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.3.1.8 |
optIfOMSnSinkCurDayTableA table of OMSn sink performance monitoring information for
the current calendar day. SEQUENCE OF OptIfOMSnSinkCurDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.4 |
optIfOMSnSinkCurDayEntryA conceptual row that contains OMSn sink performance
monitoring information of an interface for the current
calendar day. OptIfOMSnSinkCurDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.4.1 |
optIfOMSnSinkCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.4.1.1 |
optIfOMSnSinkCurDayLowAggregatedInputPowerThe lowest aggregated optical power of all the DWDM input
channels during the current calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.4.1.2 |
optIfOMSnSinkCurDayHighAggregatedInputPowerThe highest aggregated optical power of all the DWDM input
channels during the current calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.4.1.3 |
optIfOMSnSinkCurDayLowLaserTempThe lowest operating temperature of the laser during the
current calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.4.1.4 |
optIfOMSnSinkCurDayHighLaserTempThe highest operating temperature of the laser during the
current calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.4.1.5 |
optIfOMSnSinkPrevDayTableA table of OMSn sink performance monitoring information for
the previous calendar day. SEQUENCE OF OptIfOMSnSinkPrevDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.5 |
optIfOMSnSinkPrevDayEntryA conceptual row that contains OMSn sink performance
monitoring information of an interface for the previous
calendar day. OptIfOMSnSinkPrevDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.5.1 |
optIfOMSnSinkPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.5.1.1 |
optIfOMSnSinkPrevDayLastAggregatedInputPowerThe last aggregated optical power of all the DWDM input
channels during the previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.5.1.2 |
optIfOMSnSinkPrevDayLowAggregatedInputPowerThe lowest aggregated optical power of all the DWDM input
channels during the previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.5.1.3 |
optIfOMSnSinkPrevDayHighAggregatedInputPowerThe highest aggregated optical power of all the DWDM input
channels during the previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.5.1.4 |
optIfOMSnSinkPrevDayLastLaserTempThe last operating temperature of the laser during the
previous calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.5.1.5 |
optIfOMSnSinkPrevDayLowLaserTempThe lowest operating temperature of the laser during the
previous calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.5.1.6 |
optIfOMSnSinkPrevDayHighLaserTempThe highest operating temperature of the laser during the
previous calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.5.1.7 |
optIfOMSnSrcCurrentTableA table of OMSn source performance monitoring information for
the current 15 minute interval. SEQUENCE OF OptIfOMSnSrcCurrentEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6 |
optIfOMSnSrcCurrentEntryA conceptual row that contains OMSn source performance
monitoring information of an interface for the current
15 minute interval. OptIfOMSnSrcCurrentEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6.1 |
optIfOMSnSrcCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6.1.1 |
optIfOMSnSrcCurrentOutputPowerThe optical power monitored at the output.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6.1.2 |
optIfOMSnSrcCurrentLowOutputPowerThe lowest optical power monitored at the output during the
current interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6.1.3 |
optIfOMSnSrcCurrentHighOutputPowerThe highest optical power monitored at the output during the
current interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6.1.4 |
optIfOMSnSrcCurrentLowerOutputPowerThresholdThe lower limit threshold on output power. If
optIfOMSnSrcCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6.1.5 |
optIfOMSnSrcCurrentUpperOutputPowerThresholdThe upper limit threshold on output power. If
optIfOMSnSrcCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6.1.6 |
optIfOMSnSrcCurrentLaserTempThe operating temperature of the laser.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6.1.7 |
optIfOMSnSrcCurrentLowLaserTempThe lowest operating temperature of the laser during the
current interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6.1.8 |
optIfOMSnSrcCurrentHighLaserTempThe highest operating temperature of the laser during the
current interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6.1.9 |
optIfOMSnSrcCurrentLowerLaserTempThresholdThe lower limit threshold on laser temperature. If
optIfOMSnSrcCurrentLaserTemp drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6.1.10 |
optIfOMSnSrcCurrentUpperLaserTempThresholdThe upper limit threshold on laser temperature. If
optIfOMSnSrcCurrentLaserTemp reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.6.1.11 |
optIfOMSnSrcIntervalTableA table of historical OMSn source performance monitoring
information. SEQUENCE OF OptIfOMSnSrcIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.7 |
optIfOMSnSrcIntervalEntryA conceptual row that contains OMSn source performance
monitoring information of an interface during a particular
historical interval. OptIfOMSnSrcIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.7.1 |
optIfOMSnSrcIntervalNumberUniquely identifies the interval. IntervalNumber .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.7.1.1 |
optIfOMSnSrcIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.7.1.2 |
optIfOMSnSrcIntervalLastOutputPowerThe last optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.7.1.3 |
optIfOMSnSrcIntervalLowOutputPowerThe lowest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.7.1.4 |
optIfOMSnSrcIntervalHighOutputPowerThe highest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.7.1.5 |
optIfOMSnSrcIntervalLastLaserTempThe last operating temperature of the laser during the
interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.7.1.6 |
optIfOMSnSrcIntervalLowLaserTempThe lowest operating temperature of the laser during the
interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.7.1.7 |
optIfOMSnSrcIntervalHighLaserTempThe highest operating temperature of the laser during the
interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.7.1.8 |
optIfOMSnSrcCurDayTableA table of OMSn source performance monitoring information for
the current calendar day. SEQUENCE OF OptIfOMSnSrcCurDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.8 |
optIfOMSnSrcCurDayEntryA conceptual row that contains OMSn source performance
monitoring information of an interface for the current
calendar day. OptIfOMSnSrcCurDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.8.1 |
optIfOMSnSrcCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.8.1.1 |
optIfOMSnSrcCurDayLowOutputPowerThe lowest optical power monitored at the output during the
current calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.8.1.2 |
optIfOMSnSrcCurDayHighOutputPowerThe highest optical power monitored at the output during the
current calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.8.1.3 |
optIfOMSnSrcCurDayLowLaserTempThe lowest operating temperature of the laser during the
current calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.8.1.4 |
optIfOMSnSrcCurDayHighLaserTempThe highest operating temperature of the laser during the
current calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.8.1.5 |
optIfOMSnSrcPrevDayTableA table of OMSn source performance monitoring information for
the previous calendar day. SEQUENCE OF OptIfOMSnSrcPrevDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.9 |
optIfOMSnSrcPrevDayEntryA conceptual row that contains OMSn source performance
monitoring information of an interface for the previous
calendar day. OptIfOMSnSrcPrevDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.9.1 |
optIfOMSnSrcPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.9.1.1 |
optIfOMSnSrcPrevDayLastOutputPowerThe last optical power monitored at the output during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.9.1.2 |
optIfOMSnSrcPrevDayLowOutputPowerThe lowest optical power monitored at the output during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.9.1.3 |
optIfOMSnSrcPrevDayHighOutputPowerThe highest optical power monitored at the output during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.9.1.4 |
optIfOMSnSrcPrevDayLastLaserTempThe last operating temperature of the laser during the
previous calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.9.1.5 |
optIfOMSnSrcPrevDayLowLaserTempThe lowest operating temperature of the laser during the
previous calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.9.1.6 |
optIfOMSnSrcPrevDayHighLaserTempThe highest operating temperature of the laser during the
previous calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.3.9.1.7 |
optIfOCh OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4 |
optIfOTUk OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1 |
optIfOTUkConfigTableA table of OTUk configuration information. SEQUENCE OF OptIfOTUkConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1.1 |
optIfOTUkConfigEntryA conceptual row that contains OTUk configuration
information of an interface. OptIfOTUkConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1.1.1 |
optIfOTUkTraceIdentifierTransmittedThe trace identifier transmitted.rw SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1.1.1.1 |
optIfOTUkDAPIExpectedThe DAPI expected by the receiver.rw SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1.1.1.2 |
optIfOTUkSAPIExpectedThe SAPI expected by the receiver.rw SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1.1.1.3 |
optIfOTUkTraceIdentifierAcceptedThe actual trace identifier accepted.ro SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1.1.1.4 |
optIfOTUkAcTIStatusThe status of the accepted Trail Trace Identifier by the receiver.ro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1.1.1.5 |
optIfOTUkTIMDetModeIndicates the mode of the Trace Identifier Mismatch (TIM)
Detection function.rw Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1.1.1.6 |
optIfOTUkTIMActEnabledIndicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1.1.1.7 |
optIfOTUkDEGThrIndicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad if
the percentage of detected errored blocks in that second is
greater than or equal to DEGTHR.rw Integer32 UNITS "percentage" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1.1.1.8 |
optIfOTUkDEGMIndicates the threshold level for declaring a Degraded Signal defect
(dDEG). A dDEG shall be declared if DEGM consecutive bad PM Seconds
are detected.rw Integer32 .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1.1.1.9 |
optIfOTUkCurrentStatusIndicates the failure condition of the entity, if any.ro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.1.1.1.10 |
optIfODUkT OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2 |
optIfODUkTSinkConfigTableA table of ODUkT TCM Sink configuration information. SEQUENCE OF OptIfODUkTSinkConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.1 |
optIfODUkTSinkConfigEntryA conceptual row that contains ODUkT Sink configuration
information of an interface. OptIfODUkTSinkConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.1.1 |
optIfODUkTDAPIExpectedThe DAPI expected by the receiver.rw SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.1.1.2 |
optIfODUkTSAPIExpectedThe SAPI expected by the receiver.rw SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.1.1.3 |
optIfODUkTTraceIdentifierAcceptedThe actual trace identifier accepted.ro SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.1.1.4 |
optIfODUkTAcTIStatusThe status of the accepted Trail Trace Identifier by the receiver.ro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.1.1.5 |
optIfODUkTTIMDetModeIndicates the mode of the Trace Identifier Mismatch (TIM)
Detection function.rw Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.1.1.6 |
optIfODUkTDEGThrIndicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad if
the percentage of detected errored blocks in that second is
greater than or equal to DEGTHR.rw Integer32 UNITS "percentage" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.1.1.8 |
optIfODUkTDEGMIndicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if DEGM consecutive bad PM
Seconds are detected.rw Integer32 .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.1.1.9 |
optIfODUkTSinkModeControls the detection of the TCM sub-fields at the Sink:
If the value is TRANSPARENT, the TCM sub-fields were not inserted.
If the value is OPERATIONAL, then:
- Trail Trace Identifier is inserted in the TTI byte position
- Backward Defect Indication is inserted in the BDI bit position
- Bit Interleaved Parity (BIP-8) is inserted in the BIP8 byte
position
- Bits 6, 7 and 8 of byte BI shall be fixed to 000 (reserved)ro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.1.1.10 |
optIfODUkTSinkLockSignalAdminStateProvides the capability to provision the LOCK signal, which
is one of the ODUk maintenance signals, at the ODUKT sink. When
a Tandem Connection endpoint is set to admin state locked,
it inserts the ODUk-LCK signal in the sink direction.rw Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.1.1.11 |
optIfODUkTCurrentStatusIndicates the failure condition of the entity, if any.ro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.1.1.12 |
optIfODUkTSourceConfigTableA table of ODUkT TCM Source configuration information. SEQUENCE OF OptIfODUkTSourceConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.2 |
optIfODUkTSourceConfigEntryA conceptual row that contains ODUkT Source configuration
information of an interface. OptIfODUkTSourceConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.2.1 |
optIfODUkTTcmIdValue of the TCM level Unsigned32 .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.2.1.1 |
optIfODUkTTraceIdentifierTransmittedThe trace identifier transmitted.rw SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.2.1.2 |
optIfODUkTSourceModeControls the detection of the TCM sub-fields at the Source:
If the value is TRANSPARENT, all information shall be passed
through transparently, with the exception of the TCM ACT.
If the value is OPERATIONAL, then:
- Trail Trace Identifier is inserted in the TTI byte position
- Backward Defect Indication is inserted in the BDI bit position
- Bit Interleaved Parity (BIP-8) is inserted in the BIP8 byte
position
- Bits 6, 7 and 8 of byte BI shall be fixed to 000 (reserved)ro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.2.1.3 |
optIfODUkTSourceLockSignalAdminStateProvides the capability to provision the LOCK signal, which
is one of the ODUk maintenance signals, at the source.
When a Tandem Connection endpoint is set to admin state
locked, it inserts the ODUk-LCK signal in the source
direction.rw Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.2.2.1.4 |
optIfODUkP OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3 |
optIfODUkPConfigTableA table of ODUkP configuration information. SEQUENCE OF OptIfODUkPConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1 |
optIfODUkPConfigEntryA conceptual row that contains ODUkP configuration
information of an interface. OptIfODUkPConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1 |
optIfODUkPTraceIdentifierTransmittedThe trace identifier transmitted.rw SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.1 |
optIfODUkPDAPIExpectedThe DAPI expected by the receiver.rw SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.2 |
optIfODUkPSAPIExpectedThe SAPI expected by the receiver.rw SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.3 |
optIfODUkPTraceIdentifierAcceptedThe actual trace identifier accepted.ro SnmpAdminString .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.4 |
optIfODUkPAcTIStatusThe status of the accepted Trail Trace Identifier by the receiver.ro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.5 |
optIfODUkPTIMDetModeIndicates the mode of the Trace Identifier Mismatch (TIM)
Detection function.rw Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.6 |
optIfODUkPTIMActEnabledIndicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.7 |
optIfODUkPDEGThrIndicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad if
the percentage of detected errored blocks in that second is
greater than or equal to DEGTHR.rw Integer32 UNITS "percentage" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.8 |
optIfODUkPDEGMIndicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if DEGM consecutive bad PM
Seconds are detected.rw Integer32 .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.9 |
optIfODUkPCurrentStatusIndicates the failure condition of the entity, if any.ro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.10 |
optIfODUkPPayloadTypeTransmittedThe payload type signal transmitted.ro Unsigned32 .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.11 |
optIfODUkPPayloadTypeExpectedThe payload type signal expected by the receiver.ro Unsigned32 .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.12 |
optIfODUkPPayloadTypeAcceptedThe actual payload type signal accepted.ro Unsigned32 .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.13 |
optIfODUkPActiveAdaptFuncSourceWhen an ODUkP termination point supports multiple
adaptation functions, this object indicates the active
adaptation function at the interface port.rw Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.14 |
optIfODUkPActiveAdaptFuncSinkWhen an ODUkP termination point supports multiple
adaptation functions, this object indicates the active
adaptation function at the interface port.rw Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.3.1.1.15 |
optIfOChConfigTableA table of OCh configuration information. SEQUENCE OF OptIfOChConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.4 |
optIfOChConfigEntryA conceptual row that contains OCh configuration
information of an interface. OptIfOChConfigEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.4.1 |
optIfOChCurrentStatusIndicates the failure condition of the entity, if any.ro Enumeration .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.4.1.4 |
optIfOChSinkCurrentTableA table of OCh sink performance monitoring information for
the current 15 minute interval. SEQUENCE OF OptIfOChSinkCurrentEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.5 |
optIfOChSinkCurrentEntryA conceptual row that contains OCh sink performance
monitoring information for an interface for the current
15 minute interval. OptIfOChSinkCurrentEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.5.1 |
optIfOChSinkCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.5.1.1 |
optIfOChSinkCurrentInputPowerThe optical power monitored at the input.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.5.1.2 |
optIfOChSinkCurrentLowInputPowerThe lowest optical power monitored at the input during the
current interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.5.1.3 |
optIfOChSinkCurrentHighInputPowerThe highest optical power monitored at the input during the
current interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.5.1.4 |
optIfOChSinkCurrentLowerInputPowerThresholdThe lower limit threshold on input power. If
optIfOChSinkCurrentInputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.5.1.5 |
optIfOChSinkCurrentUpperInputPowerThresholdThe upper limit threshold on input power. If
optIfOChSinkCurrentInputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.5.1.6 |
optIfOChSinkIntervalTableA table of historical OCh sink performance monitoring
information. SEQUENCE OF OptIfOChSinkIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.6 |
optIfOChSinkIntervalEntryA conceptual row that contains OCh sink performance
monitoring information of an interface during a particular
historical interval. OptIfOChSinkIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.6.1 |
optIfOChSinkIntervalNumberUniquely identifies the interval. IntervalNumber .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.6.1.1 |
optIfOChSinkIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.6.1.2 |
optIfOChSinkIntervalLastInputPowerThe last optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.6.1.3 |
optIfOChSinkIntervalLowInputPowerThe lowest optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.6.1.4 |
optIfOChSinkIntervalHighInputPowerThe highest optical power monitored at the input during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.6.1.5 |
optIfOChSinkCurDayTableA table of OCh sink performance monitoring information for
the current calendar day. SEQUENCE OF OptIfOChSinkCurDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.7 |
optIfOChSinkCurDayEntryA conceptual row that contains OCh sink performance
monitoring information of an interface for the current
calendar day. OptIfOChSinkCurDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.7.1 |
optIfOChSinkCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.7.1.1 |
optIfOChSinkCurDayLowInputPowerThe lowest optical power monitored at the input during the
current calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.7.1.2 |
optIfOChSinkCurDayHighInputPowerThe highest optical power monitored at the input during the
current calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.7.1.3 |
optIfOChSinkPrevDayTableA table of OCh sink performance monitoring information for
the previous calendar day. SEQUENCE OF OptIfOChSinkPrevDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.8 |
optIfOChSinkPrevDayEntryA conceptual row that contains OCh sink performance
monitoring information of an interface for the previous
calendar day. OptIfOChSinkPrevDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.8.1 |
optIfOChSinkPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.8.1.1 |
optIfOChSinkPrevDayLastInputPowerThe last optical power monitored at the input during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.8.1.2 |
optIfOChSinkPrevDayLowInputPowerThe lowest optical power monitored at the input during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.8.1.3 |
optIfOChSinkPrevDayHighInputPowerThe highest optical power monitored at the input during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.8.1.4 |
optIfOChSrcCurrentTableA table of OCh source performance monitoring information for
the current 15 minute interval. SEQUENCE OF OptIfOChSrcCurrentEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9 |
optIfOChSrcCurrentEntryA conceptual row that contains OCh source performance
monitoring information of an interface for the current
15 minute interval. OptIfOChSrcCurrentEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9.1 |
optIfOChSrcCurrentSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9.1.1 |
optIfOChSrcCurrentOutputPowerThe optical power monitored at the output.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9.1.2 |
optIfOChSrcCurrentLowOutputPowerThe lowest optical power monitored at the output during the
current interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9.1.3 |
optIfOChSrcCurrentHighOutputPowerThe highest optical power monitored at the output during the
current interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9.1.4 |
optIfOChSrcCurrentLowerOutputPowerThresholdThe lower limit threshold on output power. If
optIfOChSrcCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9.1.5 |
optIfOChSrcCurrentUpperOutputPowerThresholdThe upper limit threshold on output power. If
optIfOChSrcCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9.1.6 |
optIfOChSrcCurrentLaserTempThe operating temperature of the laser.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9.1.7 |
optIfOChSrcCurrentLowLaserTempThe lowest operating temperature of the laser during the
current interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9.1.8 |
optIfOChSrcCurrentHighLaserTempThe highest operating temperature of the laser during the
current interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9.1.9 |
optIfOChSrcCurrentLowerLaserTempThresholdThe lower limit threshold on laser temperature. If
optIfOChSrcCurrentLaserTemp drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9.1.10 |
optIfOChSrcCurrentUpperLaserTempThresholdThe upper limit threshold on laser temperature. If
optIfOChSrcCurrentLaserTemp reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent.rw Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.9.1.11 |
optIfOChSrcIntervalTableA table of historical OCh source performance monitoring
information. SEQUENCE OF OptIfOChSrcIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.10 |
optIfOChSrcIntervalEntryA conceptual row that contains OCh source performance
monitoring information of an interface during a particular
historical interval. OptIfOChSrcIntervalEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.10.1 |
optIfOChSrcIntervalNumberUniquely identifies the interval. IntervalNumber .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.10.1.1 |
optIfOChSrcIntervalSuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.10.1.2 |
optIfOChSrcIntervalLastOutputPowerThe last optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.10.1.3 |
optIfOChSrcIntervalLowOutputPowerThe lowest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.10.1.4 |
optIfOChSrcIntervalHighOutputPowerThe highest optical power monitored at the output during the
interval.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.10.1.5 |
optIfOChSrcIntervalLastLaserTempThe last operating temperature of the laser during the
interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.10.1.6 |
optIfOChSrcIntervalLowLaserTempThe lowest operating temperature of the laser during the
interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.10.1.7 |
optIfOChSrcIntervalHighLaserTempThe highest operating temperature of the laser during the
interval.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.10.1.8 |
optIfOChSrcCurDayTableA table of OCh source performance monitoring information for
the current calendar day. SEQUENCE OF OptIfOChSrcCurDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.11 |
optIfOChSrcCurDayEntryA conceptual row that contains OCh source performance
monitoring information of an interface for the current
calendar day. OptIfOChSrcCurDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.11.1 |
optIfOChSrcCurDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.11.1.1 |
optIfOChSrcCurDayLowOutputPowerThe lowest optical power monitored at the output during the
current calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.11.1.2 |
optIfOChSrcCurDayHighOutputPowerThe highest optical power monitored at the output during the
current calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.11.1.3 |
optIfOChSrcCurDayLowLaserTempThe lowest operating temperature of the laser during the
current calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.11.1.4 |
optIfOChSrcCurDayHighLaserTempThe highest operating temperature of the laser during the
current calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.11.1.5 |
optIfOChSrcPrevDayTableA table of OCh source performance monitoring information for
the previous calendar day. SEQUENCE OF OptIfOChSrcPrevDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.12 |
optIfOChSrcPrevDayEntryA conceptual row that contains OCh source performance
monitoring information of an interface for the previous
calendar day. OptIfOChSrcPrevDayEntry .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.12.1 |
optIfOChSrcPrevDaySuspectedFlagIf true, the data in this entry may be unreliable.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.12.1.1 |
optIfOChSrcPrevDayLastOutputPowerThe last optical power monitored at the output during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.12.1.2 |
optIfOChSrcPrevDayLowOutputPowerThe lowest optical power monitored at the output during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.12.1.3 |
optIfOChSrcPrevDayHighOutputPowerThe highest optical power monitored at the output during the
previous calendar day.ro Integer32 UNITS "0.1 dbm" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.12.1.4 |
optIfOChSrcPrevDayLastLaserTempThe last operating temperature of the laser during the
previous calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.12.1.5 |
optIfOChSrcPrevDayLowLaserTempThe lowest operating temperature of the laser during the
previous calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.12.1.6 |
optIfOChSrcPrevDayHighLaserTempThe highest operating temperature of the laser during the
previous calendar day.ro Integer32 UNITS "degrees Celsius" .1.3.6.1.4.1.3727.20.20.3.1.10.1.1.4.12.1.7 |
optIfConfs OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.10.1.2 |
optIfGroups OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.10.1.2.1 |
optIfCompl OBJECT IDENTIFIER .1.3.6.1.4.1.3727.20.20.3.1.10.1.2.2 |