SNMP553S-MGMT-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for SNMP553S-MGMT-MIB.
81
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
81 total| Object Name |
|---|
snmp553s OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3 |
RFC1155-SMI Unknown .1.3.6.1.4.1.498.6.3 |
snmp553sAlarmData OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1 |
snmp553sNoResponseAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.1 |
snmp553sDiagRxErrAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.2 |
snmp553sPowerUpAlm OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.3 |
snmp553sNvRamCorrupt OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.4 |
snmp553sUnitFailure OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.5 |
snmp553sMbiLock OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.6 |
snmp553sLocalPwrFail OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.7 |
snmp553sTimingLoss OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.8 |
snmp553sStatusChange OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.9 |
snmp553sUnsoTest OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.10 |
snmp553sLossOfSignal OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.11 |
snmp553sLossOfFrame OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.12 |
snmp553sAis OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.13 |
snmp553sReceivedYellow OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.14 |
snmp553sUnavailSignalState OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.15 |
snmp553sExcessiveZeros OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.16 |
snmp553sLowAverageDensity OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.17 |
snmp553sControlledSlips OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.18 |
snmp553sBipolarViolations OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.19 |
snmp553sCrcErrors OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.1.20 |
snmp553sMIBversionIdentifies the version of the MIB. The format of the version
is x.yzT, where 'x' identifies the major revision number, 'y'
identifies the minor revision number, 'z' identifies the
typographical revision, and T identifies the test revision.
Acceptable values for the individual revision components are
as follows:
x: 1 - 9
y: 0 - 9
z: 0 - 9
T: A - Z
Upon formal release, no designation for the test revision will
be present.ro DisplayString .1.3.6.1.4.1.498.6.3.2 |
snmp553sMaintenanceTableThe SNMP553S Maintenance table. This table augments the
Gdc Dsx1 maintenance table, providing maintenance functions
specific to the 553S. SEQUENCE OF Snmp553sMaintenanceEntry .1.3.6.1.4.1.498.6.3.3 |
snmp553sMaintenanceEntryThe SNMP553S Maintenance table entry. Snmp553sMaintenanceEntry .1.3.6.1.4.1.498.6.3.3.1 |
snmp553sMaintenanceIndexThe index value which uniquely identifies the 553S to which
this entry is applicable. This has the form of a SCinstance
which defines the slot, line, and drop of the 553S with
sub-identifier value set to unit(1).ro SCinstance .1.3.6.1.4.1.498.6.3.3.1.1 |
snmp553sCascadePresentIdentifies whether or not the cascade interface cards
are installed.ro Enumeration .1.3.6.1.4.1.498.6.3.3.1.2 |
snmp553sExtModemPresentIdentifies whether or not an external modem is attached to the
modem ppp interface.ro Enumeration .1.3.6.1.4.1.498.6.3.3.1.3 |
snmp553sUnitTypeIdentifies the GDC Netcon position of the unit. The value master(1)
indicates that the NMS unit is configured as a Netcon Master, whereby
diagnostic management information is received through a local Netcon
port. The value remote(2) indicates that the unit is configured as a
Netcon remote, whereby diagnostic management information is received
through it's network interface or through an out of band (modem) link.ro Enumeration .1.3.6.1.4.1.498.6.3.3.1.4 |
snmp553sManagementSourceIdentifies the management data source. The value modemSnmp(1)
indicates that the management source is SNMP via an dial-up
ppp link. The value secondaryChannel(2)indicates that the
management source is via an inband Diagnostics communications
channel. The value fdl(3) indicates that the management source
is via the out-of-band facilities data link. The value daisyChain(4)
indicates that the management source via the NETCON master-in port.
The value bus485(5) indicates that the management source is via
the shelf commander in the Universal Systems Shelf. The value
localSnmp(6) indicates that the management source is SNMP via
a locap ppp link.ro Enumeration .1.3.6.1.4.1.498.6.3.3.1.5 |
snmp553sProductTypeIndicates the product type of the unit.ro Enumeration .1.3.6.1.4.1.498.6.3.3.1.6 |
snmp553sLedStatusReturns a bitwise snapshot of the front panel LED state.
Octet 1 bit 7 - not used
bit 6 - ON
bit 5 - DSX1
bit 4 - NMSRSP (nms553 products) or MGMT DATA (553s products)
bit 3 - NMSDAT (nms553 products) or MGMT RESP (553s products)
bit 2 - ER
bit 1 - DSX OOF
bit 0 - DSX LOS
Octet 2 bit 7 - not used
bit 6 - NET OOF
bit 5 - NET LOS
bit 4 - NET BPV
bit 3 - NET AIS
bit 2 - TM/ALM
bit 1 - LBK
bit 0 - future use
Octet 3 bit 7 - not used
bit 6 - CHA SD ==> 553D1 and 553D3 only
bit 5 - CHA RD ==> ''
bit 4 - CHB SD ==> 553D3 only
bit 3 - CHB RD ==> ''
bit 2 - CHC SD ==> ''
bit 1 - CHC RD ==> ''
bit 0 - future use.
Note: The value returned for all Channel SD and RD leds
is unreliable when the unit is performing DSU level
self-tests and loopbacks.ro OCTET STRING .1.3.6.1.4.1.498.6.3.3.1.7 |
snmp553sUnitSerialNumberThis object returns the GDC 8-byte unit serial number in
16 nibbles. Each device has a unique serial number of the
form:
00xx0pmmddyy####
where
xx = Product type:
26 - NMS553C products
27 - NMS553D products
43 - 553SD products
44 - 553SC products
p = Source of Software
1 - Software programmed by manufacturing
' 9 - Software programmed by engineering
mm = Month of manufacture
dd = Day of manufacture
yy = Year of manufacture
#### = Daily manufacturing sequence number.ro OCTET STRING .1.3.6.1.4.1.498.6.3.3.1.8 |
snmp553sSaveAllConfigCommands unit to save 553S CSU and DSU configuration variables in
non-volatile memory and configure the unit as defined.
When CSU and DSU configuration variables are modified they are not
updated in the 553S hardware until a SaveConfig command
is received via this object.
When this value is set to SaveConfig(2) the current 553S
csu and dsu configuration variables become active within the unit.
The value of normal(1) will be returned when the
initialization is complete. The value normal(1) cannot be
set by management.rw Enumeration .1.3.6.1.4.1.498.6.3.3.1.9 |
snmp553sUnitConfigTableThe SNMP553S Unit Configuration table. This table augments the
GDC dsx1 configuration table, providing additional unit level
configuration specific to the 553s. SEQUENCE OF Snmp553sUnitConfigEntry .1.3.6.1.4.1.498.6.3.4 |
snmp553sUnitConfigEntryThe SNMP553S Unit Configuration table entry. Snmp553sUnitConfigEntry .1.3.6.1.4.1.498.6.3.4.1 |
snmp553sUnitConfigIndexThe index value which uniquely identifies the SNMP553S to which
this entry is applicable. This has the form of a SCinstance
which defines the slot, line, and drop of 553S with a
sub-identifier value of unit(1).ro SCinstance .1.3.6.1.4.1.498.6.3.4.1.1 |
snmp553sSaveCsuConfigCommands unit to save 553S CSU configuration variables in
non-volatile memory and configure the unit as defined.
When CSU configuration variables are modified they are not
updated in the 553S hardware until a SaveConfig command
is received via this object.
When this value is set to SaveConfig(2) the current 553S
csu configuration variables become active within the unit.
The value of normal(1) will be returned when the
initialization is complete. The value normal(1) cannot be
set by management.rw Enumeration .1.3.6.1.4.1.498.6.3.4.1.2 |
snmp553sShelfCommanderIdentifies the 553s unit as the shelf commander in a
Datacomm 4-pak or Universal Systems Shelf. When configured
as the shelf commander, the unit passes the SNMP diagnostics
information using the Netcon protocol to other units in the
shelf via the RS485 bus.rw Enumeration .1.3.6.1.4.1.498.6.3.4.1.3 |
snmp553sForceFakeMasterForces the 553s as a Netcon Master unit. This option
allows a unit without a master-in connection to a netcon
controller behave as a Netcon master for configuring
diagnostics on downstream (remote) units.rw Enumeration .1.3.6.1.4.1.498.6.3.4.1.4 |
snmp553sDaisyChainBpsIndicates the data rate at which a remote unit will propogate
NMS commands out of a daisy chain connection. None(1)
indicates that no outbound daisy chain exists on this unit.rw Enumeration .1.3.6.1.4.1.498.6.3.4.1.5 |
snmp553sChannelConfigTableThe SNMP553S Channel Configuration table. This table augments the
GDC dsu Channel Configuration table, providing additional unit level
configuration specific to the 553s. SEQUENCE OF Snmp553sChannelConfigEntry .1.3.6.1.4.1.498.6.3.5 |
snmp553sChannelConfigEntryThe SNMP553S Channel Configuration table entry. Snmp553sChannelConfigEntry .1.3.6.1.4.1.498.6.3.5.1 |
snmp553sChannelConfigIndexThe index value which uniquely identifies the 553S to which
this entry is applicable. This has the form of a SCinstance
which defines the slot, line, drop, and channel of the 553S.ro SCinstance .1.3.6.1.4.1.498.6.3.5.1.1 |
snmp553sDCCCompatibilityModeIdentifies the 553S DCC mode. The value nms553(1) indicates
that the inband link is communicating with an NMS553 remote.
The value nms510(2) indicates that the inband link is
communicating with an NMS510 remote. This object works with
with snmp553sUnitType; it can never be set to nms510(2) unless
snmp553sUnitType is master(1).
The value other(3) indicates that the compatibility mode has
been specified elsewhere. This value can never be set by
management operation.rw Enumeration .1.3.6.1.4.1.498.6.3.5.1.2 |
snmp553sSaveDsuConfigCommands unit to save 553S channel configuration variables in
non-volatile memory and configure the unit as defined.
When DSU configuration variables are modified they are not
updated in the 553S hardware until a SaveConfig command
is received via this object.
When this value is set to SaveConfig(2) the current 553S
dsu configuration variables become active within the unit.
The value of normal(1) will be returned when the
initialization is complete. The value normal(1) cannot be
set by management.rw Enumeration .1.3.6.1.4.1.498.6.3.5.1.3 |
snmp553sDiagTableThe 553S Diagnostics table. This table augments the
GDC dsx1 Diagnostics table and the GDC dsu diagnostics
table. SEQUENCE OF Snmp553sDiagEntry .1.3.6.1.4.1.498.6.3.6 |
snmp553sDiagEntryThe SNMP553S Diagnostics table entry. Snmp553sDiagEntry .1.3.6.1.4.1.498.6.3.6.1 |
snmp553sDiagIndexThe index value which uniquely identifies the 553S to which
this entry is applicable. This has the form of a SCinstance
which defines the slot, line, and drop of the 553S with a
sub-identifier value of unit(1).ro SCinstance .1.3.6.1.4.1.498.6.3.6.1.1 |
snmp553sDiagTestDurationSelects the duration to run a diagnostic test, in time.
The value(1) noLimit indicates that the test should run
until explicitly terminated. The default value is noLimit(1).
This object is used for all tests defined in both the GDC
dsx1 mib and the GDC dsu mib.rw Enumeration .1.3.6.1.4.1.498.6.3.6.1.2 |
snmp553sDiagProgPatternThe 16 bit user programmable test pattern. This object
works with the gdcDsx1SendCode object in that when gdcDsx1SendCode
is set to sendProgPattern(4), the the value of this object is
used as the 16 bit user programmable test pattern.
This object is used for all tests defined in both the GDC
dsx1 mib.rw INTEGER (0..'ffff'h) .1.3.6.1.4.1.498.6.3.6.1.3 |
snmp553sAlarmHistoryTableThe snmp553sAlarmHistoryTable contains entries that report the
history of all supported alarms. The history consists of the
the number of times the alarm has occurred since last history
reset, the time of the first alarm occurence (hours,minutes,
seconds,day,month,year), and the time of the last alarm occurrence
(hours,minutes,seconds,day,month,year).
The structure of the table is such that alarm status is
supported on a unit or interface basis, and then on an alarm
type basis within the interface. For simplicity sake and to
support the reporting of status of all alarms, a unit is
treated as an interface 1 in this table. SEQUENCE OF Snmp553sAlarmHistoryEntry .1.3.6.1.4.1.498.6.3.7 |
snmp553sAlarmHistoryEntryAn entry in the GDC SNMP553S Alarm History table. Snmp553sAlarmHistoryEntry .1.3.6.1.4.1.498.6.3.7.1 |
snmp553sAlarmHistoryIndexThe index value which uniquely identifies the interface to
which this entry is applicable.ro SCinstance .1.3.6.1.4.1.498.6.3.7.1.1 |
snmp553sAlarmHistoryIdentifierThe unique alarm identifier assigned to this alarm type.
The format of this identifier is an OBJECT IDENTIFIER that has
the following format: {iso(1) org(3) dod(6) internet(1)
private(4) enterprises(1) gdc(498) xxx(x) alarm(z) yyy(y)
where xxx(x) is the administratively assigned family object
identifier (z) is the object identifier for alarms in the family
defined MIB and yyy(y) is the administratively assigned alarm
type identifier for this alarm.ro OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.3.7.1.2 |
snmp553sAlarmCountThe number of occurrences of this alarm. This objects value
is incremented once for each time that the alarm occurs. This
count is incremented regardless of whether or not the alarm
is masked or is not reporteded because of the threshold
configuration.ro Gauge .1.3.6.1.4.1.498.6.3.7.1.3 |
snmp553sAlarmFirstOccurrenceHoursThe hour (0-23) the alarm first occurred.ro INTEGER .1.3.6.1.4.1.498.6.3.7.1.4 |
snmp553sAlarmFirstOccurrenceMinutesThe minute (0-59) the alarm first occurred.ro INTEGER .1.3.6.1.4.1.498.6.3.7.1.5 |
snmp553sAlarmFirstOccurrenceSecondsThe second (0-59) the alarm first occurred.ro INTEGER .1.3.6.1.4.1.498.6.3.7.1.6 |
snmp553sAlarmFirstOccurrenceMonthThe month (1-12) the alarm first occurred.ro INTEGER .1.3.6.1.4.1.498.6.3.7.1.7 |
snmp553sAlarmFirstOccurrenceDayThe day (1-31) the alarm first occurred.ro INTEGER .1.3.6.1.4.1.498.6.3.7.1.8 |
snmp553sAlarmFirstOccurrenceYearThe year (0-99) the alarm first occurred.ro INTEGER .1.3.6.1.4.1.498.6.3.7.1.9 |
snmp553sAlarmLastOccurrenceHoursThe hour (0-23) the alarm last occurred.ro INTEGER .1.3.6.1.4.1.498.6.3.7.1.10 |
snmp553sAlarmLastOccurrenceMinutesThe minute (0-59) the alarm last occurred.ro INTEGER .1.3.6.1.4.1.498.6.3.7.1.11 |
snmp553sAlarmLastOccurrenceSecondsThe second (0-59) the alarm last occurred.ro INTEGER .1.3.6.1.4.1.498.6.3.7.1.12 |
snmp553sAlarmLastOccurrenceMonthThe month (1-12) the alarm last occurred.ro INTEGER .1.3.6.1.4.1.498.6.3.7.1.13 |
snmp553sAlarmLastOccurrenceDayThe day (1-31) the alarm last occurred.ro INTEGER .1.3.6.1.4.1.498.6.3.7.1.14 |
snmp553sAlarmLastOccurrenceYearThe year (0-99) the alarm last occurred.ro INTEGER .1.3.6.1.4.1.498.6.3.7.1.15 |
snmp553sAlarmMaintenanceTableThe snmp553sAlarmMaintenanceTable contains entries that configure
the real time clock and that clear the alarm history table. SEQUENCE OF Snmp553sAlarmMaintenanceEntry .1.3.6.1.4.1.498.6.3.8 |
snmp553sAlarmMaintenanceEntryAn entry in the GDC snmp553s Alarm Maintenance Table. Snmp553sAlarmMaintenanceEntry .1.3.6.1.4.1.498.6.3.8.1 |
snmp553sAlarmMaintenanceIndexThe index value which uniquely identifies the interface to
which this entry is applicable.ro SCinstance .1.3.6.1.4.1.498.6.3.8.1.1 |
snmp553sClearAlarmHistorySupports the action of clearing the alarm history table.
When this object is set to clear(1), then the unit clears
the alarm history table. The value of norm(2) will be
returned when the clear is complete.
The value of norm(2) can not be set by management.rw Enumeration .1.3.6.1.4.1.498.6.3.8.1.2 |
snmp553sRTCHoursThe hour of day (0-23) to be set or read.rw INTEGER .1.3.6.1.4.1.498.6.3.8.1.3 |
snmp553sRTCMinutesThe minute of the hour (0-59) to be set or read.rw INTEGER .1.3.6.1.4.1.498.6.3.8.1.4 |
snmp553sRTCSecondsThe second of the minute (0-59) to be set or read.rw INTEGER .1.3.6.1.4.1.498.6.3.8.1.5 |
snmp553sRTCMonthThe month of the year (1-12) to be set or read.rw INTEGER .1.3.6.1.4.1.498.6.3.8.1.6 |
snmp553sRTCDayThe day of the month (1-31) to be set or read.rw INTEGER .1.3.6.1.4.1.498.6.3.8.1.7 |
snmp553sRTCYearThe year (0-99) to be set or read.rw INTEGER .1.3.6.1.4.1.498.6.3.8.1.8 |
snmp553sTimeOfLastAlarmClearReturns the time (hours,minutes,seconds,month,day,year) of
the last alarm clear command sent to the unit.
Octet 1 - Hour of last alarm clear (0-23)
Octet 2 - Minute of last alarm clear (0-59)
Octet 3 - Second of last alarm clear (0-59)
Octet 4 - Month of last alarm clear (1-12)
Octet 5 - Day of last alarm clear (1-31)
Octet 6 - Year of last alarm clear (0-99).ro OCTET STRING .1.3.6.1.4.1.498.6.3.8.1.9 |
snmp553sc OBJECT IDENTIFIER .1.3.6.1.4.1.498.6.4 |