SITE-MONITORING-MIB
AI MIB Summary
The SITE-MONITORING-MIB structures SNMP OIDs to categorize and organize management data for Alpha Innovations hardware based on specific design center architectures. This module facilitates the monitoring of site-specific operational metrics and device states within the vendor's proprietary network infrastructure.
Alpha Innovations SNMP corporate naming convention Organises the SNMP OIDs according to the design centres that generate the different MIBs
Main OID:
siteMonitoringMIB.1.3.6.1.4.1.26854.1.1
552
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
552 total| Object Name |
|---|
atsa OBJECT IDENTIFIER .1.3.6.1.4.1.26854 |
atsaCorporate OBJECT IDENTIFIER .1.3.6.1.4.1.26854.1 |
siteMonitoringMIBAlpha Innovations SNMP corporate naming convention Organises the SNMP OIDs according to the design centres that generate the different MIBs MODULE-IDENTITY .1.3.6.1.4.1.26854.1.1 |
atsaUs OBJECT IDENTIFIER .1.3.6.1.4.1.26854.2 |
atsaEu OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3 |
atsaEuDevices OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.1 |
siteMonitoring OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2 |
siteV1 OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1 |
siteV1GlobalStatusA textual string (alarms, normal or unknown) containing the status of the Sitero DisplayString .1.3.6.1.4.1.26854.3.2.1.1 |
siteV1GlobalAlarmSeverityTypeThe alarm severity type (critical, major, minor, warning, none, disabled) of the Sitero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.2 |
siteV1GlobalAlarmSeverityLevelThe alarm severity level (0-9) of the Sitero Integer32 .1.3.6.1.4.1.26854.3.2.1.3 |
siteV1GlobalAlarmSeverityTypeIntThe alarm severity type as integer (critical=4, major=3, minor=2, warning=1, none=0) of the Sitero Integer32 .1.3.6.1.4.1.26854.3.2.1.4 |
siteV1Description OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.10 |
siteV1DescriptionNumberThe number of entries in the Site Description tablero Integer32 .1.3.6.1.4.1.26854.3.2.1.10.1 |
siteV1DescriptionTableThe Description table of the Site SEQUENCE OF SiteV1DescriptionEntry .1.3.6.1.4.1.26854.3.2.1.10.2 |
siteV1DescriptionEntryA Description entry SiteV1DescriptionEntry .1.3.6.1.4.1.26854.3.2.1.10.2.1 |
siteV1DescriptionIndexDescription Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.10.2.1.1 |
siteV1DescriptionNameDescription Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.2.1.2 |
siteV1DescriptionValueDescription Valuerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.2.1.3 |
siteV1DescriptionEntryStatusThe status of this table entryrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.2.1.4 |
siteV1DescriptionList OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.10.3 |
siteV1DescDescriptionSiteNumberThe identification number of the siterw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.1 |
siteV1DescDescriptionSiteNameThe name of the siterw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.2 |
siteV1DescDescriptionShortDescriptionA short description of the siterw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.3 |
siteV1DescDescriptionInfoSome more information about the siterw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.4 |
siteV1DescDescriptionDescriptionA free text zone to write a system descriptionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.5 |
siteV1DescDescriptionReferenceA free text zone to write the customer reference of the systemrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.6 |
siteV1DescDescriptionContactNameContact Namerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.7 |
siteV1DescDescriptionPhoneNumberPhone Numberrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.8 |
siteV1DescDescriptionStreetStreet part of the site addressrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.11 |
siteV1DescDescriptionCityCity part of the site addressrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.12 |
siteV1DescDescriptionProvinceProvince part of the site addressrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.13 |
siteV1DescDescriptionPostalCodePostal Code part of the site addressrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.14 |
siteV1DescDescriptionRegionRegion part of the site addressrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.15 |
siteV1DescDescriptionCountryCountry part of the site addressrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.16 |
siteV1DescDescriptionGroup1Group Level 1 (For Armada Clustering)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.21 |
siteV1DescDescriptionGroup2Group Level 2 (For Armada Clustering)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.22 |
siteV1DescDescriptionGroup3Group Level 3 (For Armada Clustering)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.23 |
siteV1DescDescriptionGroup4Group Level 4 (For Armada Clustering)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.24 |
siteV1DescDescriptionGroup5Group Level 5 (For Armada Clustering)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.25 |
siteV1DescDescriptionLatitudeThe latitude of the siterw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.31 |
siteV1DescDescriptionLongitudeThe longitude of the siterw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.32 |
siteV1DescDescriptionAltitudeThe altitude of the siterw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.33 |
siteV1DescControllerSoftwareRevisionThe software revision of Comp@s (read only)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.91 |
siteV1DescControllerOperatingSystemRevisionThe operating system of Comp@s (read only)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.92 |
siteV1DescControllerCPUInformation about the CPUro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.93 |
siteV1DescControllerCardInformation about the hardware system containing Compasro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.94 |
siteV1DescControllerStarterVersionInformation about the starter component of Compasro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.100 |
siteV1DescControllerFactoryCompasVersionInformation about the revision of Compas in Factory folderro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.105 |
siteV1DescControllerUserCompasVersionInformation about the revision of Compas in user folderro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.106 |
siteV1DescControllerFactoryFTPServerVersionInformation about the revision of Ftp Server in Factory folderro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.110 |
siteV1DescControllerUserFTPServerVersionInformation about the revision of Ftp Server in Factory folderro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.10.3.111 |
siteV1Alarm OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.11 |
siteV1AlarmNumberThe number of entries in the Site Alarm tablero Integer32 .1.3.6.1.4.1.26854.3.2.1.11.1 |
siteV1AlarmTableThe table of Alarm entries SEQUENCE OF SiteV1AlarmEntry .1.3.6.1.4.1.26854.3.2.1.11.2 |
siteV1AlarmEntryAn alarm entry SiteV1AlarmEntry .1.3.6.1.4.1.26854.3.2.1.11.2.1 |
siteV1AlarmIndexAlarm Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.11.2.1.1 |
siteV1AlarmNameAlarm Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.11.2.1.2 |
siteV1AlarmActiveIs the Alarm active ? 'true' for active, 'false' for not-activero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.11.2.1.3 |
siteV1AlarmSeverityTypeThe alarm severity type (major, minor, warning, none, disabled) of this alarm entryrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.11.2.1.4 |
siteV1AlarmSeverityLevelThe alarm severity level (0-9) of this alarm entryrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.11.2.1.5 |
siteV1AlarmStartTimeThe last start time of this alarm entry (null if never active)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.11.2.1.6 |
siteV1AlarmStopTimeThe last stop time of this alarm entry (null if alarm active)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.11.2.1.7 |
siteV1AlarmEntryStatusThe status of this table entry - not used, only for MIB compliancerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.11.2.1.8 |
siteV1AlarmSummarySummary bit vector with all the alarms state of the Site. A '1' means alarm active, '0' means not active. Unimplemented alarms are always '0'.ro Bits .1.3.6.1.4.1.26854.3.2.1.11.3 |
siteV1Event OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.12 |
siteV1EventNumberThe number of entries in the Event Table related to the Sitero Integer32 .1.3.6.1.4.1.26854.3.2.1.12.1 |
siteV1EventTableThe Event table related to the Site SEQUENCE OF SiteV1EventEntry .1.3.6.1.4.1.26854.3.2.1.12.2 |
siteV1EventEntry. SiteV1EventEntry .1.3.6.1.4.1.26854.3.2.1.12.2.1 |
siteV1EventIndexEvent Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.12.2.1.1 |
siteV1EventIdEvent Indexro Unsigned32 .1.3.6.1.4.1.26854.3.2.1.12.2.1.2 |
siteV1EventNameEvent Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.12.2.1.3 |
siteV1EventDateTimeThe date and time of the eventro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.12.2.1.4 |
siteV1EventSeverityTypeThe event severity type ('major', 'minor', 'warning' or 'none')ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.12.2.1.5 |
siteV1EventSeverityLevelThe event severity level (0-9)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.12.2.1.6 |
siteV1EventEntryStatusThe status of this table entryrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.12.2.1.7 |
siteV1Data OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.13 |
siteV1DataNumberThe number of entries in the Data Table related to the Sitero Integer32 .1.3.6.1.4.1.26854.3.2.1.13.1 |
siteV1DataTableThe table of Data entries SEQUENCE OF SiteV1DataEntry .1.3.6.1.4.1.26854.3.2.1.13.2 |
siteV1DataEntryA data entry SiteV1DataEntry .1.3.6.1.4.1.26854.3.2.1.13.2.1 |
siteV1DataIndexThe data index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.13.2.1.1 |
siteV1DataNameThe data namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.13.2.1.2 |
siteV1DataValueThe data valuero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.13.2.1.3 |
siteV1DataEntryStatusThe status of this table entry - not used, only present for compliancerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.13.2.1.4 |
siteV1DataList OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.13.3 |
siteV1DataNetworkCurrentIPAddressThis is the actual IP address of the Comp@s platform. If the Ethernet cable is not correctly connected, the address will be 0.0.0.0.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.13.3.1 |
siteV1DataNetworkCurrentIPMaskThis is the actual IP address of the Comp@s platform. If the Ethernet cable is not correctly connected, the address will be 0.0.0.0.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.13.3.2 |
siteV1DataNetworkCurrentMACAddressThis is the MAC address of IP interface.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.13.3.3 |
siteV1DataControllerLicensedOptionsThis is the options of the actual license.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.13.3.11 |
siteV1DataTimeDateAndTimeLocalThis is the local time of the monitoring.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.13.3.21 |
siteV1DataTimeDateAndTimeUTCThis is the UTC time of the monitoring.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.13.3.22 |
siteV1DataControllerMonitoringMemoryUsedThis is actual amount of RAM memory used by the application.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.13.3.31 |
siteV1DataControllerCPUPercentageUsageThis is actual percentage of CPU usedro Integer32 .1.3.6.1.4.1.26854.3.2.1.13.3.32 |
siteV1DataControllerFreeFlashMemorySpaceThis is free flash memory available on the Comp@s card, in Megabytesro Integer32 .1.3.6.1.4.1.26854.3.2.1.13.3.33 |
siteV1DataControllerFTPServerStatusStatus of the FTP Server. Compatible only with version >= 2.26.X.X. The configuration is available at controller -> FTP Server page.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.13.3.35 |
siteV1DataDataRecordsTotalFifoSizeOfSecondRecordsNAro Integer32 .1.3.6.1.4.1.26854.3.2.1.13.3.41 |
siteV1DataDataRecordsTotalFifoSizeOfMinuteRecordsNAro Integer32 .1.3.6.1.4.1.26854.3.2.1.13.3.42 |
siteV1DataDataRecordsTotalFifoSizeOfHourRecordsNAro Integer32 .1.3.6.1.4.1.26854.3.2.1.13.3.43 |
siteV1DataDataRecordsTotalFifoSizeOfDayRecordsNAro Integer32 .1.3.6.1.4.1.26854.3.2.1.13.3.44 |
siteV1DataInventoryCANBusNodeIDsThe coma separated list of the node ids present on the CAN bus.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.13.3.51 |
siteV1DataCloudLinkCloudLinkStateCloud Link Statero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.13.3.166 |
siteV1Config OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.15 |
siteV1ConfigNumberThe number of entries in the Config table related to the Sitero Integer32 .1.3.6.1.4.1.26854.3.2.1.15.1 |
siteV1ConfigTableThe table of Config entries related to the Site SEQUENCE OF SiteV1ConfigEntry .1.3.6.1.4.1.26854.3.2.1.15.2 |
siteV1ConfigEntryA Config entry SiteV1ConfigEntry .1.3.6.1.4.1.26854.3.2.1.15.2.1 |
siteV1ConfigIndexThe Config entry Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.15.2.1.1 |
siteV1ConfigNameThe Config entry namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.2.1.2 |
siteV1ConfigValueThe Config entry valuerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.2.1.3 |
siteV1ConfigEntryStatusThe status of this table entry - not used, only for compliancerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.2.1.4 |
siteV1ConfigList OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.15.3 |
siteV1CfgNetworkDHCPEnabledThe monitoring will try to get an IP with the DHCP protocol if this parameter is set to True. By default, this parameter is set to False.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.1 |
siteV1CfgNetworkIPAddressIfStaticThe static IP address of the monitoring. This configuration parameter is not used if the DHCP is enabled. The default IP is 192.168.45.2.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.2 |
siteV1CfgNetworkSubnetMaskIfStaticThe static Subnet Mask of the monitoring. This configuration parameter is not used if the DHCP is enabled. The default mask is 255.255.255.0.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.3 |
siteV1CfgNetworkDefaultGatewayIfStaticThe static Default Gateway of the monitoring. This configuration parameter is not used if DHCP is enabled. This is only useful if the monitoring have to use a gateway, this is generally not necessary. The default gateway is 192.168.45.1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.4 |
siteV1CfgNetworkDNSIfStaticThe static DNS of the monitoring. This configuration parameter is used to resolve URI and server name. This is not necessary if you are only IP address as target server. The default DNS server is 192.168.45.1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.5 |
siteV1CfgNetworkMaxTransmissionUnitSpecifies the TCP/IP MTU for the network interfacerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.8 |
siteV1CfgTimeSNTPTimeServerThe address of the server acting as SNTP timer server. If this server is not valid, the monitoring cannot update automatically his time. You can use several time server by usin a coma separator without space.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.11 |
siteV1CfgTimeTimeZoneNameThe Time Zone of the siterw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.14 |
siteV1CfgTimeSNTPTimeRefreshSet the time between synchronisation with the SNTP server (max 1000 hours, by default 178)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.15 |
siteV1CfgTimeSNTPTimeRecoveryRefreshSet the time to wait before retry if a synchronisation fail (max 1000 hours, by default 24)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.16 |
siteV1CfgWebServerWebServerSecurityEnabledThis is a True/False parameter used to activate or deactivate the access control to the web server.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.22 |
siteV1CfgWebServerWebServerPortThis is an unsigned integer parameter used to configure the port at which the web server is accessible. By default, the port is 80. If you change this port, you must be sure that the traffic is allowed by your switches and routers on this port.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.23 |
siteV1CfgWebServerWebAuthenticationMethodThe web access security can be managed with 3 authentication methods: Basic Access, Digest Access or Basic with Radius.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.24 |
siteV1CfgWebServerHttpsWebServerPortThis is a port number to activate or deactivate the https web server - 0 or 443 by defaultrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.26 |
siteV1CfgWebServerDefaultPageThe default page displayed on logon (dashboard, site, summary, alarm_event, ...)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.31 |
siteV1CfgXMLXMLEventPostingActivatedThis is a True/False parameter used to activate or deactivate the XML event posting.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.41 |
siteV1CfgXMLXMLEventPostingRefreshTimeThe minimal time in second between to calculation of the XML events to send. By default, this is done every two seconds.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.42 |
siteV1CfgXMLXMLEventPostingTimeoutThe timeout in millisecond when trying to post XML data to a Web Server.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.43 |
siteV1CfgXMLXMLEventPostingToSecOnlyIfPrimFailIf this parameter is set to true, the events will be sent to secondary only if primary server is not available. If this parameter is set to false, all the events will be sent to primary and secondary serverrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.45 |
siteV1CfgXMLXMLTablesToPostOnXMLEventThe list of the tables to send when an event is generated. (description,alarm,data,config,control). This allows to have armada database updated on event.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.46 |
siteV1CfgXMLXMLHeartbeatTimeThis is the time between 2 XML Post of heartbeat. If set to 0, no heartbeat.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.51 |
siteV1CfgSNMPSNMPActivatedThis is a True/False parameter used to activate or deactivate the SNMP agent.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.61 |
siteV1CfgSNMPSNMPTrapVersionTraps/Notification can be sent with SNMP V1, V2c or V3 format.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.63 |
siteV1CfgSNMPSNMPGETMinSecurityLevel4 choices are available: No Authentication, V1 Community, V2c Community or V3.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.64 |
siteV1CfgSNMPSNMPSETMinSecurityLevel4 choices are available: No Authentication, V1 Community, V2c Community or V3.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.65 |
siteV1CfgSNMPSNMPV3AuthAlgorithm3 choices are available: MD5, SHA, Anyrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.66 |
siteV1CfgSNMPSNMPV3PrivacyAlgorithm3 choices are available: DES, AES, 3DESrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.67 |
siteV1CfgSNMPSNMPV3PrivacyPasswordThe global SNMP V3 Encryption Password. This one is common for all the users to avoid complexityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.68 |
siteV1CfgSNMPSNMPV3EngineIDThe SNMP V3 Local Engine ID stringrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.69 |
siteV1CfgSNMPSNMPV3TrapAuthAlgorithm2 choices are available: MD5, SHArw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.72 |
siteV1CfgSNMPSNMPV3TrapPrivacyAlgorithm3 choices are available: DES, AES, 3DESrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.73 |
siteV1CfgSNMPSNMPV3TrapUsernameThe SNMP V3 Trap UserName used for all the SNMP V3 trapsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.74 |
siteV1CfgSNMPSNMPV3TrapAuthPasswordThe SNMP V3 Trap Authentication Passwordrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.75 |
siteV1CfgSNMPSNMPV3TrapPrivacyPasswordThe SNMP V3 Trap Privacy Passwordrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.76 |
siteV1CfgSNMPSiteDescriptionIdsIncludedInTrapsList of site Description Elements to send on traps. (to have the site reference and the city in each trap for example). The list is separated with ';'rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.77 |
siteV1CfgGenericGenerateEventOnConfChangesThis is a True/False parameter used to activate or deactivate the tracking of configuration changesrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.81 |
siteV1CfgDataRecordsAutoArchivePeriodDataRecordPeriod in hour to auto save records (when detailled and long duration records are needed). 0 means disabled.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.82 |
siteV1CfgGenericGenerateEventOnControlExecutionThis is a True/False parameter used to activate or deactivate the tracking of control executionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.83 |
siteV1CfgGenericGenerateEventOnAlarmAcknowledgeThis is a True/False parameter used to activate or deactivate the tracking of alarm acknowledgmentrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.84 |
siteV1CfgInventoryRequiredCANBusNodeIDsThis is a coma separated list with the required CAN bus node idsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.91 |
siteV1CfgInventoryLSSCANidrangeBy default 50-80, means up to 50 Can Nodes like rectifiers with CAN Id 50 to 80. To support up to 100 rectifiers, change it to 1-100.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.92 |
siteV1CfgInventorySystemNodesDefinitiondc3(30-100)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.93 |
siteV1CfgInventoryLSSCANOpenSavedConfNArw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.95 |
siteV1CfgUsersAdministratorLoginPasswordThis is the login and the password of the administrator. It is saved with a special syntax. First the login in clear, followed of 2 points, followed of the MD5 hashed password. If you change the login:password by entering a non hashed password, this last is automatically hashed.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.101 |
siteV1CfgUsersUser1LoginPasswordThis is the login and the password of the user number 1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.102 |
siteV1CfgUsersUser2LoginPasswordThis is the login and the password of the user number 2.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.103 |
siteV1CfgUsersUser3LoginPasswordThis is the login and the password of the user number 3.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.104 |
siteV1CfgUsersUser4LoginPasswordThis is the login and the password of the user number 4.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.105 |
siteV1CfgUsersUser5LoginPasswordThis is the login and the password of the user number 5.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.106 |
siteV1CfgRadiusAuthenticationRadiusServerRadius Server address. If you have a secondary server, you could use a coma to separate it.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.111 |
siteV1CfgRadiusAuthenticationRadiusPortRadius Port. If you have a secondary server, you could use a coma to separate it.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.112 |
siteV1CfgRadiusAuthenticationRadiusSecretRadius PassPhraserw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.113 |
siteV1CfgEmailEnableEmailFeatureEnable/Disable the email featurerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.120 |
siteV1CfgEmailSmtpServerSmtp Server. If you are using a domain name, make sure you configured the network Dns (CF5)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.121 |
siteV1CfgEmailSmtpDomainSmtp Domain. (Required by some servers.)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.122 |
siteV1CfgEmailSmtpUserLoginPasswordSmtp Login and Password. The password is encrypted. To enter a new login and password, enter login:password and validate, the password will be encrypted.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.123 |
siteV1CfgEmailMailSenderMail Sender (The 'From' of the emails you will receive)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.130 |
siteV1CfgEmailMailRecipientsMail Recipients, separated with semicolon ';'rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.131 |
siteV1CfgEmailMinimalSeverityTypeToSendMailThis is the minimal severity of the event to send a Summary Mailrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.135 |
siteV1CfgControllerAutomaticRebootCron rules used in order to restart automatically the controller. Before rebooting configuration, events and data records are saved.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.150 |
siteV1CfgCloudLinkCloudEnabledEnable Cloud Connectionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.161 |
siteV1CfgCloudLinkCloudServerCloud Serverrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.162 |
siteV1CfgCloudLinkCloudPortCloud Portrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.163 |
siteV1CfgCloudLinkCloudCredentialEnter Credential of your AlphaCloud account in order to connect. You have to enter username:password in order to save your credential.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.164 |
siteV1CfgCloudLinkCloudClusterCloud Clusterrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.165 |
siteV1CfgInventoryRS485ExtensionsConfThe configuration string for RS485 Extensionsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.210 |
siteV1CfgInventoryEthernetExtensionsConfThe configuration string for Ethernet Extensionsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.220 |
siteV1CfgScriptingEnabledscriptsThis parameter enable all CompasLua Scripting capabilities. You can control scripts in Files -> Files manager > scripting tab.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.250 |
siteV1CfgScriptingNumberofErrorsbeforetriggeringalarmNumber of errors before triggering the scripting error alarm. When number of error is higher than this parameter, the alarm is triggered. If 0 is set, the alarm is deactivatedrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.251 |
siteV1CfgGenericReadAccessUserNumbersThe list of the user numbers which have read access to this equipment. The user numbers are coma separated. The accepted user id are 1,2,3,4 and 5. Ex: 1,3,4rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.521 |
siteV1CfgGenericWriteAccessUserNumbersThe list of the user numbers which have write access to this equipment. This means that these users can modify the configuration element, the alarm settings and use the control elements. The user numbers are coma separated. The accepted user ids are 1,2,3,4 and 5. Ex: 1,3,4rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.522 |
siteV1CfgGenericEventTableLengthThe maximum length of the table. The value must be comprised between 10 and 4000rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.601 |
siteV1CfgSNMPSNMPTrapTargetsIPOne or multiple target IP to send traps, coma separated. Ex: 130.145.23.1, 130.23.12.45rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.611 |
siteV1CfgSNMPMinimalEventSeverityForTrapsThis is the minimal severity of the event to send a SNMP traprw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.612 |
siteV1CfgXMLXMLEventsPrimPostURLThis is the first URL at which the events related to this equipment must be posted. The XML ETSI standard is used in the posted data content.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.651 |
siteV1CfgXMLXMLEventsPrimPostLoginThe login which must be used when posting events to the primary serverrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.652 |
siteV1CfgXMLXMLEventsPrimPostPasswordThe password which must be used when posting events to the primary serverrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.653 |
siteV1CfgXMLXMLEventsSecPostURLThis is the second URL at which the events related to this equipment must be posted. The XML ETSI standard is used in the posted data content. This allows having redundancy with the management server.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.661 |
siteV1CfgXMLXMLEventsSecPostLoginThe login which must be used when posting events to the secondary serverrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.662 |
siteV1CfgXMLXMLEventsSecPostPasswordThe password which must be used when posting events to the secondary serverrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.663 |
siteV1CfgPLCNumberOfPLCDataThe number of PLC data. Every equipment can manage up to 30 user programmable data. Data elements are automatically added in the data table. Configuration parameters are added to set the PLC Data Name and the PLC Data Mathematical calculation. In order to use these functionalities, you need a license with the 'PLC' modulerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.901 |
siteV1CfgPLCNumberOfPLCAlarmThe number of PLC alarm. Every equipment can manage up to 30 user programmable alarms. Alarm elements are automatically added in the alarm table. The alarm parameters are added to set the PLC Alarm Name and the PLC Alarm Boolean condition. In order to use these functionalities, you need a licence with the 'PLC' modulerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.15.3.902 |
siteV1Control OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.16 |
siteV1ControlNumberThe number of entries in the Control table related to the Sitero Integer32 .1.3.6.1.4.1.26854.3.2.1.16.1 |
siteV1ControlTableThe table of Control entries related to the Site SEQUENCE OF SiteV1ControlEntry .1.3.6.1.4.1.26854.3.2.1.16.2 |
siteV1ControlEntryA Control entry SiteV1ControlEntry .1.3.6.1.4.1.26854.3.2.1.16.2.1 |
siteV1ControlIndexThe Control entry Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.16.2.1.1 |
siteV1ControlNameThe Control entry namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.2.1.2 |
siteV1ControlValueThe Control entry valuerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.2.1.3 |
siteV1ControlEntryStatusThe status of this table entry - not used, only for compliancerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.2.1.4 |
siteV1ControlList OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.16.3 |
siteV1CtrlControllerRebootControllerWriting a '1' to this control element will reboot the monitoring. Events and Records will be saved.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.1 |
siteV1CtrlControllerSaveConfAndRebootControllerWriting a '1' to this control element will first save the actual configuration and will reboot the monitoring after.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.2 |
siteV1CtrlControllerRebootControllerWithoutSavingRecordsWriting a '1' to this control element will reboot the monitoring without saving recordsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.3 |
siteV1CtrlNetworkApplyNetworkConfWriting a '1' to this control element will reconfigure the ethernet according to the Network Configuration. If you change the IP address in the config table without using this command after, the configuration is not applied.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.6 |
siteV1CtrlTimeForceSNTPTimeRefreshWriting a '1' to this control element will force the monitoring to try to refresh his time with the configured SNTP Time Server.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.11 |
siteV1CtrlTimeSetLocalTimeWriting a date and time to this control element allows to manually change the local time of the monitoring. The syntax of the date and the time is: 2007-11-19T13:02:34rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.12 |
siteV1CtrlTimeSetUTCTimeWriting a date and time to this control element allows to manually change the UTC time of the monitoring. The syntax of the date and the time is: 2007-11-19T13:02:34rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.13 |
siteV1CtrlTimeResetUptimeWriting a '1' to this control element will reset the uptime of the monitoring.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.14 |
siteV1CtrlControllerCleanandSaveXMLUserConfWriting a '1' to this control element will remove the configuration sections related to missing equipments, than save all the configuration of all the connected equipment in a XML format. This file is read when the monitoring is starting in order to configure the monitoring. This file is also accessible trough the FTP server or can be downloaded trough the web interface.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.20 |
siteV1CtrlControllerSaveXMLUserConfWriting a '1' to this control element will save all the configuration of all the connected (or previously connected) equipment in a XML format. This file is read when the monitoring is starting in order to configure the monitoring. This file is also accessible trough the FTP server or can be downloaded trough the web interface.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.21 |
siteV1CtrlControllerSaveInventoryWriting a '1' to this control element will save save the inventory in a XML format. This file is read when the monitoring is starting in order to configure the monitoring. This file is also accessible trough the FTP server or can be downloaded trough the web interface.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.22 |
siteV1CtrlDataRecordsSaveDataRecordsWriting a '1' to this control element will force the monitoring to save all the data records. This is useful if you want to unpower the Comp@s monitoring. This function is called automatically everyday.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.33 |
siteV1CtrlDataRecordsExportDataRecordsinCSVWriting a '1' to this control element will force the monitoring to save all the CVS records files. The CSV files are stored in the records folder.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.34 |
siteV1CtrlDataRecordsArchiveDataRecordsWriting a '1' to this control element will force the monitoring to save all the data records. This is useful if you want to unpower the Comp@s monitoring. This function is called automatically everyday.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.35 |
siteV1CtrlDataRecordsDeleteAllDataRecordsWriting a '1' to this control element will force the monitoring to save all the data records. This is useful if you want to unpower the Comp@s monitoring. This function is called automatically everyday.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.36 |
siteV1CtrlControllerEmulateRecordsNArw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.40 |
siteV1CtrlControllerReloadTranslationsWriting a '1' to this control element will reload all the csv translation filesrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.41 |
siteV1CtrlControllerReloadLicenseWriting a '1' to this control element will reload the license filerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.51 |
siteV1CtrlControllerManageFTPServerThis Control is used to manage the FTP Serverrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.55 |
siteV1CtrlInventoryRemoveAbsentEquipmentsNArw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.61 |
siteV1CtrlInventoryResetCANBusNodeWriting a valid CAN bus node id to this control element will reset the correspondent device.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.81 |
siteV1CtrlInventorySaveCANOpenLSSConfNArw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.82 |
siteV1CtrlInventoryStartNewInventoryNArw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.83 |
siteV1CtrlInventoryUpgradeNodeFirmwareThis control element is used to start the firmware upgrade of a CAN bus Node. You need to upload first the firmware trough ftp in the /user/firmware path. Then you need to write the id number of the CAN Node, followed by a coma, followed by the file name. Example : '101,SOFT_0000030_01.txt'.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.91 |
siteV1CtrlInventoryCancelFirmwareUpgradeThis control element is used to cancel the running firmware upgrade of a CAN bus Node.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.92 |
siteV1CtrlFilesFlashBinaryThis control element is used to start a binary flash update. You need to upload first the firmware trough ftp in the /user/firmware path.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.103 |
siteV1CtrlFilesDownloadFileFromUrlThis control element is used to download a file wiht HTTP get, the argument is an url. The file is saved in the upload folderrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.110 |
siteV1CtrlFilesDeleteUserUploadedFileThis control element is used to delete a file in the user-upload folder. This is riskless as these files are not used, they are temporary files.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.111 |
siteV1CtrlFilesMoveUserUploadedFileThis control element is used to copy a file from the user-upload folder to another one. Be aware of what your are doing !rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.112 |
siteV1CtrlFilesExtractZipFileinuseruploadThis control element is used to delete a file in the user-upload folder. This is riskless as these files are not used, they are temporary files.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.113 |
siteV1CtrlEmailSendSummaryEmailThis control element is used to force the sending of a summary to the configured mail addressrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.120 |
siteV1CtrlScriptingControlLuaScriptThis control element is used to control the lua scripting system. Available command are: enable[Enable Lua Capabilities], disable[Disable Lua Capabilities], restart[Restart All Lua Capabilities], refresh[Read the folder script (if you added a file when system is running)], enable filename[enable filename.lua located in folder user/scripts], disable filename[disable filename.lua located in folder user/scripts], restart filename : Restart fileName[file must be enabled], reseterrors[Reset all errors counters], reseterrors filename[Reset errors from filenamerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.250 |
siteV1CtrlControllerAdvancedFunctionGenericCommandExecutionThis control is used to perform advanced operation.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.300 |
siteV1CtrlGenericClearMyEventsBy writing '1' to this control element, all the events of this equipment will be cleared.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.501 |
siteV1CtrlGenericClearAllEventsBy writing '1' to this control element, all the events of this equipment and all the events of all the sub-equipments will be cleared.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.502 |
siteV1CtrlGenericAddEventThis control element adds an event of severity none. The event name is the text written to this control elementrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.511 |
siteV1CtrlGenericAddMajorEventThis control element adds an event of severity major. The event name is the text written to this control elementrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.512 |
siteV1CtrlGenericResetDefaultNamesAndGroupsThis control element resets all the element Names, Groups and Subgroups to default values for this equipmentrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.521 |
siteV1CtrlGenericResetDefaultNamesAndGroupsRecursiveThis control element resets all the element Names, Groups and Subgroups to default values for this equipment and all sub equipmentsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.16.3.522 |
siteV1Notifications OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.18 |
siteV1NotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.18.0 |
siteV1NotificationOfEventNotification generated when a new event appears NOTIFICATION-TYPE .1.3.6.1.4.1.26854.3.2.1.18.0.1 |
siteV1Compliance OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.19 |
siteV1ComplianceGroups OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.19.1 |
siteV1GlobalGrouptext Unknown .1.3.6.1.4.1.26854.3.2.1.19.1.1 |
siteV1NotificationGrouptext Unknown .1.3.6.1.4.1.26854.3.2.1.19.1.2 |
siteV1FullComplianceThe compliance statement for SNMPV2 entities which implement the SNMPV2 MIB. Unknown .1.3.6.1.4.1.26854.3.2.1.19.2 |
energySystems OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20 |
es1 OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1 |
es1GlobalStatusA textual string (alarms, normal or unknown) containing the status of the Energy Systemro DisplayString .1.3.6.1.4.1.26854.3.2.1.20.1.1 |
es1GlobalAlarmSeverityTypeThe alarm severity type (critical, major, minor, warning, none, disabled) of the Energy Systemro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.2 |
es1GlobalAlarmSeverityLevelThe alarm severity level (0-9) of the Energy Systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.3 |
es1GlobalAlarmSeverityTypeIntThe alarm severity type as integer (critical=4, major=3, minor=2, warning=1, none=0) of the Energy Systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.4 |
es1Description OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.10 |
es1DescriptionNumberThe number of entries in the Energy System Description tablero Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.10.1 |
es1DescriptionTableThe Description table of the Energy System SEQUENCE OF Es1DescriptionEntry .1.3.6.1.4.1.26854.3.2.1.20.1.10.2 |
es1DescriptionEntryA Description entry Es1DescriptionEntry .1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1 |
es1DescriptionIndexDescription Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1.1 |
es1DescriptionNameDescription Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1.2 |
es1DescriptionValueDescription Valuerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1.3 |
es1DescriptionEntryStatusThe status of this table entryrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.10.2.1.4 |
es1DescriptionList OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.10.3 |
es1DescDescriptionDescriptionA free text zone to write a system descriptionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.10.3.1 |
es1DescDescriptionReferenceA free text zone to write the customer reference of the systemrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.10.3.2 |
es1Alarm OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.11 |
es1AlarmNumberThe number of entries in the Energy System Alarm tablero Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.11.1 |
es1AlarmTableThe table of Alarm entries SEQUENCE OF Es1AlarmEntry .1.3.6.1.4.1.26854.3.2.1.20.1.11.2 |
es1AlarmEntryAn alarm entry Es1AlarmEntry .1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1 |
es1AlarmIndexAlarm Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.1 |
es1AlarmNameAlarm Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.2 |
es1AlarmActiveIs the Alarm active ? 'true' for active, 'false' for not-activero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.3 |
es1AlarmSeverityTypeThe alarm severity type (major, minor, warning, none, disabled) of this alarm entryrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.4 |
es1AlarmSeverityLevelThe alarm severity level (0-9) of this alarm entryrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.5 |
es1AlarmStartTimeThe last start time of this alarm entry (null if never active)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.6 |
es1AlarmStopTimeThe last stop time of this alarm entry (null if alarm active)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.7 |
es1AlarmEntryStatusThe status of this table entry - not used, only for MIB compliancerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.11.2.1.8 |
es1AlarmSummarySummary bit vector with all the alarms state of the Energy System. A '1' means alarm active, '0' means not active. Unimplemented alarms are always '0'.ro Bits .1.3.6.1.4.1.26854.3.2.1.20.1.11.3 |
es1Event OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.12 |
es1EventNumberThe number of entries in the Event Table related to the Energy Systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.12.1 |
es1EventTableThe Event table related to the Energy System SEQUENCE OF Es1EventEntry .1.3.6.1.4.1.26854.3.2.1.20.1.12.2 |
es1EventEntry. Es1EventEntry .1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1 |
es1EventIndexEvent Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.1 |
es1EventIdEvent Indexro Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.2 |
es1EventNameEvent Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.3 |
es1EventDateTimeThe date and time of the eventro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.4 |
es1EventSeverityTypeThe event severity type ('major', 'minor', 'warning' or 'none')ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.5 |
es1EventSeverityLevelThe event severity level (0-9)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.6 |
es1EventEntryStatusThe status of this table entryrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.12.2.1.7 |
es1Data OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.13 |
es1DataNumberThe number of entries in the Data Table related to the Energy Systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.13.1 |
es1Config OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.15 |
es1ConfigNumberThe number of entries in the Config table related to the Energy Systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.15.1 |
es1ConfigTableThe table of Config entries related to the Energy System SEQUENCE OF Es1ConfigEntry .1.3.6.1.4.1.26854.3.2.1.20.1.15.2 |
es1ConfigEntryA Config entry Es1ConfigEntry .1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1 |
es1ConfigIndexThe Config entry Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1.1 |
es1ConfigNameThe Config entry namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1.2 |
es1ConfigValueThe Config entry valuerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1.3 |
es1ConfigEntryStatusThe status of this table entry - not used, only for compliancerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.15.2.1.4 |
es1ConfigList OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.15.3 |
es1CfgEnergyMeterNumberOfGenericPulseEnergyCounterNArw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.15.3.100 |
es1Control OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.16 |
es1ControlNumberThe number of entries in the Control table related to the Energy Systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.16.1 |
es1ControlTableThe table of Control entries related to the Energy System SEQUENCE OF Es1ControlEntry .1.3.6.1.4.1.26854.3.2.1.20.1.16.2 |
es1ControlEntryA Control entry Es1ControlEntry .1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1 |
es1ControlIndexThe Control entry Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1.1 |
es1ControlNameThe Control entry namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1.2 |
es1ControlValueThe Control entry valuerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1.3 |
es1ControlEntryStatusThe status of this table entry - not used, only for compliancerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.16.2.1.4 |
es1ControlList OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.16.3 |
es1CtrlGenericClearMyEventsBy writing '1' to this control element, all the events of this equipment will be cleared.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.16.3.501 |
es1CtrlGenericClearAllEventsBy writing '1' to this control element, all the events of this equipment and all the events of all the sub-equipments will be cleared.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.16.3.502 |
es1CtrlGenericAddEventThis control element adds an event of severity none. The event name is the text written to this control elementrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.16.3.511 |
es1CtrlGenericAddMajorEventThis control element adds an event of severity major. The event name is the text written to this control elementrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.16.3.512 |
es1CtrlGenericResetDefaultNamesAndGroupsThis control element resets all the element Names, Groups and Subgroups to default values for this equipmentrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.16.3.521 |
es1CtrlGenericResetDefaultNamesAndGroupsRecursiveThis control element resets all the element Names, Groups and Subgroups to default values for this equipment and all sub equipmentsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.16.3.522 |
es1Notifications OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.18 |
es1NotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.18.0 |
es1NotificationOfEventNotification generated when a new event appears NOTIFICATION-TYPE .1.3.6.1.4.1.26854.3.2.1.20.1.18.0.1 |
es1Compliance OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.19 |
es1ComplianceGroups OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.19.1 |
es1GlobalGrouptext Unknown .1.3.6.1.4.1.26854.3.2.1.20.1.19.1.1 |
es1NotificationGrouptext Unknown .1.3.6.1.4.1.26854.3.2.1.20.1.19.1.2 |
es1FullComplianceThe compliance statement for SNMPV2 entities which implement the SNMPV2 MIB. Unknown .1.3.6.1.4.1.26854.3.2.1.20.1.19.2 |
es1DCSystems OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20 |
es1dc1 OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1 |
es1dc1GlobalStatusA textual string (alarms, normal or unknown) containing the status of the DC Systemro DisplayString .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.1 |
es1dc1GlobalAlarmSeverityTypeThe alarm severity type (critical, major, minor, warning, none, disabled) of the DC Systemro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.2 |
es1dc1GlobalAlarmSeverityLevelThe alarm severity level (0-9) of the DC Systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.3 |
es1dc1GlobalAlarmSeverityTypeIntThe alarm severity type as integer (critical=4, major=3, minor=2, warning=1, none=0) of the DC Systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.4 |
es1dc1Description OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10 |
es1dc1DescriptionNumberThe number of entries in the DC System Description tablero Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.1 |
es1dc1DescriptionTableThe Description table of the DC System SEQUENCE OF Es1dc1DescriptionEntry .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2 |
es1dc1DescriptionEntryA Description entry Es1dc1DescriptionEntry .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1 |
es1dc1DescriptionIndexDescription Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1.1 |
es1dc1DescriptionNameDescription Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1.2 |
es1dc1DescriptionValueDescription Valuerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1.3 |
es1dc1DescriptionEntryStatusThe status of this table entryrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.2.1.4 |
es1dc1DescriptionList OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3 |
es1dc1DescDescriptionDescriptionA free text zone to write a system descriptionrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.1 |
es1dc1DescDescriptionReferenceA free text zone to write the customer reference of the systemrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.2 |
es1dc1DescDescriptionProductNameThe product name of the DC system monitoringro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.11 |
es1dc1DescDescriptionHardwareReferenceThe hardware reference of the DC system monitoringro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.12 |
es1dc1DescDescriptionSoftwareReferenceThe software reference of the DC system monitoringro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.14 |
es1dc1DescDescriptionSerialNumberThe serial number of the DC system monitoringro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.16 |
es1dc1DescDescriptionManufacturingDateThe production date of the DC system monitoringro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.18 |
es1dc1DescDescriptionDistributionModuleProductNameThe product name of the Electronic Distribution/LVD Modulero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.31 |
es1dc1DescDescriptionDistributionModuleHardwareReferenceThe hardware reference of the Electronic Distribution/LVD Modulero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.32 |
es1dc1DescDescriptionDistributionModuleSoftwareReferenceThe software reference of the Electronic Distribution/LVD Modulero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.34 |
es1dc1DescDescriptionDistributionModuleSerialNumberThe serial number of the Electronic Distribution/LVD Modulero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.36 |
es1dc1DescDescriptionDistributionModuleManufacturingDateThe manufacturing date of the Electronic Distribution/LVD Modulero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.10.3.38 |
es1dc1Alarm OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11 |
es1dc1AlarmNumberThe number of entries in the DC System Alarm tablero Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.1 |
es1dc1AlarmTableThe table of Alarm entries SEQUENCE OF Es1dc1AlarmEntry .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2 |
es1dc1AlarmEntryAn alarm entry Es1dc1AlarmEntry .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1 |
es1dc1AlarmIndexAlarm Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.1 |
es1dc1AlarmNameAlarm Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.2 |
es1dc1AlarmActiveIs the Alarm active ? 'true' for active, 'false' for not-activero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.3 |
es1dc1AlarmSeverityTypeThe alarm severity type (major, minor, warning, none, disabled) of this alarm entryrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.4 |
es1dc1AlarmSeverityLevelThe alarm severity level (0-9) of this alarm entryrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.5 |
es1dc1AlarmStartTimeThe last start time of this alarm entry (null if never active)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.6 |
es1dc1AlarmStopTimeThe last stop time of this alarm entry (null if alarm active)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.7 |
es1dc1AlarmEntryStatusThe status of this table entry - not used, only for MIB compliancerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.2.1.8 |
es1dc1AlarmSummarySummary bit vector with all the alarms state of the DC System. A '1' means alarm active, '0' means not active. Unimplemented alarms are always '0'.ro Bits .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.11.3 |
es1dc1Event OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12 |
es1dc1EventNumberThe number of entries in the Event Table related to the DC Systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.1 |
es1dc1EventTableThe Event table related to the DC System SEQUENCE OF Es1dc1EventEntry .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2 |
es1dc1EventEntry. Es1dc1EventEntry .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1 |
es1dc1EventIndexEvent Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.1 |
es1dc1EventIdEvent Indexro Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.2 |
es1dc1EventNameEvent Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.3 |
es1dc1EventDateTimeThe date and time of the eventro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.4 |
es1dc1EventSeverityTypeThe event severity type ('major', 'minor', 'warning' or 'none')ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.5 |
es1dc1EventSeverityLevelThe event severity level (0-9)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.6 |
es1dc1EventEntryStatusThe status of this table entryrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.12.2.1.7 |
es1dc1Data OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13 |
es1dc1DataNumberThe number of entries in the Data Table related to the DC Systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.1 |
es1dc1DataTableThe table of Data entries SEQUENCE OF Es1dc1DataEntry .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2 |
es1dc1DataEntryA data entry Es1dc1DataEntry .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1 |
es1dc1DataIndexThe data index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1.1 |
es1dc1DataNameThe data namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1.2 |
es1dc1DataValueThe data valuero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1.3 |
es1dc1DataEntryStatusThe status of this table entry - not used, only present for compliancerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.2.1.4 |
es1dc1DataList OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3 |
es1dc1DataSystemDCModeThe DC system can have 5 values: 'Float'(0), 'Equalize'(1), 'Battery Test'(2), 'Ac Failure'(3) or 'Safe'(5)ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.1 |
es1dc1DataSystemPreviousDCModeThe previous value of the DC Mode : 'Float'(0), 'Equalize'(1), 'Battery Test'(2), 'Ac Failure'(3) or 'Safe'(5)ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.2 |
es1dc1DataSystemNiMHChargeModeNAro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.5 |
es1dc1DataDCBusBusVoltageThe DC bus voltage in volt.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.11 |
es1dc1DataSystemRatioDeliveredOnAvailablePowerThis is the ratio of the delivered power divided by the installed power, in %.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.12 |
es1dc1DataACBusMinutesSinceLastACFailBeginThe number of minute since the last AC Failure beginro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.13 |
es1dc1DataACBusMinutesSinceLastACFailEndThe number of minute since the last AC Failure endro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.14 |
es1dc1DataRectifiersRectifiersOutPowerThe sum of the delivered rectifier powerro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.21 |
es1dc1DataRectifiersRectifiersOutCurrentThe sum of the delivered rectifier currentro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.22 |
es1dc1DataRectifiersRectifiersOutPowerMaxThe sum of the deliverable rectifier powerro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.23 |
es1dc1DataRectifiersRectifiersOutCurrentMaxThe sum of the deliverable rectifier currentro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.24 |
es1dc1DataRectifiersNumberOfRectifierMaxThe maximum possible number of rectifier in this dc systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.31 |
es1dc1DataRectifiersNumberOfPresentRectifierThe actual number of present rectifier in this dc systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.32 |
es1dc1DataRectifiersNumberOfAbsentRectifierThe actual number of absent rectifier in this dc systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.33 |
es1dc1DataRectifiersNumberOfActiveRectifierThe actual number of active rectifier in this dc system. An active rectifier is a rectifier which is present, DC OK, AC OK and not in remote off.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.34 |
es1dc1DataRectifiersNumberOfACFailRectifierThe actual number or rectifier in AC Failure.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.35 |
es1dc1DataRectifiersNumberOfDCFailRectifierThe actual number or rectifier with DC Failure.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.36 |
es1dc1DataRectifiersNumberOfRemoteOffRectifierThe actual number or rectifier in remote off.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.37 |
es1dc1DataRectifiersNumberOfOverTempRectifierThe actual number or rectifier in Over Temperature.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.38 |
es1dc1DataLoadLoadPowerEstimation of the load power consumptionro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.51 |
es1dc1DataLoadLoadCurrentEstimation of the load current consumptionro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.52 |
es1dc1DataBatBatInputCurrentMeasurement of the battery input current. A negative value means that the battery is dischargingro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.61 |
es1dc1DataBatBatInputPowerMeasurement of the battery input power. A negative value means that the battery is dischargingro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.62 |
es1dc1DataBatBatTempThe battery temperaturero Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.71 |
es1dc1DataBatBatTestStateThis is about the result of the last battery test. 10 values are possible : 'Never Tested'(0), 'Success'(1), 'On Going'(2), 'Failed: Timeout'(3), 'Failed: Vbus Too Low'(4), 'Failed: Load Too Low'(5), 'Failed: Ac Failure'(6), 'Failed: Canceled' (7), 'Failed: Lvd Opened'(8), 'Failed: No Battery'(9)ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.72 |
es1dc1DataBatLastBatTestDischargedCapacityRatioThis is the battery capacity, in percent, discharged during the last battery test. This value is updated at the end of the battery test.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.73 |
es1dc1DataBatLastBatTestDischargedCapacityThis is the battery capacity, in ampere hour, discharged during the last battery test. This value is updated at the end of the battery test.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.74 |
es1dc1DataBatLastBatTestFinalVoltageThis is the bus voltage at the end of the last battery test. This value is updated at the end of the battery test.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.75 |
es1dc1DataBatBatTestDurationThe duration of the last battery test. This value is updated at the end of the battery test. This value can't be higher than 1440 minutes (24 hours).ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.76 |
es1dc1DataBatPreviousBatTestDischargedCapacityRatioThis is the battery capacity, in percent, discharged during the previous battery test. This value is shifted at the end of the battery test.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.77 |
es1dc1DataBatPreviousBatTestDischargedCapacityThis is the battery capacity, in ampere hour, discharged during the previous battery test. This value is shifted at the end of the battery test.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.78 |
es1dc1DataBatPreviousBatTestFinalVoltageThis is the bus voltage at the end of the previous battery test. This value is shifted at the end of the battery test.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.79 |
es1dc1DataBatPreviousBatTestDurationThe duration of the previous battery test. This value is shifted at the end of the battery test. This value can't be higher than 1440 minutes (24 hours).ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.80 |
es1dc1DataBatPreviousBatTestStateThe result of the previous battery test - 10 values are possible: 'Never Tested'(0), 'Success'(1), 'On Going'(2), 'Failed: Timeout'(3), 'Failed: Vbus Too Low'(4), 'Failed: Load Too Low'(5), 'Failed: Ac Failure'(6), 'Failed: Canceled', 'Failed: Lvd Opened'(8), 'Failed: No Battery'(9)ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.81 |
es1dc1DataBatMinutesSinceLastTestBatThe number of minute since the end of last battery testro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.82 |
es1dc1DataBatNextScheduledBatTestThe date and time of the next time the scheduled battery test will runro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.84 |
es1dc1DataBatBatChargeCapacityThe battery charge capacity, calculated by integration of the current.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.91 |
es1dc1DataBatCalculatedAutonomyCalculation of the remaining autonomy. This value can change following the load of your system and the maximal depth of dicharge configuration (CF39).ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.92 |
es1dc1DataBatBatCurrentIntegrationActual value of the integration of the current, in Ampere * hourro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.94 |
es1dc1DataLVDLVDStateActual state of the LVDro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.101 |
es1dc1DataRelsRel1StateActual state of the Relay 1ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.111 |
es1dc1DataRelsRel2StateActual state of the Relay 2ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.112 |
es1dc1DataRelsRel3StateActual state of the Relay 3ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.113 |
es1dc1DataRelsRel4StateActual state of the Relay 3ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.114 |
es1dc1DataSmartEnergyEfficiencyOptimizedNumberOfRectifierThe optimal number of ON rectifier for Efficiency Optimizationro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.121 |
es1dc1DataSmartEnergySystemLossWithoutOptimisationEstimation of the losses without optimisationro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.122 |
es1dc1DataSmartEnergySystemLossWithOptimisationEstimation of the losses with optimisationro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.123 |
es1dc1DataSmartEnergyRectifierModelUsedForCalculationThe rectifier model usedro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.124 |
es1dc1DataSmartEnergySmartEnergySavingsEstimation of the losses with optimisationro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.125 |
es1dc1DataSensorsAmbientTempThe ambiant temperature (second temperature sense)ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.151 |
es1dc1DataSensorsPulseCounter4The counter value of the digital input 4.ro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.13.3.204 |
es1dc1Config OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15 |
es1dc1ConfigNumberThe number of entries in the Config table related to the DC Systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.1 |
es1dc1ConfigTableThe table of Config entries related to the DC System SEQUENCE OF Es1dc1ConfigEntry .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2 |
es1dc1ConfigEntryA Config entry Es1dc1ConfigEntry .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1 |
es1dc1ConfigIndexThe Config entry Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1.1 |
es1dc1ConfigNameThe Config entry namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1.2 |
es1dc1ConfigValueThe Config entry valuerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1.3 |
es1dc1ConfigEntryStatusThe status of this table entry - not used, only for compliancerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.2.1.4 |
es1dc1ConfigList OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3 |
es1dc1CfgDCBusDCBusFloatVoltageat25degCThe floating dc bus voltage of the system at 25 Celsius degreerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.1 |
es1dc1CfgDCBusDCBusVoltageExtraLowThe bus voltage under which the alarm 'DC Bus Voltage Extra Low' is set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.2 |
es1dc1CfgDCBusDCBusVoltageExtraLowHysteresisThe voltage hysteresis on the alarm 'DC Bus Voltage Extra Low'.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.3 |
es1dc1CfgDCBusDCBusVoltageLowThe bus voltage under which the alarm 'DC Bus Voltage Low' is set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.4 |
es1dc1CfgDCBusDCBusVoltageLowHysteresisThe voltage hysteresis on the alarm 'DC Bus Voltage Lowrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.5 |
es1dc1CfgDCBusDCBusVoltageHighThe bus voltage over which the alarm 'DC Bus Voltage High' is set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.6 |
es1dc1CfgDCBusDCBusVoltageHighHysteresisThe voltage hysteresis on the alarm 'DC Bus Voltage Highrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.7 |
es1dc1CfgDCBusDCBusVoltageExtraHighThe bus voltage over which the alarm 'DC Bus Voltage Extra High' is set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.8 |
es1dc1CfgDCBusDCBusVoltageExtraHighHysteresisThe voltage hysteresis on the alarm 'DC Bus Voltage Extra Highrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.9 |
es1dc1CfgLVDLVDDisconnectVoltageThe dc bus voltage under which the battery must be disconnected of the bus. This allows preserving the battery life. The load will be unpowered. This value has to be lower than the Battery test end voltage (CF70)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.10 |
es1dc1CfgLVDLVDDisconnectDelayThe delay in second before disconnecting the battery if the dc bus voltage is under the configured disconnected voltage. This avoids disconnection during a low bus transient.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.11 |
es1dc1CfgBatTempCompensationSlopeThe slope of the battery temperature compensation in mv/degree. For a 48V system, -72mV/degree is often used.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.21 |
es1dc1CfgBatMaxPosTempCompensationThe maximal allowed positive compensation.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.22 |
es1dc1CfgBatMaxNegTempCompensationThe maximal allowed negative compensation.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.23 |
es1dc1CfgRectifiersMinimalNumberOfPresentRectifiersThe minimal number of rectifier which must be present. If there is less present rectifiers, the alarm 'Missing Rectifiers' is set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.25 |
es1dc1CfgRectifiersRectifierModelThe rectifier modelrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.26 |
es1dc1CfgRectifiersForcedRemoteOffRectifersA list of rectifier which are forced in remote off. The id of the rectifier must be coma separated. Ex: 1,3 will maintain rectifier 1 and 3 off.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.27 |
es1dc1CfgBatBatChargeCurrentLimitThe maximal battery current when the battery is charging. The monitoring regulates the bus voltage in order to satisfy this condition. This parameter is often equal to the nominal battery capacity divided by 10.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.31 |
es1dc1CfgBatBatStringCapacityThe battery capacity in Ah.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.32 |
es1dc1CfgBatBatTempLowThe temperature under which the alarm 'Battery Temperature Too Low' must be set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.33 |
es1dc1CfgBatBatTempHighThe temperature over which the alarm 'Battery Temperature Too High' must be set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.34 |
es1dc1CfgBatBatTempHysteresisThe hysteresis on the 'Battery Temperature Too High' and 'Battery Temperature Too Low' alarms.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.35 |
es1dc1CfgBatMinimalCurrentForDischargingAlarmThe minimal discharging current to set the 'Battery On Discharge' alarm.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.36 |
es1dc1CfgBatCurrentHysteresisForDischargingAlarmThe hysteresis on the 'Battery On Discharge' alarm.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.37 |
es1dc1CfgBatPeukertNumberThe Peukert number relates to the internal resistance of a battery and provides an indication of the excpected capacity. The ideal number is 1. This value can be calculated with the formula: (ln(t2)-ln(t1))/(ln(i1)-ln(i2)) where tx is the autonomy in hours at a constant discharge current of ix Amps. Often, we use t1 = 1h and t2 = 10hrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.38 |
es1dc1CfgBatMaxDepthOfDischargeforAutonomyEstimationIt is generally recommended to discharge maximum 60% of the battery capacity to enhance battery lifetime. By default, 100% is used for autonomy calculation. This parameter can also be used to take into account the age of the batteryrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.39 |
es1dc1CfgBatBoostAutomaticThe boost mode must be automatically after the fact that during a mains failure, the bus voltage went under the configured 'Boost Activation Low Voltage'. This allows charging the battery faster.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.51 |
es1dc1CfgBatBoostActivationLowVoltageThe voltage under which the boost mode can be activated.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.52 |
es1dc1CfgBatBoostTerminationVoltageThe voltage over which the system must go back to floating mode.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.53 |
es1dc1CfgBatBoostTerminationCurrentThe battery charging current under which the system must go back to floating mode.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.54 |
es1dc1CfgBatBoostTerminationTimeThe time in minute after which the system must go back in floating mode.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.55 |
es1dc1CfgBatBatTestTypeType of the battery test: <br> Capacity based: The battery must give the requested capacity before falling lower than a value <br>Time Based: The battery must sustain a defined load during a defined time.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.69 |
es1dc1CfgBatBatTestEndVoltageThe voltage at which any battery test must be stopped. This value has to be higher than the LVD Disconnect voltage (CF10)rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.70 |
es1dc1CfgBatBatTestDischargeRatioThe ratio of the battery capacity to discharge. If 30 is set, 30% of the battery will be discharged during the testrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.71 |
es1dc1CfgBatBatTestIntervalThe number of days between two automatically started battery test. If this parameter is set to 0, the battery test is not started automatically. The user can remotely or locally start or force this test.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.72 |
es1dc1CfgBatBatTestDischargeCurrentThe current at which the battery must be discharged during a battery test. The monitoring regulates the bus voltage in order to satisfy this condition. The load current must be of course higher than this parameter.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.73 |
es1dc1CfgBatBatTestMinimalDischargeCurrentThe battery current under which the battery test must be stopped because the load is too low.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.74 |
es1dc1CfgBatBatTestDurationThe timeout in minute after which the battery test must be stopped.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.75 |
es1dc1CfgBatBatTestRequMinutesWithoutMainsFailThe minimal time in minute without mains failure in order to allow a battery start. This parameter is not taken into account when the battery test is forced.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.76 |
es1dc1CfgBatBatTestSchedulerCronRuleNArw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.77 |
es1dc1CfgSmartEnergySmartEnergyBooleanCondThis is the boolean condition which allows or not to automatically optimize the number of rectifier in remote off.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.83 |
es1dc1CfgLVDBatLVDNodeIdThis is a list of the node id of the Smart Electronic LVDs, coma separatedrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.86 |
es1dc1CfgDigInputsDigInput1NameThe name of the digital input 1rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.91 |
es1dc1CfgDigInputsDigInput1NormallyClosedTrue/False value defining if the digital input 1 is normally closed. If this digital input is not in this default state, the related alarm is set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.92 |
es1dc1CfgDigInputsDigInput2NameThe name of the digital input 2rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.93 |
es1dc1CfgDigInputsDigInput2NormallyClosedTrue/False value defining if the digital input 2 is normally closed. If this digital input is not in this default state, the related alarm is set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.94 |
es1dc1CfgDigInputsDigInput3NameThe name of the digital input 3rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.95 |
es1dc1CfgDigInputsDigInput3NormallyClosedTrue/False value defining if the digital input 3 is normally closed. If this digital input is not in this default state, the related alarm is set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.96 |
es1dc1CfgDigInputsDigInput4NameThe name of the digital input 4rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.97 |
es1dc1CfgDigInputsDigInput4NormallyClosedTrue/False value defining if the digital input 4 is normally closed. If this digital input is not in this default state, the related alarm is set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.98 |
es1dc1CfgDigInputsDigInput5NameThe name of the digital input 5rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.99 |
es1dc1CfgDigInputsDigInput5NormallyClosedTrue/False value defining if the digital input 5 is normally closed. If this digital input is not in this default state, the related alarm is set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.100 |
es1dc1CfgDigInputsDigInput6NameThe name of the digital input 6rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.101 |
es1dc1CfgDigInputsDigInput6NormallyClosedTrue/False value defining if the digital input 6 is normally closed. If this digital input is not in this default state, the related alarm is set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.102 |
es1dc1CfgRelsDryAlarm1AlternativeBooleanCondAnother Boolean condition to activate the dry alarm relay 1. The way to define boolean condition is detailed in the PLC chapter.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.111 |
es1dc1CfgRelsDryAlarm2AlternativeBooleanCondAnother Boolean condition to activate the dry alarm relay 2. The way to define boolean condition is detailed in the PLC chapter.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.112 |
es1dc1CfgRelsDryAlarm3AlternativeBooleanCondAnother Boolean condition to activate the dry alarm relay 3. The way to define boolean condition is detailed in the PLC chapter.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.113 |
es1dc1CfgRelsDryAlarm4AlternativeBooleanCondAnother Boolean condition to activate the dry alarm relay 4. The way to define boolean condition is detailed in the PLC chapter.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.114 |
es1dc1CfgSensorsAmbientTempLowThe temperature under which the alarm 'Ambiant Temperature Too Low' must be set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.131 |
es1dc1CfgSensorsAmbientTempHighThe temperature under which the alarm 'Ambiant Temperature Too Low' must be set.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.132 |
es1dc1CfgSensorsAmbientTempHysteresisThe hysteresis on the 'Battery Temperature Too High' and 'Battery Temperature Too Low' alarms.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.133 |
es1dc1CfgGenericReadAccessUserNumbersThe list of the user numbers which have read access to this equipment. The user numbers are coma separated. The accepted user id are 1,2,3,4 and 5. Ex: 1,3,4rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.521 |
es1dc1CfgGenericWriteAccessUserNumbersThe list of the user numbers which have write access to this equipment. This means that these users can modify the configuration element, the alarm settings and use the control elements. The user numbers are coma separated. The accepted user ids are 1,2,3,4 and 5. Ex: 1,3,4rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.522 |
es1dc1CfgGenericEventTableLengthThe maximum length of the table. The value must be comprised between 10 and 4000rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.601 |
es1dc1CfgGenericEventTableLengthByRectifierThe maximum length of the table. The value must be comprised between 10 and 4000rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.602 |
es1dc1CfgPLCNumberOfPLCDataThe number of PLC data. Every equipment can manage up to 30 user programmable data. Data elements are automatically added in the data table. Configuration parameters are added to set the PLC Data Name and the PLC Data Mathematical calculation. In order to use these functionalities, you need a license with the 'PLC' modulerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.901 |
es1dc1CfgPLCNumberOfPLCAlarmThe number of PLC alarm. Every equipment can manage up to 30 user programmable alarms. Alarm elements are automatically added in the alarm table. The alarm parameters are added to set the PLC Alarm Name and the PLC Alarm Boolean condition. In order to use these functionalities, you need a licence with the 'PLC' modulerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.15.3.902 |
es1dc1Control OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16 |
es1dc1ControlNumberThe number of entries in the Control table related to the DC Systemro Integer32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.1 |
es1dc1ControlTableThe table of Control entries related to the DC System SEQUENCE OF Es1dc1ControlEntry .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2 |
es1dc1ControlEntryA Control entry Es1dc1ControlEntry .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1 |
es1dc1ControlIndexThe Control entry Index Unsigned32 .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1.1 |
es1dc1ControlNameThe Control entry namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1.2 |
es1dc1ControlValueThe Control entry valuerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1.3 |
es1dc1ControlEntryStatusThe status of this table entry - not used, only for compliancerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.2.1.4 |
es1dc1ControlList OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3 |
es1dc1CtrlSystemBackToFloatThe dc system must go back in floating mode.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.1 |
es1dc1CtrlSystemStartBatTestThe dc system must start a battery test.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.2 |
es1dc1CtrlSystemForceBatTestThe dc system must force a battery test.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.3 |
es1dc1CtrlSystemStartBoostModeThe dc system must go in boost mode.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.4 |
es1dc1CtrlLVDOpenTheLVDTry to open the LVD. It could not work if the LVD is electronic, and the request will be canceled after 15 sec.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.11 |
es1dc1CtrlLVDCloseTheLVDThe LVD must be closedrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.12 |
es1dc1CtrlBatCorrectBatCurrentOffsetNArw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.21 |
es1dc1CtrlBatResetLastBatTestStateReset the state of the last battery test. If an alarm 'Battery Last Test Failed' is set, the alarm will be cleared.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.41 |
es1dc1CtrlSaveSaveConfInMCUSave configuration parameters in the MCU microcontroller. If comp@s is not present, the system will be correctly managed.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.51 |
es1dc1CtrlAdvancedSetMCUSpecificConfIdThis control allows to reconfigure the MCU to support specific hardware configuration, with embedded distribution for examplerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.55 |
es1dc1CtrlDigInputsSetDigInput4CounterValueSet Counter Valuerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.61 |
es1dc1CtrlRelsInvertRel1StateForXSecondsGenerate Pulse on relay 1rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.111 |
es1dc1CtrlRelsInvertRel2StateForXSecondsGenerate Pulse on relay 2rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.112 |
es1dc1CtrlRelsInvertRel3StateForXSecondsGenerate Pulse on relay 3rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.113 |
es1dc1CtrlRelsInvertRel4StateForXSecondsGenerate Pulse on relay 4rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.114 |
es1dc1CtrlGenericClearMyEventsBy writing '1' to this control element, all the events of this equipment will be cleared.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.501 |
es1dc1CtrlGenericClearAllEventsBy writing '1' to this control element, all the events of this equipment and all the events of all the sub-equipments will be cleared.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.502 |
es1dc1CtrlGenericAddEventThis control element adds an event of severity none. The event name is the text written to this control elementrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.511 |
es1dc1CtrlGenericAddMajorEventThis control element adds an event of severity major. The event name is the text written to this control elementrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.512 |
es1dc1CtrlGenericResetDefaultNamesAndGroupsThis control element resets all the element Names, Groups and Subgroups to default values for this equipmentrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.521 |
es1dc1CtrlGenericResetDefaultNamesAndGroupsRecursiveThis control element resets all the element Names, Groups and Subgroups to default values for this equipment and all sub equipmentsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.16.3.522 |
es1dc1Notifications OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.18 |
es1dc1NotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.18.0 |
es1dc1NotificationOfEventNotification generated when a new event appears NOTIFICATION-TYPE .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.18.0.1 |
es1dc1Compliance OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19 |
es1dc1ComplianceGroups OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19.1 |
es1dc1GlobalGrouptext Unknown .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19.1.1 |
es1dc1NotificationGrouptext Unknown .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19.1.2 |
es1dc1FullComplianceThe compliance statement for SNMPV2 entities which implement the SNMPV2 MIB. Unknown .1.3.6.1.4.1.26854.3.2.1.20.1.20.1.19.2 |
es1InverterSystems OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.25 |
es1RemotePowerFeedingSystems OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.20.1.28 |
extensions OBJECT IDENTIFIER .1.3.6.1.4.1.26854.3.2.1.21 |