Argus-MIB
AI MIB Summary
The Argus-MIB facilitates SNMP monitoring of SM-series system controllers, specifically exposing the `dcPwrSysDevice` information block to track DC power system status and device health metrics.
This MIB defines the information block(s) available in system controllers as defined by the following list: - dcPwrSysDevice: the SM-series of controllers
Main OID:
argus.1.3.6.1.4.1.7309
217
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
217 total| Object Name |
|---|
argusThis MIB defines the information block(s) available in system controllers as defined by the following list: - dcPwrSysDevice: the SM-series of controllers MODULE-IDENTITY .1.3.6.1.4.1.7309 |
dcpower OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4 |
dcPwrSysDevice OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1 |
dcPwrSysVariable OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.1 |
dcPwrSysChargeVoltsBattery Charge Voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Voltro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.1.1 |
dcPwrSysDischargeVoltsBattery Discharge Voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Voltro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.1.2 |
dcPwrSysChargeAmpsBattery Charge Current. The integer value represent a two digit fix decimal (Value = real current * 100) in Ampro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.1.3 |
dcPwrSysDischargeAmpsBattery Discharge Current. The integer value represent a two digit fix decimal (Value = real current * 100) in Ampro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.1.4 |
dcPwrSysMajorAlarmMajor Alarmro INTEGER .1.3.6.1.4.1.7309.4.1.1.5 |
dcPwrSysMinorAlarmMinor Alarmro INTEGER .1.3.6.1.4.1.7309.4.1.1.6 |
dcPwrSysString OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.2 |
dcPwrSysSiteNameSite Namero DisplayString .1.3.6.1.4.1.7309.4.1.2.1 |
dcPwrSysSiteCitySite Cityro DisplayString .1.3.6.1.4.1.7309.4.1.2.2 |
dcPwrSysSiteRegionSite Regionro DisplayString .1.3.6.1.4.1.7309.4.1.2.3 |
dcPwrSysSiteCountrySite Countryro DisplayString .1.3.6.1.4.1.7309.4.1.2.4 |
dcPwrSysContactNameContact Namero DisplayString .1.3.6.1.4.1.7309.4.1.2.5 |
dcPwrSysPhoneNumberPhone Numberro DisplayString .1.3.6.1.4.1.7309.4.1.2.6 |
dcPwrSysSiteNumberSite Numberro DisplayString .1.3.6.1.4.1.7309.4.1.2.7 |
dcPwrSysSystemTypeThe type of system being monitored by the agentro DisplayString .1.3.6.1.4.1.7309.4.1.2.8 |
dcPwrSysSystemSerialThe serial number of the monitored systemro DisplayString .1.3.6.1.4.1.7309.4.1.2.9 |
dcPwrSysSystemNumberThe number of the monitored systemro DisplayString .1.3.6.1.4.1.7309.4.1.2.10 |
dcPwrSysSoftwareVersionThe version of software running on the monitored systemro DisplayString .1.3.6.1.4.1.7309.4.1.2.11 |
dcPwrSysSoftwareTimestampThe time stamp of the software running on the monitored systemro DisplayString .1.3.6.1.4.1.7309.4.1.2.12 |
dcPwrSysTraps OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.3 |
dcPwrSysTrap OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.3.0 |
dcPwrSysAlarmActiveTrapA trap issued when one of the alarms on the DC power system controller became active NOTIFICATION-TYPE .1.3.6.1.4.1.7309.4.1.3.0.1 |
dcPwrSysAlarmClearedTrapA trap issued when one of the active alarms on the DC power system controller is cleared NOTIFICATION-TYPE .1.3.6.1.4.1.7309.4.1.3.0.2 |
dcPwrSysRelayTrapA trap issued from a change in state in one of the relays on the DC power system controller NOTIFICATION-TYPE .1.3.6.1.4.1.7309.4.1.3.0.3 |
dcPwrSysComOKTrapA trap to indicate that communications with a DC power system controller has been established. NOTIFICATION-TYPE .1.3.6.1.4.1.7309.4.1.3.0.4 |
dcPwrSysComErrTrapA trap to indicate that communications with a DC power system controller has been lost. NOTIFICATION-TYPE .1.3.6.1.4.1.7309.4.1.3.0.5 |
dcPwrSysAgentStartupTrapA trap to indicate that the agent software has started up. NOTIFICATION-TYPE .1.3.6.1.4.1.7309.4.1.3.0.6 |
dcPwrSysAgentShutdownTrapA trap to indicate that the agent software has shutdown. NOTIFICATION-TYPE .1.3.6.1.4.1.7309.4.1.3.0.7 |
dcPwrSysMajorAlarmActiveTrapA trap issued as a summary of DC power system status. It is sent when the system goes into in Major Alarm NOTIFICATION-TYPE .1.3.6.1.4.1.7309.4.1.3.0.8 |
dcPwrSysMajorAlarmClearedTrapA trap issued as a summary of DC power system status. It is sent when the system comes out of Major Alarm NOTIFICATION-TYPE .1.3.6.1.4.1.7309.4.1.3.0.9 |
dcPwrSysMinorAlarmActiveTrapA trap issued as a summary of DC power system status. It is sent when the system goes into in Minor Alarm NOTIFICATION-TYPE .1.3.6.1.4.1.7309.4.1.3.0.10 |
dcPwrSysMinorAlarmClearedTrapA trap issued as a summary of DC power system status. It is sent when the system comes out of Minor Alarm NOTIFICATION-TYPE .1.3.6.1.4.1.7309.4.1.3.0.11 |
dcPwrSysOutputsTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.4 |
dcPwrSysRelayTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.4.1 |
dcPwrSysRelayCountNumber of relay variables in system controller relay tablero INTEGER .1.3.6.1.4.1.7309.4.1.4.1.1 |
dcPwrSysRelayTableA table of DC power system controller rectifier relay output variables SEQUENCE OF DcPwrSysRelayEntry .1.3.6.1.4.1.7309.4.1.4.1.2 |
dcPwrSysRelayEntryAn entry into the DC power system controller relay output group DcPwrSysRelayEntry .1.3.6.1.4.1.7309.4.1.4.1.2.1 |
dcPwrSysRelayIndexThe index of the relay variable in the power system controller relay output groupro INTEGER .1.3.6.1.4.1.7309.4.1.4.1.2.1.1 |
dcPwrSysRelayNameThe description of the relay variable as reported by the DC power system controller relay output groupro DisplayString .1.3.6.1.4.1.7309.4.1.4.1.2.1.2 |
dcPwrSysRelayIntegerValueThe integer value of the relay variable as reported by the DC power system controller relay output groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.4.1.2.1.3 |
dcPwrSysRelayStringValueThe string value of the relay variable as reported by the DC power system controller relay output groupro DisplayString .1.3.6.1.4.1.7309.4.1.4.1.2.1.4 |
dcPwrSysRelaySeverityThe integer value of relay severity level of the extra variable as reported by the DC power system controller relay output groupro INTEGER .1.3.6.1.4.1.7309.4.1.4.1.2.1.5 |
dcPwrSysAnalogOpTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.4.2 |
dcPwrSysAnalogOpCountNumber of analog output variables in system controller analog output tablero INTEGER .1.3.6.1.4.1.7309.4.1.4.2.1 |
dcPwrSysAnalogOpTableA table of DC power system controller analog output variables SEQUENCE OF DcPwrSysAnalogOpEntry .1.3.6.1.4.1.7309.4.1.4.2.2 |
dcPwrSysAnalogOpEntryAn entry into the DC power system controller analog output group DcPwrSysAnalogOpEntry .1.3.6.1.4.1.7309.4.1.4.2.2.1 |
dcPwrSysAnalogOpIndexThe index of the analog variable in the power system controller analog output groupro INTEGER .1.3.6.1.4.1.7309.4.1.4.2.2.1.1 |
dcPwrSysAnalogOpNameThe description of the analog variable as reported by the DC power system controller analog output groupro DisplayString .1.3.6.1.4.1.7309.4.1.4.2.2.1.2 |
dcPwrSysAnalogOpIntegerValueThe integer value of the analog variable as reported by the DC power system controller analog output groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.4.2.2.1.3 |
dcPwrSysAnalogOpStringValueThe string value of the analog variable as reported by the DC power system controller analog output groupro DisplayString .1.3.6.1.4.1.7309.4.1.4.2.2.1.4 |
dcPwrSysAnalogOpSeverityThe integer value of analog severity level of the extra variable as reported by the DC power system controller analog output groupro INTEGER .1.3.6.1.4.1.7309.4.1.4.2.2.1.5 |
dcPwrSysAlrmsTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.5 |
dcPwrSysRectAlrmTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.5.1 |
dcPwrSysRectAlrmCountNumber of rectifier alarm variables in system controller alarm tablero INTEGER .1.3.6.1.4.1.7309.4.1.5.1.1 |
dcPwrSysRectAlrmTableA table of DC power system controller rectifier alarm variables SEQUENCE OF DcPwrSysRectAlrmEntry .1.3.6.1.4.1.7309.4.1.5.1.2 |
dcPwrSysRectAlrmEntryAn entry into the DC power system controller rectifier alarm group DcPwrSysRectAlrmEntry .1.3.6.1.4.1.7309.4.1.5.1.2.1 |
dcPwrSysRectAlrmIndexThe index of the alarm variable in the DC power system controller table rectifier alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.1.2.1.1 |
dcPwrSysRectAlrmNameThe description of the alarm variable as reported by the DC power system controller rectifier alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.1.2.1.2 |
dcPwrSysRectAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller rectifier alarm groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.5.1.2.1.3 |
dcPwrSysRectAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller rectifier alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.1.2.1.4 |
dcPwrSysRectAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller rectifier alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.1.2.1.5 |
dcPwrSysDigAlrmTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.5.2 |
dcPwrSysDigAlrmCountNumber of digital alarm variables in system controller alarm tablero INTEGER .1.3.6.1.4.1.7309.4.1.5.2.1 |
dcPwrSysDigAlrmTableA table of DC power system controller digital alarm variables SEQUENCE OF DcPwrSysDigAlrmEntry .1.3.6.1.4.1.7309.4.1.5.2.2 |
dcPwrSysDigAlrmEntryAn entry into the DC power system controller digital alarm group DcPwrSysDigAlrmEntry .1.3.6.1.4.1.7309.4.1.5.2.2.1 |
dcPwrSysDigAlrmIndexThe index of the alarm variable in the DC power system controller table digital alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.2.2.1.1 |
dcPwrSysDigAlrmNameThe description of the alarm variable as reported by the DC power system controller digital alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.2.2.1.2 |
dcPwrSysDigAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller digital alarm groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.5.2.2.1.3 |
dcPwrSysDigAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller digital alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.2.2.1.4 |
dcPwrSysDigAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller digital alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.2.2.1.5 |
dcPwrSysCurrAlrmTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.5.3 |
dcPwrSysCurrAlrmCountNumber of current alarm variables in system controller alarm tablero INTEGER .1.3.6.1.4.1.7309.4.1.5.3.1 |
dcPwrSysCurrAlrmTableA table of DC power system controller current alarm variables SEQUENCE OF DcPwrSysCurrAlrmEntry .1.3.6.1.4.1.7309.4.1.5.3.2 |
dcPwrSysCurrAlrmEntryAn entry into the DC power system controller current alarm group DcPwrSysCurrAlrmEntry .1.3.6.1.4.1.7309.4.1.5.3.2.1 |
dcPwrSysCurrAlrmIndexThe index of the alarm variable in the DC power system controller table current alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.3.2.1.1 |
dcPwrSysCurrAlrmNameThe description of the alarm variable as reported by the DC power system controller current alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.3.2.1.2 |
dcPwrSysCurrAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller current alarm groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.5.3.2.1.3 |
dcPwrSysCurrAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller current alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.3.2.1.4 |
dcPwrSysCurrAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller current alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.3.2.1.5 |
dcPwrSysVoltAlrmTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.5.4 |
dcPwrSysVoltAlrmCountNumber of voltage alarm variables in system controller alarm tablero INTEGER .1.3.6.1.4.1.7309.4.1.5.4.1 |
dcPwrSysVoltAlrmTableA table of DC power system controller voltage alarm variables SEQUENCE OF DcPwrSysVoltAlrmEntry .1.3.6.1.4.1.7309.4.1.5.4.2 |
dcPwrSysVoltAlrmEntryAn entry into the DC power system controller voltage alarm group DcPwrSysVoltAlrmEntry .1.3.6.1.4.1.7309.4.1.5.4.2.1 |
dcPwrSysVoltAlrmIndexThe index of the alarm variable in the DC power system controller table voltage alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.4.2.1.1 |
dcPwrSysVoltAlrmNameThe description of the alarm variable as reported by the DC power system controller voltage alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.4.2.1.2 |
dcPwrSysVoltAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller voltage alarm groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.5.4.2.1.3 |
dcPwrSysVoltAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller voltage alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.4.2.1.4 |
dcPwrSysVoltAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller voltage alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.4.2.1.5 |
dcPwrSysBattAlrmTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.5.5 |
dcPwrSysBattAlrmCountNumber of battery alarm variables in system controller alarm tablero INTEGER .1.3.6.1.4.1.7309.4.1.5.5.1 |
dcPwrSysBattAlrmTableA table of DC power system controller battery alarm variables SEQUENCE OF DcPwrSysBattAlrmEntry .1.3.6.1.4.1.7309.4.1.5.5.2 |
dcPwrSysBattAlrmEntryAn entry into the DC power system controller battery alarm group DcPwrSysBattAlrmEntry .1.3.6.1.4.1.7309.4.1.5.5.2.1 |
dcPwrSysBattAlrmIndexThe index of the alarm variable in the DC power system controller table battery alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.5.2.1.1 |
dcPwrSysBattAlrmNameThe description of the alarm variable as reported by the DC power system controller battery alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.5.2.1.2 |
dcPwrSysBattAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller battery alarm groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.5.5.2.1.3 |
dcPwrSysBattAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller battery alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.5.2.1.4 |
dcPwrSysBattAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller battery alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.5.2.1.5 |
dcPwrSysTempAlrmTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.5.6 |
dcPwrSysTempAlrmCountNumber of temperature alarm variables in system controller alarm tablero INTEGER .1.3.6.1.4.1.7309.4.1.5.6.1 |
dcPwrSysTempAlrmTableA table of DC power system controller temperature alarm variables SEQUENCE OF DcPwrSysTempAlrmEntry .1.3.6.1.4.1.7309.4.1.5.6.2 |
dcPwrSysTempAlrmEntryAn entry into the DC power system controller temperature alarm group DcPwrSysTempAlrmEntry .1.3.6.1.4.1.7309.4.1.5.6.2.1 |
dcPwrSysTempAlrmIndexThe index of the alarm variable in the DC power system controller table temperature alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.6.2.1.1 |
dcPwrSysTempAlrmNameThe description of the alarm variable as reported by the DC power system controller temperature alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.6.2.1.2 |
dcPwrSysTempAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller temperature alarm groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.5.6.2.1.3 |
dcPwrSysTempAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller temperature alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.6.2.1.4 |
dcPwrSysTempAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller temperature alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.6.2.1.5 |
dcPwrSysCustomAlrmTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.5.7 |
dcPwrSysCustomAlrmCountNumber of custom alarm variables in system controller alarm tablero INTEGER .1.3.6.1.4.1.7309.4.1.5.7.1 |
dcPwrSysCustomAlrmTableA table of DC power system controller custom alarm variables SEQUENCE OF DcPwrSysCustomAlrmEntry .1.3.6.1.4.1.7309.4.1.5.7.2 |
dcPwrSysCustomAlrmEntryAn entry into the DC power system controller custom alarm group DcPwrSysCustomAlrmEntry .1.3.6.1.4.1.7309.4.1.5.7.2.1 |
dcPwrSysCustomAlrmIndexThe index of the alarm variable in the DC power system controller table custom alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.7.2.1.1 |
dcPwrSysCustomAlrmNameThe description of the alarm variable as reported by the DC power system controller custom alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.7.2.1.2 |
dcPwrSysCustomAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller custom alarm groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.5.7.2.1.3 |
dcPwrSysCustomAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller custom alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.7.2.1.4 |
dcPwrSysCustomAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller custom alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.7.2.1.5 |
dcPwrSysMiscAlrmTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.5.8 |
dcPwrSysMiscAlrmCountNumber of misc alarm variables in system controller alarm tablero INTEGER .1.3.6.1.4.1.7309.4.1.5.8.1 |
dcPwrSysMiscAlrmTableA table of DC power system controller misc alarm variables SEQUENCE OF DcPwrSysMiscAlrmEntry .1.3.6.1.4.1.7309.4.1.5.8.2 |
dcPwrSysMiscAlrmEntryAn entry into the DC power system controller misc alarm group DcPwrSysMiscAlrmEntry .1.3.6.1.4.1.7309.4.1.5.8.2.1 |
dcPwrSysMiscAlrmIndexThe index of the alarm variable in the DC power system controller table misc alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.8.2.1.1 |
dcPwrSysMiscAlrmNameThe description of the alarm variable as reported by the DC power system controller misc alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.8.2.1.2 |
dcPwrSysMiscAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller misc alarm groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.5.8.2.1.3 |
dcPwrSysMiscAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller misc alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.8.2.1.4 |
dcPwrSysMiscAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller misc alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.8.2.1.5 |
dcPwrSysCtrlAlrmTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.5.9 |
dcPwrSysCtrlAlrmCountNumber of control alarm variables in system controller alarm tablero INTEGER .1.3.6.1.4.1.7309.4.1.5.9.1 |
dcPwrSysCtrlAlrmTableA table of DC power system controller control alarm variables SEQUENCE OF DcPwrSysCtrlAlrmEntry .1.3.6.1.4.1.7309.4.1.5.9.2 |
dcPwrSysCtrlAlrmEntryAn entry into the DC power system controller control alarm group DcPwrSysCtrlAlrmEntry .1.3.6.1.4.1.7309.4.1.5.9.2.1 |
dcPwrSysCtrlAlrmIndexThe index of the alarm variable in the DC power system controller table control alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.9.2.1.1 |
dcPwrSysCtrlAlrmNameThe description of the alarm variable as reported by the DC power system controller control alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.9.2.1.2 |
dcPwrSysCtrlAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller control alarm groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.5.9.2.1.3 |
dcPwrSysCtrlAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller control alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.9.2.1.4 |
dcPwrSysCtrlAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller control alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.9.2.1.5 |
dcPwrSysAdioAlrmTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.5.10 |
dcPwrSysAdioAlrmCountNumber of control alarm variables in Adio alarm tablero INTEGER .1.3.6.1.4.1.7309.4.1.5.10.1 |
dcPwrSysAdioAlrmTableA table of DC power system controller Adio alarm variables SEQUENCE OF DcPwrSysAdioAlrmEntry .1.3.6.1.4.1.7309.4.1.5.10.2 |
dcPwrSysAdioAlrmEntryAn entry into the DC power system controller Adio alarm group DcPwrSysAdioAlrmEntry .1.3.6.1.4.1.7309.4.1.5.10.2.1 |
dcPwrSysAdioAlrmIndexThe index of the alarm variable in the DC power system controller table Adio alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.10.2.1.1 |
dcPwrSysAdioAlrmNameThe description of the alarm variable as reported by the DC power system controller Adio alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.10.2.1.2 |
dcPwrSysAdioAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller Adio alarm groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.5.10.2.1.3 |
dcPwrSysAdioAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller Adio alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.10.2.1.4 |
dcPwrSysAdioAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC Adio system controller control alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.10.2.1.5 |
dcPwrSysConvAlrmTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.5.11 |
dcPwrSysConvAlrmCountNumber of Converter alarm variables in system controller alarm tablero INTEGER .1.3.6.1.4.1.7309.4.1.5.11.1 |
dcPwrSysConvAlrmTableA table of DC power system controller Converter alarm variables SEQUENCE OF DcPwrSysConvAlrmEntry .1.3.6.1.4.1.7309.4.1.5.11.2 |
dcPwrSysConvAlrmEntryAn entry into the DC power system controller Converter alarm group DcPwrSysConvAlrmEntry .1.3.6.1.4.1.7309.4.1.5.11.2.1 |
dcPwrSysConvAlrmIndexThe index of the alarm variable in the DC power system controller table Converter alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.11.2.1.1 |
dcPwrSysConvAlrmNameThe description of the alarm variable as reported by the DC power system controller Converter alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.11.2.1.2 |
dcPwrSysConvAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller Converter alarm groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.5.11.2.1.3 |
dcPwrSysConvAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller Converter alarm groupro DisplayString .1.3.6.1.4.1.7309.4.1.5.11.2.1.4 |
dcPwrSysConvAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller Converter alarm groupro INTEGER .1.3.6.1.4.1.7309.4.1.5.11.2.1.5 |
dcPwrSysInputsTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.6 |
dcPwrSysDigIpTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.6.1 |
dcPwrSysDigIpCountNumber of digital input variables in system controller digital input tablero INTEGER .1.3.6.1.4.1.7309.4.1.6.1.1 |
dcPwrSysDigIpTableA table of DC power system controller digital input variables SEQUENCE OF DcPwrSysDigIpEntry .1.3.6.1.4.1.7309.4.1.6.1.2 |
dcPwrSysDigIpEntryAn entry into the DC power system controller digital input group DcPwrSysDigIpEntry .1.3.6.1.4.1.7309.4.1.6.1.2.1 |
dcPwrSysDigIpIndexThe index of the digital input variable in the DC power system controller table digital input groupro INTEGER .1.3.6.1.4.1.7309.4.1.6.1.2.1.1 |
dcPwrSysDigIpNameThe description of the digital input variable as reported by the DC power system controller digital input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.1.2.1.2 |
dcPwrSysDigIpIntegerValueThe integer value of the digital input variable as reported by the DC power system controller digital input groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.6.1.2.1.3 |
dcPwrSysDigIpStringValueThe string value of the digital input variable as reported by the DC power system controller digital input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.1.2.1.4 |
dcPwrSysCntrlrIpTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.6.2 |
dcPwrSysCntrlrIpCountNumber of controller input variables in system controller controller input tablero INTEGER .1.3.6.1.4.1.7309.4.1.6.2.1 |
dcPwrSysCntrlrIpTableA table of DC power system controller controller input variables SEQUENCE OF DcPwrSysCntrlrIpEntry .1.3.6.1.4.1.7309.4.1.6.2.2 |
dcPwrSysCntrlrIpEntryAn entry into the DC power system controller controller input group DcPwrSysCntrlrIpEntry .1.3.6.1.4.1.7309.4.1.6.2.2.1 |
dcPwrSysCntrlrIpIndexThe index of the controller input variable in the DC power system controller table controller input groupro INTEGER .1.3.6.1.4.1.7309.4.1.6.2.2.1.1 |
dcPwrSysCntrlrIpNameThe description of the controller input variable as reported by the DC power system controller controller input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.2.2.1.2 |
dcPwrSysCntrlrIpIntegerValueThe integer value of the controller input variable as reported by the DC power system controller controller input groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.6.2.2.1.3 |
dcPwrSysCntrlrIpStringValueThe string value of the controller input variable as reported by the DC power system controller controller input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.2.2.1.4 |
dcPwrSysRectIpTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.6.3 |
dcPwrSysRectIpCountNumber of rectifier input variables in system controller rectifier input tablero INTEGER .1.3.6.1.4.1.7309.4.1.6.3.1 |
dcPwrSysRectIpTableA table of DC power system controller rectifier input variables SEQUENCE OF DcPwrSysRectIpEntry .1.3.6.1.4.1.7309.4.1.6.3.2 |
dcPwrSysRectIpEntryAn entry into the DC power system controller rectifier input group DcPwrSysRectIpEntry .1.3.6.1.4.1.7309.4.1.6.3.2.1 |
dcPwrSysRectIpIndexThe index of the rectifier input variable in the DC power system controller table rectifier input groupro INTEGER .1.3.6.1.4.1.7309.4.1.6.3.2.1.1 |
dcPwrSysRectIpNameThe description of the rectifier input variable as reported by the DC power system controller rectifier input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.3.2.1.2 |
dcPwrSysRectIpIntegerValueThe integer value of the rectifier input variable as reported by the DC power system controller rectifier input groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.6.3.2.1.3 |
dcPwrSysRectIpStringValueThe string value of the rectifier input variable as reported by the DC power system controller rectifier input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.3.2.1.4 |
dcPwrSysCustomIpTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.6.4 |
dcPwrSysCustomIpCountNumber of custom input variables in system controller custom input tablero INTEGER .1.3.6.1.4.1.7309.4.1.6.4.1 |
dcPwrSysCustomIpTableA table of DC power system controller digital custom variables SEQUENCE OF DcPwrSysCustomIpEntry .1.3.6.1.4.1.7309.4.1.6.4.2 |
dcPwrSysCustomIpEntryAn entry into the DC power system controller custom input group DcPwrSysCustomIpEntry .1.3.6.1.4.1.7309.4.1.6.4.2.1 |
dcPwrSysCustomIpIndexThe index of the custom input variable in the DC power system controller table custom input groupro INTEGER .1.3.6.1.4.1.7309.4.1.6.4.2.1.1 |
dcPwrSysCustomIpNameThe description of the custom input variable as reported by the DC power system controller custom input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.4.2.1.2 |
dcPwrSysgCustomIpIntegerValueThe integer value of the custom input variable as reported by the DC power system controller custom input groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.6.4.2.1.3 |
dcPwrSysCustomIpStringValueThe string value of the custom input variable as reported by the DC power system controller custom input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.4.2.1.4 |
dcPwrSysConvIpTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.6.5 |
dcPwrSysConvIpCountNumber of Converter input variables in system controller Converter input tablero INTEGER .1.3.6.1.4.1.7309.4.1.6.5.1 |
dcPwrSysConvIpTableA table of DC power system controller Converter input variables SEQUENCE OF DcPwrSysConvIpEntry .1.3.6.1.4.1.7309.4.1.6.5.2 |
dcPwrSysConvIpEntryAn entry into the DC power system controller Converter input group DcPwrSysConvIpEntry .1.3.6.1.4.1.7309.4.1.6.5.2.1 |
dcPwrSysConvIpIndexThe index of the Converter input variable in the DC power system controller table Converter input groupro INTEGER .1.3.6.1.4.1.7309.4.1.6.5.2.1.1 |
dcPwrSysConvIpNameThe description of the Converter input variable as reported by the DC power system controller Converter input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.5.2.1.2 |
dcPwrSysConvIpIntegerValueThe integer value of the Converter input variable as reported by the DC power system controller Converter input groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.6.5.2.1.3 |
dcPwrSysConvIpStringValueThe string value of the Converter input variable as reported by the DC power system controller Converter input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.5.2.1.4 |
dcPwrSysTimerIpTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.6.6 |
dcPwrSysTimerIpCountNumber of Timererter input variables in system controller Timererter input tablero INTEGER .1.3.6.1.4.1.7309.4.1.6.6.1 |
dcPwrSysTimerIpTableA table of DC power system controller Timererter input variables SEQUENCE OF DcPwrSysTimerIpEntry .1.3.6.1.4.1.7309.4.1.6.6.2 |
dcPwrSysTimerIpEntryAn entry into the DC power system controller Timererter input group DcPwrSysTimerIpEntry .1.3.6.1.4.1.7309.4.1.6.6.2.1 |
dcPwrSysTimerIpIndexThe index of the Timererter input variable in the DC power system controller table Timererter input groupro INTEGER .1.3.6.1.4.1.7309.4.1.6.6.2.1.1 |
dcPwrSysTimerIpNameThe description of the Timererter input variable as reported by the DC power system controller Timererter input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.6.2.1.2 |
dcPwrSysTimerIpIntegerValueThe integer value of the Timererter input variable as reported by the DC power system controller Timererter input groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.6.6.2.1.3 |
dcPwrSysTimerIpStringValueThe string value of the Timererter input variable as reported by the DC power system controller Timererter input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.6.2.1.4 |
dcPwrSysCounterIpTbl OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.6.7 |
dcPwrSysCounterIpCountNumber of Countererter input variables in system controller Countererter input tablero INTEGER .1.3.6.1.4.1.7309.4.1.6.7.1 |
dcPwrSysCounterIpTableA table of DC power system controller Countererter input variables SEQUENCE OF DcPwrSysCounterIpEntry .1.3.6.1.4.1.7309.4.1.6.7.2 |
dcPwrSysCounterIpEntryAn entry into the DC power system controller Countererter input group DcPwrSysCounterIpEntry .1.3.6.1.4.1.7309.4.1.6.7.2.1 |
dcPwrSysCounterIpIndexThe index of the Countererter input variable in the DC power system controller table Countererter input groupro INTEGER .1.3.6.1.4.1.7309.4.1.6.7.2.1.1 |
dcPwrSysCounterIpNameThe description of the Countererter input variable as reported by the DC power system controller Countererter input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.7.2.1.2 |
dcPwrSysCounterIpIntegerValueThe integer value of the Countererter input variable as reported by the DC power system controller Countererter input groupro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.4.1.6.7.2.1.3 |
dcPwrSysCounterIpStringValueThe string value of the Countererter input variable as reported by the DC power system controller Countererter input groupro DisplayString .1.3.6.1.4.1.7309.4.1.6.7.2.1.4 |
dcPwrExternalControls OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.8 |
dcPwrSysResyncAlarmsSend/Resend all active alarms that were previously sent through SNMP notification.rw INTEGER .1.3.6.1.4.1.7309.4.1.8.1 |
dcPwrVarbindNameReference OBJECT IDENTIFIER .1.3.6.1.4.1.7309.4.1.9 |
dcPwrSysAlarmTriggerValuero INTEGER .1.3.6.1.4.1.7309.4.1.9.1 |
dcPwrSysTimeStampro DisplayString .1.3.6.1.4.1.7309.4.1.9.2 |