Argus-Power-System-MIB
AI MIB Summary
The Argus-Power-System-MIB facilitates SNMP monitoring of CXC-series RMU controllers, specifically exposing the `upsDevice` information block to track Uninterruptible Power Supply (UPS) status, battery conditions, and power system health metrics.
This MIB defines the information block(s) available in CXC RMU as defined by the following list: - upsDevice: the CXC-series of controllers
Main OID:
argus.1.3.6.1.4.1.7309
81
Objects
Active
Status
1
Dependencies
Imported Objects
Objects
81 total| Object Name |
|---|
argusThis MIB defines the information block(s) available in CXC RMU as defined by the following list: - upsDevice: the CXC-series of controllers MODULE-IDENTITY .1.3.6.1.4.1.7309 |
upsPower OBJECT IDENTIFIER .1.3.6.1.4.1.7309.6 |
upsDevice OBJECT IDENTIFIER .1.3.6.1.4.1.7309.6.1 |
upsIdent OBJECT IDENTIFIER .1.3.6.1.4.1.7309.6.1.1 |
upsIdentManufacturerThe name of the UPS manufacturer.ro DisplayString .1.3.6.1.4.1.7309.6.1.1.1 |
upsIdentProductCodeThe UPS Model designation.ro DisplayString .1.3.6.1.4.1.7309.6.1.1.2 |
upsIdentModelThe UPS Product code designation.ro DisplayString .1.3.6.1.4.1.7309.6.1.1.3 |
upsIdentUPSSoftwareVersionThe UPS firmware/software version(s). This variable may or may not have the same value as upsIdentAgentSoftwareVersion in some implementations.ro DisplayString .1.3.6.1.4.1.7309.6.1.1.4 |
upsIdentAgentSoftwareVersionThe UPS agent software version. This variable may or may not have the same value as upsIdentUPSSoftwareVersion in some implementations.ro DisplayString .1.3.6.1.4.1.7309.6.1.1.5 |
upsIdentNameA string identifying the UPS. This object should be set by the administrator.ro DisplayString .1.3.6.1.4.1.7309.6.1.1.6 |
upsIdentAttachedDevicesA string identifying the devices attached to the output(s) of the UPS. This object should be set by the administrator.ro DisplayString .1.3.6.1.4.1.7309.6.1.1.7 |
upsIdentSiteNameSite Namerw DisplayString .1.3.6.1.4.1.7309.6.1.1.8 |
upsIdentSiteCitySite Cityrw DisplayString .1.3.6.1.4.1.7309.6.1.1.9 |
upsIdentSiteRegionSite Regionrw DisplayString .1.3.6.1.4.1.7309.6.1.1.10 |
upsIdentSiteCountrySite Countryrw DisplayString .1.3.6.1.4.1.7309.6.1.1.11 |
upsIdentContactNameContact Namerw DisplayString .1.3.6.1.4.1.7309.6.1.1.12 |
upsIdentPhoneNumberPhone Numberrw DisplayString .1.3.6.1.4.1.7309.6.1.1.13 |
upsIdentDateDate of the RMU-Novusrw DisplayString .1.3.6.1.4.1.7309.6.1.1.14 |
upsIdentTimeTime of the RMU-Novusrw DisplayString .1.3.6.1.4.1.7309.6.1.1.15 |
upsBattery OBJECT IDENTIFIER .1.3.6.1.4.1.7309.6.1.2 |
upsBatteryStatusThe indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than upsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to upsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).ro Enumeration .1.3.6.1.4.1.7309.6.1.2.1 |
upsMinutesOnBatteryThe accumulated elapsed time that the UPS system have been on battery.ro INTEGER UNITS "minutes" .1.3.6.1.4.1.7309.6.1.2.2 |
upsBatteryVoltageThe magnitude of the present battery voltage.ro INTEGER UNITS "0.1 Volt DC" .1.3.6.1.4.1.7309.6.1.2.3 |
upsBatteryChargingCurrentThe present battery charging current.ro INTEGER UNITS "0.1 Amp DC" .1.3.6.1.4.1.7309.6.1.2.4 |
upsBatteryCapacityThe present battery capacity.ro INTEGER UNITS "0.1 Amp DC" .1.3.6.1.4.1.7309.6.1.2.5 |
upsBatteryTemperatureThe ambient temperature at or near the UPS Battery casing.ro INTEGER UNITS "degrees Centigrade" .1.3.6.1.4.1.7309.6.1.2.6 |
upsBatteryLowWarningThe set battery capacity percentage at which the unit will raise an alarm.rw INTEGER UNITS "percentage" .1.3.6.1.4.1.7309.6.1.2.7 |
upsInput OBJECT IDENTIFIER .1.3.6.1.4.1.7309.6.1.3 |
upsInputNumLinesThe number of input lines utilized in this device. This variable indicates the number of rows in the input table.ro INTEGER .1.3.6.1.4.1.7309.6.1.3.1 |
upsInputTableA list of input table entries. The number of entries is given by the value of upsInputNumLines. SEQUENCE OF UpsInputEntry .1.3.6.1.4.1.7309.6.1.3.2 |
upsInputEntryAn entry containing information applicable to a particular input line. UpsInputEntry .1.3.6.1.4.1.7309.6.1.3.2.1 |
upsInputLineIndexThe input line identifier. INTEGER .1.3.6.1.4.1.7309.6.1.3.2.1.1 |
upsInputFrequencyThe present input frequency.ro INTEGER UNITS "Hertz" .1.3.6.1.4.1.7309.6.1.3.2.1.2 |
upsInputVoltageThe magnitude of the present input voltage.ro INTEGER UNITS "0.1 RMS Volts" .1.3.6.1.4.1.7309.6.1.3.2.1.3 |
upsOutput OBJECT IDENTIFIER .1.3.6.1.4.1.7309.6.1.4 |
upsOutputSourceThe present source of output power. The enumeration line(2) indicates that the Novus is in line mode.ro Enumeration .1.3.6.1.4.1.7309.6.1.4.1 |
upsOutputFrequencyThe present output frequency.ro INTEGER UNITS "0.1 Hertz" .1.3.6.1.4.1.7309.6.1.4.2 |
upsOutputNumLinesThe number of output lines utilized in this device. This variable indicates the number of rows in the output table.ro INTEGER .1.3.6.1.4.1.7309.6.1.4.3 |
upsOutputTableA list of output table entries. The number of entries is given by the value of upsOutputNumLines. SEQUENCE OF UpsOutputEntry .1.3.6.1.4.1.7309.6.1.4.4 |
upsOutputEntryAn entry containing information applicable to a particular output line. UpsOutputEntry .1.3.6.1.4.1.7309.6.1.4.4.1 |
upsOutputLineIndexThe output line identifier. INTEGER .1.3.6.1.4.1.7309.6.1.4.4.1.1 |
upsOutputVoltageThe present output voltage.ro INTEGER UNITS "0.1 RMS Volts" .1.3.6.1.4.1.7309.6.1.4.4.1.2 |
upsOutputCurrentThe present output current.ro INTEGER UNITS "0.1 RMS Amp" .1.3.6.1.4.1.7309.6.1.4.4.1.3 |
upsOutputPowerVAThe present output VA.ro INTEGER UNITS "VA" .1.3.6.1.4.1.7309.6.1.4.4.1.4 |
upsOutputPowerWattThe present output true power.ro INTEGER UNITS "Watts" .1.3.6.1.4.1.7309.6.1.4.4.1.5 |
upsPowerFactorThe present power factor.ro INTEGER UNITS "percent" .1.3.6.1.4.1.7309.6.1.4.4.1.6 |
upsOutputPercentLoadThe percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.ro INTEGER .1.3.6.1.4.1.7309.6.1.4.4.1.7 |
upsAlarm OBJECT IDENTIFIER .1.3.6.1.4.1.7309.6.1.5 |
upsAlarmsPresentThe present number of active alarm conditions.ro INTEGER .1.3.6.1.4.1.7309.6.1.5.1 |
upsAlarmTableA list of alarm table entries. SEQUENCE OF UpsAlarmEntry .1.3.6.1.4.1.7309.6.1.5.2 |
upsAlarmEntryAn entry containing information applicable to a particular alarm. UpsAlarmEntry .1.3.6.1.4.1.7309.6.1.5.2.1 |
upsAlarmIdA unique identifier for an alarm condition. This value must remain constant. INTEGER .1.3.6.1.4.1.7309.6.1.5.2.1.1 |
upsAlarmDescrA unique description of the alarm.ro DisplayString .1.3.6.1.4.1.7309.6.1.5.2.1.2 |
upsAlarmStatus1 - ON or 0 - OFF.ro INTEGER .1.3.6.1.4.1.7309.6.1.5.2.1.3 |
upsConfig OBJECT IDENTIFIER .1.3.6.1.4.1.7309.6.1.6 |
upsConfigLineQualifyTimeThis objects displays the line qualify time.ro INTEGER UNITS "seconds" .1.3.6.1.4.1.7309.6.1.6.1 |
upsConfigLineOutputVoltageHighLimitThis object represents the Line output High Voltage Limit.ro INTEGER UNITS "volttenth" .1.3.6.1.4.1.7309.6.1.6.2 |
upsConfigLineOutputVoltageLowLimitThis object represents the Line output Low Voltage Limit.ro INTEGER UNITS "volttenth" .1.3.6.1.4.1.7309.6.1.6.3 |
upsConfigFanOnTemperatureThis object represents the Fan on temperature.ro INTEGER UNITS "degreeC" .1.3.6.1.4.1.7309.6.1.6.4 |
upsShutdownStatusThis object tells us if output is disabled or enabled.rw INTEGER UNITS "" .1.3.6.1.4.1.7309.6.1.6.5 |
upsInverterOffDelayTimeThis object represents the inverter off delay time.rw INTEGER UNITS "seconds" .1.3.6.1.4.1.7309.6.1.6.6 |
upsConfigIPAddressThis objects displays the IP address of the RMU.rw DisplayString .1.3.6.1.4.1.7309.6.1.6.7 |
upsConfigNetMaskThis object displays the Net Mask of the RMU.rw DisplayString .1.3.6.1.4.1.7309.6.1.6.8 |
upsConfigGatewayThis object displays the Gateway of the RMU.rw DisplayString .1.3.6.1.4.1.7309.6.1.6.9 |
upsConfigSnmpCommunityThis object displays the SNMP communityrw DisplayString .1.3.6.1.4.1.7309.6.1.6.10 |
upsConfigSnmpTrapIPDestinationThis object displays the SNMP Trap IP destination.rw DisplayString .1.3.6.1.4.1.7309.6.1.6.11 |
upsTraps OBJECT IDENTIFIER .1.3.6.1.4.1.7309.6.1.7 |
upsTrap OBJECT IDENTIFIER .1.3.6.1.4.1.7309.6.1.7.0 |
upsAlarmTrapA trap issued from a change in state in one of the Alarms on the Novus controller NOTIFICATION-TYPE .1.3.6.1.4.1.7309.6.1.7.0.1 |
upsAgentStartupTrapA trap to indicate that the agent software has started up. NOTIFICATION-TYPE .1.3.6.1.4.1.7309.6.1.7.0.2 |
upsAgentShutdownTrapA trap to indicate that the agent software has shutdown. NOTIFICATION-TYPE .1.3.6.1.4.1.7309.6.1.7.0.3 |
upsAgentFaultTrapA trap issued from a change in state in one of the Faults on the Novus controller NOTIFICATION-TYPE .1.3.6.1.4.1.7309.6.1.7.0.4 |
upsAgentEventTrapA trap issued from a change in state in one of the Events on the Novus controller NOTIFICATION-TYPE .1.3.6.1.4.1.7309.6.1.7.0.5 |
upsExtra OBJECT IDENTIFIER .1.3.6.1.4.1.7309.6.1.8 |
upsExtraCountNumber of extra variablesro INTEGER .1.3.6.1.4.1.7309.6.1.8.1 |
upsExtraTableA table of CXC upstem controller extra variables SEQUENCE OF UpsExtraEntry .1.3.6.1.4.1.7309.6.1.8.2 |
upsExtraEntryAn entry into the CXC upstem controller extra variable table UpsExtraEntry .1.3.6.1.4.1.7309.6.1.8.2.1 |
upsExtraIndexThe index of the extra variable in the CXC upstem controller tablero INTEGER .1.3.6.1.4.1.7309.6.1.8.2.1.1 |
upsExtraNameThe description of the extra variable as reported by the CXC upstem controllerro DisplayString .1.3.6.1.4.1.7309.6.1.8.2.1.2 |
upsExtraIntegerValueThe integer value of the extra variable as reported by the CXC upstem controllerro INTEGER (-1000000000..1000000000) .1.3.6.1.4.1.7309.6.1.8.2.1.3 |
upsExtraStringValueThe string value of the extra variable as reported by the CXC upstem controllerro DisplayString .1.3.6.1.4.1.7309.6.1.8.2.1.4 |