AlphaPowerSystem-MIB facilitates SNMP monitoring of DC power system devices within Cordex series controllers, specifically exposing the `dcPwrSysDevice` information block for tracking power subsystem status and operational parameters.

This MIB defines the information block(s) available in system controllers as defined by the following list: - dcPwrSysDevice: Cordex series of Controllers
Main OID:
alpha.1.3.6.1.4.1.7309
226
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

226 total
Object Name
alphaThis MIB defines the information block(s) available in system controllers as defined by the following list: - dcPwrSysDevice: Cordex series of Controllers
MODULE-IDENTITY
.1.3.6.1.4.1.7309
dcpower
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4
dcPwrSysDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1
dcPwrSysVariable
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.1
dcPwrSysChargeVoltsThis value indicates the present battery voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volts.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.1.1
dcPwrSysDischargeVoltsThis value indicates the present load voltage. The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volts.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.1.2
dcPwrSysChargeAmpsThis value indicates the present battery currrent. The integer value represent a two digit fix decimal (Value = real current * 100) in Amps.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.1.3
dcPwrSysDischargeAmpsThis value indicates the present load current. The integer value represent a two digit fix decimal (Value = real current * 100) in Amps.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.1.4
dcPwrSysMajorAlarmMajor Alarmro
INTEGER
.1.3.6.1.4.1.7309.4.1.1.5
dcPwrSysMinorAlarmMinor Alarmro
INTEGER
.1.3.6.1.4.1.7309.4.1.1.6
dcPwrSysString
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.2
dcPwrSysSiteNameSite Namero
DisplayString
.1.3.6.1.4.1.7309.4.1.2.1
dcPwrSysSiteCitySite Cityro
DisplayString
.1.3.6.1.4.1.7309.4.1.2.2
dcPwrSysSiteRegionSite Regionro
DisplayString
.1.3.6.1.4.1.7309.4.1.2.3
dcPwrSysSiteCountrySite Countryro
DisplayString
.1.3.6.1.4.1.7309.4.1.2.4
dcPwrSysContactNameContact Namero
DisplayString
.1.3.6.1.4.1.7309.4.1.2.5
dcPwrSysPhoneNumberPhone Numberro
DisplayString
.1.3.6.1.4.1.7309.4.1.2.6
dcPwrSysSiteNumberSite Numberro
DisplayString
.1.3.6.1.4.1.7309.4.1.2.7
dcPwrSysSystemTypeThe type of system being monitored by the agent.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.2.8
dcPwrSysSystemSerialThe serial number of the monitored system.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.2.9
dcPwrSysSystemNumberThe number of the monitored system.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.2.10
dcPwrSysSoftwareVersionThe version of software running on the monitored system.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.2.11
dcPwrSysSoftwareTimestampThe time stamp of the software running on the monitored system.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.2.12
dcPwrSysTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.3
dcPwrSysTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.3.0
dcPwrSysAlarmActiveTrapA trap issued when one of the alarms on the became active.
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.4.1.3.0.1
dcPwrSysAlarmClearedTrapA trap issued when one of the active alarms on the is cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.4.1.3.0.2
dcPwrSysRelayTrapA trap issued from a change in state in one of the relays on the DC power system controller.
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.4.1.3.0.3
dcPwrSysComOKTrapA trap to indicate that communications with a DC power system controller has been established.
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.4.1.3.0.4
dcPwrSysComErrTrapA trap to indicate that communications with a DC power system controller has been lost.
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.4.1.3.0.5
dcPwrSysAgentStartupTrapA trap to indicate that the agent software has started up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.4.1.3.0.6
dcPwrSysAgentShutdownTrapA trap to indicate that the agent software has shutdown.
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.4.1.3.0.7
dcPwrSysMajorAlarmActiveTrapA trap issued as a summary of DC power system status. It is sent when the system goes into in Major Alarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.4.1.3.0.8
dcPwrSysMajorAlarmClearedTrapA trap issued as a summary of DC power system status. It is sent when the system comes out of Major Alarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.4.1.3.0.9
dcPwrSysMinorAlarmActiveTrapA trap issued as a summary of DC power system status. It is sent when the system goes into in Minor Alarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.4.1.3.0.10
dcPwrSysMinorAlarmClearedTrapA trap issued as a summary of DC power system status. It is sent when the system comes out of Minor Alarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.7309.4.1.3.0.11
dcPwrSysOutputsTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.4
dcPwrSysRelayTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.4.1
dcPwrSysRelayCountNumber of relay variables in system controller relay table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.4.1.1
dcPwrSysRelayTableA table of DC power system controller rectifier relay output variables.
SEQUENCE OF DcPwrSysRelayEntry
.1.3.6.1.4.1.7309.4.1.4.1.2
dcPwrSysRelayEntryAn entry into the DC power system controller relay output group.
DcPwrSysRelayEntry
.1.3.6.1.4.1.7309.4.1.4.1.2.1
dcPwrSysRelayIndexThe index of the relay variable in the power system controller relay output group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.4.1.2.1.1
dcPwrSysRelayNameThe description of the relay variable as reported by the DC power system controller relay output group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.4.1.2.1.2
dcPwrSysRelayIntegerValueThe integer value of the relay variable as reported by the DC power system controller relay output group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.4.1.2.1.3
dcPwrSysRelayStringValueThe string value of the relay variable as reported by the DC power system controller relay output group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.4.1.2.1.4
dcPwrSysRelaySeverityThe integer value of relay severity level of the extra variable as reported by the DC power system controller relay output group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.4.1.2.1.5
dcPwrSysAnalogOpTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.4.2
dcPwrSysAnalogOpCountNumber of analog output variables in system controller analog output table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.4.2.1
dcPwrSysAnalogOpTableA table of DC power system controller analog output variables.
SEQUENCE OF DcPwrSysAnalogOpEntry
.1.3.6.1.4.1.7309.4.1.4.2.2
dcPwrSysAnalogOpEntryAn entry into the DC power system controller analog output group.
DcPwrSysAnalogOpEntry
.1.3.6.1.4.1.7309.4.1.4.2.2.1
dcPwrSysAnalogOpIndexThe index of the analog variable in the power system controller analog output group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.4.2.2.1.1
dcPwrSysAnalogOpNameThe description of the analog variable as reported by the DC power system controller analog output group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.4.2.2.1.2
dcPwrSysAnalogOpIntegerValueThe integer value of the analog variable as reported by the DC power system controller analog output group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.4.2.2.1.3
dcPwrSysAnalogOpStringValueThe string value of the analog variable as reported by the DC power system controller analog output group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.4.2.2.1.4
dcPwrSysAnalogOpSeverityThe integer value of analog severity level of the extra variable as reported by the DC power system controller analog output group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.4.2.2.1.5
dcPwrSysAlrmsTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5
dcPwrSysRectAlrmTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5.1
dcPwrSysRectAlrmCountNumber of rectifier alarm variables in system controller alarm table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.1.1
dcPwrSysRectAlrmTableA table of DC power system controller rectifier alarm variables.
SEQUENCE OF DcPwrSysRectAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.1.2
dcPwrSysRectAlrmEntryAn entry into the DC power system controller rectifier alarm group.
DcPwrSysRectAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.1.2.1
dcPwrSysRectAlrmIndexThe index of the alarm variable in the DC power system controller table rectifier alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.1.2.1.1
dcPwrSysRectAlrmNameThe description of the alarm variable as reported by the DC power system controller rectifier alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.1.2.1.2
dcPwrSysRectAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller rectifier alarm group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.5.1.2.1.3
dcPwrSysRectAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller rectifier alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.1.2.1.4
dcPwrSysRectAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller rectifier alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.1.2.1.5
dcPwrSysDigAlrmTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5.2
dcPwrSysDigAlrmCountNumber of digital alarm variables in system controller alarm table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.2.1
dcPwrSysDigAlrmTableA table of DC power system controller digital alarm variables.
SEQUENCE OF DcPwrSysDigAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.2.2
dcPwrSysDigAlrmEntryAn entry into the DC power system controller digital alarm group.
DcPwrSysDigAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.2.2.1
dcPwrSysDigAlrmIndexThe index of the alarm variable in the DC power system controller table digital alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.2.2.1.1
dcPwrSysDigAlrmNameThe description of the alarm variable as reported by the DC power system controller digital alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.2.2.1.2
dcPwrSysDigAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller digital alarm group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.5.2.2.1.3
dcPwrSysDigAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller digital alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.2.2.1.4
dcPwrSysDigAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller digital alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.2.2.1.5
dcPwrSysCurrAlrmTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5.3
dcPwrSysCurrAlrmCountNumber of current alarm variables in system controller alarm table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.3.1
dcPwrSysCurrAlrmTableA table of DC power system controller current alarm variables.
SEQUENCE OF DcPwrSysCurrAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.3.2
dcPwrSysCurrAlrmEntryAn entry into the DC power system controller current alarm group.
DcPwrSysCurrAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.3.2.1
dcPwrSysCurrAlrmIndexThe index of the alarm variable in the DC power system controller table current alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.3.2.1.1
dcPwrSysCurrAlrmNameThe description of the alarm variable as reported by the DC power system controller current alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.3.2.1.2
dcPwrSysCurrAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller current alarm group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.5.3.2.1.3
dcPwrSysCurrAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller current alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.3.2.1.4
dcPwrSysCurrAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller current alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.3.2.1.5
dcPwrSysVoltAlrmTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5.4
dcPwrSysVoltAlrmCountNumber of voltage alarm variables in system controller alarm table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.4.1
dcPwrSysVoltAlrmTableA table of DC power system controller voltage alarm variables.
SEQUENCE OF DcPwrSysVoltAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.4.2
dcPwrSysVoltAlrmEntryAn entry into the DC power system controller voltage alarm group.
DcPwrSysVoltAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.4.2.1
dcPwrSysVoltAlrmIndexThe index of the alarm variable in the DC power system controller table voltage alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.4.2.1.1
dcPwrSysVoltAlrmNameThe description of the alarm variable as reported by the DC power system controller voltage alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.4.2.1.2
dcPwrSysVoltAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller voltage alarm group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.5.4.2.1.3
dcPwrSysVoltAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller voltage alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.4.2.1.4
dcPwrSysVoltAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller voltage alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.4.2.1.5
dcPwrSysBattAlrmTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5.5
dcPwrSysBattAlrmCountNumber of battery alarm variables in system controller alarm table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.5.1
dcPwrSysBattAlrmTableA table of DC power system controller battery alarm variables.
SEQUENCE OF DcPwrSysBattAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.5.2
dcPwrSysBattAlrmEntryAn entry into the DC power system controller battery alarm group.
DcPwrSysBattAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.5.2.1
dcPwrSysBattAlrmIndexThe index of the alarm variable in the DC power system controller table battery alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.5.2.1.1
dcPwrSysBattAlrmNameThe description of the alarm variable as reported by the DC power system controller battery alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.5.2.1.2
dcPwrSysBattAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller battery alarm group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.5.5.2.1.3
dcPwrSysBattAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller battery alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.5.2.1.4
dcPwrSysBattAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller battery alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.5.2.1.5
dcPwrSysTempAlrmTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5.6
dcPwrSysTempAlrmCountNumber of temperature alarm variables in system controller alarm table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.6.1
dcPwrSysTempAlrmTableA table of DC power system controller temperature alarm variables.
SEQUENCE OF DcPwrSysTempAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.6.2
dcPwrSysTempAlrmEntryAn entry into the DC power system controller temperature alarm group.
DcPwrSysTempAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.6.2.1
dcPwrSysTempAlrmIndexThe index of the alarm variable in the DC power system controller table temperature alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.6.2.1.1
dcPwrSysTempAlrmNameThe description of the alarm variable as reported by the DC power system controller temperature alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.6.2.1.2
dcPwrSysTempAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller temperature alarm group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.5.6.2.1.3
dcPwrSysTempAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller temperature alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.6.2.1.4
dcPwrSysTempAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller temperature alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.6.2.1.5
dcPwrSysCustomAlrmTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5.7
dcPwrSysCustomAlrmCountNumber of custom alarm variables in system controller alarm table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.7.1
dcPwrSysCustomAlrmTableA table of DC power system controller custom alarm variables.
SEQUENCE OF DcPwrSysCustomAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.7.2
dcPwrSysCustomAlrmEntryAn entry into the DC power system controller custom alarm group.
DcPwrSysCustomAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.7.2.1
dcPwrSysCustomAlrmIndexThe index of the alarm variable in the DC power system controller table custom alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.7.2.1.1
dcPwrSysCustomAlrmNameThe description of the alarm variable as reported by the DC power system controller custom alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.7.2.1.2
dcPwrSysCustomAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller custom alarm group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.5.7.2.1.3
dcPwrSysCustomAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller custom alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.7.2.1.4
dcPwrSysCustomAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller custom alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.7.2.1.5
dcPwrSysMiscAlrmTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5.8
dcPwrSysMiscAlrmCountNumber of misc alarm variables in system controller alarm table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.8.1
dcPwrSysMiscAlrmTableA table of DC power system controller misc alarm variables.
SEQUENCE OF DcPwrSysMiscAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.8.2
dcPwrSysMiscAlrmEntryAn entry into the DC power system controller misc alarm group.
DcPwrSysMiscAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.8.2.1
dcPwrSysMiscAlrmIndexThe index of the alarm variable in the DC power system controller table misc alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.8.2.1.1
dcPwrSysMiscAlrmNameThe description of the alarm variable as reported by the DC power system controller misc alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.8.2.1.2
dcPwrSysMiscAlrmIntegerValueThe integer value of the alarm variable as reported by the DC power system controller misc alarm group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.5.8.2.1.3
dcPwrSysMiscAlrmStringValueThe string value of the alarm variable as reported by the DC power system controller misc alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.8.2.1.4
dcPwrSysMiscAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the DC power system controller misc alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.8.2.1.5
dcPwrSysCtrlAlrmTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5.9
dcPwrSysCtrlAlrmCountThe number of control alarm variables.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.9.1
dcPwrSysCtrlAlrmTableA table of control alarm variables.
SEQUENCE OF DcPwrSysCtrlAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.9.2
dcPwrSysCtrlAlrmEntryAn entry of the control alarm group
DcPwrSysCtrlAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.9.2.1
dcPwrSysCtrlAlrmIndexThe index of the alarm variable in the control alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.9.2.1.1
dcPwrSysCtrlAlrmNameThe description of the alarm variable as reported by the control alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.9.2.1.2
dcPwrSysCtrlAlrmIntegerValueThe integer value of the alarm variable as reported by the control alarm group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.5.9.2.1.3
dcPwrSysCtrlAlrmStringValueThe string value of the alarm variable as reported by the control alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.9.2.1.4
dcPwrSysCtrlAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the control alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.9.2.1.5
dcPwrSysAdioAlrmTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5.10
dcPwrSysAdioAlrmCountNumber of control alarm variables in Adio alarm table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.10.1
dcPwrSysAdioAlrmTableA table of Adio alarm variables.
SEQUENCE OF DcPwrSysAdioAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.10.2
dcPwrSysAdioAlrmEntryAn entry into the Adio alarm group.
DcPwrSysAdioAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.10.2.1
dcPwrSysAdioAlrmIndexThe index of the alarm variable in the table Adio alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.10.2.1.1
dcPwrSysAdioAlrmNameThe description of the alarm variable as reported by the Adio alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.10.2.1.2
dcPwrSysAdioAlrmIntegerValueThe integer value of the alarm variable as reported by the Adio alarm group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.5.10.2.1.3
dcPwrSysAdioAlrmStringValueThe string value of the alarm variable as reported by the Adio alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.10.2.1.4
dcPwrSysAdioAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the control alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.10.2.1.5
dcPwrSysConvAlrmTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5.11
dcPwrSysConvAlrmCountNumber of Converter alarm variables in system controller alarm table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.11.1
dcPwrSysConvAlrmTableA table of Converter alarm variables.
SEQUENCE OF DcPwrSysConvAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.11.2
dcPwrSysConvAlrmEntryAn entry into the Converter alarm group.
DcPwrSysConvAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.11.2.1
dcPwrSysConvAlrmIndexThe index of the alarm variable in the DC power system controller table Converter alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.11.2.1.1
dcPwrSysConvAlrmNameThe description of the alarm variable as reported by the Converter alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.11.2.1.2
dcPwrSysConvAlrmIntegerValueThe integer value of the alarm variable as reported by the Converter alarm group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.5.11.2.1.3
dcPwrSysConvAlrmStringValueThe string value of the alarm variable as reported by the Converter alarm group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.5.11.2.1.4
dcPwrSysConvAlrmSeverityThe integer value of alarm severity level of the extra variable as reported by the Converter alarm group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.11.2.1.5
dcPwrSysInvAlrmTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.5.12
dcPwrSysInvAlrmCountNumber of alarm variables in system controller alarm tablero
INTEGER
.1.3.6.1.4.1.7309.4.1.5.12.1
dcPwrSysInvAlrmTableA table of power system controller Inv alarm variables
SEQUENCE OF DcPwrSysInvAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.12.2
dcPwrSysInvAlrmEntryAn entry into the power system controller Inv alarm group
DcPwrSysInvAlrmEntry
.1.3.6.1.4.1.7309.4.1.5.12.2.1
dcPwrSysInvAlrmIndexro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.12.2.1.1
dcPwrSysInvAlrmNamero
DisplayString
.1.3.6.1.4.1.7309.4.1.5.12.2.1.2
dcPwrSysInvAlrmIntegerValuero
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.5.12.2.1.3
dcPwrSysInvAlrmStringValuero
DisplayString
.1.3.6.1.4.1.7309.4.1.5.12.2.1.4
dcPwrSysInvAlrmSeverityro
INTEGER
.1.3.6.1.4.1.7309.4.1.5.12.2.1.5
dcPwrSysInputsTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.6
dcPwrSysDigIpTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.6.1
dcPwrSysDigIpCountNumber of digital input variables in system controller digital input table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.1.1
dcPwrSysDigIpTableA table of digital input variables.
SEQUENCE OF DcPwrSysDigIpEntry
.1.3.6.1.4.1.7309.4.1.6.1.2
dcPwrSysDigIpEntryAn entry into the digital input group.
DcPwrSysDigIpEntry
.1.3.6.1.4.1.7309.4.1.6.1.2.1
dcPwrSysDigIpIndexThe index of the digital input variable in the table digital input group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.1.2.1.1
dcPwrSysDigIpNameThe description of the digital input variable as reported by the digital input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.1.2.1.2
dcPwrSysDigIpIntegerValueThe integer value of the digital input variable as reported by the digital input group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.6.1.2.1.3
dcPwrSysDigIpStringValueThe string value of the digital input variable as reported by the digital input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.1.2.1.4
dcPwrSysCntrlrIpTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.6.2
dcPwrSysCntrlrIpCountNumber of controller input variables in system controller controller input table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.2.1
dcPwrSysCntrlrIpTableA table of controller input variables.
SEQUENCE OF DcPwrSysCntrlrIpEntry
.1.3.6.1.4.1.7309.4.1.6.2.2
dcPwrSysCntrlrIpEntryAn entry into the controller input group.
DcPwrSysCntrlrIpEntry
.1.3.6.1.4.1.7309.4.1.6.2.2.1
dcPwrSysCntrlrIpIndexThe index of the controller input variable in the table controller input group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.2.2.1.1
dcPwrSysCntrlrIpNameThe description of the controller input variable as reported by the controller input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.2.2.1.2
dcPwrSysCntrlrIpIntegerValueThe integer value of the controller input variable as reported by the controller input group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.6.2.2.1.3
dcPwrSysCntrlrIpStringValueThe string value of the controller input variable as reported by the controller input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.2.2.1.4
dcPwrSysRectIpTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.6.3
dcPwrSysRectIpCountNumber of rectifier input variables in system controller rectifier input table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.3.1
dcPwrSysRectIpTableA table of rectifier input variables.
SEQUENCE OF DcPwrSysRectIpEntry
.1.3.6.1.4.1.7309.4.1.6.3.2
dcPwrSysRectIpEntryAn entry into the rectifier input group.
DcPwrSysRectIpEntry
.1.3.6.1.4.1.7309.4.1.6.3.2.1
dcPwrSysRectIpIndexThe index of the rectifier input variable in the table rectifier input group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.3.2.1.1
dcPwrSysRectIpNameThe description of the rectifier input variable as reported by the rectifier input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.3.2.1.2
dcPwrSysRectIpIntegerValueThe integer value of the rectifier input variable as reported by the rectifier input group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.6.3.2.1.3
dcPwrSysRectIpStringValueThe string value of the rectifier input variable as reported by the rectifier input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.3.2.1.4
dcPwrSysCustomIpTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.6.4
dcPwrSysCustomIpCountNumber of custom input variables in system controller custom input table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.4.1
dcPwrSysCustomIpTableA table of digital custom variables.
SEQUENCE OF DcPwrSysCustomIpEntry
.1.3.6.1.4.1.7309.4.1.6.4.2
dcPwrSysCustomIpEntryAn entry into the custom input group.
DcPwrSysCustomIpEntry
.1.3.6.1.4.1.7309.4.1.6.4.2.1
dcPwrSysCustomIpIndexThe index of the custom input variable in the table custom input group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.4.2.1.1
dcPwrSysCustomIpNameThe description of the custom input variable as reported by the custom input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.4.2.1.2
dcPwrSysgCustomIpIntegerValueThe integer value of the custom input variable as reported by the custom input group.rw
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.6.4.2.1.3
dcPwrSysCustomIpStringValueThe string value of the custom input variable as reported by the custom input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.4.2.1.4
dcPwrSysConvIpTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.6.5
dcPwrSysConvIpCountNumber of Converter input variables in system controller Converter input table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.5.1
dcPwrSysConvIpTableA table of Converter input variables.
SEQUENCE OF DcPwrSysConvIpEntry
.1.3.6.1.4.1.7309.4.1.6.5.2
dcPwrSysConvIpEntryAn entry into the Converter input group.
DcPwrSysConvIpEntry
.1.3.6.1.4.1.7309.4.1.6.5.2.1
dcPwrSysConvIpIndexThe index of the Converter input variable in the table Converter input group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.5.2.1.1
dcPwrSysConvIpNameThe description of the Converter input variable as reported by the Converter input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.5.2.1.2
dcPwrSysConvIpIntegerValueThe integer value of the Converter input variable as reported by the Converter input group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.6.5.2.1.3
dcPwrSysConvIpStringValueThe string value of the Converter input variable as reported by the Converter input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.5.2.1.4
dcPwrSysTimerIpTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.6.6
dcPwrSysTimerIpCountNumber of Timer input variables in system controller Timer input table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.6.1
dcPwrSysTimerIpTableA table of Timer input variables
SEQUENCE OF DcPwrSysTimerIpEntry
.1.3.6.1.4.1.7309.4.1.6.6.2
dcPwrSysTimerIpEntryAn entry into the Timer input group
DcPwrSysTimerIpEntry
.1.3.6.1.4.1.7309.4.1.6.6.2.1
dcPwrSysTimerIpIndexThe index of the Timer input variable in the table Timer input group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.6.2.1.1
dcPwrSysTimerIpNameThe description of the Timer input variable as reported by the Timer input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.6.2.1.2
dcPwrSysTimerIpIntegerValueThe integer value of the Timer input variable as reported by the Timer input group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.6.6.2.1.3
dcPwrSysTimerIpStringValueThe string value of the Timer input variable as reported by the Timer input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.6.2.1.4
dcPwrSysCounterIpTbl
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.6.7
dcPwrSysCounterIpCountNumber of Counter input variables in system controller Counter input table.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.7.1
dcPwrSysCounterIpTableA table of Counter input variables.
SEQUENCE OF DcPwrSysCounterIpEntry
.1.3.6.1.4.1.7309.4.1.6.7.2
dcPwrSysCounterIpEntryAn entry into the Counter input group.
DcPwrSysCounterIpEntry
.1.3.6.1.4.1.7309.4.1.6.7.2.1
dcPwrSysCounterIpIndexThe index of the Counter input variable in the table Counter input group.ro
INTEGER
.1.3.6.1.4.1.7309.4.1.6.7.2.1.1
dcPwrSysCounterIpNameThe description of the Counter input variable as reported by the Counter input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.7.2.1.2
dcPwrSysCounterIpIntegerValueThe integer value of the Counter input variable as reported by the Counter input group.ro
INTEGER (-1000000000..1000000000)
.1.3.6.1.4.1.7309.4.1.6.7.2.1.3
dcPwrSysCounterIpStringValueThe string value of the Counter input variable as reported by the Counter input group.ro
DisplayString
.1.3.6.1.4.1.7309.4.1.6.7.2.1.4
dcPwrExternalControls
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.8
dcPwrSysResyncAlarmsSend/Resend all active alarms that were previously sent through SNMP notification.rw
INTEGER
.1.3.6.1.4.1.7309.4.1.8.1
dcPwrVarbindNameReference
OBJECT IDENTIFIER
.1.3.6.1.4.1.7309.4.1.9
dcPwrSysAlarmTriggerValuero
INTEGER
.1.3.6.1.4.1.7309.4.1.9.1
dcPwrSysTimeStampro
DisplayString
.1.3.6.1.4.1.7309.4.1.9.2
AlphaPowerSystem-MIB - SNMP MIB Reference | MIBs Explorer