Home/Catalog/ROOMALERT24E-MIB

ROOMALERT24E-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for ROOMALERT24E-MIB.

98
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

98 total
Object Name
avtech
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916
RFC1155-SMI
Unknown
.1.3.6.1.4.1.20916
products
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1
roomalert24e
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5
tempalarm1-24eA tempalarm1 trap signifies that the current temperature on external sensor 1 is outside the defined high or low threshold.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.1
room-alert-24e-snmp-trapA room-alert-24e-snmp-trap indicates that an alarm condition has occurred on the sensor indicated by the alarmmessage variable.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.2
tempalarm2-24eA tempalarm2 trap signifies that the current temperature on external sensor 2 is outside the defined high or low threshold.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.3
tempclear2-24eA tempclear2 trap signifies that the current temperature on external sensor 2 has returned to a normal condition and is within the defined high or low threshold.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.4
tempalarm3-24eA tempalarm3 trap signifies that the current temperature on external sensor 3 is outside the defined high or low threshold.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.5
tempclear3-24eA tempclear3 trap signifies that the current temperature on external sensor 3 has returned to a normal condition and is within the defined high or low threshold.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.6
humidityalarm1-24eA humidityalarm1 trap signifies that the current humidity on external sensor 1 is outside the defined high or low threshold.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.7
humidityclear1-24eA humidityclear1 trap signifies that the current humidity on external sensor 1 has returned to a normal condition and is within the defined high or low threshold.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.8
humidityalarm2-24eA humidityalarm2 trap signifies that the current humidity on external sensor 2 is outside the defined high or low threshold.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.9
humidityclear2-24eA humidityclear2 trap signifies that the current humidity on external sensor 2 has returned to a normal condition and is within the defined high or low threshold.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.10
humidityalarm3-24eA humidityalarm3 trap signifies that the current humidity on external sensor 3 is outside the defined high or low threshold.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.11
humidityclear3-24eA humidityclear3 trap signifies that the current humidity on external sensor 3 has returned to a normal condition and is within the defined high or low threshold.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.12
switchalarm1-24eA switchalarm1 trap signifies that switch sensor 1 is in an alarm state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.13
switchclear1-24eA switchclear1 trap signifies that the switch sensor 1 has returned to a normal state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.14
switchalarm2-24eA switchalarm2 trap signifies that switch sensor 2 is in an alarm state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.15
switchclear2-24eA switchclear2 trap signifies that the switch sensor 2 has returned to a normal state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.16
switchalarm3-24eA switchalarm1 trap signifies that switch sensor 1 is in an alarm state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.17
switchclear3-24eA switchclear3 trap signifies that the switch sensor 3 has returned to a normal state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.18
switchalarm4-24eA switchalarm4 trap signifies that switch sensor 4 is in an alarm state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.19
switchclear4-24eA switchclear4 trap signifies that the switch sensor 4 has returned to a normal state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.20
switchalarm5-24eA switchalarm5 trap signifies that switch sensor 5 is in an alarm state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.21
switchclear5-24eA switchclear5 trap signifies that the switch sensor 5 has returned to a normal state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.22
switchalarm6-24eA switchalarm6 trap signifies that switch sensor 6 is in an alarm state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.23
switchclear6-24eA switchclear6 trap signifies that the switch sensor 6 has returned to a normal state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.24
switchalarm7-24eA switchalarm7 trap signifies that switch sensor 7 is in an alarm state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.25
switchclear7-24eA switchclear7 trap signifies that the switch sensor 7 has returned to a normal state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.26
switchalarm8-24eA switchalarm8 trap signifies that switch sensor 8 is in an alarm state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.27
switchclear8-24eA switchclear8 trap signifies that the switch sensor 8 has returned to a normal state.
TRAP-TYPE
.1.3.6.1.4.1.20916.1.5.0.28
sensors
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1
internal
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1.1
temperature
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1.1.1
internal-tempfThe internal temperature reading in Fahrenheit. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divided by 100 to get the actual value.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.1.1.1
internal-tempcThe internal temperature reading in Celsius. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divided by 100 to get the actual value.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.1.1.2
humidity
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1.1.2
internal-humidityThe internal relative humidity reading in %RH. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divided by 100 to get the actual value.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.1.2.1
heat-index
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1.1.3
internal-heat-indexThe internal heat index reading in Fahrenheit. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divided by 100 to get the actual value.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.1.3.1
internal-heat-indexcThe internal heat index reading in Celsius. Because the SNMP Protocol does not support floating point numbers, values are scaled by 100 and should be divided by 100 to get the actual value.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.1.3.2
digital
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1.2
digital-sen1
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1.2.1
digital-sen1-1If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.1.1
digital-sen1-2If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Power reading in Watts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.1.2
digital-sen1-3If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor, this value represents the Voltage reading in Volts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.1.3
digital-sen1-4If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Reference reading in Volts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.1.4
digital-sen1-5If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.1.5
digital-sen2
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1.2.2
digital-sen2-1If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.2.1
digital-sen2-2If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Power reading in Watts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.2.2
digital-sen2-3If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor, this value represents the Voltage reading in Volts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.2.3
digital-sen2-4If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Reference reading in Volts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.2.4
digital-sen2-5If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.2.5
digital-sen3
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1.2.3
digital-sen3-1If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.3.1
digital-sen3-2If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Power reading in Watts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.3.2
digital-sen3-3If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor, this value represents the Voltage reading in Volts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.3.3
digital-sen3-4If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Reference reading in Volts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.3.4
digital-sen3-5If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.3.5
digital-sen4
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1.2.4
digital-sen4-1If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.4.1
digital-sen4-2If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Power reading in Watts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.4.2
digital-sen4-3If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor, this value represents the Voltage reading in Volts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.4.3
digital-sen4-4If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Reference reading in Volts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.4.4
digital-sen4-5If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.4.5
digital-sen5
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1.2.5
digital-sen5-1If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.5.1
digital-sen5-2If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Power reading in Watts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.5.2
digital-sen5-3If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor, this value represents the Voltage reading in Volts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.5.3
digital-sen5-4If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Reference reading in Volts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.5.4
digital-sen5-5If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.5.5
digital-sen6
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1.2.6
digital-sen6-1If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Celsius. If this sensor is a Digital Power Sensor, this value represents the Current reading in Amperage.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.6.1
digital-sen6-2If this sensor is a Temperature or Temp/Humidity sensor, this value represents the current temperature in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Power reading in Watts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.6.2
digital-sen6-3If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Digital Power Sensor, this value represents the Voltage reading in Volts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.6.3
digital-sen6-4If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Digital Power Sensor, this value represents the Reference reading in Volts.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.6.4
digital-sen6-5If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius.ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.2.6.5
switch
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.1.3
switch-sen1The reading for switch sensor 1 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.1
switch-sen2The reading for switch sensor 2 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.2
switch-sen3The reading for switch sensor 3 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.3
switch-sen4The reading for switch sensor 4 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.4
switch-sen5The reading for switch sensor 5 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.5
switch-sen6The reading for switch sensor 6 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.6
switch-sen7The reading for switch sensor 7 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.7
switch-sen8The reading for switch sensor 8 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.8
switch-sen9The reading for switch sensor 9 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.9
switch-sen10The reading for switch sensor 10 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.10
switch-sen11The reading for switch sensor 11 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.11
switch-sen12The reading for switch sensor 12 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.12
switch-sen13The reading for switch sensor 13 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.13
switch-sen14The reading for switch sensor 14 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.14
switch-sen15The reading for switch sensor 15 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.15
switch-sen16The reading for switch sensor 16 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.5.1.3.16
traps
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.5.2
alarmmessageLast Alarm Messagero
OCTET STRING
.1.3.6.1.4.1.20916.1.5.2.1
ROOMALERT24E-MIB - SNMP MIB Reference | MIBs Explorer