ROOMALERT11E-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for ROOMALERT11E-MIB.
106
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
106 total| Object Name |
|---|
avtech OBJECT IDENTIFIER .1.3.6.1.4.1.20916 |
RFC1155-SMI Unknown .1.3.6.1.4.1.20916 |
products OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1 |
roomalert11E OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3 |
tempAlarm1-11eA tempAlarm1 trap signifies that the current
temperature on external sensor 1 is outside the
defined high or low threshold. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.1 |
room-alert-11E-SNMP-trapA Room Alert 11E SNMP Trap indicates that an alarm
condition has occurred on the sensor inidcated
by the alarmMessage variable. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.2 |
tempAlarm2-11eA tempAlarm2 trap signifies that the current
temperature on external sensor 2 is outside the
defined high or low threshold. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.3 |
tempClear2-11eA tempClear2 trap signifies that the current
temperature on external sensor 2 has returned to
a normal condition and is within the defined
high or low threshold. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.4 |
tempAlarm3-11eA tempAlarm3 trap signifies that the current
temperature on external sensor 3 is outside the
defined high or low threshold. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.5 |
tempClear3-11eA tempClear3 trap signifies that the current
temperature on external sensor 3 has returned to
a normal condition and is within the defined
high or low threshold. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.6 |
humidityAlarm1-11eA humidityAlarm1 trap signifies that the current
humidity on external sensor 1 is outside the
defined high or low threshold. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.7 |
humidityClear1-11eA humidityClear1 trap signifies that the current
humidity on external sensor 1 has returned to
a normal condition and is within the defined
high or low threshold. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.8 |
humidityAlarm2-11eA humidityAlarm2 trap signifies that the current
humidity on external sensor 2 is outside the
defined high or low threshold. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.9 |
humidityClear2-11eA humidityClear2 trap signifies that the current
humidity on external sensor 2 has returned to
a normal condition and is within the defined
high or low threshold. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.10 |
humidityAlarm3-11eA humidityAlarm3 trap signifies that the current
humidity on external sensor 3 is outside the
defined high or low threshold. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.11 |
humidityClear3-11eA humidityClear3 trap signifies that the current
humidity on external sensor 3 has returned to
a normal condition and is within the defined
high or low threshold. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.12 |
switchAlarm1-11eA switchAlarm1 trap signifies that switch sensor 1
is in an alarm state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.13 |
switchClear1-11eA switchClear1 trap signifies that the switch sensor 1
has returned to a normal state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.14 |
switchAlarm2-11eA switchAlarm2 trap signifies that switch sensor 2
is in an alarm state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.15 |
switchClear2-11eA switchClear2 trap signifies that the switch sensor 2
has returned to a normal state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.16 |
switchAlarm3-11eA switchAlarm1 trap signifies that switch sensor 1
is in an alarm state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.17 |
switchClear3-11eA switchClear3 trap signifies that the switch sensor 3
has returned to a normal state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.18 |
switchAlarm4-11eA switchAlarm4 trap signifies that switch sensor 4
is in an alarm state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.19 |
switchClear4-11eA switchClear4 trap signifies that the switch sensor 4
has returned to a normal state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.20 |
switchAlarm5-11eA switchAlarm5 trap signifies that switch sensor 5
is in an alarm state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.21 |
switchClear5-11eA switchClear5 trap signifies that the switch sensor 5
has returned to a normal state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.22 |
switchAlarm6-11eA switchAlarm6 trap signifies that switch sensor 6
is in an alarm state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.23 |
switchClear6-11eA switchClear6 trap signifies that the switch sensor 6
has returned to a normal state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.24 |
switchAlarm7-11eA switchAlarm7 trap signifies that switch sensor 7
is in an alarm state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.25 |
switchClear7-11eA switchClear7 trap signifies that the switch sensor 7
has returned to a normal state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.26 |
switchAlarm8-11eA switchAlarm8 trap signifies that switch sensor 8
is in an alarm state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.27 |
switchClear8-11eA switchClear8 trap signifies that the switch sensor 8
has returned to a normal state. TRAP-TYPE .1.3.6.1.4.1.20916.1.3.0.28 |
sensors OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3.1 |
channel1 OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3.1.1 |
sensor1-1The reading for internal switch sensor 1 (0 = OPEN, 1 = CLOSED).ro INTEGER .1.3.6.1.4.1.20916.1.3.1.1.1 |
sensor1-2The reading for internal switch sensor 2 (0 = OPEN, 1 = CLOSED).ro INTEGER .1.3.6.1.4.1.20916.1.3.1.1.2 |
sensor1-3The reading for internal switch sensor 3 (0 = OPEN, 1 = CLOSED).ro INTEGER .1.3.6.1.4.1.20916.1.3.1.1.3 |
sensor1-4The reading for internal switch sensor 4 (0 = OPEN, 1 = CLOSED).ro INTEGER .1.3.6.1.4.1.20916.1.3.1.1.4 |
sensor1-5The reading for internal switch sensor 5 (0 = OPEN, 1 = CLOSED).ro INTEGER .1.3.6.1.4.1.20916.1.3.1.1.5 |
sensor1-6The reading for internal switch sensor 6 (0 = OPEN, 1 = CLOSED).ro INTEGER .1.3.6.1.4.1.20916.1.3.1.1.6 |
sensor1-7The reading for internal switch sensor 7 (0 = OPEN, 1 = CLOSED).ro INTEGER .1.3.6.1.4.1.20916.1.3.1.1.7 |
sensor1-8The reading for internal switch sensor 8 (0 = OPEN, 1 = CLOSED).ro INTEGER .1.3.6.1.4.1.20916.1.3.1.1.8 |
switch-label-1The label for switch sensor 1ro OCTET STRING .1.3.6.1.4.1.20916.1.3.1.1.9 |
switch-label-2The label for switch sensor 2ro OCTET STRING .1.3.6.1.4.1.20916.1.3.1.1.10 |
switch-label-3The label for switch sensor 3ro OCTET STRING .1.3.6.1.4.1.20916.1.3.1.1.11 |
switch-label-4The label for switch sensor 4ro OCTET STRING .1.3.6.1.4.1.20916.1.3.1.1.12 |
switch-label-5The label for switch sensor 5ro OCTET STRING .1.3.6.1.4.1.20916.1.3.1.1.13 |
switch-label-6The label for switch sensor 6ro OCTET STRING .1.3.6.1.4.1.20916.1.3.1.1.14 |
switch-label-7The label for switch sensor 7ro OCTET STRING .1.3.6.1.4.1.20916.1.3.1.1.15 |
switch-label-8The label for switch sensor 8ro OCTET STRING .1.3.6.1.4.1.20916.1.3.1.1.16 |
channel2 OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3.1.2 |
sensor2-1The reading for sensor 2-1. If a temp or temp/humidity sensor is connected, value will be current temperature in Celsius.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.2.1 |
sensor2-2The reading for sensor 2-2. If a temp or temp/humidity sensor is connected, value will be current temperature in Fahrenheit.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.2.2 |
sensor2-3The reading for sensor 2-3. If temp/humidity sensor is connected, value will be current %RH.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.2.3 |
sensor2-4The reading for sensor 2-4. If temp/humidity sensor is connected, value will be current Heat Index in Fahrenheit.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.2.4 |
sensor2-5The reading for sensor 2-5. If temp/humidity sensor is connected, value will be current Heat Index in Celsius.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.2.5 |
sensor2-6-labelThe label of this sensorro OCTET STRING .1.3.6.1.4.1.20916.1.3.1.2.6 |
channel3 OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3.1.3 |
sensor3-1The reading for sensor 3-1. If a temp or temp/humidity sensor is connected, value will be current temperature in Celsius.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.3.1 |
sensor3-2The reading for sensor 3-2. If a temp or temp/humidity sensor is connected, value will be current temperature in Fahrenheit.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.3.2 |
sensor3-3The reading for sensor 3-3. If temp/humidity sensor is connected, value will be current %RH.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.3.3 |
sensor3-4The reading for sensor 3-4. If temp/humidity sensor is connected, value will be current Heat Index in Fahrenheit.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.3.4 |
sensor3-5The reading for sensor 3-5. If temp/humidity sensor is connected, value will be current Heat Index in Celsius.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.3.5 |
sensor3-6-labelThe label of this sensorro OCTET STRING .1.3.6.1.4.1.20916.1.3.1.3.6 |
channel4 OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3.1.4 |
sensor4-1The reading for sensor 4-1. If a temp or temp/humidity sensor is connected, value will be current temperature in Celsius.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.4.1 |
sensor4-2The reading for sensor 4-2. If a temp or temp/humidity sensor is connected, value will be current temperature in Fahrenheit.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.4.2 |
sensor4-3The reading for sensor 4-3. If temp/humidity sensor is connected, value will be current %RH.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.4.3 |
sensor4-4The reading for sensor 4-4. If temp/humidity sensor is connected, value will be current Heat Index in Fahrenheit.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.4.4 |
sensor4-5The reading for sensor 4-5. If temp/humidity sensor is connected, value will be current Heat Index in Celsius.ro INTEGER .1.3.6.1.4.1.20916.1.3.1.4.5 |
sensor4-6-labelThe label of this sensorro OCTET STRING .1.3.6.1.4.1.20916.1.3.1.4.6 |
traps OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3.2 |
alarm1Alarm for sensor channel 1. The binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary.ro INTEGER .1.3.6.1.4.1.20916.1.3.2.1 |
alarm2Alarm for sensor channel 2. If a digital temperature/humidity or digital temperature sensor is connected to this channel, 0 = sensor ok, 1 = high temp alarm, 2 = low temp alarm, 3 = humidity alarm. If a Switch Sensor Expansion box is connected, the binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary.ro INTEGER .1.3.6.1.4.1.20916.1.3.2.2 |
alarm3Alarm for sensor channel 3. If a digital temperature/humidity or digital temperature sensor is connected to this channel, 0 = sensor ok, 1 = high temp alarm, 2 = low temp alarm, 3 = humidity alarm. If a Switch Sensor Expansion box is connected, the binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary.ro INTEGER .1.3.6.1.4.1.20916.1.3.2.3 |
alarm4Alarm for sensor channel 4. If a digital temperature/humidity or digital temperature sensor is connected to this channel, 0 = sensor ok, 1 = high temp alarm, 2 = low temp alarm, 3 = humidity alarm. If a Switch Sensor Expansion box is connected, the binary equivalent of the decimal number displayed will indicate which switch sensors are currently in an alarm state (0 = sensor ok, 1 = sensor in alarm state). For example, if switch sensors 1 and 4 are in alarm state, the value displayed will be 9, which equals 00001001 in binary.ro INTEGER .1.3.6.1.4.1.20916.1.3.2.4 |
alarmMessage1Alarm Message from sensor channel 1 (Internal)ro OCTET STRING .1.3.6.1.4.1.20916.1.3.2.5 |
alarmMessage2Alarm Message from sensor channel 2 (External)ro OCTET STRING .1.3.6.1.4.1.20916.1.3.2.6 |
alarmMessage3Alarm Message from sensor channel 3 (External)ro OCTET STRING .1.3.6.1.4.1.20916.1.3.2.7 |
alarmMessage4Alarm Message from sensor channel 4 (External)ro OCTET STRING .1.3.6.1.4.1.20916.1.3.2.8 |
thresholds OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3.3 |
channels OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3.3.1 |
channels1 OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3.3.1.1 |
threshold1-1Threshold 1 defined for Channel 1ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.1.1 |
threshold1-2Threshold 2 defined for Channel 1ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.1.2 |
threshold1-3Threshold 3 defined for Channel 1ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.1.3 |
threshold1-4Threshold 4 defined for Channel 1ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.1.4 |
threshold1-5Threshold 5 defined for Channel 1ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.1.5 |
threshold1-6Threshold 6 defined for Channel 1ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.1.6 |
threshold1-7Threshold 7 defined for Channel 1ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.1.7 |
threshold1-8Threshold 8 defined for Channel 1ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.1.8 |
channels2 OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3.3.1.2 |
threshold2-1Threshold 1 defined for Channel 2ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.2.1 |
threshold2-2Threshold 2 defined for Channel 2ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.2.2 |
threshold2-3Threshold 3 defined for Channel 2ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.2.3 |
threshold2-4Threshold 4 defined for Channel 2ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.2.4 |
channels3 OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3.3.1.3 |
threshold3-1Threshold 1 defined for Channel 3ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.3.1 |
threshold3-2Threshold 2 defined for Channel 3ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.3.2 |
threshold3-3Threshold 3 defined for Channel 3ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.3.3 |
threshold3-4Threshold 4 defined for Channel 3ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.3.4 |
channels4 OBJECT IDENTIFIER .1.3.6.1.4.1.20916.1.3.3.1.4 |
threshold4-1Threshold 1 defined for Channel 4ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.4.1 |
threshold4-2Threshold 2 defined for Channel 4ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.4.2 |
threshold4-3Threshold 3 defined for Channel 4ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.4.3 |
threshold4-4Threshold 4 defined for Channel 4ro INTEGER .1.3.6.1.4.1.20916.1.3.3.1.4.4 |