Home/Catalog/ROOMALERT12S-MIB

ROOMALERT12S-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for ROOMALERT12S-MIB.

78
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

78 total
Object Name
avtech
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916
RFC1213-MIB
NOTIFICATION-TYPE
.1.3.6.1.4.1.20916
products
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1
roomalert12S
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12
sensors
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1
internal
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.1
temperature
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.1.1
internal-tempfThe internal temperature reading in Fahrenheit.ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.1.1.1
internal-tempcThe internal temperature reading in Celsius.ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.1.1.2
analog
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.1.2
internal-analog1The current status of the Room Alert 12S analog input (0-5VDC).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.1.2.1
internal-analog-computed1The current computed value of the Room Alert 12S analog input.ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.1.2.2
internal-analog-computed-units1The computed analog units for the Room Alert 12S analog input..ro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.1.2.3
relay
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.1.3
internal-relay1The status of the on-board relay outputrw
INTEGER
.1.3.6.1.4.1.20916.1.12.1.1.3.1
digital
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.2
digital-sen1
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.2.1
digital-sen1-1The sensor's current temperature in Celsius.ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.1.1
digital-sen1-2The sensor's current temperature in Fahrenheit.ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.1.2
digital-sen1-3Varies by sensor type: current % relative humidity, voltage reading (V), power state (1=Power Detected, 0=No Power Detected), thermocouple temperature (C), air speed (m/s), or PM2.5 (mcg/m3).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.1.3
digital-sen1-4Varies by sensor type: current heat index (F), custom analog reading, thermocouple temperature (F), air speed (f/m), or PM10 (mcg/m3).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.1.4
digital-sen1-5Varies by sensor type: current heat index (C), thermocouple fault code (0=No Fault), air flow (CMH), or particulate fault code (0=No Fault).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.1.5
digital-sen1-6Varies by sensor type: current dew point (C) or air flow (CFM).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.1.6
digital-sen1-7Varies by sensor type: current dew point (F).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.1.7
digital-sen1-8The computed analog units for the Room Alert 32S analog input..ro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.2.1.8
digital-sen2
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.2.2
digital-sen2-1The sensor's current temperature in Celsius.ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.2.1
digital-sen2-2The sensor's current temperature in Fahrenheit.ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.2.2
digital-sen2-3Varies by sensor type: current % relative humidity, voltage reading (V), power state (1=Power Detected, 0=No Power Detected), thermocouple temperature (C), air speed (m/s), or PM2.5 (mcg/m3).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.2.3
digital-sen2-4Varies by sensor type: current heat index (F), custom analog reading, thermocouple temperature (F), air speed (f/m), or PM10 (mcg/m3).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.2.4
digital-sen2-5Varies by sensor type: current heat index (C), thermocouple fault code (0=No Fault), air flow (CMH), or particulate fault code (0=No Fault).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.2.5
digital-sen2-6Varies by sensor type: current dew point (C) or air flow (CFM).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.2.6
digital-sen2-7Varies by sensor type: current dew point (F).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.2.7
digital-sen2-8The computed analog units for the Room Alert 32S analog input..ro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.2.2.8
digital-sen3
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.2.3
digital-sen3-1The sensor's current temperature in Celsius.ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.3.1
digital-sen3-2The sensor's current temperature in Fahrenheit.ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.3.2
digital-sen3-3Varies by sensor type: current % relative humidity, voltage reading (V), power state (1=Power Detected, 0=No Power Detected), thermocouple temperature (C), air speed (m/s), or PM2.5 (mcg/m3).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.3.3
digital-sen3-4Varies by sensor type: current heat index (F), custom analog reading, thermocouple temperature (F), air speed (f/m), or PM10 (mcg/m3).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.3.4
digital-sen3-5Varies by sensor type: current heat index (C), thermocouple fault code (0=No Fault), air flow (CMH), or particulate fault code (0=No Fault).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.3.5
digital-sen3-6Varies by sensor type: current dew point (C) or air flow (CFM).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.3.6
digital-sen3-7Varies by sensor type: current dew point (F).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.2.3.7
digital-sen3-8The computed analog units for the Room Alert 32S analog input..ro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.2.3.8
switch
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.3
switch-sen1The reading for switch sensor 1 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.3.1
switch-sen2The reading for switch sensor 2 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.3.2
switch-sen3The reading for switch sensor 3 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.3.3
switch-sen4The reading for switch sensor 4 (0 = OPEN, 1 = CLOSED).ro
INTEGER
.1.3.6.1.4.1.20916.1.12.1.3.4
labels
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.4
int-labels
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.4.1
labels-internal-sen1Internal Sensor Labelro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.4.1.1
digital-labels
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.4.2
labels-digital-sen1Digital Sensor Port 1 Labelro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.4.2.1
labels-digital-sen2Digital Sensor Port 2 Labelro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.4.2.2
labels-digital-sen3Digital Sensor Port 3 Labelro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.4.2.3
switch-labels
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.4.3
labels-switch-sen1Switch 1 Labelro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.4.3.1
labels-switch-sen2Switch 2 Labelro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.4.3.2
labels-switch-sen3Switch 3 Labelro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.4.3.3
labels-switch-sen4Switch 4 Labelro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.4.3.4
analog-labels
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.4.4
labels-analog-sen1Analog Sensor 1 Labelro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.4.4.1
internal-relay-labels
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.4.5
internal-relay-labels1Internal Relay 1 Labelro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.4.5.1
external-relay-labels
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.1.4.6
external-relay-labels1External Relay 1 Labelro
OCTET STRING
.1.3.6.1.4.1.20916.1.12.1.4.6.1
traps
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.2
alarmmessageIndicates that an alarm condition has occurred on the sensor indicated by the alarmMessage variable.
NOTIFICATION-TYPE
.1.3.6.1.4.1.20916.1.12.2.1
externalrelays
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.3
externalrelay1
OBJECT IDENTIFIER
.1.3.6.1.4.1.20916.1.12.3.1
externalrelay1-element-oneThe status of the first element on external relay 1.rw
INTEGER
.1.3.6.1.4.1.20916.1.12.3.1.1
externalrelay1-element-twoThe status of the second element on external relay 1.rw
INTEGER
.1.3.6.1.4.1.20916.1.12.3.1.2
externalrelay1-element-threeThe status of the third element on external relay 1.rw
INTEGER
.1.3.6.1.4.1.20916.1.12.3.1.3
externalrelay1-element-fourThe status of the fourth element on external relay 1.rw
INTEGER
.1.3.6.1.4.1.20916.1.12.3.1.4
externalrelay1-element-fiveThe status of the fifth element on external relay 1.rw
INTEGER
.1.3.6.1.4.1.20916.1.12.3.1.5
externalrelay1-element-sixThe status of the sixth element on external relay 1.rw
INTEGER
.1.3.6.1.4.1.20916.1.12.3.1.6
externalrelay1-element-sevenThe status of the seventh element on external relay 1.rw
INTEGER
.1.3.6.1.4.1.20916.1.12.3.1.7
externalrelay1-element-eightThe status of the eighth element on external relay 1rw
INTEGER
.1.3.6.1.4.1.20916.1.12.3.1.8
ROOMALERT12S-MIB - SNMP MIB Reference | MIBs Explorer