RC-POM-MIB
Imported Objects
Objects
66 total| Object Name |
|---|
rcPlugOptModTableMibOE MIB for Digital Diagnostic Monitoring of pluggable optical modules MODULE-IDENTITY .1.3.6.1.4.1.2272.1.71.0 |
rcPlugOptModTableGibc SFF diagnostic info table SEQUENCE OF RcPlugOptModEntry .1.3.6.1.4.1.2272.1.71.1 |
rcPlugOptModEntryEntry containing info. for a particular port RcPlugOptModEntry .1.3.6.1.4.1.2272.1.71.1.1 |
rcPlugOptModPortIndexAn index value that uniquely identifies a port on a
blade or line-card. InterfaceIndex (IF-MIB) .1.3.6.1.4.1.2272.1.71.1.1.1 |
rcPlugOptModDdmStatusMaskEach bit other than ddm-ok represents a specific error.
Any combination of error bits is allowed.ro Bits .1.3.6.1.4.1.2272.1.71.1.1.2 |
rcPlugOptModCalibrationThe identifier value indicates type of calibration.ro Enumeration .1.3.6.1.4.1.2272.1.71.1.1.3 |
rcPlugOptModPowerMeasureThe identifier value indicates type of external power.ro Enumeration .1.3.6.1.4.1.2272.1.71.1.1.4 |
rcPlugOptModConnectorTypeThe connector type is a 16 character field that
contains ASCII characters, left-aligned and padded
on the right with ASCII spaces. This is an assigned
name that indicates some characteristic of the
layer-1 interface.ro DisplayString .1.3.6.1.4.1.2272.1.71.1.1.5 |
rcPlugOptModVendorNameThe vendor name is a 16 character field that
contains ASCII characters, left-aligned and padded
on the right with ASCII spaces. The vendor name
shall be the full name of the corporation, a
commonly accepted abbreviation of the name, the
SCSI company code, or the stock exchange code for
the corporation.ro DisplayString .1.3.6.1.4.1.2272.1.71.1.1.6 |
rcPlugOptModVendorPartNumberThe vendor part number is a 16 byte field that
contains ASCII characters, left-aligned and padded
on the right with ASCII spaces, defining the vendor
part number or product name.ro DisplayString .1.3.6.1.4.1.2272.1.71.1.1.7 |
rcPlugOptModVendorRevNumberThe vendor revision number is a 4-byte field that
contains ASCII characters, left-aligned and padded
on the right with ASCII spaces, defining the
vendor product revision number.ro DisplayString .1.3.6.1.4.1.2272.1.71.1.1.8 |
rcPlugOptModVendorSNThe vendor serial number is a 16 character field
that contains ASCII characters, left-aligned and
padded on the right with ASCII spaces, defining
the vendor serial number for the transceiver.ro DisplayString .1.3.6.1.4.1.2272.1.71.1.1.9 |
rcPlugOptModVendorDateCodeThe date code is an 8-byte field that contains the
vendor's date code in ASCII. This field is
mandatory and takes the form: YYMMDDLC where
YY is the 2 low order digits of the year (00=2000),
MM is the month, 01 thru 12,
DD is the day, 01 thru 31, and
LC is an optional vendor specific lot code.ro DisplayString .1.3.6.1.4.1.2272.1.71.1.1.10 |
rcPlugOptModPECThis is a 16 byte left-justified ASCII field that
records the Nortel Product Equipment Code order
number for the module. Nortel part numbers are 9
bytes long, so the 10th through 16th byte should
be NULL.ro DisplayString .1.3.6.1.4.1.2272.1.71.1.1.11 |
rcPlugOptModCLEIThis is a 10 byte left-justified ASCII field that
records the Nortel supplied Common Language
Equipment Identifier code for the device. The CLEI
code is a Telcordia human-readable representation
of the 1D barcode.ro DisplayString .1.3.6.1.4.1.2272.1.71.1.1.12 |
rcPlugOptModSupportsDDMThis boolean indicates whether or not the device
supports the DDM capability.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2272.1.71.1.1.13 |
rcPlugOptModAux1MonitoringThis value tells what Aux1 is measuring.The values are
as follows:
0 Auxiliary monitoring not implemented
1 APD Bias Voltage mV (units of 10 mV)
2 Reserved
3 TEC Current (mA)
4 Laser Temperature
5 Laser Wavelength
6 +5V Supply Voltage
7 +3.3V Supply Voltage
8 +1.8V Supply Voltage
9 -5.2V Supply Voltage
10 +5.0V Supply Current (unit of 100 uA)
13 +3.3V Supply Current (unit of 100 uA)
14 +1.8V Supply Current (unit of 100 uA)
15 -5.2V Supply Current (unit of 100 uA)ro INTEGER .1.3.6.1.4.1.2272.1.71.1.1.14 |
rcPlugOptModAux2MonitoringThis value tells you what AUX2 is measuring.The values are
as follows:
0 Auxiliary monitoring not implemented
1 APD Bias Voltage mV (units of 10 mV)
2 Reserved
3 TEC Current (mA)
4 Laser Temperature
5 Laser Wavelength
6 +5V Supply Voltage
7 +3.3V Supply Voltage
8 +1.8V Supply Voltage
9 -5.2V Supply Voltage
10 +5.0V Supply Current (unit of 100 uA)
13 +3.3V Supply Current (unit of 100 uA)
14 +1.8V Supply Current (unit of 100 uA)
15 -5.2V Supply Current (unit of 100 uA)ro INTEGER .1.3.6.1.4.1.2272.1.71.1.1.15 |
rcPlugOptModWaveLengthNominal transmitter output wavelength at room
temperature. It is expressed in nano-meters.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.16 |
rcPlugOptModTemperatureThis value represents the internally measured
module temperature. It is expressed in units of
1/256 of a degree Celsius and can range from -40C
to +125C with 0.0001 accuracy.The most significant byte is
the signed integer part of the number and the
least significant byte is the fraction.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.17 |
rcPlugOptModTemperatureHighAlarmThresholdThis value represents the vendor specified high
temperature threshold. If the device
temperature exceeds this value, a temperature high
is asserted. It is expressed in the same
units as the measured temperature.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.18 |
rcPlugOptModTemperatureLowAlarmThresholdThis value represents the vendor specified low
temperature threshold. If the device
temperature falls below this value, a temperature
low is asserted. It is expressed in the same
units as the measured temperature.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.19 |
rcPlugOptModTemperatureHighWarningThresholdThis value represents the vendor specified high
temperature warning threshold. If the device
temperature exceeds this value, a temperature high
warning is asserted. It is expressed in the same
units as the measured temperature.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.20 |
rcPlugOptModTemperatureLowWarningThresholdThis value represents the vendor specified low
temperature warning threshold. If the device
temperature falls below this value, a temperature
low warning is asserted. It is expressed in the
same units as the measured temperature.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.21 |
rcPlugOptModVoltageThis value represents the internally measured
supply voltage. It is a positive number expressed
in microvolts and can range from 0 to 65535 mV.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.22 |
rcPlugOptModVoltageHighAlarmThresholdThis value represents the vendor specified high
voltage threshold. If the measured voltage exceeds
this value, a high voltage is asserted. It
is a positive number expressed in microvolts.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.23 |
rcPlugOptModVoltageLowAlarmThresholdThis value represents the vendor specified low
voltage threshold. If the measured voltage falls
below this value, a low voltage is asserted.
It is a positive number expressed in microvolts.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.24 |
rcPlugOptModVoltageHighWarningThresholdThis value represents the vendor specified high
voltage warning threshold. If the measured voltage
exceeds this value, a high voltage warning is
asserted. It is a positive number expressed in
microvolts.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.25 |
rcPlugOptModVoltageLowWarningThresholdThis value represents the vendor specified low
voltage warning threshold. If the measured voltage
falls below this value, a low voltage warning is
asserted. It is a positive number expressed in
microvolts.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.26 |
rcPlugOptModBiasThis value represents the internally measured
transmitter laser bias current. It is a positive
number expressed in units of 2 microamps and can
range from 0 to 131 mA with 0.0001 accuracy.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.27 |
rcPlugOptModBiasHighAlarmThresholdThis value represents the vendor specified high
current threshold. If the measured bias
current exceeds this value, a high current alarm
is asserted. It is a positive number expressed
in units of 2 microamps and can range from 0 to
131 mA with 0.0001 accuracy.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.28 |
rcPlugOptModBiasLowAlarmThresholdThis value represents the vendor specified low
current threshold. If the measured bias
current falls below this value, a low current
is asserted. It is a positive number
expressed in units of 2 microamps and can range
from 0 to 131 mA with 0.0001 accuracy.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.29 |
rcPlugOptModBiasHighWarningThresholdThis value represents the vendor specified high
current warning threshold. If the measured bias
current exceeds this value, a high current warning
is asserted. It is a positive number expressed in
units of 2 microamps and can range from 0 to
131 mA with 0.0001 accuracy.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.30 |
rcPlugOptModBiasLowWarningThresholdThis value represents the vendor specified low
current warning threshold. If the measured bias
current falls below this value, a low current
warning is asserted. It is a positive number
expressed in units of 2 microamps and can range
from 0 to 131 mA with 0.0001 accuracy.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.31 |
rcPlugOptModTxPowerThis value represents the internally measured
coupled TX output power. It is a positive number
expressed in units of micro watts and can range
from 0 to 65.535 mW (-40 to 18.16 dBm).ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.32 |
rcPlugOptModTxPowerHighAlarmThresholdThis value represents the vendor specified high
transmit power threshold. If the measured
transmitter power exceeds this value, a
transmitter power high is asserted. It is
a positive number expressed in units of micro
watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.33 |
rcPlugOptModTxPowerLowAlarmThresholdThis value represents the vendor specified low
transmit power threshold. If the measured
transmitter power falls below this value, a
transmitter power low is asserted. It is a
positive number expressed in units of micro watts
and can range from 0 to 65.535 mW (-40 to 18.16 dBm).ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.34 |
rcPlugOptModTxPowerHighWarningThresholdThis value represents the vendor specified high
transmit power warning threshold. If the measured
transmitter power exceeds this value, a
transmitter power high warning is asserted. It is
a positive number expressed in units of units of
micro watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.35 |
rcPlugOptModTxPowerLowWarningThresholdThis value represents the vendor specified low
transmit power warning threshold. If the measured
transmitter power falls below this value, a
transmitter power low warning is asserted. It is
a positive number expressed in units of micro
watts and can range from 0 to 65.535 mW (-40 to 18.16 dBm).ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.36 |
rcPlugOptModRxPowerThis value represents the internally measured
received power. It is a positive number expressed
in units of micro watts and can range from 0 to
65.535 mW (-40 to 18.16 dBm).ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.37 |
rcPlugOptModRxPowerHighAlarmThresholdThis value represents the vendor specified high
receiver power threshold. If the measured
received power exceeds this value, a receiver
power high is asserted. It is a positive
number expressed in units of micro watts and can
range from 0 to 65.535 mW (-40 to 18.16 dBm).ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.38 |
rcPlugOptModRxPowerLowAlarmThresholdThis value represents the vendor specified low
receiver power threshold. If the measured
received power falls below this value, a receiver
power low is asserted. It is a positive
number expressed in units of micro watts and can
range from 0 to 65.535 mW (-40 to 18.16 dBm).ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.39 |
rcPlugOptModRxPowerHighWarningThresholdThis value represents the vendor specified high
receiver power warning threshold. If the measured
received power exceeds this value, a receiver
power high warning is asserted. It is a positive
number expressed in units of units of micro watts
and can range from 0 to 65.535 uW (-40 to 18.16 dBm).ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.40 |
rcPlugOptModRxPowerLowWarningThresholdThis value represents the vendor specified low
receiver power warning threshold. If the measured
received power falls below this value, a receiver
power low warning is asserted. It is a positive
number expressed in units of units of micro watts
and can range from 0 to 65.535 mW (-40 to 18.16 dBm).ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.41 |
rcPlugOptModAux1This represents the internally measured A/D
value specified.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.42 |
rcPlugOptModAux1HighAlarmThresholdThis value represents the vendor specified high
Aux1 threshold.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.43 |
rcPlugOptModAux1LowAlarmThresholdThis value represents the vendor specified low
Aux1 threshold.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.44 |
rcPlugOptModAux1HighWarningThresholdThis value represents the vendor specified high
Aux1 warning threshold.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.45 |
rcPlugOptModAux1LowWarningThresholdThis value represents the vendor specified low
Aux1 warning threshold.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.46 |
rcPlugOptModAux2This represents the internally measured A/D
value specified.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.47 |
rcPlugOptModAux2HighAlarmThresholdThis value represents the vendor specified high
Aux1 threshold.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.48 |
rcPlugOptModAux2LowAlarmThresholdThis value represents the vendor specified low
Aux1 threshold.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.49 |
rcPlugOptModAux2HighWarningThresholdThis value represents the vendor specified high
Aux1 warning threshold.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.50 |
rcPlugOptModAux2LowWarningThresholdThis value represents the vendor specified low
Aux1 warning threshold.ro Integer32 .1.3.6.1.4.1.2272.1.71.1.1.51 |
rcPlugOptModTemperatureStatusUsed to indicate the current temperature statusro Enumeration .1.3.6.1.4.1.2272.1.71.1.1.52 |
rcPlugOptModVoltageStatusUsed to indicate the current voltage statusro Enumeration .1.3.6.1.4.1.2272.1.71.1.1.53 |
rcPlugOptModBiasStatusUsed to indicate the current laser bias statusro Enumeration .1.3.6.1.4.1.2272.1.71.1.1.54 |
rcPlugOptModTxPowerStatusUsed to indicate the current transmitter power
statusro Enumeration .1.3.6.1.4.1.2272.1.71.1.1.55 |
rcPlugOptModRxPowerStatusUsed to indicate the current receiver power statusro Enumeration .1.3.6.1.4.1.2272.1.71.1.1.56 |
rcPlugOptModAux1StatusUsed to indicate the current Aux1 statusro Enumeration .1.3.6.1.4.1.2272.1.71.1.1.57 |
rcPlugOptModAux2StatusUsed to indicate the current Aux2 statusro Enumeration .1.3.6.1.4.1.2272.1.71.1.1.58 |
rcPlugOptModScalars OBJECT IDENTIFIER .1.3.6.1.4.1.2272.1.71.2 |
rcPlugOptModDdmMonitorEnable/disable the global polling monitor for DDMrw EnableValue (RAPID-CITY) .1.3.6.1.4.1.2272.1.71.2.1 |
rcPlugOptModDdmMonitorIntervalIndicate the interval in which the DDM alert registers is polledrw Integer32 .1.3.6.1.4.1.2272.1.71.2.2 |
rcPlugOptModDdmTrapSendEnable/disable the global ddm trap send to SNMP managerrw EnableValue (RAPID-CITY) .1.3.6.1.4.1.2272.1.71.2.3 |
rcPlugOptModDdmAlarmPortdownEnable/disable the global portdown option when ddm alarm occursrw EnableValue (RAPID-CITY) .1.3.6.1.4.1.2272.1.71.2.4 |
More MIBs from Rapidcity
Browse all RapidcityMIBs →The RAPID-CITY MIB module facilitates SNMP-based monitoring and management of Accelar product family hardware, specifically tracking performance metrics such as throughput, connection states, and resource utilization for traffic acceleration appliances.
The RAPID-CITY-VSP MIB provides enterprise-level monitoring and management capabilities for the Accelar product family, enabling the collection of performance metrics, interface statistics, and system health data for Accelar network appliances. This module facilitates the tracking of device availability, traffic throughput, and operational states specific to Accelar's hardware and software implementations.
The RC-CFM-MIB module enables monitoring of Ethernet Connectivity Fault Management (CFM) state variables, including Maintenance Domain, Maintenance Association, and Maintenance Endpoint operational statuses, to detect and isolate Layer 2 network faults. It provides specific counters and gauges for CFM message transmission, reception, and error conditions to facilitate rapid diagnosis of link integrity and service continuity issues.
SNMP MIB module
The RC-IP-POLICY-MIB module provides SNMP access to configure and monitor IP traffic filtering rules, policy routing decisions, and associated session statistics on Accelar network appliances. It enables administrators to track policy hit counts, match conditions, and enforcement states for granular control over packet forwarding and security policies.
SNMP MIB module