PANDATEL-GMDF-MODEM-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for PANDATEL-GMDF-MODEM-MIB.
25
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
25 total| Object Name |
|---|
gmdf OBJECT IDENTIFIER .1.3.6.1.4.1.760.1.1.2.1.10.206 |
gmdfModemTableThis table contains information about all GM-DF converters in all racks. SEQUENCE OF GmdfTableEntry .1.3.6.1.4.1.760.1.1.2.1.10.206.1 |
gmdfTableEntryThe index of the table. GmdfTableEntry .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1 |
mdmRackThe index of the rack where the converter is installed.ro INTEGER .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.1 |
mdmModemThis entry displays the slot number where the corresponding
converter is installed in the rack.ro INTEGER .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.2 |
mdmPositionThis entry displays the location of the corresponding
converter: 'local' or 'remote'. The converter which is plugged
into a managed rack is 'local', the counterpart is 'remote'.ro Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.3 |
mdmModemNameThe verbal name of this converter.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.5 |
mdmInterfaceEmulationModeInterface mode of the unit: 'dte', 'dce', 'te' or 'nt'.ro Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.6 |
mdmModemPropertyThis entry displays the speed class of the GM-DF: 'e1' or 't1'.ro Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.7 |
mdmHDSLUnitHDSL unit type: Line Termination Unit (LTU) or
Network Termination Unit (LTU)rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.10 |
mdmClockSystemThe clock system of the link: 'dual' or 'single'.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.23 |
mdmClockSourceThe clock source of the link: 'internal', 'external', or
'remote'.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.24 |
mdmDataRateThe data rate at the interface in bits per seconds. The data
rate at the remote counterpart changes simultaneously. A data
rate of 2.048 Mbps (E1) automatically disables CRC4, sets
mdmStartTimeslot to 'unframed', enables time slot 16, and disables
remote access. A data rate of 1.984 Mbps (E1) automatically sets
mdmStartTimeslot to 'timeslot-1', enables time slot 16 and sets
mdmRemoteAccessMode to 'via timeslot 0 sa4-bit'. A data rate of
1.544 Mbps (T1) automatically sets mdmStartTimeslot to 'unframed'
and disables remote access.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.25 |
mdmStartTimeslotThis entry determines the start time slot for framing. Start
time slot and data rate must match. A start time slot which
is too high will be ignored. The remote unit's configuration
changes simultaneously.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.26 |
mdmTimeslotSizeThis entry determines the size of the time slots: 'nx64k' or
'nx56k'. 'nx56k' is valid for T1 units only. The remote unit's configuration
changes simultaneously.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.27 |
mdmTimeslot16This entry enables or disables time slot 16. If it is disabled,
it will not be used for data transmission but for framing. Valid
for E1 units only.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.40 |
mdmCRC4GenerationThis entry enables or disables the generation of a CRC4 check
sum. Valid for E1 units only.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.41 |
mdmFramingModeThe T1 framing mode: 'd4' or 'esf'. The remote unit's
configuration changes simultaneously.
Valid for T1 units only.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.50 |
mdmScramblerThis entry enables or disables scrambling.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.63 |
mdmRemoteAccessModeThe remote access mode: 'disable', 'via-next-free-timeslot',
'via-timeslot-0-Sa4-bit', or 'via-hdsl-channel'. The value
'via-next-free-timeslot' means that one time slot higher than the last
data time slot is used for remote access. The value 'via-timeslot-0-Sa4-bit'
means that the sa4-bit in time slot 0 is used for remote access
The remote unit's configuration changes simultaneously.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.64 |
mdmCRC6TestThis entry enables the execution of a CRC6 test. Write requests
with values other than 'start' or 'stop' will be rejected. Valid
for T1 units only.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.100 |
mdmCRC6StatusThis entry indicates the status of the CRC6 test.
Valid for T1 units only.ro Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.101 |
mdmCRC6ErrorThis entry indicates the number of errors detected during
the last 60 seconds.ro Gauge .1.3.6.1.4.1.760.1.1.2.1.10.206.1.1.102 |
gmdf-modem OBJECT IDENTIFIER .1.3.6.1.4.1.760.1.1.2.1.10.10000.2.206 |
RFC1213-MIB Unknown .1.3.6.1.4.1.760.1.1.2.1.10.10000.2.206 |