PANDATEL-FX-MODEM-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for PANDATEL-FX-MODEM-MIB.
14
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
14 total| Object Name |
|---|
fx OBJECT IDENTIFIER .1.3.6.1.4.1.760.1.1.2.1.10.502 |
fxModemTableThe table of all FX modems in this housing. SEQUENCE OF FxTableEntry .1.3.6.1.4.1.760.1.1.2.1.10.502.1 |
fxTableEntryThe index of the table. FxTableEntry .1.3.6.1.4.1.760.1.1.2.1.10.502.1.1 |
mdmRackThe index of the rack where the modem is installed.ro INTEGER .1.3.6.1.4.1.760.1.1.2.1.10.502.1.1.1 |
mdmModemThis variable displays the slot number where the
corresponding modem is installed in the rack.ro INTEGER .1.3.6.1.4.1.760.1.1.2.1.10.502.1.1.2 |
mdmPositionThis variable displays the location of the corresponding
modem: 'local' or 'remote'.
The modem which is plugged into a managed rack is 'local',
the counterpart is 'remote'.ro Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.502.1.1.3 |
mdmModemNameA verbal name of this modem.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.760.1.1.2.1.10.502.1.1.5 |
mdmRemoteAccessModeThe possibility of remote management: 'enabled' or 'disabled'.
Once disabled remote management, it is not possible to enable
it at the remote unit.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.502.1.1.64 |
mdmForcedRemoteAccessActivation of remote management: 'on' or 'off'.
Status 'on' enables management of remote unit. During this
process the link is restricted to management data. The
transmission of user data is interrupted.
Status 'off' disables management of remote unit. The link
transmits user data.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.502.1.1.65 |
mdmClockRecoveryThe clock recovery and data retiming at interface and line port.
The remote unit's configuration changes simultaneously.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.502.1.1.70 |
mdmInterfaceAlarmConditionThe alarm trigger mode at interface port: 'disable', i.e. no alarm
is triggered, 'no-link-signal', i.e. an alarm is triggered if
the link is down, 'laser-fail', i.e. an alarm is triggered
if the laser diode is defective, or 'no-link-signal-or-laser-fail',
i.e. the link is down or the laser diode is defective.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.502.1.1.98 |
mdmLineAlarmConditionThe alarm trigger mode at line port: 'disable', i.e. no alarm
is triggered, 'link-signal', i.e. an alarm is triggered if
the link is down, 'laser-fail', i.e. an alarm is triggered
if the laser diode is defective, or 'link-signal-or-laser-fail',
i.e. the link is down or the laser diode is defective.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.502.1.1.99 |
fx-modem OBJECT IDENTIFIER .1.3.6.1.4.1.760.1.1.2.1.10.10000.2.502 |
RFC1213-MIB Unknown .1.3.6.1.4.1.760.1.1.2.1.10.10000.2.502 |