PANDATEL-FOBUS-MODEM-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for PANDATEL-FOBUS-MODEM-MIB.
17
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
17 total| Object Name |
|---|
fobus OBJECT IDENTIFIER .1.3.6.1.4.1.760.1.1.2.1.10.501 |
fobusModemTableThis table contains information about all FOBUS units in all racks. SEQUENCE OF FobusTableEntry .1.3.6.1.4.1.760.1.1.2.1.10.501.1 |
fobusTableEntryThe index of the table. FobusTableEntry .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1 |
mdmRackThe index of the rack where the unit is installed.ro INTEGER .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.1 |
mdmModemThis entry displays the slot number where the corresponding
unit is installed in the rack.ro INTEGER .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.2 |
mdmPositionThis entry displays the location of the corresponding unit:
'local' or 'remote'. The unit which is plugged into a managed
rack is 'local', the counterpart is 'remote'.ro Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.3 |
mdmModemNameThe verbal name of this unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.5 |
mdmBackupStatusThe backup status of the unit. The available values depend on the
generation of the unit.ro Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.11 |
mdmActiveLinkThis entry displays the line port used for data transmission.ro Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.12 |
mdmOperationModeThis entry defines if data is transmitted via port 2 or port 3:
'forced-port2', 'forced-port3', 'automatic'.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.66 |
mdmAlarmConditionPort1The alarm trigger mode at port 1: 'disable', i.e. no alarm is
triggered, or 'link-signal', i.e. an alarm is triggered if the
link is down.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.110 |
mdmAlarmConditionPort2The alarm trigger mode at port 2: 'disable', i.e. no alarm
is triggered, 'no-link-signal', i.e. an alarm is triggered if
the link is down, 'laser-fail', i.e. an alarm is triggered
if the laser diode is defective, or 'no-link-signal-or-laser-fail',
i.e. the link is down or the laser diode is defective.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.111 |
mdmAlarmConditionPort3The alarm trigger mode at port 3: 'disable', i.e. no alarm
is triggered, 'no-link-signal', i.e. an alarm is triggered if
the link is down, 'laser-fail', i.e. an alarm is triggered
if the laser diode is defective, or 'no-link-signal-or-laser-fail',
i.e. the link is down or the laser diode is defective.rw Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.112 |
mdmTXLaserStatusPort2This entry indicates if the laser diode at port 2 is
transmitting data ('enable') or not ('disable').ro Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.121 |
mdmTXLaserStatusPort3This entry indicates if the laser diode at port 3 is
transmitting data ('enable') or not ('disable').ro Enumeration .1.3.6.1.4.1.760.1.1.2.1.10.501.1.1.122 |
fobus-modem OBJECT IDENTIFIER .1.3.6.1.4.1.760.1.1.2.1.10.10000.2.501 |
RFC1213-MIB Unknown .1.3.6.1.4.1.760.1.1.2.1.10.10000.2.501 |