LIEBERT-UPSTATION-S3-UPS-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for LIEBERT-UPSTATION-S3-UPS-MIB.

131
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

131 total
Object Name
emerson
OBJECT IDENTIFIER
.1.3.6.1.4.1.476
RFC1155-SMI
Unknown
.1.3.6.1.4.1.476
liebertCorp
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1
liebertUps
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1
luExtensions
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1
luCore
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1
lcUpsIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.1
lcUpsIdentManufacturerThe UPS manufacturer.ro
DisplayString
.1.3.6.1.4.1.476.1.1.1.1.1.1
lcUpsIdentModelThe UPS Model designation.rw
DisplayString
.1.3.6.1.4.1.476.1.1.1.1.1.2
lcUpsIdentSoftwareVersionThe UPS SNMP Agent software version.ro
DisplayString
.1.3.6.1.4.1.476.1.1.1.1.1.3
lcUpsIdentSpecificA reference to MIB definitions specific to the particular UPS being managed. This object is used to locate the product-specific MIB for this device. If this information is not present, its value should be the OBJECT IDENTIFIER { 0 0 }, which is a syntactically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.1.4
lcUpsBattery
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.2
lcUpsBatTimeRemainingThe estimated time to depletion of battery charge. (Unit of measure: Minute)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.2.1
lcUpsBatTemperatureThe battery temperature. (Unit of measure: Degree, Centigrade)ro
INTEGER (-32768..32767)
.1.3.6.1.4.1.476.1.1.1.1.2.2
lcUpsBatVoltageThe current battery voltage. (Unit of measure: volt)ro
INTEGER (-32768..32767)
.1.3.6.1.4.1.476.1.1.1.1.2.3
lcUpsBatCurrentThe current battery discharging/charging current. (Unit of measure: Amp)ro
INTEGER (-32768..32767)
.1.3.6.1.4.1.476.1.1.1.1.2.4
lcUpsInput
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.3
lcUpsInputFrequencyThe current input frequency. (Unit of measure: Hertz)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.3.1
lcUpsInputBrownOutsThe number of brown-out conditions the UPS has experienced.ro
Counter
.1.3.6.1.4.1.476.1.1.1.1.3.2
lcUpsInputBlackOutsThe number of black-out conditions the UPS has experienced.ro
Counter
.1.3.6.1.4.1.476.1.1.1.1.3.3
lcUpsInputTransientsThe number of transient (surge and spike) conditions the UPS has experienced.ro
Counter
.1.3.6.1.4.1.476.1.1.1.1.3.4
lcUpsInputNumLinesThe number of input lines utilized in this device. This entry indicates the number of rows in the input table.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.3.5
lcUpsInputTable
SEQUENCE OF LcUpsInputEntry
.1.3.6.1.4.1.476.1.1.1.1.3.6
lcUpsInputEntry
LcUpsInputEntry
.1.3.6.1.4.1.476.1.1.1.1.3.6.1
lcUpsInputLineThe input Line.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.3.6.1.1
lcUpsInputVoltageThe input voltage. (Unit of measure: Volt)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.3.6.1.2
lcUpsInputCurrentThe input current. (Unit of measure: Amp)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.3.6.1.3
lcUpsInputVAThe input volt-amps.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.3.6.1.4
lcUpsOutput
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.4
lcUpsOutputFrequencyThe current output frequency. (Unit of measure: Hertz)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.1
lcUpsOutputLoadThe current output load percentage.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.2
lcUpsOutputNumLinesThe number of output lines utilized in this device. This entry indicates the number of rows in the output table.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.3
lcUpsOutputTable
SEQUENCE OF LcUpsOutputEntry
.1.3.6.1.4.1.476.1.1.1.1.4.4
lcUpsOutputEntry
LcUpsOutputEntry
.1.3.6.1.4.1.476.1.1.1.1.4.4.1
lcUpsOutputLineThe output Line.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.4.1.1
lcUpsOutputVoltageThe output voltage. (Unit of measure: Volt)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.4.1.2
lcUpsOutputCurrentThe output current. (Unit of measure: Amp)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.4.1.3
lcUpsOutputVAThe output volt-amps.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.4.1.4
lcUpsInverter
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.5
lcUpsInverterStatusThe state of the inverter. Unknown is returned if the state can not be determined.ro
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.5.1
lcUpsInverterTempThe temperature of the inverter. (Unit of measure: degree, Centigrade)ro
INTEGER (-32768..32767)
.1.3.6.1.4.1.476.1.1.1.1.5.2
lcUpsAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6
lcUpsAlarmsThe current number of alarm conditions.ro
Gauge
.1.3.6.1.4.1.476.1.1.1.1.6.1
lcUpsAlarmTable
SEQUENCE OF LcUpsAlarmEntry
.1.3.6.1.4.1.476.1.1.1.1.6.2
lcUpsAlarmEntry
LcUpsAlarmEntry
.1.3.6.1.4.1.476.1.1.1.1.6.2.1
lcUpsAlarmIdA unique identifier for an alarm condition. This value must remain constant between agent initializations.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.6.2.1.1
lcUpsAlarmDescrA reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.2.1.2
lcUpsAlarmTimeThe value of sysUpTime when the alarm condition occured.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.476.1.1.1.1.6.2.1.3
lcUpsAlarmConditions
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3
lcUpsAlarmLowBatteryWarning
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.1
lcUpsAlarmLowBatteryShutdown
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.2
lcUpsAlarmUtilFailed
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.3
lcUpsAlarmOverTempWarning
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.4
lcUpsAlarmOutputOverloadWarning
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.6
lcUpsAlarmInputOverVoltage
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.8
lcUpsAlarmBatteryBad
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.9
lcUpsAlarmOnBattery
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.10
lcUpsAlarmUpsOff
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.12
lcUpsTest
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.7
lcUpsTestBatterySetting this variable to 'start' will initiate the battery test. Setting this variable to 'abort' will stop the battery test if the test is in- progress, otherwise it has no effect. Setting this variable to 'unknown' has no effect. Reading this variable will always result in a return value of 'unknown'. If 'lcUpsTestBatteryStatus' is 'failed' the test may not be performed again and the status will remain in the failure state.rw
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.7.1
lcUpsTestBatteryStatusThe status of the battery test.ro
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.7.2
lcUpsTestDiagSetting this variable to 'start' will initiate the diagnostics test. Setting this variable to 'abort' will stop the diagnostics test if the test is in-progress, otherwise it has no effect. Setting this variable to 'unknown' has no effect. Reading this variable will always result in a return value of 'unknown'.rw
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.7.3
lcUpsTestDiagStatusThe status of the diagnostics test.ro
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.7.4
lcUpsControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.8
lcUpsControlOutputOffDelaySetting this object causes the agent to instruct the UPS to turn off the output after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsOutputOffTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value cancel.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.1
lcUpsControlOutputOnDelaySetting this object causes the agent to instruct the UPS to turn on the output after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsOutputOnTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value cancel.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.2
lcUpsControlOutputOffTrapDelayWhen 'lcUpsControlOutputOffDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOffWarningTrap will be produced and this object will be reset to 0.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.3
lcUpsControlOutputOnTrapDelayWhen 'lcUpsControlOutputOnDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOnWarningTrap will be produced and this object will be reset to 0.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.4
lcUpsControlUnixShutdownDelaySetting this object causes the agent to instruct the UPS to perform a UNIX Shutdown in the indicated number of seconds. The agent counts down the number of seconds until the event will take place. A Unix shutdown is only valid if the UPS is on Battery. During a UNIX Shutdown, the UPS will turn off the output even if the Utility comes back on line before the shutdown time arrives. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value 'cancel'.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.5
lcUpsControlUnixShutdownTrapDelayWhen 'lcUpsControlUnixShutdownDelay' reaches a value less than or equal to this object's value, an lcUpsUnixShutdownWarningTrap will be produced and this object will be reset to 0.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.6
lcUpsControlCancelCommandsSetting this variable to 'cancel' will cause the agent to issue instructions to the UPS to cancel all outstanding commands, such as lcUpsControlOutputOff, lcUpsControlOutputOn, lcUpsControlUnixShutdown.rw
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.8.7
lcUpsControlRebootAgentDelaySetting this object causes the agent to reboot after the indicated number of seconds have expired. The value will count down until the event takes place. The command can be cancelled by setting lcUpsControlCancleCommand to the value cancel.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.8
lcUpsNominal
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.9
lcUpsNominalOutputVoltageThe nominal output voltage. (Unit of measure: volt)rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.9.1
lcUpsNominalInputVoltageThe nominal input voltage. (Unit of measure: volt)rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.9.2
lcUpsNominalOutputVAThe nominal Volt-Amp rating.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.9.3
lcUpsNominalOutputWattsThe nominal power rating. (Unit of measure: watt)rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.9.4
lcUpsNominalOutputFreqThe nominal output frequency. (Unit of measure: Hertz)rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.9.5
lcUpsNominalInputFreqThe nominal input frequency. (Unit of measure: Hertz)rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.9.6
lcUpsTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.11
lcUpsOverloadWarningTrapAn lcUpsOverloadWarningTrap signifies that the UPS has detected an Overload condition where the output load has exceeded the UPS's rated capacity.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.1
lcUpsOnBatteryTrapAn lcUpsOnBatteryTrap signifies that the UPS is currently on Battery Power.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.3
lcUpsLowBatteryWarningTrapAn lcUpsLowBatteryWarningTrap signifies that the UPS has entered a Low Battery state.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.4
lcUpsUtilPowerFailedTrapAn lcUpsUtilPowerFailedTrap signifies that the utility power input to the UPS has been lost.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.6
lcUpsUtilPowerRestoredTrapAn lcUpsUtilPowerRestoredTrap signifies that the utility power has been restored to the UPS.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.7
lcUpsInputOverVoltageTrapAn lcUpsInputOverVoltageTrap signifies that the UPS has detected a high input voltage condition.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.8
lcUpsOverTempWarningTrapAn lcUpsOverTempWarningTrap signifies that the UPS has detected a excessive temperature condition.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.9
lcUpsAlarmTrapAn Alarm condition has occurred and is being reported in the lcUpsAlarmTable.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.11
lcUpsOutputOffTrapAn lcUpsOutputOffTrap is sent when the UPS turns all of its output off, either at the inverter or via a relay.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.12
lcUpsOutputOffWarningTrapAn lcUpsOutputOffWarningTrap is sent when the lcUpsControlOutputOffDelay reaches the value of lcUpsControlOutputOffTrapDelay.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.13
lcUpsOutputOnTrapAn lcUpsOutputOnTrap is sent when the UPS turns all of its output back on, either at the inverter or via a relay.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.14
lcUpsOutputOnWarningTrapAn lcUpsOutputOnWarningTrap is sent when the lcUpsControlOutputOnDelay reaches the value of lcUpsControlOutputOnTrapDelay.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.15
lcUpsUnixShutdownTrapAn lcUpsUnixShutodwnTrap is sent 2 seconds before the UPS is scheduled to perform a Unix Shutdown.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.16
lcUpsUnixShutdownWarningTrapAn lcUpsUnixShutdownWarningTrap is sent when the lcUpsControlUnixShudownDelay reaches the value of lcUpsControlUnixShutdownTrapDelay.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.17
lcUpsReceptOffTrapAn lcUpsReceptOffTrap is sent when the UPS turns an output receptacle off.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.18
lcUpsReceptOffWarningTrapAn lcUpsReceptOffWarningTrap is sent when the lcUpsSwitchedReceptOffDelay reaches the value of lcUpsSwitchedReceptOffTrapDelay.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.19
lcUpsReceptOnTrapAn lcUpsReceptOnTrap is sent when the UPS turns an output receptacle on.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.20
lcUpsReceptOnWarningTrapAn lcUpsReceptOnWarningTrap is sent when the lcUpsSwitchedReceptOnDelay reaches the value of lcUpsSwitchedReceptOnTrapDelay.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.21
lcUpsSwitchedReceptacles
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.12
lcUpsSwitchedReceptMaxNumThe maximum number of switched receptacles supported by the Ups.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.12.1
lcUpsSwitchedReceptTable
SEQUENCE OF LcUpsSwitchedReceptEntry
.1.3.6.1.4.1.476.1.1.1.1.12.2
lcUpsSwitchedReceptEntry
LcUpsSwitchedReceptEntry
.1.3.6.1.4.1.476.1.1.1.1.12.2.1
lcUpsSwitchedReceptIndexro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.12.2.1.1
lcUpsSwitchedReceptOnDelaySetting this object causes the agent to instruct the UPS to turn on a receptacle after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsReceptOnTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsSwitchedCancelCommand to the value cancel.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.12.2.1.2
lcUpsSwitchedReceptOnTrapDelayWhen 'lcUpsSwitchedReceptOnDelay' reaches a value less than or equal to this object's value, an lcUpsReceptOnWarningTrap will be produced and this object will be reset to 0.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.12.2.1.3
lcUpsSwitchedReceptOffDelaySetting this object causes the agent to instruct the UPS to turn off a receptacle after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsReceptOffTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsSwitchedCancelCommand to the value cancel.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.12.2.1.4
lcUpsSwitchedReceptOffTrapDelayWhen 'lcUpsSwitchedReceptOffDelay' reaches a value less than or equal to this object's value, an lcUpsReceptOffWarningTrap will be produced and this object will be reset to 0.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.12.2.1.5
lcUpsSwitchedReceptStatusThe status of the device receptacle. Note that some devices may support Switched of device receptacles as a group only (by using lcUpsSwitchedOutputOffDelay and lcUpsSwitchedOutputOnDelay).ro
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.12.2.1.6
lcUpsSwitchedReceptLabelA user-defined text string associated with a switched receptacle. This may be used to describe the load powered from the receptacle. The text string is stored in non-volatile memory.rw
DisplayString
.1.3.6.1.4.1.476.1.1.1.1.12.2.1.7
luUPStationS
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.2
lsUpsIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.2.1
lsUpsIdentFirmwareVersionThe firmware revision level of the UPS.ro
DisplayString
.1.3.6.1.4.1.476.1.1.1.2.1.1
lsUpsAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.2.6
lsUpsAlarmConditions
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.2.6.1
lsUpsAlarmCheckAirFilter
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.2.6.1.1
lsUpsTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.2.11
lsUpsCheckAirFilterTrapAn lsUpsCheckAirFilterTrap signifies that the programmed time interval for checking the air filter has passed and it is time to check the air filter.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.2.11.0.1
lsUpsConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.2.12
lsUpsConfigBypassInstalledIndicates if a bypass is installed in the UPS.ro
Enumeration
.1.3.6.1.4.1.476.1.1.1.2.12.1
lsUpsBypass
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.2.13
lsUpsOnBypassIndicates that the UPS is currently on bypass.ro
Enumeration
.1.3.6.1.4.1.476.1.1.1.2.13.1
lsUpsBypassFrequencyThe current bypass frequency. (Unit of measure: Hertz)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.2.13.2
lsUpsBypassNumLinesThe number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.2.13.3
lsUpsBypassTable
SEQUENCE OF LsUpsBypassEntry
.1.3.6.1.4.1.476.1.1.1.2.13.4
lsUpsBypassEntry
LsUpsBypassEntry
.1.3.6.1.4.1.476.1.1.1.2.13.4.1
lsUpsBypassLineThe bypass Line.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.2.13.4.1.1
lsUpsBypassVoltageThe bypass voltage. (Unit of measure: Volt)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.2.13.4.1.2
lsUpsBypassCurrentThe bypass current. (Unit of measure: Amp)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.2.13.4.1.3
luUPStationS3
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.7
luExperimental
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.2
luPrivate
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.3