Home/Catalog/LIEBERT-UPSTATION-GXT-UPS-MIB

LIEBERT-UPSTATION-GXT-UPS-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for LIEBERT-UPSTATION-GXT-UPS-MIB.

118
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

118 total
Object Name
emerson
OBJECT IDENTIFIER
.1.3.6.1.4.1.476
RFC1155-SMI
Unknown
.1.3.6.1.4.1.476
liebertCorp
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1
liebertUps
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1
luExtensions
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1
luCore
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1
lcUpsIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.1
lcUpsIdentManufacturerThe UPS manufacturer.ro
DisplayString
.1.3.6.1.4.1.476.1.1.1.1.1.1
lcUpsIdentModelThe UPS Model designation.rw
DisplayString
.1.3.6.1.4.1.476.1.1.1.1.1.2
lcUpsIdentSoftwareVersionThe UPS SNMP Agent software version.ro
DisplayString
.1.3.6.1.4.1.476.1.1.1.1.1.3
lcUpsIdentSpecificA reference to MIB definitions specific to the particular UPS being managed. This object is used to locate the product-specific MIB for this device. If this information is not present, its value should be the OBJECT IDENTIFIER { 0 0 }, which is a syntactically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.1.4
lcUpsIdentFirmwareVersionThe firmware revision level of the UPS.ro
DisplayString
.1.3.6.1.4.1.476.1.1.1.1.1.5
lcUpsIdentSerialNumberThe serial number of the UPS.ro
DisplayString
.1.3.6.1.4.1.476.1.1.1.1.1.6
lcUpsIdentManufactureDateThe date of manufacture of the UPS.ro
DisplayString
.1.3.6.1.4.1.476.1.1.1.1.1.7
lcUpsBattery
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.2
lcUpsBatTimeRemainingThe estimated time to depletion of battery charge. (Unit of measure: Minute)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.2.1
lcUpsBatVoltageThe current battery voltage. (Unit of measure: volt)ro
INTEGER (-32768..32767)
.1.3.6.1.4.1.476.1.1.1.1.2.3
lcUpsBatCapacityThe current battery capacity in percentage of total available.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.2.6
lcUpsInput
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.3
lcUpsInputFrequencyThe current input frequency. (Unit of measure: Hertz)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.3.1
lcUpsInputNumLinesThe number of input lines utilized in this device. This entry indicates the number of rows in the input table.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.3.5
lcUpsInputTable
SEQUENCE OF LcUpsInputEntry
.1.3.6.1.4.1.476.1.1.1.1.3.6
lcUpsInputEntry
LcUpsInputEntry
.1.3.6.1.4.1.476.1.1.1.1.3.6.1
lcUpsInputLineThe input Line.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.3.6.1.1
lcUpsInputVoltageThe input voltage. (Unit of measure: Volt)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.3.6.1.2
lcUpsOutput
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.4
lcUpsOutputFrequencyThe current output frequency. (Unit of measure: Hertz)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.1
lcUpsOutputLoadThe current output load percentage.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.2
lcUpsOutputNumLinesThe number of output lines utilized in this device. This entry indicates the number of rows in the output table.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.3
lcUpsOutputTable
SEQUENCE OF LcUpsOutputEntry
.1.3.6.1.4.1.476.1.1.1.1.4.4
lcUpsOutputEntry
LcUpsOutputEntry
.1.3.6.1.4.1.476.1.1.1.1.4.4.1
lcUpsOutputLineThe output Line.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.4.1.1
lcUpsOutputVoltageThe output voltage. (Unit of measure: Volt)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.4.1.2
lcUpsOutputCurrentThe output current. (Unit of measure: Amp)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.4.1.3
lcUpsOutputWattsThe output power in watts.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.4.5
lcUpsInverter
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.5
lcUpsInverterStatusThe state of the inverter. Unknown is returned if the state can not be determined.ro
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.5.1
lcUpsAlarm
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6
lcUpsAlarmsThe current number of alarm conditions.ro
Gauge
.1.3.6.1.4.1.476.1.1.1.1.6.1
lcUpsAlarmTable
SEQUENCE OF LcUpsAlarmEntry
.1.3.6.1.4.1.476.1.1.1.1.6.2
lcUpsAlarmEntry
LcUpsAlarmEntry
.1.3.6.1.4.1.476.1.1.1.1.6.2.1
lcUpsAlarmIdA unique identifier for an alarm condition. This value must remain constant between agent initializations.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.6.2.1.1
lcUpsAlarmDescrA reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.2.1.2
lcUpsAlarmTimeThe value of sysUpTime when the alarm condition occured.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.476.1.1.1.1.6.2.1.3
lcUpsAlarmConditions
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3
lcUpsAlarmLowBatteryWarning
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.1
lcUpsAlarmLowBatteryShutdown
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.2
lcUpsAlarmUtilFailed
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.3
lcUpsAlarmOverTempWarning
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.4
lcUpsAlarmOverTempShutdown
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.5
lcUpsAlarmOutputOverloadWarning
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.6
lcUpsAlarmOutputOverloadShutdown
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.7
lcUpsAlarmInputOverVoltage
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.8
lcUpsAlarmBatteryBad
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.9
lcUpsAlarmOnBattery
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.10
lcUpsAlarmStopNoticeIssued
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.11
lcUpsAlarmUpsOff
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.12
lcUpsAlarmInputFreqError
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.13
lcUpsAlarmOutputUnderVoltage
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.15
lcUpsAlarmOutputOverVoltage
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.16
lcUpsBadBypassPower
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.6.3.17
lcUpsTest
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.7
lcUpsTestBatterySetting this variable to 'start' will initiate the battery test. Setting this variable to 'abort' will stop the battery test if the test is in- progress, otherwise it has no effect. Setting this variable to 'unknown' has no effect. Reading this variable will always result in a return value of 'unknown'. If 'lcUpsTestBatteryStatus' is 'failed' the test may not be performed again and the status will remain in the failure state.rw
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.7.1
lcUpsTestBatteryStatusThe status of the battery test.ro
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.7.2
lcUpsControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.8
lcUpsControlOutputOffDelaySetting this object causes the agent to instruct the UPS to turn off the output after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsOutputOffTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value cancel.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.1
lcUpsControlOutputOnDelaySetting this object causes the agent to instruct the UPS to turn on the output after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsOutputOnTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value cancel.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.2
lcUpsControlOutputOffTrapDelayWhen 'lcUpsControlOutputOffDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOffWarningTrap will be produced and this object will be reset to 0.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.3
lcUpsControlOutputOnTrapDelayWhen 'lcUpsControlOutputOnDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOnWarningTrap will be produced and this object will be reset to 0.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.4
lcUpsControlUnixShutdownDelaySetting this object causes the agent to instruct the UPS to perform a UNIX Shutdown in the indicated number of seconds. The agent counts down the number of seconds until the event will take place. A Unix shutdown is only valid if the UPS is on Battery. During a UNIX Shutdown, the UPS will turn off the output even if the Utility comes back on line before the shutdown time arrives. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value 'cancel'.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.5
lcUpsControlUnixShutdownTrapDelayWhen 'lcUpsControlUnixShutdownDelay' reaches a value less than or equal to this object's value, an lcUpsUnixShutdownWarningTrap will be produced and this object will be reset to 0.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.6
lcUpsControlCancelCommandsSetting this variable to 'cancel' will cause the agent to issue instructions to the UPS to cancel all outstanding commands, such as lcUpsControlOutputOff, lcUpsControlOutputOn, lcUpsControlUnixShutdown.rw
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.8.7
lcUpsControlRebootAgentDelaySetting this object causes the agent to reboot after the indicated number of seconds have expired. The value will count down until the event takes place. The command can be cancelled by setting lcUpsControlCancleCommand to the value cancel.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.8.8
lcUpsNominal
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.9
lcUpsNominalOutputVoltageThe nominal output voltage. (Unit of measure: volt)rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.9.1
lcUpsNominalInputVoltageThe nominal input voltage. (Unit of measure: volt)rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.9.2
lcUpsNominalOutputFreqThe nominal output frequency. (Unit of measure: Hertz)rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.9.5
lcUpsNominalInputFreqThe nominal input frequency. (Unit of measure: Hertz)rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.9.6
lcUpsNominalOutputVaRatingThe nominal Volt-Amp rating.rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.9.7
lcUpsNominalOutputWattsRatingThe nominal power rating. (Unit of measure: watt)rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.9.8
lcUpsTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.11
lcUpsOverloadWarningTrapAn lcUpsOverloadWarningTrap signifies that the UPS has detected an Overload condition where the output load has exceeded the UPS's rated capacity.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.1
lcUpsOverloadShutdownTrapAn lcUpsOverloadShutdownTrap signifies that the UPS has detected an Overload condition where the output load has exceeded the UPS's rated capacity and has shut off the output.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.2
lcUpsOnBatteryTrapAn lcUpsOnBatteryTrap signifies that the UPS is currently on Battery Power.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.3
lcUpsLowBatteryWarningTrapAn lcUpsLowBatteryWarningTrap signifies that the UPS has entered a Low Battery state.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.4
lcUpsLowBatteryShutdownTrapAn lcUpsLowBatteryShutdownTrap signifies that the UPS has shut off the output due to a Low Battery state.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.5
lcUpsUtilPowerFailedTrapAn lcUpsUtilPowerFailedTrap signifies that the utility power input to the UPS has been lost.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.6
lcUpsUtilPowerRestoredTrapAn lcUpsUtilPowerRestoredTrap signifies that the utility power has been restored to the UPS.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.7
lcUpsInputOverVoltageTrapAn lcUpsInputOverVoltageTrap signifies that the UPS has detected a high input voltage condition.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.8
lcUpsOverTempWarningTrapAn lcUpsOverTempWarningTrap signifies that the UPS has detected a excessive temperature condition.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.9
lcUpsOverTempShutdownTrapAn lcUpsOverTempShutdownTrap signifies that the UPS has detected a excessive temperature condition and shut off the output.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.10
lcUpsAlarmTrapAn Alarm condition has occurred and is being reported in the lcUpsAlarmTable.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.11
lcUpsOutputOffTrapAn lcUpsOutputOffTrap is sent when the UPS turns all of its output off, either at the inverter or via a relay.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.12
lcUpsOutputOffWarningTrapAn lcUpsOutputOffWarningTrap is sent when the lcUpsControlOutputOffDelay reaches the value of lcUpsControlOutputOffTrapDelay.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.13
lcUpsOutputOnTrapAn lcUpsOutputOnTrap is sent when the UPS turns all of its output back on, either at the inverter or via a relay.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.14
lcUpsOutputOnWarningTrapAn lcUpsOutputOnWarningTrap is sent when the lcUpsControlOutputOnDelay reaches the value of lcUpsControlOutputOnTrapDelay.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.15
lcUpsUnixShutdownTrapAn lcUpsUnixShutodwnTrap is sent 2 seconds before the UPS is scheduled to perform a Unix Shutdown.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.16
lcUpsUnixShutdownWarningTrapAn lcUpsUnixShutdownWarningTrap is sent when the lcUpsControlUnixShudownDelay reaches the value of lcUpsControlUnixShutdownTrapDelay.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.17
lcUpsInputFreqErrorTrapAn ldUpsInputFreqErrorTrap signifies that the UPS has detected that input frequency is outside tolerable variance.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.22
lcUpsOutputOverVoltageTrapAn lcUpsOutputOverVoltageTrap signifies that the UPS has detected that the output voltage is too high.
TRAP-TYPE
.1.3.6.1.4.1.476.1.1.1.1.11.0.24
lcUpsBypass
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.13
lcUpsOnBypassIndicates that the UPS is currently on bypass.ro
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.13.1
lcUpsBypassFrequencyThe current bypass frequency. (Unit of measure: Hertz)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.13.2
lcUpsBypassNumLinesThe number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.13.3
lcUpsBypassTable
SEQUENCE OF LcUpsBypassEntry
.1.3.6.1.4.1.476.1.1.1.1.13.4
lcUpsBypassEntry
LcUpsBypassEntry
.1.3.6.1.4.1.476.1.1.1.1.13.4.1
lcUpsBypassLineThe bypass Line.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.13.4.1.1
lcUpsBypassVoltageThe bypass voltage. (Unit of measure: Volt)ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.13.4.1.2
lcUpsConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.1.14
lcUpsConfigTypeIndicates the UPS topology.ro
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.14.1
lcUpsConfigBypassInstalledIndicates if a bypass is installed in the UPS.ro
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.14.2
lcUpsConfigModuleCountA number identifying how many multi-module UPS are connected to the System Control Cabinet.ro
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.14.3
lcUpsConfigAudibleStatusThe requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm.rw
Enumeration
.1.3.6.1.4.1.476.1.1.1.1.14.5
lcUpsConfigLowBattTimeThe value of lcUpsBatTimeRemaining at which a lowBatteryWarning condition is declared. (Unit of measure: Minute)rw
INTEGER
.1.3.6.1.4.1.476.1.1.1.1.14.6
lcUpsConfigAutoRestartSetting this object will start the output after the indicated number of ticks (1 tick = 10 seconds), including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will disable autorestart.rw
INTEGER (-1..32767)
.1.3.6.1.4.1.476.1.1.1.1.14.7
luUPStationGxt
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.1.14
luExperimental
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.2
luPrivate
OBJECT IDENTIFIER
.1.3.6.1.4.1.476.1.1.3