LIEBERT-GP-SYSTEM-MIB
The LIEBERT-GP-SYSTEM-MIB provides SNMP management objects for monitoring and controlling Liebert GP-series precision cooling and power distribution units, exposing system status, environmental sensor data, and operational parameters.
Imported Objects
Objects
11 total| Object Name |
|---|
liebertSystemModuleThe MIB module used to specify Liebert Controller OIDs Copyright 2000-2004 Liebert Corporation. All rights reserved. Reproduction of this document is authorized on the condition that the forgoing copyright notice is included. This Specification is supplied 'AS IS' and Liebert Corporation makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification. MODULE-IDENTITY .1.3.6.1.4.1.476.1.42.1.8.1 |
lgpSysStatisticsThis sub-tree is used to register Liebert System Statistics object identifiers. OBJECT IDENTIFIER .1.3.6.1.4.1.476.1.42.3.7.1 |
lgpSysStatisticsRunHrsAccumulated run hours of the system.ro Unsigned32 UNITS "hours" .1.3.6.1.4.1.476.1.42.3.7.1.1 |
lgpSysStatusThis sub-tree is used to register Liebert System Status object identifiers. OBJECT IDENTIFIER .1.3.6.1.4.1.476.1.42.3.7.2 |
lgpSysSelfTestResultThe outcome of the previous self-test.ro Enumeration .1.3.6.1.4.1.476.1.42.3.7.2.1 |
lgpSysSettingsThis sub-tree is used to register Liebert System Settings object identifiers. OBJECT IDENTIFIER .1.3.6.1.4.1.476.1.42.3.7.3 |
lgpSysAudibleAlarmThe state of the audible alarm of the device.rw Enumeration .1.3.6.1.4.1.476.1.42.3.7.3.1 |
lgpSysControlThis sub-tree is used to register Liebert System Control object identifiers. OBJECT IDENTIFIER .1.3.6.1.4.1.476.1.42.3.7.4 |
lgpSysSelfTestSelf-Test Command. This command will initiate a system self-test of the system. If already initiated, this command will abort the self-test. This command should be sent with a parameter of 1. This variable doesn't return a value when read.rw Integer32 .1.3.6.1.4.1.476.1.42.3.7.4.1 |
lgpSysTimeThis sub-tree is used to register Liebert System Time object identifiers. OBJECT IDENTIFIER .1.3.6.1.4.1.476.1.42.3.7.5 |
lgpSysTimeEpochThe present time of the system. This time is represented as the number of seconds, or ticks, since the epoch of 1970-01-01 00:00:00 GMT.rw Unsigned32 UNITS "seconds or ticks" .1.3.6.1.4.1.476.1.42.3.7.5.1 |
More MIBs from Liebert
Browse all LiebertMIBs →The LIEBERT-GP-FLEXIBLE-CONDITIONS-MIB enables SNMP-based monitoring and management of Liebert GP series power and environmental control units, specifically exposing configurable alarm thresholds and conditional logic states for critical infrastructure parameters. This module facilitates the retrieval of dynamic condition variables and event triggers to automate fault detection and response within data center power distribution and cooling systems.
The LIEBERT-GP-CONDITIONS-MIB defines the Liebert-specific Object Identifiers required to monitor environmental conditions and operational states of Liebert GP series power and cooling infrastructure. This module enables the retrieval of critical telemetry data, including temperature, humidity, and alarm status, from Liebert network management agents via the SNMP protocol.
The LIEBERT-GP-ENVIRONMENTAL-MIB enables SNMP-based monitoring of Liebert GP-series precision cooling units and environmental control systems, specifically exposing metrics for temperature, humidity, airflow, and alarm states. This module facilitates the collection of critical facility infrastructure data required for data center thermal management and environmental fault detection.
Standard SNMP MIB module defining data structures for LIEBERT-UPS-MIB.
The LIEBERT-GP-POWER-MIB enables SNMP monitoring of Liebert GP-series power distribution units and UPS systems, exposing critical metrics such as input/output voltage, current, frequency, load percentage, battery status, and alarm conditions. This module facilitates real-time telemetry collection for power infrastructure health assessment and fault detection within data center environments.
SNMP MIB module