LIEBERT-GP-CONTROLLER-MIB
The LIEBERT-GP-CONTROLLER-MIB provides SNMP management interfaces for Liebert GP-series precision cooling and power distribution controllers, exposing operational status, environmental sensor readings, and alarm states. This module enables the monitoring of critical data center infrastructure metrics such as compressor status, fan speeds, temperature differentials, and system fault conditions via standard OIDs.
Imported Objects
Objects
6 total| Object Name |
|---|
liebertControllerModuleThe MIB module used to specify Liebert Controller OIDs Copyright 2000-2008 Liebert Corporation. All rights reserved. Reproduction of this document is authorized on the condition that the forgoing copyright notice is included. This Specification is supplied 'AS IS' and Liebert Corporation makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification. MODULE-IDENTITY .1.3.6.1.4.1.476.1.42.1.7.1 |
lgpCtrlNumberInstalledControlModulesThe number of control modules installed in the device.ro Integer32 .1.3.6.1.4.1.476.1.42.3.6.1 |
lgpCtrlNumberFailedControlModulesThe number of control modules in the device that have failed.ro Integer32 .1.3.6.1.4.1.476.1.42.3.6.2 |
lgpCtrlNumberRedundantControlModulesThe number of redundant control modules installed in the device.ro Integer32 .1.3.6.1.4.1.476.1.42.3.6.3 |
lgpCtrlNumberControlModuleWarningsThe number of control modules in the device that have a warning.ro Integer32 .1.3.6.1.4.1.476.1.42.3.6.5 |
lgpCtrlBoardBatteryVoltageThe control board battery voltage. Typically this battery is used to provide backup power to memory and other vital circuits.ro Unsigned32 UNITS ".01 Volts" .1.3.6.1.4.1.476.1.42.3.6.6 |
More MIBs from Liebert
Browse all LiebertMIBs →The LIEBERT-GP-FLEXIBLE-CONDITIONS-MIB enables SNMP-based monitoring and management of Liebert GP series power and environmental control units, specifically exposing configurable alarm thresholds and conditional logic states for critical infrastructure parameters. This module facilitates the retrieval of dynamic condition variables and event triggers to automate fault detection and response within data center power distribution and cooling systems.
The LIEBERT-GP-CONDITIONS-MIB defines the Liebert-specific Object Identifiers required to monitor environmental conditions and operational states of Liebert GP series power and cooling infrastructure. This module enables the retrieval of critical telemetry data, including temperature, humidity, and alarm status, from Liebert network management agents via the SNMP protocol.
The LIEBERT-GP-ENVIRONMENTAL-MIB enables SNMP-based monitoring of Liebert GP-series precision cooling units and environmental control systems, specifically exposing metrics for temperature, humidity, airflow, and alarm states. This module facilitates the collection of critical facility infrastructure data required for data center thermal management and environmental fault detection.
Standard SNMP MIB module defining data structures for LIEBERT-UPS-MIB.
The LIEBERT-GP-POWER-MIB enables SNMP monitoring of Liebert GP-series power distribution units and UPS systems, exposing critical metrics such as input/output voltage, current, frequency, load percentage, battery status, and alarm conditions. This module facilitates real-time telemetry collection for power infrastructure health assessment and fault detection within data center environments.
SNMP MIB module