INNOVX-DTE-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
18
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
18 total| Object Name |
|---|
dteAdmin OBJECT IDENTIFIER .1.3.6.1.4.1.498.22.1.6.1 |
IMPORTS Unknown .1.3.6.1.4.1.498.22.1.6.1 |
dtesMIBversionIdentifies the version of the MIB as `X.YZT' where:
X: Major Revision (1-9)
Y: Minor Revision (0-9)
Z: Typographical Revision (0-9)
T: Test Revision (A-Z)
Upon formal release, the test revision will not be present.ro DisplayString .1.3.6.1.4.1.498.22.1.6.1.1 |
dteCfg OBJECT IDENTIFIER .1.3.6.1.4.1.498.22.1.6.2 |
dteInterfaceTypeDefines the DTE Interface Type.
WEBFLAG
V.28
V.35
RS-449
EIA-530
EIA-530A
X.21
WEBENDrw Enumeration .1.3.6.1.4.1.498.22.1.6.2.1 |
dteTxInvertingTimingnormal(1) tx timing clocks the transmit data from the DTE using
an internal generated clock. invert (2) Invert Internally generated
transmit clock used to sample the transmit data from the DTE.
external(3) uses the DTE clock, EXTCLK, to clock the transmit data
from the DTE.
WEBFLAG
Slave Normal
Slave Inverted
External
WEBENDrw Enumeration .1.3.6.1.4.1.498.22.1.6.2.2 |
dteRxCarrierThe Receive Carrier option. This option controls the operation of DCD.
WEBFLAG
Forced On
Normal Operation
WEBENDrw Enumeration .1.3.6.1.4.1.498.22.1.6.2.3 |
dteDsrControlThe DSR option. This option controls the operation of DSR.
When forcedOn(1) is selected, DSR is normally on,
if set for followsDTR(2) then DSR is on only when DTR is on.
WEBFLAG
Forced On
Follows DTR
WEBENDrw Enumeration .1.3.6.1.4.1.498.22.1.6.2.4 |
dteAlarmCfg OBJECT IDENTIFIER .1.3.6.1.4.1.498.22.1.6.3 |
dteDtrLossTrapSeverityControls the reporting and defines the severity of the Channel Data
Terminal Ready Loss Alarm when this event occurs.
WEBFLAG
Inhibit
Critical
Major
Minor
Warning
Info
WEBENDrw Enumeration .1.3.6.1.4.1.498.22.1.6.3.1 |
dteDiagnostics OBJECT IDENTIFIER .1.3.6.1.4.1.498.22.1.6.4 |
dteLoopbackControl the DTE loopback to the channel. noTest(1) stops
the test. toChan(2) starts a loopback toward the DTE.rw Enumeration .1.3.6.1.4.1.498.22.1.6.4.1 |
dteDiagTestDurationDefines the length of the diagnostic test.rw Enumeration .1.3.6.1.4.1.498.22.1.6.4.2 |
dteDiagTestStatusDisplays the test in progress, if any.ro Enumeration .1.3.6.1.4.1.498.22.1.6.4.3 |
dteStatus OBJECT IDENTIFIER .1.3.6.1.4.1.498.22.1.6.5 |
dteLedStatusA bitwise snapshot of the front panel LED states,
where 0 = LED off and 1 = LED on, as follows:
LED description
Octet 1 bit 7 - n/u
bit 6 - n/u
bit 5 - n/u
bit 4 - n/u
bit 3 - n/u
bit 2 - DTE LMI LMI traffic on DTE
bit 1 - SD EQP send data - equipment traffic
bit 0 - RD EQP receive data - equipment trafficro OCTET STRING .1.3.6.1.4.1.498.22.1.6.5.1 |
dtePortStatusA bitwise snapshot of interface port status conditions and EIA signals,
where 0 = condition not present, and 1 = condition present, as follows:
Octet 1 - DTE Interface Port Status
bit 7 - n/u
bit 6 - n/u
bit 5 - n/u
bit 4 - n/u
bit 3 - n/u
bit 2 - Transmit Activity
bit 1 - Receive Activity
bit 0 - DTR Lossro OCTET STRING .1.3.6.1.4.1.498.22.1.6.5.2 |
dtePortFrameCountsThe total number of frames transmitted and received on each interface
port. This object will be reset to zero after a read, and after power up,
soft reset, or factory defaults reset.
Octet 1 - DTE Interface Transmit Frame Count Octet 2
bit 7 - 2^15 bit 7 - 2^7
bit 6 - 2^14 bit 6 - 2^6
bit 5 - 2^13 bit 5 - 2^5
bit 4 - 2^12 bit 4 - 2^4
bit 3 - 2^11 bit 3 - 2^3
bit 2 - 2^10 bit 2 - 2^2
bit 1 - 2^9 bit 1 - 2^1
bit 0 - 2^8 bit 0 - 2^0
Octet 3 - DTE Interface Receive Frame Count Octet 4
bit 7 - 2^15 bit 7 - 2^7
bit 6 - 2^14 bit 6 - 2^6
bit 5 - 2^13 bit 5 - 2^5
bit 4 - 2^12 bit 4 - 2^4
bit 3 - 2^11 bit 3 - 2^3
bit 2 - 2^10 bit 2 - 2^2
bit 1 - 2^9 bit 1 - 2^1
bit 0 - 2^8 bit 0 - 2^0ro OCTET STRING .1.3.6.1.4.1.498.22.1.6.5.3 |