Home/Catalog/HUAWEI-POWER-MIB

HUAWEI-POWER-MIB

AI MIB Summary

The HUAWEI-POWER-MIB module enables SNMP-based monitoring of power supply unit status, input/output voltage levels, current draw, and temperature metrics on Huawei networking hardware. It facilitates granular fault detection and capacity planning by exposing real-time power consumption and redundancy state data for network devices.

This MIB is used for defining Power Monitor management MIB objects.
Main OID:
hwPower.1.3.6.1.4.1.2011.6.2
261
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

261 total
Object Name
hwPower
MODULE-IDENTITY
.1.3.6.1.4.1.2011.6.2
hwPowerMonObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.2.1
hwPowerSysInfoTable
SEQUENCE OF HwPowerSysInfoEntry
.1.3.6.1.4.1.2011.6.2.1.1
hwPowerSysInfoEntry
HwPowerSysInfoEntry
.1.3.6.1.4.1.2011.6.2.1.1.1
hwPowerIndexro
Integer32
.1.3.6.1.4.1.2011.6.2.1.1.1.1
hwPowerTyperw
Enumeration
.1.3.6.1.4.1.2011.6.2.1.1.1.2
hwPowerNamerw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.2.1.1.1.3
hwPowerStatero
Enumeration
.1.3.6.1.4.1.2011.6.2.1.1.1.4
hwPowerRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.2.1.1.1.5
hwPowerControlModerw
Enumeration
.1.3.6.1.4.1.2011.6.2.1.1.1.6
hwPowerRemoteFrameIDrw
Integer32
.1.3.6.1.4.1.2011.6.2.1.1.1.7
hwPowerProtectrw
Enumeration
.1.3.6.1.4.1.2011.6.2.1.1.1.8
hwPowerVersionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.2.1.1.1.9
hwPowerSupplyStatero
Enumeration
.1.3.6.1.4.1.2011.6.2.1.1.1.10
hwACInputTable
SEQUENCE OF HwACInputEntry
.1.3.6.1.4.1.2011.6.2.1.2
hwACInputEntry
HwACInputEntry
.1.3.6.1.4.1.2011.6.2.1.2.1
hwACLoopIndexro
Integer32
.1.3.6.1.4.1.2011.6.2.1.2.1.1
hwACPowerStatero
Enumeration
.1.3.6.1.4.1.2011.6.2.1.2.1.2
hwACVoltAro
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.2.1.3
hwACCurrentAro
MeasuresRange UNITS "mA"
.1.3.6.1.4.1.2011.6.2.1.2.1.4
hwACVoltBro
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.2.1.5
hwACCurrentBro
MeasuresRange UNITS "mA"
.1.3.6.1.4.1.2011.6.2.1.2.1.6
hwACVoltCro
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.2.1.7
hwACCurrentCro
MeasuresRange UNITS "mA"
.1.3.6.1.4.1.2011.6.2.1.2.1.8
hwACVoltageHighrw
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.2.1.9
hwACVoltageLowrw
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.2.1.10
hwACRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.2.1.2.1.11
hwACVoltageAStatero
Enumeration
.1.3.6.1.4.1.2011.6.2.1.2.1.12
hwACVoltageBStatero
Enumeration
.1.3.6.1.4.1.2011.6.2.1.2.1.13
hwACVoltageCStatero
Enumeration
.1.3.6.1.4.1.2011.6.2.1.2.1.14
hwDCOutTable
SEQUENCE OF HwDCOutEntry
.1.3.6.1.4.1.2011.6.2.1.3
hwDCOutEntry
HwDCOutEntry
.1.3.6.1.4.1.2011.6.2.1.3.1
hwDCVoltageOutro
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.3.1.1
hwDCCurrentOutro
MeasuresRange UNITS "mA"
.1.3.6.1.4.1.2011.6.2.1.3.1.2
hwDCVoltageOutHighrw
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.3.1.3
hwDCVoltageOutLowrw
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.3.1.4
hwDCVoltageOutStaterodeprecated
Enumeration
.1.3.6.1.4.1.2011.6.2.1.3.1.5
hwDCCurrentOutHighrw
MeasuresRange UNITS "mA"
.1.3.6.1.4.1.2011.6.2.1.3.1.6
hwDCCurrentOutLowrw
MeasuresRange UNITS "mA"
.1.3.6.1.4.1.2011.6.2.1.3.1.7
hwDCCurrentOutStaterodeprecated
Enumeration
.1.3.6.1.4.1.2011.6.2.1.3.1.8
hwDCOutRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.2.1.3.1.9
hwDCOutLoadCurrentro
MeasuresRange UNITS "mA"
.1.3.6.1.4.1.2011.6.2.1.3.1.10
hwDCOutLoadTmpHighrw
MeasuresRange UNITS "0.01 degree"
.1.3.6.1.4.1.2011.6.2.1.3.1.11
hwDCOutRunStatero
Bits
.1.3.6.1.4.1.2011.6.2.1.3.1.12
hwDCCommunicationStatero
Enumeration
.1.3.6.1.4.1.2011.6.2.1.3.1.13
hwLoadinfoTable
SEQUENCE OF HwLoadinfoEntry
.1.3.6.1.4.1.2011.6.2.1.4
hwLoadinfoEntry
HwLoadinfoEntry
.1.3.6.1.4.1.2011.6.2.1.4.1
hwLoadIndexro
Integer32
.1.3.6.1.4.1.2011.6.2.1.4.1.1
hwLoadInfoAdminStaterw
Enumeration
.1.3.6.1.4.1.2011.6.2.1.4.1.2
hwLoadInfoOperStatusro
Enumeration
.1.3.6.1.4.1.2011.6.2.1.4.1.3
hwLoadCurrentro
MeasuresRange UNITS "mA"
.1.3.6.1.4.1.2011.6.2.1.4.1.4
hwLoadVoltagero
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.4.1.5
hwLoadVoltageHighrw
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.4.1.6
hwLoadLoadNamerw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.2.1.4.1.7
hwLoadInfoRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.2.1.4.1.8
hwLoadFuseStatero
Enumeration
.1.3.6.1.4.1.2011.6.2.1.4.1.9
hwLoadHoreIndexrw
Integer32
.1.3.6.1.4.1.2011.6.2.1.4.1.10
hwRectifierTable
SEQUENCE OF HwRectifierEntry
.1.3.6.1.4.1.2011.6.2.1.5
hwRectifierEntry
HwRectifierEntry
.1.3.6.1.4.1.2011.6.2.1.5.1
hwRectifierIndexro
Integer32
.1.3.6.1.4.1.2011.6.2.1.5.1.1
hwRectifierAdminStaterw
Enumeration
.1.3.6.1.4.1.2011.6.2.1.5.1.2
hwRectifierOperStatero
Enumeration
.1.3.6.1.4.1.2011.6.2.1.5.1.3
hwRectifierVoltagero
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.5.1.4
hwRectifierCurrentro
MeasuresRange UNITS "mA"
.1.3.6.1.4.1.2011.6.2.1.5.1.5
hwRectifierRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.2.1.5.1.6
hwRectifierCurrentLimitrw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.2.1.5.1.7
hwRectifierRunStatero
Bits
.1.3.6.1.4.1.2011.6.2.1.5.1.8
hwRectifierChargeStatero
Enumeration
.1.3.6.1.4.1.2011.6.2.1.5.1.9
hwBatteryGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.2.1.6
hwBatteryGroupTable
SEQUENCE OF HwBatteryGroupEntry
.1.3.6.1.4.1.2011.6.2.1.6.1
hwBatteryGroupEntry
HwBatteryGroupEntry
.1.3.6.1.4.1.2011.6.2.1.6.1.1
hwBatteryGroupCapacityro
Integer32
.1.3.6.1.4.1.2011.6.2.1.6.1.1.1
hwBatteryGroupCapcaityRemainro
Integer32 (-1..100)
.1.3.6.1.4.1.2011.6.2.1.6.1.1.2
hwBatteryGroupsrw
Integer32
.1.3.6.1.4.1.2011.6.2.1.6.1.1.3
hwBatteryGroupVoltageLowrw
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.6.1.1.4
hwBatteryGroupChargeLimitrw
MeasuresRange UNITS "percent"
.1.3.6.1.4.1.2011.6.2.1.6.1.1.5
hwBatteryGroupRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.2.1.6.1.1.6
hwBatteryGroupOperStatusro
Enumeration
.1.3.6.1.4.1.2011.6.2.1.6.1.1.7
hwBatteryGroupVoltageHighrw
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.6.1.1.8
hwBatteryGroupTwiceOffVoltagerw
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.6.1.1.9
hwBatteryGroupProtectVoltagerw
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.6.1.1.10
hwBatteryGroupTmpOffHighrw
MeasuresRange UNITS "0.01 degree"
.1.3.6.1.4.1.2011.6.2.1.6.1.1.11
hwBatteryInstallTimero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.2.1.6.1.1.12
hwBatteryGroupBomCoderw
OCTET STRING
.1.3.6.1.4.1.2011.6.2.1.6.1.1.13
hwChargeTable
SEQUENCE OF HwChargeEntry
.1.3.6.1.4.1.2011.6.2.1.6.2
hwChargeEntry
HwChargeEntry
.1.3.6.1.4.1.2011.6.2.1.6.2.1
hwChargeAdminStatusrw
Enumeration
.1.3.6.1.4.1.2011.6.2.1.6.2.1.1
hwChargeOperStatusro
Enumeration
.1.3.6.1.4.1.2011.6.2.1.6.2.1.2
hwAverageChargeVoltagerw
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.6.2.1.3
hwFloatChargeVoltagerw
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.6.2.1.4
hwChargeControlRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.2.1.6.2.1.5
hwAverageChargeTimerw
Integer32 UNITS "day"
.1.3.6.1.4.1.2011.6.2.1.6.2.1.6
hwBatteryTmpRedeemingQuotietyrw
Integer32
.1.3.6.1.4.1.2011.6.2.1.6.2.1.7
hwBatteryTable
SEQUENCE OF HwBatteryEntry
.1.3.6.1.4.1.2011.6.2.1.6.3
hwBatteryEntry
HwBatteryEntry
.1.3.6.1.4.1.2011.6.2.1.6.3.1
hwBatteryIndexro
Integer32
.1.3.6.1.4.1.2011.6.2.1.6.3.1.1
hwBatteryCapacityrw
Integer32
.1.3.6.1.4.1.2011.6.2.1.6.3.1.2
hwBatteryLoopStatero
Enumeration
.1.3.6.1.4.1.2011.6.2.1.6.3.1.3
hwBatteryVoltagero
MeasuresRange UNITS "mV"
.1.3.6.1.4.1.2011.6.2.1.6.3.1.4
hwBatteryStatero
Enumeration
.1.3.6.1.4.1.2011.6.2.1.6.3.1.5
Showing 100 of 261 OID objects

HUAWEI-POWER-MIB Technical Reference Overview

The HUAWEI-POWER-MIB SNMP MIB module published by Huawei defines 261 managed OID objects, including 128 scalar/column metrics, 12 SNMP tables, and 95 trap/notification events anchored at base OID .1.3.6.1.4.1.2011.6.2. Key tabular structures include hwPowerSysInfoTable, hwACInputTable, hwDCOutTable, hwLoadinfoTable, hwRectifierTable, hwBatteryGroupTable. Monitored SNMP traps/notifications include powerConnFaultAlarm, powerConnFaultAlarmResume, acInputVoltageAlarm, acInputVoltageAlarmResume, acInputVoltageHighAlarm, acInputVoltageHighAlarmResume.

Key OID Definitions in HUAWEI-POWER-MIB

hwPowerMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.2011.6.2

This MIB is used for defining Power Monitor management MIB objects.

hwPowerSysInfoTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.6.2.1.1

Power basic information table. The indexes of this table are hwEnvEmuIndex and hwPowerIndex. hwEnvEmuIndex comes from hwEnvironmentInfoTable and is the index of the monitoring unit. hwPowerIndex is the index of the power supply monitored by the monitoring unit.

hwACInputTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.6.2.1.2

AC input table. Through this table, AC input monitoring parameters of 4875 power supply, 4845 power supply, 4810 power supply, 48100 power supply, and 48240 power supply can be set and queried. The indexes of this table are hwEnvEmuIndex, hwPowerIndex, and hwACLoopIndex. hwEnvEmuIndex is the index of the monitoring unit. hwPowerIndex is the index of the power supply monitored by the monitoring unit. hwACLoopIndex is the index of the AC input power supply monitored by the monitoring unit.

hwDCOutTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.6.2.1.3

DC output table. Through this table, DC output monitoring parameters of 4875 power supply, 4845 power supply, 4810 power supply, 482400 power supply, and 48100 power supply can be set and queried. The indexes of this table are hwEnvEmuIndex and hwPowerIndex. hwEnvEmuIndex, which comes from hwEnvironmentInfoTable, is the index of the monitored unit. hwPowerIndex is the index of the power supply monitored by the monitoring unit.

hwLoadinfoTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.6.2.1.4

Load information table. Through this table, the load parameter can be set and queried. The indexes of this table are hwEnvEmuIndex, hwPowerIndex, and hwLoadIndex. hwEnvEmuIndex, which comes from hwEnvironmentInfoTable, is the index of the monitored unit. hwPowerIndex is the index of the power supply monitored by the monitoring unit. hwLoadIndex is the index of the monitored load.

hwRectifierTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.6.2.1.5

Rectifier module table. Through this table, the status information of the rectifier module can be set and queried. The indexes of this table are hwEnvEmuIndex, hwPowerIndex, and hwRectifierIndex. hwEnvEmuIndex, which comes from hwEnvironmentInfoTable, is the index of the monitored unit. hwPowerIndex is the index of the power supply monitored by the monitoring unit. hwRectifierIndex is the index of the monitored rectifier module under the power supply.

hwBatteryGroupTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.6.2.1.6.1

Basic information table of battery group. The indexes of this table are hwEnvEmuIndex and hwPowerIndex. hwEnvEmuIndex is the index of the monitored unit, and hwPowerIndex is the index of the power supply monitored by the monitoring unit.

hwChargeTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.6.2.1.6.2

Charge management table. Through this table, the charging parameter of the battery can be set and queried. The indexes of this table are hwEnvEmuIndex and hwPowerIndex. hwEnvEmuIndex is the index of the monitored unit, and hwPowerIndex is the index of the power supply monitored by the monitoring unit.

hwBatteryTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.6.2.1.6.3

Battery group state table. Through this table, the status parameter of a battery group can be set and queried. The indexes of this table are hwEnvEmuIndex, hwPowerIndex, and hwBatteryIndex. hwEnvEmuIndex is the index of the monitored unit. hwPowerIndex is the index of the power supply monitored by the monitoring unit. hwBatteryIndex is the index of the monitored battery group.

hwBatteryTestTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.6.2.1.6.4

Battery test table. The indexes of this table are hwEnvEmuIndex and hwPowerIndex. hwEnvEmuIndex is the index of the monitored unit, and hwPowerIndex is the index of the power supply monitored by the monitoring unit.

hwBatteryLogTestTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.6.2.1.6.5

Battery test result table, Through this table, the discharging test result of the battery group can be saved and queried. The indexes of this table are hwEnvEmuIndex, hwPowerIndex, and hwBatteryLogTestIndex. hwEnvEmuIndex is the index of the monitored unit. hwPowerIndex is the index of the power supply monitored by the monitoring unit. hwBatteryLogTestIndex is the index of the monitored battery.

hwRemoteProvidePowerInfoTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.6.2.1.7

Remote provide power basic information table. The indexes of this table are hwEnvEmuIndex and hwPowerIndex. hwEnvEmuIndex is the index of the monitored unit, and hwPowerIndex is the index of the power supply monitored by the monitoring unit.

hwACInfomationTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.6.2.1.8

AC infomation table. The table is not supported. The indexes of this table are hwEnvEmuIndex and hwPowerIndex.

powerConnFaultAlarmNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.6.2.2.2.0.1

This trap message is reported when the communication between the power module and the monitoring board is fault.

powerConnFaultAlarmResumeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.6.2.2.2.0.2

This trap message is reported when the communication between the power module and the monitoring board resumes.

acInputVoltageAlarmNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.6.2.2.2.0.3

This trap message is reported when there is a exception of AC input voltage.

acInputVoltageAlarmResumeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.6.2.2.2.0.4

This trap message is reported when the state of AC input voltage resumes.

acInputVoltageHighAlarmNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.6.2.2.2.0.5

This trap message is reported when the input voltage is too high.

acInputVoltageHighAlarmResumeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.6.2.2.2.0.6

This trap message is reported when the input voltage resumes to the normal range from a high value.

acInputVoltageLowAlarmNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.6.2.2.2.0.7

This trap message is reported when the input voltage is too low.

acInputVoltageLowAlarmResumeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.6.2.2.2.0.8

This trap message is reported when the input voltage resumes to the normal range from a low value.

dcOutputVoltageHighAlarmNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.6.2.2.2.0.9

This trap message is reported when the output voltage is too high.

dcOutputVoltageHighAlarmResumeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.6.2.2.2.0.10

This trap message is reported when the output voltage resumes to the normal range from a high value.

dcOutputCurrentHighAlarmNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.6.2.2.2.0.11

This trap message is reported when the output current is too high.

More MIBs from Huawei

Browse all HuaweiMIBs →
H3C-ENTITY-VENDORTYPE-OID-MIB

SNMP MIB module

1462 objects→
HUAWEI-WLAN-CONFIGURATION-MIB

The HUAWEI-WLAN-CONFIGURATION-MIB facilitates the configuration and monitoring of Huawei Wireless LAN access point parameters, specifically managing AP port link profiles and broadcast suppression settings. This module enables administrators to enforce traffic control policies and optimize wireless network performance by adjusting switch profile associations and limiting broadcast traffic on specific ports.

1280 objects→
HUAWEI-XQoS-MIB

The HUAWEI-XQoS-MIB enables configuration and real-time monitoring of Class Based QoS parameters on Huawei network devices, specifically tracking traffic classification rules, queue states, and policy enforcement metrics. This module facilitates granular control over bandwidth allocation and packet prioritization by exposing objects for policy definitions, interface queue depths, and dropped packet counters associated with QoS classes.

1134 objects→
HUAWEI-ENT-VOICE-PBX-MIB

The HUAWEI-ENT-VOICE-PBX-MIB enables SNMP-based monitoring and configuration of Huawei enterprise PBX systems, specifically tracking voice trunk states, active call session counts, and hardware resource utilization for telephony management.

1011 objects→
HUAWEI-WLAN-DEVICE-MIB

The HUAWEI-WLAN-DEVICE-MIB enables SNMP-based monitoring and configuration of Huawei Access Point hardware, providing granular visibility into device status, radio interface statistics, client association counts, and operational health metrics.

897 objects→
HUAWEI-BRAS-SBC-MIB

The HUAWEI-BRAS-SBC-MIB module provides configuration and status monitoring for Huawei Broadband Remote Access Server (BRAS) Session Border Controllers, specifically tracking session establishment parameters, resource utilization, and protocol state variables. It enables administrators to manage SBC-specific attributes such as call routing policies, media stream limits, and session timeout thresholds within the broadband aggregation network.

848 objects→