Home/Catalog/HUAWEI-ENVIRONMENT-MIB

HUAWEI-ENVIRONMENT-MIB

AI MIB Summary

The HUAWEI-ENVIRONMENT-MIB enables SNMP-based monitoring of Huawei network device chassis health by exposing real-time metrics for temperature, voltage, current, fan speed, and digital input status. This module facilitates proactive fault detection and environmental threshold management for critical hardware components within the device's environment monitoring unit.

The MIB module defines MIB objects which include Environment Monitor Unit, Analog Environment data, Digital Environment data, Out data and Fan data Monitor management MIB interfaces.
Main OID:
hwEnvironment.1.3.6.1.4.1.2011.6.1
167
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

167 total
Object Name
hwEnvironmentThe MIB module defines MIB objects which include Environment Monitor Unit, Analog Environment data, Digital Environment data, Out data and Fan data Monitor management MIB interfaces.
MODULE-IDENTITY
.1.3.6.1.4.1.2011.6.1
hwEnvironmentMon
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.1
hwEnvironmentInfoTableInformation table of Environment Monitor Unit. The Environment Monitor Unit is some kind of Environment monitoring device and is used to monitor many kinds of Environment data. The maximum number of Environment Monitor Units in one device node is 64. The index of this table is hwEnvEmuIndex. hwEnvEmuIndex is the index of one Environment Monitor Unit.
SEQUENCE OF HwEnvironmentInfoEntry
.1.3.6.1.4.1.2011.6.1.1.1
hwEnvironmentInfoEntryInformation table of Environment Monitor Unit. The Environment Monitor Unit is some kind of Environment monitoring device and is used to monitor many kinds of Environment data. The maximum number of Environment Monitor Units in one device node is 64. The index of this entry is hwEnvEmuIndex. hwEnvEmuIndex is the index of one Environment Monitor Unit.
HwEnvironmentInfoEntry
.1.3.6.1.4.1.2011.6.1.1.1.1
hwEnvEmuIndexhwEnvEmuIndex is the index of the Environment monitoring unit, used as the index of hwEnvironmentInfoTable. Range: 0 - 2048ro
Integer32
.1.3.6.1.4.1.2011.6.1.1.1.1.1
hwEnvEmuTypeType of the physical monitoring devices associated with the environment monitoring unit. Options: 1.h302ESC(1) -Type of the physical monitoring devices is H302ESC 2.h303ESC(2) -Type of the physical monitoring devices is H303ESC 3.h4875(3) -Type of the physical monitoring devices is 4875 power monitoring frame 4.h301ESC(4) -Type of the physical monitoring devices is H301ESC 5.switch(5) -Distribute monitoring frame 6.fanEscFrame(6) -ESC monitoring fan frame 7.fanFrame(7) -monitoring fan frame 8.h4845(8) -4845 power monitoring 9.fanFCBFrame(9) -FCB monitoring fan frame 10.fanFDMUFrame(10) -FDMU monitoring fan frame 11.h304ESC(11) -provides the management function of battery 12.pwma(12) -Type of the physical monitoring devices is pwma 13.h561esc(13) -H561ESC 14.h801esc(14) -H801Esc 15.h612pwbp(15) -H612pwbp 16.pse158(16) -pse158 17.h4805(19) -h4805 18.pdu(20) -pdu 19.acrmu(21) -ac_rmu 20.acfan(22) -ac_fan 21.dcfan(23) -dc_fan 22.rmun1509(24) -rmun1509 23.onps150(25) -onps150 24.h801pmix(26) -h801pmix 25.h4875L(27) -h4875L 26.miniESC(28) -miniESC 27.h831VESC(29) -H831VESC 28.h601VESC(30) -H601VESC 29.h4830L(31) -h4830L 30.h801citx(32) -h801citx 31.h801citd(33) -h801citd 32.h831ccuh(34) -h831ccuh 33.h831pmu(35) -h831pmu 34.pwr3000(36) -a type of power named power 3000, supports 12 rectifier modules 35.tcu(37) -tcu 36.liFeBattery(38) -liFeBattery 37.transemu(39) -a type of emu for transport environment information to managment center 38.smu(40) -site monitoring unit 39.vpea(41) -vector monitoring unit 40.other(255) -otherrw
Enumeration
.1.3.6.1.4.1.2011.6.1.1.1.1.2
hwEnvBoardNameName of the environment monitoring unit.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.1.1.3
hwEnvCommStateStatus of the communication between the environment monitoring unit and the device. The environmental condition can be tested only when the communication is normal. Options: 1.normal(1) - indicates that communication state is normal 2.shutdown(2) - indicates that communication state is shutdown 3.fault(3) - indicates that communication state is fault 4.abnormal(4) - indicates that communication state is abnormal 5.config(5) - indicates that communication state is configro
Enumeration
.1.3.6.1.4.1.2011.6.1.1.1.1.4
hwEnvRowStatusRowStatus standard operation. The creation and deletion operations are supported currently.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.1.1.5
hwEnvVersionVersion information of the environment monitoring unit.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.1.1.6
hwEnvFrameIdID of the shelf housing the environment monitoring unit.rw
Integer32
.1.3.6.1.4.1.2011.6.1.1.1.1.7
hwEnvAdminStatusThe management status of the monitoring unit. Options: 1.noOperation(1) -no any operation 2.reset(2) -reset the monitoring board 3.manage(3) -manage the monitoring unit 4.unmanage(4) -undo manage the monitoring unit 5.clearsmokealarm(5) -clear the smoke alarm for miniEscrw
Enumeration
.1.3.6.1.4.1.2011.6.1.1.1.1.8
hwEnvSlaveNodeIdID of the slave object that the environment monitoring unit belongs to. The environment monitoring unit uses the slave object ID to communicate with the upstream equipment.rw
Integer32
.1.3.6.1.4.1.2011.6.1.1.1.1.9
hwEnvComTypeThe serial communication protocol type between the monitoring unit and the upstream equipment. The protocol types used are as follows: Options: 1.unknown(1) -The protocol types is unknown 2.serialRS485(2) -The protocol types is serialRS485 3.serialRS232(3) -The protocol types is serialRS232 4.serialRS422(4) -The protocol types is serialRS422rw
Enumeration
.1.3.6.1.4.1.2011.6.1.1.1.1.10
hwEnvCLEICodeEnvironment CLEI Code.ro
OCTET STRING
.1.3.6.1.4.1.2011.6.1.1.1.1.11
hwEnvEmuPowerPower of the environment monitoring equipment associated with the environment monitoring unit. Unit: Watt.ro
Integer32
.1.3.6.1.4.1.2011.6.1.1.1.1.12
hwEnvEmuTypeNameName of the environment type.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.1.1.13
hwAnaChannelTableInformation table of the analog parameters monitored. The indexes of this table are hwEnvEmuIndex or hwAnaChannelIndex. hwEnvEmuIndex is the index of the environment monitoring unit, and hwAnaChannelIndex is the index of the analog parameter that is monitored by a monitoring unit.
SEQUENCE OF HwAnaChannelEntry
.1.3.6.1.4.1.2011.6.1.1.2
hwAnaChannelEntryInformation table of the analog parameters monitored. The indexes of this entry are hwEnvEmuIndex or hwAnaChannelIndex. hwEnvEmuIndex is the index of the environment monitoring unit, and hwAnaChannelIndex is the index of the analog parameter that is monitored by a monitoring unit.
HwAnaChannelEntry
.1.3.6.1.4.1.2011.6.1.1.2.1
hwAnaChannelIndexIndex of the analog parameter that is monitored by the monitoring unit. Range: 0 - 255ro
Integer32
.1.3.6.1.4.1.2011.6.1.1.2.1.1
hwAnaNameName of the analog parameter that is monitored by a monitoring unit.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.2.1.2
hwAnaTypeThis object indicates the type of the sensor that is used to test the Analog parameter. Options: 1.invalid(-1) -there is no valid sensor 2.voltage(1) -voltage sensor currently 3.current(2) -current sensor currentlyrw
Enumeration
.1.3.6.1.4.1.2011.6.1.1.2.1.3
hwAnaMeasureTypeThis object indicates the unit of the analog parameter that is tested.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.2.1.4
hwAnaWorkHighHigh limit of the analog normal workrw
Integer32
.1.3.6.1.4.1.2011.6.1.1.2.1.5
hwAnaWorkLowLow limit of the analog normal workrw
Integer32
.1.3.6.1.4.1.2011.6.1.1.2.1.6
hwAnaAlmHighHigh limit of the analog alarm. The alarm is produced when the measurement value is higher than this valuerw
Integer32
.1.3.6.1.4.1.2011.6.1.1.2.1.7
hwAnaAlmLowThe low limit of the analog alarm. The alarm is produced when the measurement value is lower than this value.rw
Integer32
.1.3.6.1.4.1.2011.6.1.1.2.1.8
hwAnaCurrentValueThe actual measurement value of the present analog. Unit: milliro
Integer32 UNITS "milli"
.1.3.6.1.4.1.2011.6.1.1.2.1.9
hwAnaAlarmStateThe status of the present monitored. Options: 1.normal(1) -indicates that the measurement value is lower than the set high limit of the alarm, and higher than the low limit 2.overWorkHigh(2) -indicates that the measurement value is higher than the high limit of the alarm 3.belowWorkLow(3) -indicates that the measurement value is lower than the low limit of the alarm 4.abnormal(4) -indicates that the measurement value is outside the scope of limit of the alarm 5.invalid(-1) -indicates that the device can not get the value, e.g. the EMU does not support this operation, or the EMU state is abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.1.1.2.1.10
hwAnaRowStatusRowStatus standard operation. The values 1 and 2 are supported currently. 1 indicates the activation status, and 2 indicates the non-activation status.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.2.1.11
hwAnaAlarmIDAnalog alarm definition. Options: 1.temperature(1) -temperature alarm 2.humidity(2) -humidity alarm 3.voltage(3) -voltage alarm 4.current(4) -current alarm 5.userDefinedAlarm0(100) -analog user-defined alarm 0 6.userDefinedAlarm1(101) -analog user-defined alarm 1 7.userDefinedAlarm2(102) -analog user-defined alarm 2 8.userDefinedAlarm3(103) -analog user-defined alarm 3 9.userDefinedAlarm4(104) -analog user-defined alarm 4 10.userDefinedAlarm5(105) -analog user-defined alarm 5 11.userDefinedAlarm6(106) -analog user-defined alarm 6 12.userDefinedAlarm7(107) -analog user-defined alarm 7 13.userDefinedAlarm8(108) -analog user-defined alarm 8 14.userDefinedAlarm9(109) -analog user-defined alarm 9 15.userDefinedAlarm10(110) -analog user-defined alarm 10 16.userDefinedAlarm11(111) -analog user-defined alarm 11 17.userDefinedAlarm12(112) -analog user-defined alarm 12 18.userDefinedAlarm13(113) -analog user-defined alarm 13 19.userDefinedAlarm14(114) -analog user-defined alarm 14 20.userDefinedAlarm15(115) -analog user-defined alarm 15 21.default(65535) -default analog alarmrw
Enumeration
.1.3.6.1.4.1.2011.6.1.1.2.1.12
hwDigChannelTableInformation table of the digital parameters monitored. The indexes of this table are hwEnvEmuIndex and hwDigChannelIndex. hwEnvEmuIndex is the index of the environment monitoring unit, and hwDigChannelIndex is the index of the digital parameter that is monitored by a monitoring unit.
SEQUENCE OF HwDigChannelEntry
.1.3.6.1.4.1.2011.6.1.1.3
hwDigChannelEntryInformation table of the digital parameters monitored. The indexes of this entry are hwEnvEmuIndex and hwDigChannelIndex. hwEnvEmuIndex is the index of the environment monitoring unit, and hwDigChannelIndex is the index of the digital parameter that is monitored by a monitoring unit.
HwDigChannelEntry
.1.3.6.1.4.1.2011.6.1.1.3.1
hwDigChannelIndexIndex of the digital parameter that is monitored by a monitoring unit. Range: 0 - 255ro
Integer32
.1.3.6.1.4.1.2011.6.1.1.3.1.1
hwDigChannelNameName of the digital parameter that is monitored by a monitoring unit.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.3.1.2
hwAlmConditionAlarm conditions. Options: 1.lowLevelAlarm(1) -refers to the alarm produced when the digital sensor detects the low level 2.highLevelAlarm(2) -refers to the alarm produced when the digital sensor detects the high level 3.invalid(-1) -indicates that the device can not get the value, e.g. the EMU does not support this operation, or the EMU state is abnormalrw
Enumeration
.1.3.6.1.4.1.2011.6.1.1.3.1.3
hwDigChannelStateThe status of the present monitored digital sensor Options: 1.normal(1) -indicates that the digital sensor works normally 2.alarm(2) -indicates that the digital sensor produces the alarm signal 3.invalid(-1) -indicates that the device can not get the value, e.g. the EMU does not support this operation, or the EMU state is abnormalro
Enumeration
.1.3.6.1.4.1.2011.6.1.1.3.1.4
hwDigRowStatusRowStatus standard operation. The values 1 and 2 are supported currently. 1 indicates the activation status, and 2 indicates the non-activation status.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.3.1.5
hwDigAlarmIDDigital alarm definition. Options: 1.acvoltage(1) -ac voltage alarm 2.acswitch(2) -ac switch alarm 3.batteryvoltage(3) -battery voltage alarm 4.batteryfuse(4) -battery fuse alarm 5.loadfuse(5) -load fuse alarm 6.rectifier(6) -rectifier alarm 7.dcpower(7) -dc power alarm 8.cupboarddoor(8) -cupboard alarm 9.roomdoor(9) -room door alarm 10.window(10) -window alarm 11.thief(11) -thief alarm 12.wiring(12) -wiring alarm 13.fan(13) -fan alarm 14.fire(14) -fire alarm 15.fog(15) -fog alarm 16.water(16) -water alarm 17.diesel(17) -diesel alarm 18.smell(18) -smell alarm 19.aircondition(19) -air-condition alarm 20.arrester(20) -arrester alarm 21.dcvoltage(21) -dc voltage 22.outputswitch(22) -output swith 23.userDefinedAlarm0(100) -digital user-defined alarm 0 24.userDefinedAlarm1(101) -digital user-defined alarm 1 25.userDefinedAlarm2(102) -digital user-defined alarm 2 26.userDefinedAlarm3(103) -digital user-defined alarm 3 27.userDefinedAlarm4(104) -digital user-defined alarm 4 28.userDefinedAlarm5(105) -digital user-defined alarm 5 29.userDefinedAlarm6(106) -digital user-defined alarm 6 30.userDefinedAlarm7(107) -digital user-defined alarm 7 31.userDefinedAlarm8(108) -digital user-defined alarm 8 32.userDefinedAlarm9(109) -digital user-defined alarm 9 33.userDefinedAlarm10(110) -digital user-defined alarm 10 34.userDefinedAlarm11(111) -digital user-defined alarm 11 35.userDefinedAlarm12(112) -digital user-defined alarm 12 36.userDefinedAlarm13(113) -digital user-defined alarm 13 37.userDefinedAlarm14(114) -digital user-defined alarm 14 38.userDefinedAlarm15(115) -digital user-defined alarm 15 39.userDefinedAlarm16(116) -digital user-defined alarm 16 40.userDefinedAlarm17(117) -digital user-defined alarm 17 41.userDefinedAlarm18(118) -digital user-defined alarm 18 42.userDefinedAlarm19(119) -digital user-defined alarm 19 43.userDefinedAlarm20(120) -digital user-defined alarm 20 44.userDefinedAlarm21(121) -digital user-defined alarm 21 45.userDefinedAlarm22(122) -digital user-defined alarm 22 46.userDefinedAlarm23(123) -digital user-defined alarm 23 47.userDefinedAlarm24(124) -digital user-defined alarm 24 48.userDefinedAlarm25(125) -digital user-defined alarm 25 49.userDefinedAlarm26(126) -digital user-defined alarm 26 50.userDefinedAlarm27(127) -digital user-defined alarm 27 51.userDefinedAlarm28(128) -digital user-defined alarm 28 52.userDefinedAlarm29(129) -digital user-defined alarm 29 53.userDefinedAlarm30(130) -digital user-defined alarm 30 54.userDefinedAlarm31(131) -digital user-defined alarm 31 55.default(65535) -digital alarmrw
Enumeration
.1.3.6.1.4.1.2011.6.1.1.3.1.6
hwControlOutTableMonitored digital out table. This table indicates information about whether digital parameter is monitored. The indexes of this table are hwEnvEmuIndex and hwControlOutIndex. hwEnvEmuIndex is the index of the monitoring unit, and hwControlOutIndex is the index of the digital out table monitored in the monitoring unit.
SEQUENCE OF HwControlOutEntry
.1.3.6.1.4.1.2011.6.1.1.4
hwControlOutEntryMonitored digital out table. This table indicates information about whether digital parameter is monitored. The indexes of this entry are hwEnvEmuIndex and hwControlOutIndex. hwEnvEmuIndex is the index of the monitoring unit, and hwControlOutIndex is the index of the digital out table monitored in the monitoring unit.
HwControlOutEntry
.1.3.6.1.4.1.2011.6.1.1.4.1
hwControlOutIndexIndex of the digital out table monitored in the monitoring unit Range: 0 - 255ro
Integer32
.1.3.6.1.4.1.2011.6.1.1.4.1.1
hwControlOutNameName of the monitored digital out tablerw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.4.1.2
hwControlOutAdminStatusControl Out administration: executes the on/off operation. Options: 1. on(1) - trun on 2. off(2) - trun offrw
Enumeration
.1.3.6.1.4.1.2011.6.1.1.4.1.3
hwControlOutRowStatusRowStatus standard operation. The values 1 and 2 are supported currently. 1 indicates the activation status, and 2 indicates the non-activation status.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.4.1.4
hwFanTableInformation table of fan monitoring. The index of this table is hwEnvEmuIndex that comes from hwEnvironmentInfoTable. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is fan.
SEQUENCE OF HwFanEntry
.1.3.6.1.4.1.2011.6.1.1.5
hwFanEntryInformation table of fan monitoring. The index of this entry is hwEnvEmuIndex that comes from hwEnvironmentInfoTable. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is fan.
HwFanEntry
.1.3.6.1.4.1.2011.6.1.1.5.1
hwFanNameFan namerw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.5.1.1
hwFanControlModeThe fan control modes of the fan frame. Options: 1.manual(1) -indicates that the fan is always on, and the fan speed can be manually adjusted 2.emuAuto(2) -indicates that the fan is in the automatic mode, and can be automatically controlled depending on the temperature of the fan 3.fixed(3) -indicates that the fan is in the fixed mode, and adjusting its speed is not allowed 4.mainboardAuto(4) -indicates that the fan is in the automatic mode, and can be automatically controlled depending on the temperature of the boards in the framerw
Enumeration
.1.3.6.1.4.1.2011.6.1.1.5.1.2
hwFanControlStateFor ESC fan, all should be checked to turn on the fan, while all should not be checked to turn off the fan. Options: 1.fan1(0) -indicates that the first fan needs to be opened 2.fan2(1) -indicates that the second fan needs to be opened 3.fan3(2) -indicates that the third fan needs to be opened 4.fan4(3) -indicates that the fourth fan needs to be opened 5.fan5(4) -indicates that the fifth fan needs to be opened 6.fan6(5) -indicates that the sixth fan needs to be openedrw
Bits
.1.3.6.1.4.1.2011.6.1.1.5.1.3
hwESCFanTempAutoOnThe fan temperature set, in unit of centigrade. The MIB object only functions for the fan monitoring board of ESC and is not applicable to the type of fan monitoring board. Only when the fan control mode of the fan frame is hwFanControl =auto (3), the temperature control mode will take effect. When detecting the environment temperature higher than the set value, the fan will be on (or increase its rotation).rw
Integer32
.1.3.6.1.4.1.2011.6.1.1.5.1.4
hwESCFanTempAutoOffThe fan temperature set, in unit of centigrade. The MIB object only functions for the fan monitoring board of ESC and is not applicable to the type of fan monitoring board. Only when the fan control mode of the fan frame is hwFanControl =auto (3), the temperature control mode will take effect. When detecting the environment temperature is lower than the set value, the fan will be turned off (decrease its rotation).rw
Integer32
.1.3.6.1.4.1.2011.6.1.1.5.1.5
hwFanRowStatusRowStatus standard operation.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.5.1.6
hwCurrentTempThe present temperature value, in unit of cent-centigradero
Integer32
.1.3.6.1.4.1.2011.6.1.1.5.1.7
hwFanSpeedModeThe adjusting rotation mode of the fan. Options: 1.continue(1) -continuous control 2.discontinue(2) -discrete control 3.percent(3) -duty ratio control 4.invalid(-1) -indicates that the device can not get the value, e.g. the EMU does not support this operation, or the EMU state is abnormalrw
Enumeration
.1.3.6.1.4.1.2011.6.1.1.5.1.8
hwFanSpeedWhen hwFanSpeedMode is the continue mode, 0 indicates the present wind speed +1, while 1 indicates the present wind speed -1. When hwFanSpeedMode is discontinuous, 0 indicates fixed high speed, while 1 indicates fixed low speed. When hwFanSpeedMode is percent, the value delivered by the main control is the percent value, ranging from 35 to 100, used to initialize the rotation of fan for various device main controls. invalid(-1) indicates that the fan tray does not work normally. For example, the fan tray is disconnected from the control board, or some of the fans in the fan tray are blocked.rw
Integer32
.1.3.6.1.4.1.2011.6.1.1.5.1.9
hwFanTypeDescriptionFan Type Description. The values 1 and 2 are supported currently. 1 indicates the activation status, and 2 indicates the non-activation status.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.5.1.10
hwTcuTableInformation table of temperature control unit. The index of this table is hwEnvEmuIndex that comes from hwEnvironmentInfoTable. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is temperature control unit.
SEQUENCE OF HwTcuEntry
.1.3.6.1.4.1.2011.6.1.1.6
hwTcuEntryInformation table of temperature control unit. The index of this entry is hwEnvEmuIndex that comes from hwEnvironmentInfoTable. hwEnvEmuIndex is the index of the monitoring unit whose monitoring type is temperature control unit.
HwTcuEntry
.1.3.6.1.4.1.2011.6.1.1.6.1
hwTcuHeatExchangerTypeHeat Exchanger Type Description.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.6.1.1.6.1.1
hwTcuExternalFanRevThe rev of Heat Exchanger outer fan, in unit of RMP (rotate per minite)ro
Integer32
.1.3.6.1.4.1.2011.6.1.1.6.1.2
hwTcuInternalFanRevThe rev of Heat Exchanger inner fan, in unit of RMP (rotate per minite)ro
Integer32
.1.3.6.1.4.1.2011.6.1.1.6.1.3
hwTcuStartHeatTempThe temperature of Heat Exchanger starts to heat up, in unit of Celsiusrw
Integer32
.1.3.6.1.4.1.2011.6.1.1.6.1.4
hwTcuStopHeatTempThe temperature of Heat Exchanger stops heating, in unit of Celsiusrw
Integer32
.1.3.6.1.4.1.2011.6.1.1.6.1.5
snmpTrapsDef
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.2
emmsnmpTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.2.0
envCommAlarmThe communication alarm of environment monitoring board, reporting the environment monitoring unit ID. This trap message is reported when the communication between the emu and control board is fault.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.1
envCommAlarmResumeThe communication alarm recovery of the environment monitoring, reporting the environment monitoring unit ID. This trap message is reported when the communication between the emu and control board resumes.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.2
anaFaultAlarmThe alarm recovery of the analog exception, reporting the environment monitoring unit ID. This trap message is reported when there is an analog exception in emu.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.3
anaFaultAlarmResumeThe alarm recovery of the analog exception, reporting the environment monitoring unit ID. This trap message is reported when the analog exception recovery in emu.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.4
anaTooHighAlarmThe alarm of too high an analog, reporting the environment monitoring unit ID and the channel ID of the analog sensor. This trap message is reported when an analog value is too high.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.5
anaTooHighAlarmResumeThe alarm of too high analog resume, reporting the environment monitoring unit ID. This trap message is reported when an analog value returns to normal range from the high value.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.6
anaTooLowAlarmThe alarm of too low an analog, reporting the environment monitoring unit ID and the channel ID of the analog sensor. This trap message is reported when an analog value is too low.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.7
anaTooLowAlarmResumeThe alarm of too low an analog, reporting the environment monitoring unit ID. This trap message is reported when an analog value returns to normal range from the low value.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.8
controlAlarmThe control alarm, reporting the environment monitoring unit ID. This trap message is reported when emu control operation fails.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.9
controlAlarmResumeThe control alarm, reporting the environment monitoring unit ID. This trap message is reported when emu control operation resumes.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.10
digtalMeasureAlarmThe digital measure alarm, reporting the environment monitoring unit ID and the channel ID of the digital sensor. This trap message is reported when emu measure operation fails.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.11
digtaleasureAlarmResumeThe digital measure alarm recovery, reporting the environment monitoring unit ID and the channel ID of the digital sensor. This trap message is reported when emu measure operation resumes.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.12
fanExistsAlarmFan nonexistance alarm. This trap message is reported when there is no fan device connected to control board.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.13
fanExistsAlarmResumeFan nonexistance alarm recovery. This trap message is reported when there is a fan device connected to control board.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.14
fanRunStateAlarmFan running status alarm. This trap message is reported when the fan run state gets abnormal.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.2.0.15
envConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.3
envCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.3.1
envGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.3.2
hwEnvironTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.4
hwEnvironCommonTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.4.1
hwEnvironCommonTrapsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.4.1.0
hwEmmEmuAutofindTrapThe agent generates this trap when a new EMU autofind.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.1.0.1
hwEnvironAlarmTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.4.2
hwEnvironEmuAlarmTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.4.2.1
hwEnvironEmuAlarmTrapsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.4.2.1.0
hwEmmEmufailTrapThe agent generates this trap when the communication of the EMU with the host is abnormal.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.1.0.1
hwEmmEmuRecoverTrapThe agent generates this trap when the communication of the EMU with the host recovers.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.1.0.2
hwEmmEmuHardwareFaultTrapThe agent generates this trap when the a Hardware exception occurs.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.1.0.3
hwEmmEmuHardwareRecoverTrapThe agent generates this trap when the a Hardware exception Recover
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.1.0.4
hwEmmEmuAutofindFailTrapThe agent generates this trap when the emu autofind fail.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.1.0.5
hwEmmEmuFanStateTrapThe agent generates this trap when the fan is not configured or fails.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.1.0.6
hwEnvironAnaAlarmTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.4.2.2
hwEnvironAnaAlarmTrapsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.4.2.2.0
hwEmmAnaUnnamedFaultTrapThe agent generates this trap when an unnamed analog alarm occurs.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.2.0.1
hwEmmAnaUnnamedRecoverTrapThe agent generates this trap when an unnamed analog alarm recovers.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.2.0.2
hwEmmAnaTempFaultTrapThe agent generates this trap when the analog temperature alarm occurs.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.2.0.3
hwEmmAnaTempRecoverTrapThe agent generates this trap when the analog temperature alarm recovers.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.2.0.4
hwEmmAnaHumyFaultTrapThe agent generates this trap when the analog humidity alarm occurs.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.2.0.5
hwEmmAnaHumyRecoverTrapThe agent generates this trap when the analog humidity alarm recovers.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.2.0.6
hwEmmAnaVoltFaultTrapThe agent generates this trap when the analog voltage alarm occurs.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.2.0.7
hwEmmAnaVoltRecoverTrapThe agent generates this trap when the analog voltage alarm recovers.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.2.0.8
hwEmmAnaCurrentFaultTrapThe agent generates this trap when the analog current alarm occurs.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.2.0.9
hwEmmAnaCurrentRecoverTrapThe agent generates this trap when the analog current alarm recovers.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.2.0.10
hwEnvironDigAlarmTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.4.2.3
hwEnvironDigAlarmTrapsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.4.2.3.0
hwEmmDigFanBlockFaultTrapThe agent generates this trap when the fan is blocked.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.1
hwEmmDigFanBlockRecoverTrapThe agent generates this trap when the fan is recovered from block.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.2
hwEmmDigFanTempHighFaultTrapThe agent generates this trap when the temperature of fan is too high.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.3
hwEmmDigFanTempHighRecoverTrapThe agent generates this trap when the temperature of fan recover from too high.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.4
hwEmmDigUnnamedFaultTrapThe agent generates this trap when a unnamed digital fault occurs.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.5
hwEmmDigUnnamedRecoverTrapThe agent generates this trap when a unnamed digital recovers.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.6
hwEmmDigOutputswitchFaultTrapThe agent generates this trap when Output switch digital fault occurs.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.7
hwEmmDigOutputswitchRecoverTrapThe agent generates this trap when Output switch digital recovers.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.8
hwEmmDigAcvolFaultTrapThe agent generates this trap when The AC voltage is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.11
hwEmmDigAcvolRecoverTrapThe agent generates this trap when The AC voltage recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.12
hwEmmDigAcswitchFaultTrapThe agent generates this trap when The AC switch is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.13
hwEmmDigAcswitchRecoverTrapThe agent generates this trap when The AC switch recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.14
hwEmmDigBattvolFaultTrapThe agent generates this trap when The batt vol is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.15
hwEmmDigBattvolRecoverTrapThe agent generates this trap when The batt vol recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.16
hwEmmDigBattfuseFaultTrapThe agent generates this trap when The battery fuse is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.17
hwEmmDigBattfuseRecoverTrapThe agent generates this trap when The battery fuse recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.18
hwEmmDigLoadfuseFaultTrapThe agent generates this trap when The load fuse is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.19
hwEmmDigLoadfuseRecoverTrapThe agent generates this trap when The load fuse recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.20
hwEmmDigRectifierFaultTrapThe agent generates this trap when The Rectifier is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.21
hwEmmDigRectifierRecoverTrapThe agent generates this trap when The Rectifier recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.22
hwEmmDigDcpowerFaultTrapThe agent generates this trap when The dc-power is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.23
hwEmmDigDcpowerRecoverTrapThe agent generates this trap when The dc-power recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.24
hwEmmDigRoomdoorFaultTrapThe agent generates this trap when The Roomdoor is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.25
hwEmmDigRoomdoorRecoverTrapThe agent generates this trap when The Roomdoor recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.26
hwEmmDigTheftFaultTrapThe agent generates this trap when The Roomdoor is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.27
hwEmmDigTheftRecoverTrapThe agent generates this trap when The Roomdoor recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.28
hwEmmDigWiringFaultTrapThe agent generates this trap when The WIRING is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.29
hwEmmDigWiringRecoverTrapThe agent generates this trap when The WIRING recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.30
hwEmmDigFanFaultTrapThe agent generates this trap when The FAN is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.31
hwEmmDigFanRecoverTrapThe agent generates this trap when The FAN recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.32
hwEmmDigFireFaultTrapThe agent generates this trap when The Fire is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.33
hwEmmDigFireRecoverTrapThe agent generates this trap when The Fire recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.34
hwEmmDigFogFaultTrapThe agent generates this trap when The Fog is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.35
hwEmmDigFogRecoverTrapThe agent generates this trap when The Fog recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.36
hwEmmDigWaterFaultTrapThe agent generates this trap when The Water is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.37
hwEmmDigWaterRecoverTrapThe agent generates this trap when The Water recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.38
hwEmmDigDieselFaultTrapThe agent generates this trap when The Diesel is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.39
hwEmmDigDieselRecoverTrapThe agent generates this trap when The Diesel recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.40
hwEmmDigSmellFaultTrapThe agent generates this trap when The Smell is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.41
hwEmmDigSmellRecoverTrapThe agent generates this trap when The Smell recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.42
hwEmmDigAirconditionFaultTrapThe agent generates this trap when The Air condition is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.43
hwEmmDigAirconditionRecoverTrapThe agent generates this trap when The Air condition recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.44
hwEmmDigArrsterFaultTrapThe agent generates this trap when The arrester is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.45
hwEmmDigArrsterRecoverTrapThe agent generates this trap when The arrester recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.46
hwEmmDigDcvolFaultTrapThe agent generates this trap when The DC VOL is out of the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.47
hwEmmDigDcvolRecoverTrapThe agent generates this trap when The DC VOL recovers to the normal range.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.48
hwEmmFanCriticalBlockFaultTrapThe agent generates this trap when more than two fans are blocked.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.49
hwEmmFanCriticalBlockRecoverTrapThe agent generates this trap when the critical multi-fan blocking recovers.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.50
hwEmmDigitalSwitchOpenTrapThe agent generates this trap when the 48V input switch is closed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.51
hwEmmDigitalSwitchCloseTrapThe agent generates this trap when the 48V input switch is opened.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.6.1.4.2.3.0.52
hwEmmTrapVbOids
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.6.1.5
hwFanStatusThe status of the fan. Options: 1.notconfig(1) -The status of the fan is notconfig 2.failure(2) -The status of the fan is failro
Enumeration
.1.3.6.1.4.1.2011.6.1.5.1
hwFailureCauseThe reason of the auto-finding failure: Options: 1.fullemu(1) -No enough EMU IDs are available 2.shelfnotsupport(2) -The EMU does not support the auto discovery function 3.emunotsupportautofind(3) -The shelf does not support the EMU of this typero
Enumeration
.1.3.6.1.4.1.2011.6.1.5.2
hwEnvAutofindNodeIdThe NodeId of the auto-found EMU.ro
Integer32
.1.3.6.1.4.1.2011.6.1.5.3
hwEnvAutofindEmuTypeThe type of the auto-found EMU.ro
OCTET STRING
.1.3.6.1.4.1.2011.6.1.5.4
hwEnvAutofindBoardNameThe board name of the auto-found EMU.ro
OCTET STRING
.1.3.6.1.4.1.2011.6.1.5.5
HUAWEI-ENVIRONMENT-MIB - SNMP MIB Reference | MIBs Explorer