H3C-STORAGE-MIB
AI MIB Summary
The H3C-STORAGE-MIB module enables SNMP-based monitoring and configuration of H3C storage subsystems, specifically tracking device properties, storage pool status, and management parameters. It facilitates the retrieval of operational metrics regarding storage array health, capacity allocation, and interface states for centralized network management systems.
This MIB describes the general information of storage device, such as the property, configuration and management.
Main OID:
h3cStorageMIB.1.3.6.1.4.1.2011.10.10.1
91
Objects
Active
Status
8
Dependencies
Imported Objects
Objects
91 total| Object Name |
|---|
h3cStorageMIBThis MIB describes the general information of storage device, such as the property, configuration and management. MODULE-IDENTITY .1.3.6.1.4.1.2011.10.10.1 |
h3cStorageMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.10.1.1 |
h3cStorageServerInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.10.1.1.1 |
h3cStorageServerCapability OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.10.1.1.1.1 |
h3cRaidCapabilityThis object identifies if the agent support raid management.ro H3cStorageCapableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.1.1 |
h3cFcCapabilityThis object identifies if the agent support FC(fiber channel) management.ro H3cStorageCapableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.1.2 |
h3cNasCapabilityThis object identifies if the agent support NAS(Network Attached Storage).ro H3cStorageCapableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.1.3 |
h3cAdaptiveRepCapabilityThis object identifies if the agent support adaptive replication. With adaptive replication option, data from the primary resource is continuously replicated to a replication resource unless the system determines it is not practical or possible, such as when there is insufficient bandwidth. For continuous replication to occur, a continuous replication resource is used to stage the data being replicated from the primary resource. Similar to a cache, as soon as data comes into the continuous replication resource, it is written to the replication resource.ro H3cStorageCapableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.1.4 |
h3cRemoteRepCapabilityThis object identifies if the agent support remote replication.ro H3cStorageCapableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.1.5 |
h3cSafeCacheCapabilityThis object identifies if the agent support safe cache.ro H3cStorageCapableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.1.6 |
h3cSyncMirrorCapabilityThis object identifies if the agent support synchronized mirror.ro H3cStorageCapableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.1.7 |
h3cAsyncMirrorCapabilityThis object identifies if the agent support asynchronous mirror.ro H3cStorageCapableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.1.8 |
h3cTimeMarkCapabilityThis object identifies if the agent support time mark.ro H3cStorageCapableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.1.9 |
h3cSseCapabilityThis object identifies if the agent support SSE(Storage Service Enable).ro H3cStorageCapableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.1.10 |
h3cStorageTargetConfig OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.10.1.1.1.2 |
h3ciSCSITargetEnableThis object identifies if the agent support iSCSI target.rw H3cStorageEnableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.2.1 |
h3cFcTargetEnableThis object identifies if the agent support FC target.rw H3cStorageEnableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.2.2 |
h3cStorageServerPhysInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.10.1.1.1.3 |
h3cServerLocationLedStateThis object identifies the state of storage device's location led.rw H3cStorageLedStateType (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.3.1 |
h3cServerResetButtonStateThis object identifies if the reset button is enable.rw H3cStorageEnableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.3.2 |
h3cServerPowerButtonStateThis object identifies if the power button is enable.rw H3cStorageEnableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.1.3.3 |
h3cServerPowerStateThis object identifies the state of power supply in the server, and is valid when UPS has been configured successful. The value 'online' means power supply is well-balanced. The value 'onlinebypass' means supply power without ups. The value 'onbattery' means supply power with battery. The value 'unknown' means the power supply state is unknown.ro Enumeration .1.3.6.1.4.1.2011.10.10.1.1.1.3.4 |
h3cStoragePhysicalInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.10.1.1.2 |
h3cDeuTableThis table contains some information of a particular DEU(Disk Enclosure Unit). SEQUENCE OF H3cDeuEntry .1.3.6.1.4.1.2011.10.10.1.1.2.1 |
h3cDeuEntryAn entry containing management information applicable to a particular DEU. H3cDeuEntry .1.3.6.1.4.1.2011.10.10.1.1.2.1.1 |
h3cDeuIndexThis object identifies the index of h3cDeuTable. The DEU identified by a particular value of this index is the same object as identified by the same value of entPhysicalIndex. Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.1.1.1 |
h3cDeuIDLedThis object identifies the state of storage DEU's led.rw H3cStorageLedStateType (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.2.1.1.2 |
h3cDeuDiskScanThe operation of scanning the table. When the value of this object is set to 'action', the operation of disk scanning is touched off.rw H3cStorageActionType (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.2.1.1.3 |
h3cStorageInterfaceTableThis table describes the interface information of the network. SEQUENCE OF H3cStorageInterfaceEntry .1.3.6.1.4.1.2011.10.10.1.1.2.2 |
h3cStorageInterfaceEntryAn entry containing management information applicable to a particular interface. H3cStorageInterfaceEntry .1.3.6.1.4.1.2011.10.10.1.1.2.2.1 |
h3cStorageInterfaceIndexThis object identifies the index of H3cStorageInterfaceEntry. The interface identified by this index is the same interface as identified by the same value of ifIndex. Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.2.1.1 |
h3cStorageInterfaceGatewayThis object identifies the gateway address of interface.rw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.2011.10.10.1.1.2.2.1.2 |
h3cStorageInterfaceGatewayTypeThis object identifies the gateway address type of interface.rw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.2011.10.10.1.1.2.2.1.3 |
h3cStorageInterfaceMTUThis object identifies the MTU of interface.rw Enumeration .1.3.6.1.4.1.2011.10.10.1.1.2.2.1.4 |
h3cBondingTableThis table describes the information of the Bonding interface. SEQUENCE OF H3cBondingEntry .1.3.6.1.4.1.2011.10.10.1.1.2.3 |
h3cBondingEntryAn entry containing management information applicable to a particular Bonding interface. H3cBondingEntry .1.3.6.1.4.1.2011.10.10.1.1.2.3.1 |
h3cBondingIndexThis object identifies the index of h3cBondingEntry. The interface identified by this index is the same interface as identified by the same value of ifIndex. Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.3.1.1 |
h3cBondingPortListAn entry contains management information applicable to a particular bonding interface. Every two bytes describe the ifIndex of an interface, and an interface belongs to one bonding group only. An interface should be deleted from the portlist of the bonding group it belongs to before it is added to another bonding group.rw OCTET STRING .1.3.6.1.4.1.2011.10.10.1.1.2.3.1.2 |
h3cScsiAdapterTableThis table containing some information of the SCSI(Small Computer System interface) adapter. SEQUENCE OF H3cScsiAdapterEntry .1.3.6.1.4.1.2011.10.10.1.1.2.4 |
h3cScsiAdapterEntryAn entry containing management information applicable to a particular SCSI adapter. H3cScsiAdapterEntry .1.3.6.1.4.1.2011.10.10.1.1.2.4.1 |
h3cAdapterNumberThis object identifies the index of the adapter . Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.1 |
h3cAdapterDescThis object describes some information of the adapter.ro OCTET STRING .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.2 |
h3cAdapterTypeThis object identifies the type of adapter. If the value of this object is not equal to 'fc', the associated object(such as h3cFcAdapterMode, h3cFcAdapterIWWPNs,h3cFcAdapterTWWPNs,h3cFcAdapterPortState,h3cFcAdapterModeSwitch) will be invalid.ro Enumeration .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.3 |
h3cFcAdapterModeThis object identifies the mode type of adapter.ro Enumeration .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.4 |
h3cFcAdapterInitiatorWwpnNameThis object describes the FC's adapter WWPN(World Wide Port Name) numbers.ro H3cWwpnListType (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.5 |
h3cFcAdapterTargetWwpnNameThis object describes the FC's target WWPN numbers.ro H3cWwpnListType (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.6 |
h3cFcAdapterPortStateThis object identifies the state of adapter's interface.ro Enumeration .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.7 |
h3cFcAdapterModeSwitchThis object identifies if the adapter work on a target mode.rw H3cStorageEnableState (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.8 |
h3cExtVoltageTableThis table contains some entity extend information of the voltage. SEQUENCE OF H3cExtVoltageEntry .1.3.6.1.4.1.2011.10.10.1.1.2.5 |
h3cExtVoltageEntryAn entry containing management information applicable to the voltage. H3cExtVoltageEntry .1.3.6.1.4.1.2011.10.10.1.1.2.5.1 |
h3cExtVoltagePhysicalIndexThis object identifies the entity index of voltage.ro PhysicalIndex (ENTITY-MIB) .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.1 |
h3cExtVoltagePhysicalNameThis object identifies the entity name of voltage.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.2 |
h3cExtVoltageThe voltage for the entity.ro Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.3 |
h3cExtVoltageLowThresholdThe low-threshold for the voltage. When voltage is lower than low-threshold, a notification will be sent.rw Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.4 |
h3cExtVoltageHighThresholdThe high-threshold for the voltage. When voltage is higher than high-threshold, a notification will be sent.rw Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.5 |
h3cExtCriticalVoltageLowThresholdThe critical low threshold for voltage. If the voltage is lower too much than the entity needs, the entity will halt.rw Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.6 |
h3cExtCriticalVoltageHighThresholdThe critical high threshold for voltage. If the voltage is higher too much than the entity needs, the entity will halt.rw Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.7 |
h3cExtShutdownVoltageLowThresholdThe voltage is lower than the critical low threshold. If the voltage is lower too much than the entity needs, the entity halts now.rw Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.8 |
h3cExtShutdownVoltageHighThresholdThe voltage is higher than the critical high threshold. If the voltage is higher too much than the entity needs, the entity halts now.rw Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.9 |
h3cStorageTraps OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.10.1.1.3 |
h3cStorageTrapsPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.10.1.1.3.0 |
h3cStorCriticalLowerTemperatureThresholdNotificationThe h3cStorCriticalLowerTemperatureThresholdNotification indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity needs, the entity will halt. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.1 |
h3cStorTemperatureTooLowThe h3cStorTemperatureTooLow indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity needs, the entity halts now. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.2 |
h3cExtVoltageLowThresholdNotificationThe h3cExtVoltageLowThresholdNotification indicates the Voltage is lower than the low-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.3 |
h3cExtVoltageHighThresholdNotificationThe h3cExtVoltageHighThresholdNotification indicates the Voltage is lower than the high-threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.4 |
h3cExtCriticalVoltageLowThresholdNotificationThe h3cExtCriticalVoltageLowThresholdNotification indicates the Voltage is lower than the critical low threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.5 |
h3cExtCriticalVoltageHighThresholdNotificationThe h3cExtCriticalVoltageHighThresholdNotification indicates the Voltage is higher than the critical high threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.6 |
h3cExtVoltageTooLowThe h3cExtVoltageTooLowNotification indicates the Voltage is lower than the critical low threshold, and the entity halt now! NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.7 |
h3cExtVoltageTooHighThe h3cExtVoltageTooHighNotification indicates the Voltage is higher than the critical high threshold, and the entity halt now! NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.8 |
h3cExtBatteryStateNotificationThe h3cExtBatteryStateNotification indicates the raid battery entity's state changes. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.9 |
h3cDiskIOErrorNotificationThe h3cDiskIOErrorNotification indicates that a disk occurred I/O error. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.10 |
h3cRaidCreateNotificationThe h3cRaidCreateNotification indicates that a array is created. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.11 |
h3cRaidDeleteNotificationThe h3cRaidDeleteStateNotification indicates that a array is deleted. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.12 |
h3cRaidHideStateNotificationThe h3cRaidFailedNotification indicates that a array hide or unhide. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.13 |
h3cRaidRunStateNotificationThe h3cRaidDegradeNotification indicates that a array state change. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.14 |
h3cRaidImportNotificationThe h3cRaidFailedNotification indicates that a thrid array is imported. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.15 |
h3cRaidRebuildStartNotificationThe h3cRaidRebuildStartNotification indicates that a array start to rebuild. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.16 |
h3cRaidRebuildFinishNotificationThe h3cRaidRebuildStartNotification indicates that a array fininsh rebuild. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.17 |
h3cRaidRebuildPauseNotificationThe h3cRaidRebuildPauseNotification indicates that pause a array rebuilding. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.18 |
h3cRaidRebuildInterruptNotificationThe h3cRaidRebuildInterruptNotification indicates that interrupt a array rebuilding. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.19 |
h3cSoftwareModuleFailNotificationThe h3cSoftwareModuleFailNotification indicates that software module(s) fail. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.20 |
h3cRaidBatteryExpiredNotificationThe h3cRaidBatteryExpiredNotification indicates RAID Battery lifetime had expired. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.21 |
h3cRaidBatteryWillExpireNotificationThe h3cRaidBatteryWillExpireNotification indicates RAID Battery lifetime will expire. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.22 |
h3cLvOnlineFailNotificationThe h3cLvOnlineFailNotification indicates lv(s) on vd fail to online. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.23 |
h3cLvOfflineFailNotificationThe h3cLvOfflineFailNotification indicates lv(s) on vd fail to offline. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.24 |
h3cRaidRunNotificationThe h3cRaidRunNotification indicates that a array is running. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.25 |
h3cExtVoltageNormalThe h3cStorVoltageRecoveryNotification indicates the Voltage has recovered in reference. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.26 |
h3cDiskPowerOnNotificationThe h3cDiskPowerOnNotification indicates that a disk is power on. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.27 |
h3cDiskPowerOffNotificationThe h3cDiskPowerOffNotification indicates that a disk is power off. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.10.1.1.3.0.28 |
h3cStorageTrapsObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.10.1.1.3.1 |
h3cSoftwareInfoStringThis object identifies if the software's information.ro H3cSoftwareInfoString (H3C-STORAGE-REF-MIB) .1.3.6.1.4.1.2011.10.10.1.1.3.1.1 |