GDCDS1-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
136
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
136 total| Object Name |
|---|
gdc OBJECT IDENTIFIER .1.3.6.1.4.1.498 |
RFC1406-MIB Unknown .1.3.6.1.4.1.498 |
csu OBJECT IDENTIFIER .1.3.6.1.4.1.498.2 |
csuConfigTableThe GDC csu Configuration Table. SEQUENCE OF CsuConfigEntry .1.3.6.1.4.1.498.2.1 |
csuConfigEntryAn entry in the GDC csu Configuration Table. CsuConfigEntry .1.3.6.1.4.1.498.2.1.1 |
csuConfigLineIndexThis object is the identifier of a DS1 interface on
a managed object. It is used to associate the DS1
Configuration Group in the standard, RFC-1406. It
should reference the dsx1LineIndex associated with
this object. This is used to expand the standard MIB
with the GDC specific information on an object.ro INTEGER .1.3.6.1.4.1.498.2.1.1.1 |
csuOnesDensityThis variable is used to indicate the pulse density
on the network side.
inhibit refers to no minimum pulse density
csuMax15Zeros refers to a maximum of 15 consecutive
zeros transmitted toward the network before
a one is inserted.
csuMax39Zeros refers to a maximum of 39 consecutive
zeros transmitted toward the network before
a one is inserted.
csu8N1Restrict refers to a minimum of N ones
per 8(N+1) bits, where N = 1 to 24; the Line Code
option for the network side must be set to AMI.
csuMin1in8 refers to a minimum of 1 one per 8 bits;
with this selection, pulse density violations are
enforced but enforcement can't be read through this MIB.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Ones Density Same as defined in managed object
552a Ones Density Same as defined in managed object
552a V1.1 Ones Density Same as defined in managed object
551 Ones Density Same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.1.1.2 |
csuFrontPanelThis variable is used to indicate whether the front
panel switches are operational or not.
inhibit refers to when the front panel switches are
not operational.
enable refers to when the front panel switches are
operational.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 None
552a None
552a V1.1 None
551 Front Panel Same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.1.1.3 |
csuInbandLoopThis variable is used to set the
In-Band DS1 Loopback Code Detection.
inhibit refers to when the in-band
loopback codes are ignored.
enable refers to when the in-band loopback codes
are detected and reacted to. When enabled, the
Loopback Configuration must also be set. When a
loopback activation or deactivation code is detected,
the DSU starts or stops the type of loopback test
selected with the Loopback Configuration.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Inband Loop Same as defined in managed object
552a Inband Loop Same as defined in managed object
552a V1.1 Inband Loop Same as defined in managed object
551 Inband Loop Same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.1.1.4 |
csuILBFrameThis variable is used to set the In-Band DS1
Loopback Code Framing option.
unframed refers to the DSU transmitting unframed in-band
loopback codes when a DS1 Remote Test is started.
framed refers to the DSU transmitting framed in-band
loopback codes when a DS1 Remote Test is started.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 ILB Frame Same as defined in managed object
552a ILB Frame Same as defined in managed object
552a V1.1 ILB Frame Same as defined in managed object
551 ILB Frame Same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.1.1.5 |
csuLineBuildOutCtrlThis variable is used to set the Network Line
Build-Out control option for the network side.
Man refers to manually setting the Network Line
Build-Out to one of the specified attenuation levels
in csuLineBuildOutValue.
Auto refers to automatic Network Line Build-Out, based
on the signal level received from the network.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Line Build-out Same as defined in managed object
552a Line Build-out Same as defined in managed object
552a V1.1 Line Build-out Same as defined in managed object
551 Line Build-out Same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.1.1.6 |
csuLineBuildOutValueThis variable is used to set the Network Line
Build-Out value on the network side.
In manual mode, these values can be written and read
back. In auto mode, a read will retreive the value
which was automatically derived and a write will have
no effect.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Line Build-out Same as defined in managed object
552a Line Build-out Same as defined in managed object
552a V1.1 Line Build-out Same as defined in managed object
551 Line Build-out Same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.1.1.7 |
csuLineTypeCtrlThis variable is used to set the Line Type
control.
None refers to the unframed mode of the DC551.
Man refers to manually setting the line type
to one of the specified types in dsx1LineType.
When set, read and write dsx1LineType for ESF or D4.
Auto refers to automatic setting of line type, based
on the framing format received from the other side.
When set, read dsx1LineType for negotiated value but,
writing dsx1LineType should be ignored.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Network Frame AUTO, MAN
552a Cascade or Network Frame AUTO, MAN
552a V1.1 Cascade or Network Frame AUTO, MAN
551 DTE or NET FRAME AUTO, MAN, NONErw Enumeration .1.3.6.1.4.1.498.2.1.1.8 |
csuAISLoopdownThis variable is used to set the AIS Loop-Down option
for remotely-initiated DS1 loopbacks.
4, inhibit, refers to when a continuous received AIS
does not terminate the loopback.
5-60, enable, refers to when a continuous received AIS
terminates the loopback. The value is used to determine
the loop-down activation time in seconds.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 AIS Loopdown inhibit, Enable-30seconds, Enable-<n> seconds
552a AIS Loopdown inhibit, Enable-30seconds, Enable-<n> seconds
552a V1.1 AIS Loopdown inhibit, Enable-30seconds, Enable-<n> seconds
551 Nonerw INTEGER .1.3.6.1.4.1.498.2.1.1.9 |
csuPreEqualizerThis variable is used to set the Cascade
PreEqualization option for matching the cascade port
line length, providing transmitter pre-equalization for
lengths of 130 ft (0-130 feet), 260 ft (130-260 feet)
390 ft (260-390 feet), 530 ft (390-530 feet) or
655 ft (530-655 feet). Selecting the proper length
ensures that the signal reaching the customer
cascade equipment is satisfactory.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 None
552a PreEqualization Same as defined in managed object
552a V1.1 PreEqualization Same as defined in managed object
551 PreEqualization Same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.1.1.10 |
csuInitializeThis variable is used to initialize specific items on
the csu,
csuAlarmHistory refers to initializing the
Alarm History Report and a new start time is recorded.
csu24HourCounter refers to initializing the 24 Hour
statistics counters. All of the counters associated
with the statistics will be initialized to zero.
csuFactoryDefaults refers to initializing all
soft-configurable options to the factory default
settings. Option 'F' from the maintenance screen.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Initialize Alarm History, Initialize Local 24 Hour Counters
552a Initialize Alarm History, Initialize Local 24 Hour Counters
552a V1.1 Initialize Alarm History, Initialize Local 24 Hour Counters
551 Initialize Alarm History, Initialize One Hourrw Enumeration .1.3.6.1.4.1.498.2.1.1.11 |
csuTimeThis variable is used to set the time for the real-time
clock located on the network element. The string is
fixed at a length of 9 octets with the format of:
hh:mm:ssA. Where hh is the hour (01-12) in 12 hour
format, mm is minutes (00-59), ss is seconds (00-59)
and A is am (A) or pm (P).
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Maintenance menu set time
552a Maintenance menu set time
552a V1.1 Maintenance menu set time
551 nonerw DisplayString .1.3.6.1.4.1.498.2.1.1.12 |
csuDateThis variable is used to set the date for the real-time
clock located on the network element. The string is
fixed at a length of 8 octets with the format of:
mm-dd-yy. Where mm is the month (01-12), dd is the day
(01-31), and yy is the year (00-99).
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Maintenance menu set date
552a Maintenance menu set date
552a V1.1 Maintenance menu set date
551 nonerw DisplayString .1.3.6.1.4.1.498.2.1.1.13 |
csuTestTypeThis variable is used to set the network side
DS1 loop type. If csuLLB is set, a line loop is
done when the proper inband loop pattern is detected.
If csuTLB is set, a test loop (or payload loop) is
done when the proper inband loop pattern is detected.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Test Type Same as defined in managed object
552a Test Type Same as defined in managed object
552a V1.1 Test Type Same as defined in managed object
551 Test Type Same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.1.1.14 |
csuReceiveLevelThis variable is used to display the current
receive level as reported by the Receive Level
screen.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Receive Level
552a Receive Level
552a V1.1 Receive Level
551 Receive Levelro DisplayString .1.3.6.1.4.1.498.2.1.1.15 |
csuChanConfigTableThe GDC csu Channel Configuration Table. SEQUENCE OF CsuChanConfigEntry .1.3.6.1.4.1.498.2.2 |
csuChanConfigEntryAn entry in the GDC csu Channel Configuration Table. CsuChanConfigEntry .1.3.6.1.4.1.498.2.2.1 |
csuChanConfigLineIndexThis object is the identifier of a DS1 interface on
a managed object. It is used to associate the DS1
Configuration Group in the standard, RFC-1406.
It should reference the dsx1LineIndex associated with
this object. This is use to expand the standard MIB
with the GDC specific information on an object.ro INTEGER .1.3.6.1.4.1.498.2.2.1.1 |
csuChanConfigNumThis variable is used to link the Fractional Group
from RFC1406 to its GDC configuration. It is linked
by the FracIfIndex in the Fractional Group from RFC1406.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Channel Number A
552a Channel Number A, B
552a V1.1 Channel Number A, B
551 Nonero INTEGER .1.3.6.1.4.1.498.2.2.1.2 |
csuStartDS0This variable is used to set the Starting DS0 Number
option for the selected channel to 0 to 24, defining
where the selected bandwidth begins. The number of DS0s
used (the DS0 bundle) depends on the equipment data
rate and whether the network accommodates Nx56 kbps
DS0s or Nx64 kbps 'Clear Channel' DS0s, and is
calculated automatically by the DSU after entering
the starting DS0.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Starting DS0 Same as defined in managed object
552a Starting DS0 Same as defined in managed object
552a V1.1 Starting DS0 Same as defined in managed object
551 Nonerw INTEGER .1.3.6.1.4.1.498.2.2.1.3 |
csuRTSCTSThis variable is used to set the CTS operation
option for the selected channel.
csuCTSDelayed refers to CTS responding to RTS
after a 10 ms delay.
csuCTSForcedOn refers to CTS forced ON at all times.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 RTS to CTS Option Same as defined in managed object
552a RTS to CTS Option Same as defined in managed object
552a V1.1 RTS to CTS Option Same as defined in managed object
551 Nonerw Enumeration .1.3.6.1.4.1.498.2.2.1.4 |
csuControlModeIdleThis variable is used to set the CMI Signalling
option for the selected channel.
off refers to when the CMI signalling is disabled.
on refers to when the CMI signalling is enabled
for use in polling applications on 56 kbps DDS I
lines with remote DSUs.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Control Mode Idle Same as defined in managed object
552a Control Mode Idle Same as defined in managed object
552a V1.1 Control Mode Idle Same as defined in managed object
551 Nonerw Enumeration .1.3.6.1.4.1.498.2.2.1.5 |
csuRDLInbandCodeThis variable is used to set the Remote Digital
Loop Pattern option for the selected channel.
csuFixed refers to a proprietary 7-bit loop-up/down
in-band codes for RDL.
csuPN127 refers to CCITT V.54 PN-127 scrambled codes.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 RDL Inband Code Same as defined in managed object
552a RDL Inband Code Same as defined in managed object
552a V1.1 RDL Inband Code Same as defined in managed object
551 Nonerw Enumeration .1.3.6.1.4.1.498.2.2.1.6 |
csuChanRateThis variable is used to setup the channel rate used
by the DSU to calculate the number of DS0s, or
bandwidth, required for the channel. The rate depends
on the equipment data rate and must equal or exceed it.
The available range is from 0 kbps to 1536 kbps,
in multiples of Nx56 kbps and Nx64 kbps.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Channel Rate Same as defined in managed object
552a Channel Rate Same as defined in managed object
552a V1.1 Channel Rate Same as defined in managed object
551 Nonerw INTEGER .1.3.6.1.4.1.498.2.2.1.7 |
csuAlternateDS0This variable is used to set the Alternate DS0 option.
off refers to channel data that is carried in
consecutive blocks of DS0s and the full T1 bandwidth
is available for customer data.
on refers to the channel data that is carried in
alternate DS0s, with unused DS0s carrying all ones.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Alternate DS0 Same as defined in managed object
552a Alternate DS0 Same as defined in managed object
552a V1.1 Alternate DS0 Same as defined in managed object
551 Nonerw Enumeration .1.3.6.1.4.1.498.2.2.1.8 |
csuRespondRDLThis variable is used to set the Channel
RDL Response option.
no refers to the channel ignores in-band loopback codes.
yes refers to when the channel responds to in-band
loopback codes for Digital Loop received from the
network or the remote DSU.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Respond RDL Same as defined in managed object
552a Respond RDL Same as defined in managed object
552a V1.1 Respond RDL Same as defined in managed object
551 Nonerw Enumeration .1.3.6.1.4.1.498.2.2.1.9 |
csuInbandDLTimeoutThis variable is used to set the Channel Digital
Loop Timer option for remotely-initiated
Channel Digital Loop tests.
inhibit refers to when the test is unaffected.
csuEnable10Min refers to when the test is terminated
after 10 minutes.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Inband DL Time-out Same as defined in managed object
552a Inband DL Time-out Same as defined in managed object
552a V1.1 Inband DL Time-out Same as defined in managed object
551 Nonerw Enumeration .1.3.6.1.4.1.498.2.2.1.10 |
csuChanStatusThis variable is used to read the status of the
channel. Each bit in the csuChanStatus indicates
some status information.
NoAlarm bit 1 Everything is ok
ConfigErr bit 2 A configuration error existsro INTEGER .1.3.6.1.4.1.498.2.2.1.11 |
csuChan6456This value is used by the csu if the value of
csuChanRate is a multiple of both 56 & 64. This
value is not used if dsx1FracNumber is used to
configure the csu. In that case dsx1LineCoding
will determine the channel rate if there is a
common multiple.
write to this variable:
1) snmp set
2) dividing csuChanRate by the number of ds0s
found in dsx1FracNumber
read from this variable:
1) dividing csuChanRate by the number of ds0s
found in dsx1FracNumberrw Enumeration .1.3.6.1.4.1.498.2.2.1.12 |
csuIndicatorTableThe GDC csu Indicator Table. SEQUENCE OF CsuIndicatorEntry .1.3.6.1.4.1.498.2.3 |
csuIndicatorEntryAn entry in the GDC Indicator Table. CsuIndicatorEntry .1.3.6.1.4.1.498.2.3.1 |
csuIndicatorIndexThis object is the identifier of a DS1 interface on
a managed object. It is used to associate the DS1
Configuration Group in the standard, RFC-1406.
It should reference the dsx1LineIndex associated with
this object. This is use to expand the standard MIB
with the GDC specific information on an object.ro INTEGER .1.3.6.1.4.1.498.2.3.1.1 |
csuIndicatorOOFThis object is the Network Out of Frame indicator.
It indicates whether the CSU/DSU is or is not
synchronized with network framing. In a CSU this
is also known as Network Synchronization (SYN).
GDCPRODUCT STATUS BAR
551 SYN
551 (unframed) none
552a OOF
552a-1 OOFro Enumeration .1.3.6.1.4.1.498.2.3.1.2 |
csuIndicatorNNSThis object is the Network No Signal indicator.
It indicates whether the CSU/DSU is or is not
receiving a network signal.
GDCPRODUCT STATUS BAR
551 NNS
551 (unframed) NNS
552a NS
552a-1 NSro Enumeration .1.3.6.1.4.1.498.2.3.1.3 |
csuIndicatorYELThis object is the Network Yellow Alarm receive
indicator. It indicates whether the CSU/DSU is or
is not receiving a network yellow alarm.
GDCPRODUCT STATUS BAR
551 YEL
551 (unframed) none
552a YEL
552a-1 YELro Enumeration .1.3.6.1.4.1.498.2.3.1.4 |
csuIndicatorAISThis object is the Network Alarm Indication Signal
indicator. It indicates whether the CSU/DSU is or
is not receiving AIS from the network.
GDCPRODUCT STATUS BAR
551 AIS
551 (unframed) none
552a AIS
552a-1 AISro Enumeration .1.3.6.1.4.1.498.2.3.1.5 |
csuIndicatorNLBThis object is the Network Loopback indicator.
It indicates whether the CSU/DSU is or is not
in a DS1 loopback test towards the network.
GDCPRODUCT STATUS BAR
551 NLB
551 (unframed) NLB
552a NLB
552a-1 NLBro Enumeration .1.3.6.1.4.1.498.2.3.1.6 |
csuIndicatorBPVThis object is the Network BiPolar Violation indicator.
It indicates whether the CSU/DSU has or has not
received a BPV.
GDCPRODUCT STATUS BAR
551 BPV
551 (unframed) BPV
552a BPV
552a-1 BPVro Enumeration .1.3.6.1.4.1.498.2.3.1.7 |
csuIndicatorCRCThis object is the Network Cyclic Redundancy Check
indicator. It indicates whether the CSU/DSU has
or has not received a CRC error.
GDCPRODUCT STATUS BAR
551 CRC
551 (unframed) none
552a CRC
552a-1 CRCro Enumeration .1.3.6.1.4.1.498.2.3.1.8 |
csuIndicatorTSYThis object is the Terminal Equipment Synchronization
indicator. It indicates whether the CSU is or
is not synchronized with equipment framing.
GDCPRODUCT STATUS BAR
551 TSY
551 (unframed) none
552a none
552a-1 nonero Enumeration .1.3.6.1.4.1.498.2.3.1.9 |
csuIndicatorTNSThis object is the Terminal No Signal
indicator. It indicates whether the CSU is or
is not receiving an equipment signal.
GDCPRODUCT STATUS BAR
551 TNS
551 (unframed) TNS
552a none
552a-1 nonero Enumeration .1.3.6.1.4.1.498.2.3.1.10 |
csuIndicatorOSThis object is the Equipment Zero's
indicator. It indicates whether the CSU is or
is not receiving an excessive number of
consecutive zero's (see one's density option).
GDCPRODUCT STATUS BAR
551 0'S
551 (unframed) 0'S
552a none
552a-1 nonero Enumeration .1.3.6.1.4.1.498.2.3.1.11 |
csuIndicatorLADThis object is the Low Average Density
indicator. It indicates whether the CSU is or
is not receiving an average pulse density less
than that selected with the one's density option.
GDCPRODUCT STATUS BAR
551 LAD
551 (unframed) LAD
552a none
552a-1 nonero Enumeration .1.3.6.1.4.1.498.2.3.1.12 |
csuIndicatorCascadeOOFThis object is the Cascade Out of Frame
indicator. It indicates whether the T1 Cascade port
is or is not synchronized with customer cascade
equipment framing.
GDCPRODUCT STATUS BAR
551 none
551 (unframed) none
552a OOF
552a-1 nonero Enumeration .1.3.6.1.4.1.498.2.3.1.13 |
csuIndicatorCascadeNSThis object is the Cascade No Signal indicator.
It indicates whether the T1 Cascade port is or
is not receiving a customer cascade equipment
signal.
GDCPRODUCT STATUS BAR
551 none
551 (unframed) none
552a NS
552a-1 nonero Enumeration .1.3.6.1.4.1.498.2.3.1.14 |
csuIndicatorNetworkLTThis object is the Local Test indicator.
It indicates whether the DS1 local test is or
is not active.
GDCPRODUCT STATUS BAR
551 LT
551 (unframed) LT
552a LT
552a-1 LTro Enumeration .1.3.6.1.4.1.498.2.3.1.15 |
csuIndicatorNetworkSTThis object is the Self Test indicator.
It indicates whether the DS0 self test, DS1 self
test or no self test is active.
GDCPRODUCT STATUS BAR
551 ST
551 (unframed) ST
552a ST
552a-1 STro Enumeration .1.3.6.1.4.1.498.2.3.1.16 |
csuIndicatorNetworkRTThis object is the DS1 Remote Test indicator.
It indicates whether the DS1 remote test is or
is not active.
GDCPRODUCT STATUS BAR
551 RT
551 (unframed) RT
552a RT
552a-1 RTro Enumeration .1.3.6.1.4.1.498.2.3.1.17 |
csuIndicatorChannelRDLThis object is the channel Remote Digital Loopback
indicator. It indicates whether the channel Remote
Digital Loop is active on channel A, active on
channel B or is not active.
GDCPRODUCT STATUS BAR
551 none
551 (unframed) none
552a RDL
552a-1 RDLro Enumeration .1.3.6.1.4.1.498.2.3.1.18 |
csuIndicatorChannelSTThis object is the channel Self Test indicator.
It indicates whether the channel Self Test is
active on channel A, active on channel B or
is not active.
GDCPRODUCT STATUS BAR
551 none
551 (unframed) none
552a ST
552a-1 STro Enumeration .1.3.6.1.4.1.498.2.3.1.19 |
csuIndicatorChannelDLThis object is the channel Digital Loopback indicator.
It indicates whether the channel Digital Loop is
active on channel A, active on channel B, active on
both channels A and B or is not active.
GDCPRODUCT STATUS BAR
551 none
551 (unframed) none
552a DL
552a-1 DLro Enumeration .1.3.6.1.4.1.498.2.3.1.20 |
csuIndicatorChannelLLThis object is the channel Local Loopback indicator.
It indicates whether the channel Local Loop is
active on channel A, active on channel B
or is not active.
GDCPRODUCT STATUS BAR
551 none
551 (unframed) none
552a LL
552a-1 LLro Enumeration .1.3.6.1.4.1.498.2.3.1.21 |
csuIndicatorModeThis object is the unit mode indicator.
It indicates whether the CSU/DSU is in hard (or LOR)
mode where on board DIP switches are used or soft
mode where programmable options are allowed.
GDCPRODUCT STATUS BAR
551 LOR
551 (unframed) LOR
552a HARD
552a-1 HARDro Enumeration .1.3.6.1.4.1.498.2.3.1.22 |
csuIndicatorDS0LBThis object is the DS) Loopback indicator.
It indicates whether DS0 loopback at the local
CSU is active or not.
GDCPRODUCT STATUS BAR
551 DS0LB
551 (unframed) none
552a none
552a-1 nonero Enumeration .1.3.6.1.4.1.498.2.3.1.23 |
csuSelftestDiagTableThe GDC csu Selftest Diagnostic Table. SEQUENCE OF CsuSelftestDiagEntry .1.3.6.1.4.1.498.2.4 |
csuSelftestDiagEntryAn entry in the GDC csu Selftest Diagnostic Table. CsuSelftestDiagEntry .1.3.6.1.4.1.498.2.4.1 |
csuSelftestDiagLineIndexThis object is the identifier of a DS1 interface on
a managed object. It is used to associate the DS1
Configuration Group in the standard, RFC-1406.
It should reference the dsx1LineIndex associated with
this object. This is use to expand the standard MIB
with the GDC specific information on an object.ro INTEGER .1.3.6.1.4.1.498.2.4.1.1 |
csuDiagSelftestThis variable is used to indicate whether a selftest
is currently on going. This will allow a Loopback to
occur while a selftest is occurring.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Selftest Same as defined in managed object
552a Selftest Same as defined in managed object
552a V1.1 Selftest Same as defined in managed object
551 Selftest Same as defined in managed objectrwobsolete Enumeration .1.3.6.1.4.1.498.2.4.1.2 |
csuGDCSelftestPatternThis variable is used in conjunction with the
dsx1SendCode managed object in the RFC1406
Configuration Group. It selects the test pattern
to be used in the BIT ERROR TEST mode.
csu2047 refers to 2047-bit test pattern. When set,
the 2047 selftest will start.
csuPROG refers to a user-programmable test pattern.
The pattern is defined in csuSelftestUserPattern.
When set, the programmable pattern selftest will start.
When dsx1SendCode is set to dsx1SendNoCode, these
tests will stop.
When the GDC specific test patterns defined here
are used, reading dsx1SendCode will return
dsx1SendOtherTestPattern. When the test patterns
from dsx1SendCode are set, this object returns other.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Selftest Pattern Same as defined in managed object
552a Selftest Pattern Same as defined in managed object
552a V1.1 Selftest Pattern Same as defined in managed object
551 Selftest Pattern Same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.4.1.3 |
csuSelftestUserPatternThis variable contains a user specified 16 bit
pattern that will be sent during a selftest.
The default pattern is 1100000000000000.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Selftest User Pattern default, pattern
552a Selftest User Pattern default, pattern
552a V1.1 Selftest User Pattern default, pattern
551 Selftest User Pattern default, patternrw DisplayString .1.3.6.1.4.1.498.2.4.1.4 |
csuSelftestFrameThis variable is used to set whether the self test
pattern is ESF/D4 framed or not.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 None
552a None
552a V1.1 None
551 Selftest Frame Same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.4.1.5 |
csuSelftestResultsThis variable is used to read the results of the
selftest. BER Inactive is used to indicate that no
selftest is running, otherwise the number of errors.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Test Results Same as defined in managed object
552a Test Results Same as defined in managed object
552a V1.1 Test Results Same as defined in managed object
551 Test Results Same as defined in managed objectro DisplayString .1.3.6.1.4.1.498.2.4.1.6 |
csuSelftestTimeThis variable is used to read the active test time.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Test Time Same as defined in managed object
552a Test Time Same as defined in managed object
552a V1.1 Test Time Same as defined in managed object
551 Test Time Same as defined in managed objectro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.498.2.4.1.7 |
csuLoopbackDiagTableThe GDC csu Loopback Diagnostic Table. SEQUENCE OF CsuLoopbackDiagEntry .1.3.6.1.4.1.498.2.5 |
csuLoopbackDiagEntryAn entry in the GDC csu Loopback Diagnostic Table. CsuLoopbackDiagEntry .1.3.6.1.4.1.498.2.5.1 |
csuLoopbackDiagLineIndexThis object is the identifier of a DS1 interface on a
managed object. It is used to associate the DS1
Configuration Group in the standard, RFC-1406. It should
reference the dsx1LineIndex associated with this object.
This is use to expand the standard MIB with the GDC
specific information on an object.ro INTEGER .1.3.6.1.4.1.498.2.5.1.1 |
csuGDCLoopbackThis variable is used to initiate a specific test. It
is used in conjunction with the dsx1LoopbackConfig
managed object in RFC1406 Configuration Group.
Setting dsx1NoLoop(1) stops all tests.
Setting dsx1PayloadLoop(2) or dsx1LineLoop(3) causes
that test to start as well as automatically setting
this variable to other(1).
other indicates that the dsx1LoopbackConfig option
should be checked.
The rest of the options have the following in common:
Setting any of them causes that test to start as well
as automatically setting dsx1LoopbackConfig
to dsx1OtherLoop(4).
csuLocalTest refers to a test that transmits a
locally-generated test message through the DSU and
looping it back at the network interface to the test
equipment for verification. During this test, data is
also transmitted to the T1 link, with pulse density
constraints, but data is not received from the
cascade port or the line.
csuNILoop refers a test that tests the local DSU and
the T1 link by transmitting a locally-generated test
message through the local DSU to the remote DS1
Interface Connector and looping it back to the test
equipment for verification.
csuCascadeDigitalLoop refers to a test that tests both
DSUs' circuitry and the T1 link by transmitting a
remotely-generated test message through the remote DSU
to the local DSU's cascade port interface and looping
it back to the test equipment for verification. This
test loops only those DS0s allocated to equipment on
the cascade side of the local DSU. DS0s allocated to
the local DSU or to the DSU on the network side of
T1 are unaffected.
csuRemoteLoop refers to a test that activates the
remote DSU's DS1 Line Loopback function or DS1 Test
Loopback function, depending on which one is enabled
in the remote DSU. This tests both DSUs and the T1 link
by transmitting a locally-generated test message through
the local DSU to the remote DSU and looping it back to
the test equipment for verification. Bipolar violations
are uncorrected during this test when the remote DSU
has its LLB function enabled.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Loopback Test Loop, Line Loop, Local Test, Remote Test,
NI Loop
552a Loopback Test Loop, Line Loop, Local Test, Remote Test,
NI Loop, Cascade Digital Loop
552a V1.1 Loopback Test Loop, Line Loop, Local Test, Remote Test,
NI Loop, Cascade Digital Loop
551 Loopback Test Loop, Line Loop, Local Test, Remote Test,
NI Looprw Enumeration .1.3.6.1.4.1.498.2.5.1.2 |
csuDS0DiagTableThe GDC csu DS0 Diagnostic Table. SEQUENCE OF CsuDS0DiagEntry .1.3.6.1.4.1.498.2.6 |
csuDS0DiagEntryAn entry in the GDC csu DS0 Diagnostic Table. CsuDS0DiagEntry .1.3.6.1.4.1.498.2.6.1 |
csuDS0LineIndexThis object is used to associate DS0s withe the
appropriate DS1 interface on a managed object. It is
used to associate the DS1 Configuration Group in the
standard, RFC-1406. It should reference the
dsx1LineIndex associated with this object. This is used
to expand the standard MIB with the GDC specific
information on an object.ro INTEGER .1.3.6.1.4.1.498.2.6.1.1 |
csuDS0NumThis variable holds the DS0 number under test.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 DS0 Channel Number same as defined in managed object
552a DS0 Channel Number same as defined in managed object
552a V1.1 DS0 Channel Number same as defined in managed object
551 DS0 Channel Number same as defined in managed objectrw INTEGER .1.3.6.1.4.1.498.2.6.1.2 |
csuTestPatternThis variable holds the test pattern the DS0
will use for testing.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Test Pattern 511, QRS and 2047
552a Test Pattern 511, QRS and 2047
552a V1.1 Test Pattern 511, QRS and 2047
551 Test Pattern 511, QRS and 2047rw Enumeration .1.3.6.1.4.1.498.2.6.1.3 |
csuResetResultsThis variable is used to reset the results
from the previous test.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Reset Test Results same as defined in managed object
552a Reset Test Results same as defined in managed object
552a V1.1 Reset Test Results same as defined in managed object
551 Reset Test Results same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.6.1.4 |
csuBERtestThis variable is used to control the DS0 BER test.
It controls a combination of 'M', Test Mode to
BIT ERROR TEST and 'I', Initiate Test for on(2)
and 'T', Terminate Test for off(1).
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 BIT ERROR TEST same as defined in managed object
552a BIT ERROR TEST same as defined in managed object
552a V1.1 BIT ERROR TEST same as defined in managed object
551 BIT ERROR TEST same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.6.1.5 |
csuCumErrsThis variable is used to read the cumulative errors
counted during the test.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Cumulative Errors same as defined in managed object
552a Cumulative Errors same as defined in managed object
552a V1.1 Cumulative Errors same as defined in managed object
551 Cumulative Errors same as defined in managed objectro DisplayString .1.3.6.1.4.1.498.2.6.1.6 |
csuDataBlocksThis variable is used to read the number of
blocks tested.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Test Data Blocks same as defined in managed object
552a Test Data Blocks same as defined in managed object
552a V1.1 Test Data Blocks same as defined in managed object
551 Test Data Blocks same as defined in managed objectro DisplayString .1.3.6.1.4.1.498.2.6.1.7 |
csuCircuitDelayCtrlThis variable is used to control the circuit delay
test. It controls a combination of 'M', Test Mode to
DELAY TEST and 'I', Initiate Test. A write of any value
begins the test. The test ends by itself within
within 2 seconds.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Circuit Delay same as defined in managed object
552a Circuit Delay same as defined in managed object
552a V1.1 Circuit Delay same as defined in managed object
551 Circuit Delay same as defined in managed objectrw INTEGER .1.3.6.1.4.1.498.2.6.1.8 |
csuCircuitDelayResultThis variable is used to read the circuit delay
detected during the test.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Circuit Delay same as defined in managed object
552a Circuit Delay same as defined in managed object
552a V1.1 Circuit Delay same as defined in managed object
551 Circuit Delay same as defined in managed objectro DisplayString .1.3.6.1.4.1.498.2.6.1.9 |
csuLBtestThis variable is used to control the DS0 LOOPBACK test.
It controls a combination of 'M', Test Mode to
LOOPBACK and 'I', Initiate Test for DS0LBon(2)
and 'T', Terminate Test for DS0LBoff(1).
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 LOOPBACK same as defined in managed object
552a LOOPBACK same as defined in managed object
552a V1.1 LOOPBACK same as defined in managed object
551 LOOPBACK same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.6.1.10 |
csuChanDiagTableThe GDC csu Channel Diagnostic Table. SEQUENCE OF CsuChanDiagEntry .1.3.6.1.4.1.498.2.7 |
csuChanDiagEntryAn entry in the GDC csu Channel Diagnostic Table. CsuChanDiagEntry .1.3.6.1.4.1.498.2.7.1 |
csuChanLineIndexThis object is the identifier of a DS1 interface on
a managed object. It is used to associate the DS1
Configuration Group in the standard, RFC-1406.
It should reference the dsx1LineIndex associated with
this object. This is use to expand the standard MIB
with the GDC specific information on an object.ro INTEGER .1.3.6.1.4.1.498.2.7.1.1 |
csuChanNumThis variable is used to link the Fractional Group
from RFC1406 to its GDC configuration. It is linked by
the FracIfIndex in the Fractional Group from RFC1406.ro INTEGER .1.3.6.1.4.1.498.2.7.1.2 |
csuChanSelftestThis variable is used start and stop the selftest
on the channel.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Selftest same as defined in managed object
552a Selftest same as defined in managed object
552a V1.1 Selftest same as defined in managed object
551 Nonerw Enumeration .1.3.6.1.4.1.498.2.7.1.3 |
csuChanLoopbackThis variable is used to initiate a channel test.
NoLoop refers to when no test is currently being
performed, it also is used to terminate a test.
csuRDL refers to a test that tests the local channel
equipment, both DSUs and the T1 link. It does so by
transmitting a locally-generated test message through
the local DSU to the remote DSU, looping it back at the
remote channel interface, and returning it to the test
equipment for verification. Loopback of the remote
channel is controlled by in-band loopback codes
transmitted by the local DSU after starting
or stopping the test.
csuDL refers to a test that tests the remote channel
equipment, both DSUs and the T1 link. It does so by
transmitting a remotely-generated test message through
the remote DSU to the local DSU, looping it back at
the local channel interface, and returning it to the
test equipment for verification.
csuLL refers to a test that tests the local channel
equipment and the local DSU. It does so by transmitting
a locally-generated test message through the local DSU,
looping it back at the local multiplexer interface,
and returning it to the test equipment for verification.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Channel Diagnostic RDL, DL, LL
552a Channel Diagnostic RDL, DL, LL
552a V1.1 Channel Diagnostic RDL, DL, LL
551 Nonerw Enumeration .1.3.6.1.4.1.498.2.7.1.4 |
csuChanSelftestStatusThis variable is used to read the results of the
selftest. The value will be OFF, Chx NO ERRORS
or ChX ERRORS - Proceed to DS0 test
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Test Results Same as defined in managed object
552a Test Results Same as defined in managed object
552a V1.1 Test Results Same as defined in managed object
551 Nonero DisplayString .1.3.6.1.4.1.498.2.7.1.5 |
csuAlarmHistoryTableThe GDC csu Alarm History Table. SEQUENCE OF CsuAlarmHistoryEntry .1.3.6.1.4.1.498.2.8 |
csuAlarmHistoryEntryAn entry in the GDC csu Alarm History Table. CsuAlarmHistoryEntry .1.3.6.1.4.1.498.2.8.1 |
csuAlarmHistoryIndexThis object is the identifier of a DS1 interface on
a managed object. It is used to associate the DS1
Configuration Group in the standard, RFC-1406.
It should reference the dsx1LineIndex associated with
this object. This is used to expand the standard MIB
with the GDC specific information on an object.ro INTEGER .1.3.6.1.4.1.498.2.8.1.1 |
csuAlarmTypeThis variable is used to indicate the alarm that
the count, first occurance and last occurance
is associated with.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Major/Minor/Other NLOS, NOOF, AI, FSS, RY, EZ, LAD,
BPV, CRC,CS
552a Major/Minor/Other NLOS, NOOF, AI, FSS, RY, EZ, LAD,
BPV, CRC, CS, CLOF, COOF
552a V1.1 Major/Minor/Other NLOS, NOOF, AI, FSS, RY, EZ, LAD,
BPV, CRC, CS, USS, CLOF, COOF
551 Nonero Enumeration .1.3.6.1.4.1.498.2.8.1.2 |
csuAlarmHistoryStartThis variable is used to hold when the
alarm history was initialized.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Initialized Time and Date
552a Initialized Time and Date
552a V1.1 Start Time Time and Date
551 Elapsed Time Hours and Minutesro DisplayString .1.3.6.1.4.1.498.2.8.1.3 |
csuCountThis is used to indicate the number of recorded events
of each of the listed errors, since the alarm history
was initialized or cleared.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Count Same as defined in managed object
552a Count Same as defined in managed object
552a V1.1 Count Same as defined in managed object
551 Count Same as defined in managed objectro Gauge .1.3.6.1.4.1.498.2.8.1.4 |
csuFirstOccurThis variable is used to indicate when a specific
alarm first occurred since last initialized.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 First Occurance Time and Date
552a First Occurance Time and Date
552a V1.1 First Occurance Time and Date
551 Nonero DisplayString .1.3.6.1.4.1.498.2.8.1.5 |
csuLastOccurThis variable is used to indicate when the
last alarm occurred.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Last Occurance Time and Date
552a Last Occurance Time and Date
552a V1.1 Last Occurance Time and Date
551 Nonero DisplayString .1.3.6.1.4.1.498.2.8.1.6 |
csuSchedPerfRprtTableThe GDC csu Scheduled Performance Report Table. SEQUENCE OF CsuSchedPerfRprtEntry .1.3.6.1.4.1.498.2.9 |
csuSchedPerfRprtEntryAn entry in the GDC csu Scheduled Performance Report
Table. CsuSchedPerfRprtEntry .1.3.6.1.4.1.498.2.9.1 |
csuSchedPerfRprtIndexThis object is the identifier of a DS1 interface on a
managed object. It is used to associate the DS1
Configuration Group in the standard, RFC-1406.
It should reference the dsx1LineIndex associated with
this object. This is use to expand the standard MIB
with the GDC specific information on an object.ro INTEGER .1.3.6.1.4.1.498.2.9.1.1 |
csuPerfRprtIntervalNumberA number between 1 and 4 denoting a 1 second interval.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Interval 1st, 2nd, 3rd, 4th
552a Interval 1st, 2nd, 3rd, 4th
552a V1.1 Interval 1st, 2nd, 3rd, 4th
551 Interval 1st, 2nd, 3rd, 4thro INTEGER .1.3.6.1.4.1.498.2.9.1.2 |
csuPerfRprtMsgThis variable is used to toggle between the
Performance Report Message transmitted toward the
network, outbound, and received from the network,
inbound.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 Performance Report Same as defined in managed object
552a Performance Report Same as defined in managed object
552a V1.1 Performance Report Same as defined in managed object
551 Performance Report Same as defined in managed objectrw Enumeration .1.3.6.1.4.1.498.2.9.1.3 |
csuCRCErrEventThis variable is used to indicate the CRC-6 Error
Events. They are displayed in the ranges specified.
RANGE DESCRIPTION SCREEN
NoErrors no errors exist 0
OneError one error 1
LessFive 2-4 errors <5
LessTen 5-9 errors <10
Less100 10-99 errors <100
Less320 100-319 errors <320
Greater320 320 or more errors >320
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 CRC Error Event Same as defined in managed object
552a CRC Error Event Same as defined in managed object
552a V1.1 CRC Error Event Same as defined in managed object
551 CRC Error Event Same as defined in managed objectro Enumeration .1.3.6.1.4.1.498.2.9.1.4 |
csuSEEventThis variable is used to indicate Severe Error Events.
RANGE DESCRIPTION SCREEN
NoErrors 0 errors .
OneOrMore 1 or more errors *
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 SE Event Same as defined in managed object
552a SE Event Same as defined in managed object
552a V1.1 SE Event Same as defined in managed object
551 SE Event Same as defined in managed objectro Enumeration .1.3.6.1.4.1.498.2.9.1.5 |
csuFEEventThis variable is used to indicate a Frame Error Event.
RANGE DESCRIPTION SCREEN
NoErrors 0 errors .
OneOrMore 1 or more errors *
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 FE Event Same as defined in managed object
552a FE Event Same as defined in managed object
552a V1.1 FE Event Same as defined in managed object
551 FE Event Same as defined in managed objectro Enumeration .1.3.6.1.4.1.498.2.9.1.6 |
csuCVEventThis variable is used to indicate Code Violation Event.
RANGE DESCRIPTION SCREEN
NoErrors 0 errors .
OneOrMore 1 or more errors *
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 CV Event Same as defined in managed object
552a CV Event Same as defined in managed object
552a V1.1 CV Event Same as defined in managed object
551 CV Event Same as defined in managed objectro Enumeration .1.3.6.1.4.1.498.2.9.1.7 |
csuCSEventThis variable is used to indicate Controlled Slip Event
RANGE DESCRIPTION SCREEN
NoErrors 0 errors .
OneOrMore 1 or more errors *
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 CS Event Same as defined in managed object
552a CS Event Same as defined in managed object
552a V1.1 CS Event Same as defined in managed object
551 CS Event Same as defined in managed objectro Enumeration .1.3.6.1.4.1.498.2.9.1.8 |
csuAPLoopThis variable is used to indicate Active Payload Loop
condition occurred, this is the looping back toward the
network frames consisting of the received 192
information bits plus its own frame in, CRC-6,
and Data Link bits.
RANGE DESCRIPTION SCREEN
NoErrors 0 errors .
InPayload in payload *
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 AP Loop Same as defined in managed object
552a AP Loop Same as defined in managed object
552a V1.1 AP Loop Same as defined in managed object
551 AP Loop Same as defined in managed objectro Enumeration .1.3.6.1.4.1.498.2.9.1.9 |
csuCurrentStatsTableThe GDC csu Current Statistics Table. SEQUENCE OF CsuCurrentStatsEntry .1.3.6.1.4.1.498.2.10 |
csuCurrentStatsEntryAn entry in the GDC csu Scheduled Performance
Report Table. CsuCurrentStatsEntry .1.3.6.1.4.1.498.2.10.1 |
csuCurrentIndexThe index value which uniquely identifies the DS1
interface to which this entry is applicable.
The interface identified by a particular value of this
index is the same interface as identified by the same
value as a dsx1LineIndex object instance.ro INTEGER .1.3.6.1.4.1.498.2.10.1.1 |
csuCurrentLOFCThe number of Loss of Frame Count encountered by a
DS1 interface in the current 15 minute interval.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 None
552a None
552a V1.1 LOFC
551 Nonero Gauge .1.3.6.1.4.1.498.2.10.1.2 |
csuIntervalStatsTableThe GDC csu Interval Statistics Table. SEQUENCE OF CsuIntervalStatsEntry .1.3.6.1.4.1.498.2.11 |
csuIntervalStatsEntryAn entry in the GDC csu Scheduled Performance
Report Table. CsuIntervalStatsEntry .1.3.6.1.4.1.498.2.11.1 |
csuIntervalIndexThe index value which uniquely identifies the DS1
interface to which this entry is applicable.
The interface identified by a particular value of this
index is the same interface as identified by the same
value as a dsx1LineIndex object instance.ro INTEGER .1.3.6.1.4.1.498.2.11.1.1 |
csuIntervalNumberA number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minute interval
(assuming tht all 96 intervals are valid).ro INTEGER .1.3.6.1.4.1.498.2.11.1.2 |
csuIntervalLOFCThe number of Loss of Frame Count encountered by a
DS1 interface in one of the previous 96,
individual 15 minute, intervals.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 None
552a None
552a V1.1 LOFC
551 Nonero Gauge .1.3.6.1.4.1.498.2.11.1.3 |
csuTotalStatsTableThe GDC csu Total Statistics Table. SEQUENCE OF CsuTotalStatsEntry .1.3.6.1.4.1.498.2.12 |
csuTotalStatsEntryAn entry in the GDC csu Scheduled Performance Report Table. CsuTotalStatsEntry .1.3.6.1.4.1.498.2.12.1 |
csuTotalIndexThe index value which uniquely identifies the DS1
interface to which this entry is applicable.
The interface identified by a particular value of this
index is the same interface as identified by the same
value as a dsx1LineIndex object instance.ro INTEGER .1.3.6.1.4.1.498.2.12.1.1 |
csuTotalLOFCThe number of Loss of Frame Count encountered by a
DS1 interface in the previous 24 hour interval.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 None
552a None
552a V1.1 LOFC
551 Nonero Gauge .1.3.6.1.4.1.498.2.12.1.2 |
csuFarEndCurrentStatsTableThe GDC csu Current Statistics Table. SEQUENCE OF CsuFarEndCurrentStatsEntry .1.3.6.1.4.1.498.2.13 |
csuFarEndCurrentStatsEntryAn entry in the GDC csu Scheduled Performance
Report Table. CsuFarEndCurrentStatsEntry .1.3.6.1.4.1.498.2.13.1 |
csuFarEndCurrentIndexThe index value which uniquely identifies the DS1
interface to which this entry is applicable.
The interface identified by a particular value of this
index is the same interface as identified by the same
value as a dsx1LineIndex object instance.ro INTEGER .1.3.6.1.4.1.498.2.13.1.1 |
csuFarEndCurrentLOFCThe number of LOFC encountered by a DS1 interface
in the current 15 minute interval.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 None
552a None
552a V1.1 LOFC
551 Nonero Gauge .1.3.6.1.4.1.498.2.13.1.2 |
csuFarEndIntervalStatsTableThe GDC csu Interval Statistics Table. SEQUENCE OF CsuFarEndIntervalStatsEntry .1.3.6.1.4.1.498.2.14 |
csuFarEndIntervalStatsEntryAn entry in the GDC csu Scheduled Performance
Report Table. CsuFarEndIntervalStatsEntry .1.3.6.1.4.1.498.2.14.1 |
csuFarEndIntervalIndexThe index value which uniquely identifies the DS1
interface to which this entry is applicable.
The interface identified by a particular value of this
index is the same interface as identified by the same
value as a dsx1LineIndex object instance.ro INTEGER .1.3.6.1.4.1.498.2.14.1.1 |
csuFarEndIntervalNumberA number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minute interval
(assuming tht all 96 intervals are valid).ro INTEGER .1.3.6.1.4.1.498.2.14.1.2 |
csuFarEndIntervalLOFCThe number of LOFC encountered by a DS1 interface in
one of the previous 96, individual 15 minute, intervals.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 None
552a None
552a V1.1 LOFC
551 Nonero Gauge .1.3.6.1.4.1.498.2.14.1.3 |
csuFarEndTotalStatsTableThe GDC csu Total Statistics Table. SEQUENCE OF CsuFarEndTotalStatsEntry .1.3.6.1.4.1.498.2.15 |
csuFarEndTotalStatsEntryAn entry in the GDC csu Scheduled Performance
Report Table. CsuFarEndTotalStatsEntry .1.3.6.1.4.1.498.2.15.1 |
csuFarEndTotalIndexThe index value which uniquely identifies the DS1
interface to which this entry is applicable.
The interface identified by a particular value of this
index is the same interface as identified by the same
value as a dsx1LineIndex object instance.ro INTEGER .1.3.6.1.4.1.498.2.15.1.1 |
csuFarEndTotalLOFCThe number of LOFC encountered by a DS1 interface
in the previous 24 hour interval.
GDCPRODUCT EQUIVALENT POSSIBLESELECTIONS
552a-1 None
552a None
552a V1.1 LOFC
551 Nonero Gauge .1.3.6.1.4.1.498.2.15.1.2 |