Home/Catalog/DKSF-50-11-X-X-X

DKSF-50-11-X-X-X

Generic MIB for NetPing remote sensing and control
Main OID:
netPing.1.3.6.1.4.1.25728.50
85
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

85 total
Object Name
lightcom
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728
netPingGeneric MIB for NetPing remote sensing and control
MODULE-IDENTITY
.1.3.6.1.4.1.25728.50
npTrapInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.90
npTrapEmailTouser-specified e-mail for NetPing Trap Forwarding Servicero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.90.1
npReboot
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.911
npSoftRebootWrite 1 to reboot device after current operations completitionrw
INTEGER
.1.3.6.1.4.1.25728.911.1
npResetStackWrite 1 to re-initialize network stackrw
INTEGER
.1.3.6.1.4.1.25728.911.2
npForcedRebootWrite 1 to immediate forced rebootrw
INTEGER
.1.3.6.1.4.1.25728.911.3
npPwr
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.5800
npPwrTableWatchdog and outlet/relay control table
SEQUENCE OF NpPwrEntry
.1.3.6.1.4.1.25728.5800.3
npPwrEntryWatchdog and outlet/relay control table row
NpPwrEntry
.1.3.6.1.4.1.25728.5800.3.1
npPwrChannelNThe id of watchdog/power channelro
INTEGER
.1.3.6.1.4.1.25728.5800.3.1.1
npPwrStartResetWrite 1 to start reset On read: 0 - normal operation 1 - reset is active 2 - reboot pause is activerw
INTEGER
.1.3.6.1.4.1.25728.5800.3.1.2
npPwrManualModeMode of power channel 0 - manual off 1 - manual on 2 - watchdogrw
Enumeration
.1.3.6.1.4.1.25728.5800.3.1.3
npPwrResetsCounterCounter of watchdog resets Write 0 to clear.rw
INTEGER
.1.3.6.1.4.1.25728.5800.3.1.4
npPwrRepeatingResetsCounterCounter of continous failed watchdog resetsro
INTEGER
.1.3.6.1.4.1.25728.5800.3.1.5
npPwrMemoWatchdog/power channel memoro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.5800.3.1.6
npIr
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.7900
npIrCtrl
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.7900.1
npIrPlayCmdWrite IR command number to send IR commandrw
INTEGER
.1.3.6.1.4.1.25728.7900.1.1
npIrResetWrite 1 to reset IR transiever. After reset, send IR command and check npIrStatus.rw
INTEGER
.1.3.6.1.4.1.25728.7900.1.2
npIrStatusIR transiever statusro
Enumeration
.1.3.6.1.4.1.25728.7900.1.3
npCurLoop
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8300
npCurLoopTableCurrent loop sensors Table
SEQUENCE OF NpCurLoopEntry
.1.3.6.1.4.1.25728.8300.1
npCurLoopEntryCurrent loop sensors Table Row
NpCurLoopEntry
.1.3.6.1.4.1.25728.8300.1.1
npCurLoopNIndex of current loop, 1 to max supportedro
INTEGER
.1.3.6.1.4.1.25728.8300.1.1.1
npCurLoopStatusStatus of the loop 0=Normal, 1=Alert, 2=Cut, 3=Short, 4=Not Poweredro
Enumeration
.1.3.6.1.4.1.25728.8300.1.1.2
npCurLoopILoop current, mAro
INTEGER
.1.3.6.1.4.1.25728.8300.1.1.3
npCurLoopVVoltage drop on the loop, mVro
INTEGER
.1.3.6.1.4.1.25728.8300.1.1.4
npCurLoopRResistance of the loop, Ohmro
INTEGER
.1.3.6.1.4.1.25728.8300.1.1.5
npCurLoopPowerControl of loop power 0=Off, 1=On, 2=reset by off/on powerrw
Enumeration
.1.3.6.1.4.1.25728.8300.1.1.7
npCurLoopTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8300.2
npCurLoopTrapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8300.2.0
npCurLoopTrapStatus of current loop N has changed!
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8300.2.0.1
npCurLoopTrapNIndex of current loop, which status has changedro
INTEGER
.1.3.6.1.4.1.25728.8300.2.1
npCurLoopTrapStatusStatus of the loop 0=Normal, 1=Alert, 2=Cut, 3=Short, 4=Not Poweredro
Enumeration
.1.3.6.1.4.1.25728.8300.2.2
npCurLoopTrapILoop current, mAro
INTEGER
.1.3.6.1.4.1.25728.8300.2.3
npCurLoopTrapVVoltage drop on the loop, mVro
INTEGER
.1.3.6.1.4.1.25728.8300.2.4
npCurLoopTrapRResistance of the loop, Ohmro
INTEGER
.1.3.6.1.4.1.25728.8300.2.5
npCurLoopTrapPowerStatus of loop power 0=Off, 1=Onrw
Enumeration
.1.3.6.1.4.1.25728.8300.2.7
npRelHumidity
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8400
npRelHumSensor
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8400.2
npRelHumSensorValueHRelative humidity value, %ro
INTEGER
.1.3.6.1.4.1.25728.8400.2.2
npRelHumSensorStatusStatus of the Rel.Humidity Sensor One 0=Normal, 1=Error or Sensor isn't connectedro
Enumeration
.1.3.6.1.4.1.25728.8400.2.3
npRelHumSensorValueTSensor temperature, deg.Cro
INTEGER (-60..200)
.1.3.6.1.4.1.25728.8400.2.4
npRelHumSensorStatusHStatus of Relative Humidutyro
Enumeration
.1.3.6.1.4.1.25728.8400.2.5
npRelHumSafeRangeHighRelative Humidity safe range, top margin, %RHro
INTEGER
.1.3.6.1.4.1.25728.8400.2.7
npRelHumSafeRangeLowRelative Humidity safe range, bottom margin, %RHro
INTEGER
.1.3.6.1.4.1.25728.8400.2.8
npRelHumTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8400.9
npRelHumTrapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8400.9.0
npRelHumTrapStatus of Relative Humidity RH sensor has changed!
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8400.9.0.1
npThermo
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8800
npThermoTableThermo Sensors Table
SEQUENCE OF NpThermoEntry
.1.3.6.1.4.1.25728.8800.1
npThermoEntryThermo Sensors Table Row
NpThermoEntry
.1.3.6.1.4.1.25728.8800.1.1
npThermoSensorNThe id of temperature sensor, 1 to 8ro
INTEGER
.1.3.6.1.4.1.25728.8800.1.1.1
npThermoValueTemperature, deg.Cro
INTEGER (-60..280)
.1.3.6.1.4.1.25728.8800.1.1.2
npThermoStatusTemperature status (0=fault, 1=underheat, 2=normal, 3=overheat)ro
Enumeration
.1.3.6.1.4.1.25728.8800.1.1.3
npThermoLowBottom margin of normal temperature range, deg.Cro
INTEGER (-60..280)
.1.3.6.1.4.1.25728.8800.1.1.4
npThermoHighTop margin of normal temperature range, deg.Cro
INTEGER (-60..280)
.1.3.6.1.4.1.25728.8800.1.1.5
npThermoMemoT channel memoro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8800.1.1.6
npThermoTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8800.2
npThermoTrapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8800.2.0
npThermoTrapStatus of Thermo sensor is changed (crossing of normal temp. range)
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8800.2.0.1
npThermoTrapSensorNThe id of temperature sensor, 1 to 8ro
INTEGER
.1.3.6.1.4.1.25728.8800.2.1
npThermoTrapValueTemperature, deg.Cro
INTEGER (-60..280)
.1.3.6.1.4.1.25728.8800.2.2
npThermoTrapStatusTemperature status (0=fault, 1=underheat, 2=normal, 3=overheat)ro
Enumeration
.1.3.6.1.4.1.25728.8800.2.3
npThermoTrapLowBottom margin of normal temperature range, deg.Cro
INTEGER (-60..280)
.1.3.6.1.4.1.25728.8800.2.4
npThermoTrapHighTop margin of normal temperature range, deg.Cro
INTEGER (-60..280)
.1.3.6.1.4.1.25728.8800.2.5
npThermoTrapMemoT channel memoro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8800.2.6
npIo
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8900
npIoTableDigital Input/output Table
SEQUENCE OF NpIoEntry
.1.3.6.1.4.1.25728.8900.1
npIoEntryDigital Input/output Table Row
NpIoEntry
.1.3.6.1.4.1.25728.8900.1.1
npIoLineNNumber of IO line, from 1 to max supportedro
INTEGER
.1.3.6.1.4.1.25728.8900.1.1.1
npIoLevelInInput level, 0 or 1ro
INTEGER
.1.3.6.1.4.1.25728.8900.1.1.2
npIoLevelOutOutput level, 0 or 1rw
INTEGER
.1.3.6.1.4.1.25728.8900.1.1.3
npIoMemoIO line memoro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8900.1.1.6
npIoPulseCounterPulse Counter on IO input line (counts positive fronts) Write 0 to reset.rw
Counter32
.1.3.6.1.4.1.25728.8900.1.1.9
npIoSinglePulseDurationSet duration of single pulse on IO output line, 100ms to 25500ms, min. step is 100msrw
INTEGER
.1.3.6.1.4.1.25728.8900.1.1.12
npIoSinglePulseStartWrite 1 to start single pulse on IO output. Output will be inverted for time, specified by npIoSinglePulseDurationrw
INTEGER
.1.3.6.1.4.1.25728.8900.1.1.13
npIoTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8900.2
npIoTrapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8900.2.0
npIoTrapInput state of IO line is changed
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8900.2.0.1
npIoTrapLineNTrap data, Number of IO linero
INTEGER
.1.3.6.1.4.1.25728.8900.2.1
npIoTrapLevelInTrap data, new Input level, 0 or 1ro
INTEGER
.1.3.6.1.4.1.25728.8900.2.2
npIoTrapMemoTrap data, IO line memoro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8900.2.6
DKSF-50-11-X-X-X - SNMP MIB Reference | MIBs Explorer