Home/Catalog/DKSF-70-5-X-X-1

DKSF-70-5-X-X-1

Generic MIB for NetPing remote sensing and control
Main OID:
uniPingServerSolutionV3.1.3.6.1.4.1.25728.70
131
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

131 total
Object Name
lightcom
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728
uniPingServerSolutionV3Generic MIB for NetPing remote sensing and control
MODULE-IDENTITY
.1.3.6.1.4.1.25728.70
npTrapInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.90
npTrapEmailTouser-specified e-mail for NetPing Trap Forwarding Servicero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.90.1
npReboot
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.911
npSoftRebootWrite 1 to reboot device after current operations completitionrw
INTEGER
.1.3.6.1.4.1.25728.911.1
npResetStackWrite 1 to re-initialize network stackrw
INTEGER
.1.3.6.1.4.1.25728.911.2
npForcedRebootWrite 1 to immediate forced rebootrw
INTEGER
.1.3.6.1.4.1.25728.911.3
npGsm
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.3800
npGsmInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.3800.1
npGsmFailedFirmware's GSM module statusro
Enumeration
.1.3.6.1.4.1.25728.3800.1.1
npGsmRegistrationStatus of modem registration in GSM network (AT+CREG? result)ro
Enumeration
.1.3.6.1.4.1.25728.3800.1.2
npGsmStrengthGSM signal strength. 0..31 = 0..100%, 99 = unknown or n/a, 255 = updating inforo
INTEGER
.1.3.6.1.4.1.25728.3800.1.3
npGsmSendSmsSend arbitrary SMS. Format: [phone_number,phone_number,...] Message One to four destination phone numbers If [] and numbers omitted, mesagge will be sent to preset numbers from SMS setup Cyrillic characters must be in UTF8 encoding.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.3800.1.9
npGsmTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.3800.2
npGsmTrapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.3800.2.0
npGsmTrapGSM modem or SMS firmware problems
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.3800.2.0.1
npRelay
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.5500
npRelayTableWatchdog and outlet/relay control table
SEQUENCE OF NpRelayEntry
.1.3.6.1.4.1.25728.5500.5
npRelayEntryRelay/outlet table row
NpRelayEntry
.1.3.6.1.4.1.25728.5500.5.1
npRelayNThe N of output relayro
INTEGER
.1.3.6.1.4.1.25728.5500.5.1.1
npRelayModeControl of relay: -1 - flip between on(1) and off(0) 0 - manual off 1 - manual on 2 - watchdog 3 - schedule 4 - both schedule and watchdog (while switched on by schedule) 5 - logicrw
Enumeration
.1.3.6.1.4.1.25728.5500.5.1.2
npRelayStartResetWrite 1 to start reset (switch relay off for some time)rw
INTEGER
.1.3.6.1.4.1.25728.5500.5.1.3
npRelayMemoRelay memoro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.5500.5.1.6
npRelayStateActual relay state at the moment, regardless of source of control. 0 - relay is off 1 - relay is onro
Enumeration
.1.3.6.1.4.1.25728.5500.5.1.15
npIr
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.7900
npIrCtrl
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.7900.1
npIrPlayCmdWrite IR command number to send IR commandrw
INTEGER
.1.3.6.1.4.1.25728.7900.1.1
npIrResetWrite 1 to reset IR transiever. After reset, send IR command and check npIrStatus.rw
INTEGER
.1.3.6.1.4.1.25728.7900.1.2
npIrStatusIR transiever statusro
Enumeration
.1.3.6.1.4.1.25728.7900.1.3
npSmoke
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8200
npSmokeTableSmoke Sensors Table
SEQUENCE OF NpSmokeEntry
.1.3.6.1.4.1.25728.8200.1
npSmokeEntrySmoke Sensors Table Row
NpSmokeEntry
.1.3.6.1.4.1.25728.8200.1.1
npSmokeSensorNThe id of 1Wire Smoke sensor, 1 to 4ro
INTEGER
.1.3.6.1.4.1.25728.8200.1.1.1
npSmokeStatusStatus of Smoke sensorro
Enumeration
.1.3.6.1.4.1.25728.8200.1.1.2
npSmokePowerControls power on Smoke sensor current looprw
Enumeration
.1.3.6.1.4.1.25728.8200.1.1.3
npSmokeResetWrite 1 to switch off for approx. 10s to reset sensorrw
INTEGER
.1.3.6.1.4.1.25728.8200.1.1.4
npSmokeMemoSmoke sensor memoro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8200.1.1.6
npSmokeTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8200.2
npSmokeTrapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8200.2.0
npSmokeTrapStatus of 1W Smoke sensor has changed
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8200.2.0.1
npSmokeTrapSensorNThe id of 1Wire Smoke sensor, 1 to 4ro
INTEGER
.1.3.6.1.4.1.25728.8200.2.1
npSmokeTrapStatusNew status of Smoke sensorro
Enumeration
.1.3.6.1.4.1.25728.8200.2.2
npSmokeTrapMemoSmoke sensor memoro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8200.2.6
npCurLoop
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8300
npCurLoopTableCurrent loop sensors Table
SEQUENCE OF NpCurLoopEntry
.1.3.6.1.4.1.25728.8300.1
npCurLoopEntryCurrent loop sensors Table Row
NpCurLoopEntry
.1.3.6.1.4.1.25728.8300.1.1
npCurLoopNIndex of current loop, 1 to max supportedro
INTEGER
.1.3.6.1.4.1.25728.8300.1.1.1
npCurLoopStatusStatus of the loop 0=Normal, 1=Alert, 2=Cut, 3=Short, 4=Not Poweredro
Enumeration
.1.3.6.1.4.1.25728.8300.1.1.2
npCurLoopILoop current, mAro
INTEGER
.1.3.6.1.4.1.25728.8300.1.1.3
npCurLoopVVoltage drop on the loop, mVro
INTEGER
.1.3.6.1.4.1.25728.8300.1.1.4
npCurLoopRResistance of the loop, Ohmro
INTEGER
.1.3.6.1.4.1.25728.8300.1.1.5
npCurLoopPowerControl of loop power 0=Off, 1=On, 2=reset by off/on powerrw
Enumeration
.1.3.6.1.4.1.25728.8300.1.1.7
npCurLoopTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8300.2
npCurLoopTrapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8300.2.0
npCurLoopTrapStatus of current loop N has changed!
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8300.2.0.1
npCurLoopTrapNIndex of current loop, which status has changedro
INTEGER
.1.3.6.1.4.1.25728.8300.2.1
npCurLoopTrapStatusStatus of the loop 0=Normal, 1=Alert, 2=Cut, 3=Short, 4=Not Poweredro
Enumeration
.1.3.6.1.4.1.25728.8300.2.2
npCurLoopTrapILoop current, mAro
INTEGER
.1.3.6.1.4.1.25728.8300.2.3
npCurLoopTrapVVoltage drop on the loop, mVro
INTEGER
.1.3.6.1.4.1.25728.8300.2.4
npCurLoopTrapRResistance of the loop, Ohmro
INTEGER
.1.3.6.1.4.1.25728.8300.2.5
npCurLoopTrapPowerStatus of loop power 0=Off, 1=Onrw
Enumeration
.1.3.6.1.4.1.25728.8300.2.7
npRelHumidity
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8400
npRelHumTableHumidity+Temperature Sensors Table
SEQUENCE OF NpRelHumEntry
.1.3.6.1.4.1.25728.8400.1
npRelHumEntryHumidity+Temperature Sensors Table Row
NpRelHumEntry
.1.3.6.1.4.1.25728.8400.1.1
npRelHumNIndex of Humidity+Temperature sensor, 1 to max supportedro
INTEGER
.1.3.6.1.4.1.25728.8400.1.1.1
npRelHumValueRelative humidity value, %ro
INTEGER
.1.3.6.1.4.1.25728.8400.1.1.2
npRelHumStatusStatus of Relative Humidutyro
Enumeration
.1.3.6.1.4.1.25728.8400.1.1.3
npRelHumTempValueSensor temperature, deg.Cro
INTEGER (-60..200)
.1.3.6.1.4.1.25728.8400.1.1.4
npRelHumTempStatusStatus of Relative Humidutyro
Enumeration
.1.3.6.1.4.1.25728.8400.1.1.5
npRelHumMemoSensor Memo/Locationro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8400.1.1.6
npRelHumSafeRangeHighRelative Humidity safe range, top margin, %RHro
INTEGER
.1.3.6.1.4.1.25728.8400.1.1.7
npRelHumSafeRangeLowRelative Humidity safe range, bottom margin, %RHro
INTEGER
.1.3.6.1.4.1.25728.8400.1.1.8
npRelHumTempSafeRangeHighTemperature safe range, top margin, deg.Cro
INTEGER (-55..150)
.1.3.6.1.4.1.25728.8400.1.1.9
npRelHumTempSafeRangeLowTemperature safe range, bottom margin, deg.Cro
INTEGER (-55..150)
.1.3.6.1.4.1.25728.8400.1.1.10
npRelHumTrapData
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8400.3
npRelHumTrapDataNIndex of Humidity+Temperature sensor, 1 to max supportedro
INTEGER
.1.3.6.1.4.1.25728.8400.3.1
npRelHumTrapDataValueSensor humidity, %RH, or temperature, deg.Cro
INTEGER
.1.3.6.1.4.1.25728.8400.3.2
npRelHumTrapDataStatusStatus of humidity or temperaturero
Enumeration
.1.3.6.1.4.1.25728.8400.3.4
npRelHumTrapDataMemoSensor Memo/Locationro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8400.3.6
npRelHumTrapDataSafeRangeHighRelative Humidity safe range, top margin, %RH or deg.Cro
INTEGER
.1.3.6.1.4.1.25728.8400.3.7
npRelHumTrapDataSafeRangeLowRelative Humidity safe range, bottom margin, %RH or deg.Cro
INTEGER
.1.3.6.1.4.1.25728.8400.3.8
npRelHumTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8400.6
npRelHumTrapFailRel.Humidity sensor failed!
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8400.6.100
npRelHumTrapBelowSafeHumidity below the Safe range
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8400.6.101
npRelHumTrapSafeHumidity in the Safe range
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8400.6.102
npRelHumTrapAboveSafeHumidity above the Safe range
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8400.6.103
npRelHumTrapAllEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8400.6.127
npRelHumTrapAllChannelsStatus of Humidity has changed!
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8400.6.127.99
npRelHumTrapTemp
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8400.7
npRelHumTrapTempFailSensor failed!
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8400.7.100
npRelHumTrapTempBelowSafeTemperature below the Safe range
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8400.7.101
npRelHumTrapTempSafeTemperature in the Safe range
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8400.7.102
npRelHumTrapTempAboveSafeTemperature above the Safe range
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8400.7.103
npRelHumTrapTempAllEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8400.7.127
npRelHumTrapTempAllChannelsStatus of Temperature has changed!
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8400.7.127.99
npThermo
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8800
npThermoTableThermo Sensors Table
SEQUENCE OF NpThermoEntry
.1.3.6.1.4.1.25728.8800.1
npThermoEntryThermo Sensors Table Row
NpThermoEntry
.1.3.6.1.4.1.25728.8800.1.1
npThermoSensorNThe id of temperature sensor, 1 to 8ro
INTEGER
.1.3.6.1.4.1.25728.8800.1.1.1
npThermoValueTemperature, deg.Cro
INTEGER (-60..280)
.1.3.6.1.4.1.25728.8800.1.1.2
npThermoStatusTemperature status (0=fault, 1=underheat, 2=normal, 3=overheat)ro
Enumeration
.1.3.6.1.4.1.25728.8800.1.1.3
npThermoLowBottom margin of normal temperature range, deg.Cro
INTEGER (-60..280)
.1.3.6.1.4.1.25728.8800.1.1.4
npThermoHighTop margin of normal temperature range, deg.Cro
INTEGER (-60..280)
.1.3.6.1.4.1.25728.8800.1.1.5
npThermoMemoT channel memoro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8800.1.1.6
npThermoTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8800.2
npThermoTrapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8800.2.0
npThermoTrapStatus of Thermo sensor is changed (crossing of normal temp. range)
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8800.2.0.1
npThermoTrapSensorNThe id of temperature sensor, 1 to 8ro
INTEGER
.1.3.6.1.4.1.25728.8800.2.1
npThermoTrapValueTemperature, deg.Cro
INTEGER (-60..280)
.1.3.6.1.4.1.25728.8800.2.2
npThermoTrapStatusTemperature status (0=fault, 1=underheat, 2=normal, 3=overheat)ro
Enumeration
.1.3.6.1.4.1.25728.8800.2.3
npThermoTrapLowBottom margin of normal temperature range, deg.Cro
INTEGER (-60..280)
.1.3.6.1.4.1.25728.8800.2.4
npThermoTrapHighTop margin of normal temperature range, deg.Cro
INTEGER (-60..280)
.1.3.6.1.4.1.25728.8800.2.5
npThermoTrapMemoT channel memoro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8800.2.6
npIo
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8900
npIoTableDigital Input/output Table
SEQUENCE OF NpIoEntry
.1.3.6.1.4.1.25728.8900.1
npIoEntryDigital Input/output Table Row
NpIoEntry
.1.3.6.1.4.1.25728.8900.1.1
npIoLineNNumber of IO line, from 1 to max supportedro
INTEGER
.1.3.6.1.4.1.25728.8900.1.1.1
npIoLevelInInput level, 0 or 1ro
INTEGER
.1.3.6.1.4.1.25728.8900.1.1.2
npIoLevelOutOutput level, 0 or 1. Write -1 to flip output.rw
Enumeration
.1.3.6.1.4.1.25728.8900.1.1.3
npIoMemoIO line memoro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8900.1.1.6
npIoPulseCounterPulse Counter on IO input line (counts positive fronts) Write 0 to reset.rw
Counter32
.1.3.6.1.4.1.25728.8900.1.1.9
npIoSinglePulseDurationSet duration of single pulse on IO output line, 100ms to 25500ms, min. step is 100msrw
INTEGER
.1.3.6.1.4.1.25728.8900.1.1.12
npIoSinglePulseStartWrite 1 to start single pulse on IO output. Output will be inverted for time, specified by npIoSinglePulseDurationrw
INTEGER
.1.3.6.1.4.1.25728.8900.1.1.13
npIoTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8900.2
npIoTrapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.25728.8900.2.0
npIoTrapInput state of IO line is changed
NOTIFICATION-TYPE
.1.3.6.1.4.1.25728.8900.2.0.1
npIoTrapLineNTrap data, Number of IO linero
INTEGER
.1.3.6.1.4.1.25728.8900.2.1
npIoTrapLevelInTrap data, new Input level, 0 or 1ro
INTEGER
.1.3.6.1.4.1.25728.8900.2.2
npIoTrapMemoTrap data, IO line memoro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8900.2.6
npIoTrapLevelLegendLegend for current logic level on the IO linero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.25728.8900.2.7