Home/Catalog/CXV34-MIB

CXV34-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

18
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

18 total
Object Name
IMPORTSDescribes a table that contains configuration information about each V34 modem and its associated hardware port.
SEQUENCE OF V34SlotEntry
.1.3.6.1.4.1.495.2.1.6.42.1
v34SlotEntryDescribes the configuration information applied to a specific V34 modem and its associated hardware port.
V34SlotEntry
.v34SlotTable.1
v34SlotNumberIdentifies a numerical value applied to the modem. Each device has a unique number.ro
SapIndex
.v34SlotTable.1.1
v34SlotAliasAssigns a name used for the alias. Each modem requires a unique name. You may not assign the same name twice. Default Value: none Range of Values: Up to twelve alphanumeric characters, the first character must be alphabetic. Configuration Changed: operativerw
Alias
.v34SlotTable.1.2
v34SlotRowStatusDetermines the status of the objects in in a table row. Default Value: none Options: invalid (1): row is flagged, after next reset the values will be disabled and the row will be deleted from the table. valid (2): values are enabled Configuration Changed: administrativerw
Enumeration
.v34SlotTable.1.3
v34SlotStatusIdentifies the presence or absence of a V.34 modem in the slot and if present, whether it has failed initialization. Default Value: none Options: v34-not-present (1) v34-present (2) v34-present-failed (3)ro
Enumeration
.v34SlotTable.1.4
v34SlotModemStringDetermines a string to be sent to the modem upon initialization. Default Value: none Range of Values: 0-32 alphanumberic characters Configuration Changed: administrativerw
DisplayString
.v34SlotTable.1.5
v34SlotDialNumberSpecifies the number used to dial the remote modem. Default Value: none Range of Values: An octet string of 12 numeric characters Configuration Changed: administrativerw
DisplayString
.v34SlotTable.1.6
v34SlotAnswerModeDetermines whether the device will answer an incoming call. Default Value: answer-enabled (2) Options: answer-disabled (1) answer-enabled (2) test-mode (3) Configuration Changed: operativerw
Enumeration
.v34SlotTable.1.7
v34SlotSpeedStatusIdentifies the connection rate operative during the current dial call only. Default Value: none Options: speed-0-300 (1) speed-600 (2) speed-1200 (3) speed-2400 (4) speed-4800 (5) speed-7200 (6) speed-9600 (7) speed-12000 (8) speed-14400 (9) speed-16800 (10) speed-19200 (11) speed-21600 (12) speed-24000 (13) speed-26400 (14) speed-28800 (15)ro
Enumeration
.v34SlotTable.1.8
v34SlotRetrainStatusIdentifies whether the modem is retraining or not. It is only applicable while the modem is on-line. Default Value: none Options: no-retraining (1) retraining (2)ro
Enumeration
.v34SlotTable.1.9
v34SlotHookStatusIdentifies whether the modem is 'off-hook' (connected to the telephone line), or 'on-hook' (disconnected). Default Value: none Options: on-hook (1) off-hook (2)ro
Enumeration
.v34SlotTable.1.10
v34SlotRingStatusIdentifies when the modem detects a ring signal from the telephone line. Default Value: none Options: no-ring (1) ring (2)ro
Enumeration
.v34SlotTable.1.11
v34SlotDsrStatusIdentifies the data transfer state of the modem by the status of the Data Set Ready (DSR) signal . Default Value: none Options dsr-deasserted (1): data transfer inactive dsr-asserted (2): data transfer activero
Enumeration
.v34SlotTable.1.12
v34SlotDtrStatusIdentifies the status of the Data Terminal Ready (DTR) signal that the motherboard uses to dial the pre-stored phone number (if in originate mode) or to enable auto answer (if in answer mode). Default Value: none Options: dtr-deasserted (1) dtr-asserted (2)ro
Enumeration
.v34SlotTable.1.13
v34SlotModelIdentifies the model number of the Printed Circuit Board (PCB) as an integer value from 0 to 7. Default Value: none Range of Values: 0-7ro
INTEGER
.v34SlotTable.1.14
v34SlotRevisionIdentifies the revision number of the PCB as an integer value from 0 to 15. Default Value: none Range of Values: 0-15ro
INTEGER
.v34SlotTable.1.15
v34SlotEcoIdentifies the Engineering Change Order (ECO) level of the PCB as an integer value from 0 to 15. Default Value: none Range of Values: 0-15ro
INTEGER
.v34SlotTable.1.16
CXV34-MIB - SNMP MIB Reference | MIBs Explorer