CXAsync-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for CXAsync-MIB.
135
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
135 total| Object Name |
|---|
asySapAlarmIndicates that the global object asyStatusEvent has occurred at the
identified SAP (service access point) if the global object asyAlarms is enabled. TRAP-TYPE .1.3.6.1.4.1.495.2.1.6.30.0.1 |
RFC1155-SMIDefines the global X.25 queue
threshold, in number of frames.
When the threshold is exceeded and the SAP (service access point) object
asySapNetworkFlowControlState is in the Flow Control On state, a Disconnect
Request, for SVC (switch virtual circuits), or a Reset Request, for PVC
(permanent virtual circuits), takes place at the X.25 layer.
Range of Values: 1 - 255
Default Value: 10
Configuration Changed: Administrativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.1 |
asyPadIdBannerDefines the Async PAD Identification Banner. This banner is transmitted to the attached
device whenever it raises interface signals.
Range of Values: 1 - 255
Default Value:
Async PAD
Configuration Changed: Operativerw DisplayString .1.3.6.1.4.1.495.2.1.6.30.2 |
asyAlarmsIndicates whether this layer produces the object asySapAlarm trap.
Options:
disabled (1)
enable (2)
Default Value: disable
Configuration Changed: Administrativerw Enumeration .1.3.6.1.4.1.495.2.1.6.30.7 |
asySapStatusEventIdentifies the status generated in the object asyAlarmTrap.
This object is used for identification by the trap when it occurs and will
always return the value noEvent when read.ro Enumeration .1.3.6.1.4.1.495.2.1.6.30.8 |
asySoftwareVersionsIdentifies the revision numbers of the Async layer software.
This is a read-only parameter that displays the revision number as a string
of five numbers. Each number is separated by a period and is identified
as follows:
1. main version number
2. main revision number
3. branch version number
4. branch revision number
5. part numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.495.2.1.6.30.9 |
asyMibLevelUsed to determine current MIB module release supported
by the agent. Object is in decimal.ro INTEGER .1.3.6.1.4.1.495.2.1.6.30.10 |
asySapTableContains configuration information about each Async layer SAP (service
access point). SEQUENCE OF AsySapEntry .1.3.6.1.4.1.495.2.1.6.30.20 |
asySapEntryContains the parameters for a specific Async layer SAP (service access point). AsySapEntry .1.3.6.1.4.1.495.2.1.6.30.20.1 |
asySapNumberIndicates the table row containing configuration or monitoring objects for
a SAP (service access point) associated with the slot of a card, a port of this
card, and a logical channel on this port.
Range of Values: 11x to 71x
Note: First number is the slot, second number is the port, and x is the
logical channel.
Default Value: Nonero SapIndex .1.3.6.1.4.1.495.2.1.6.30.20.1.1 |
asySapRowStatusIndicates whether or not this specific entry is configured within the MIB.
Options:
invalid (1): Row is flagged and deleted from the table after the next reset.
valid (2): Parameter is added or modified if it already exists in the table.
Default Value: valid
Configuration Changed: Operative for valid entry and administrative for
invalid entryrw Enumeration .1.3.6.1.4.1.495.2.1.6.30.20.1.2 |
asySapAliasDetermines the name which uniquely identifies the SAP (service access
point).
Range of Values: 1 to 16 alphanumeric characters beginning with an
alpha character
Default Value: none
Configuration Changed: Administrativerw Alias .1.3.6.1.4.1.495.2.1.6.30.20.1.3 |
asySapMCompanionAliasDetermines the name which uniquely identifies the companion MAC SAP
(service access point) which will communicate with this SAP.
Range of Values: 1 to 16 alphanumeric characters beginning with an
alpha character
Default Value: none
Changed: Administrativerw Alias .1.3.6.1.4.1.495.2.1.6.30.20.1.4 |
asySapNCompanionAliasDetermines the name which uniquely identifies the X.25 SAP (service access
point) which will communicate with this SAP.
Range of Values: 1 to 16 alphanumeric characters beginning with an
alpha character
Default Value: none
Configuration Changed: Administrativerw Alias .1.3.6.1.4.1.495.2.1.6.30.20.1.5 |
asySapX3ProfileTells the SAP (service access point) which set of X.3 parameters to use.
Range of Values: 1 - 255
Default Value: 92
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.20.1.6 |
asySapNUIDefines the Network User ID for this SAP (service access point).
Options: 1 to 14 alphanumeric characters
Default Value: 0
Configuration Changed: Operativerw DisplayString .1.3.6.1.4.1.495.2.1.6.30.20.1.7 |
asySapAddressDefines the calling address for this SAP (service access point).
Range of Values: 1 to 15 digits
Default Value: 0
Configuration Changed: Operativerw DisplayString .1.3.6.1.4.1.495.2.1.6.30.20.1.8 |
asySapDisconnectRequestSends a Disconnect Request to the MAC layer when the YT timer expires.
Options:
Yes = Enable the disconnect request
No = Disable the disconnect request
Default Value: No
Configuration Changed: Operativerw YesNo .1.3.6.1.4.1.495.2.1.6.30.20.1.9 |
asySapRxThruputClassDefines the default receive throughput class that is used at this SAP (service
access point).
Range of Values: 75 - 64000 bps
Default Value: 9600 bps
Configuration Changed: Operativerw ThruputClass .1.3.6.1.4.1.495.2.1.6.30.20.1.10 |
asySapTxThruputClassDefines the default transmit throughput class that is used at this SAP
(service access point).
Range of Values: 75 to 64000 bps
Default Value: 9600 bps
Configuration Changed: Operativerw ThruputClass .1.3.6.1.4.1.495.2.1.6.30.20.1.11 |
asySapTxPacketSizeDefines the size of the transmit packet for the Async layer.
Range of Values: 16 to 4096 bytes
Default Value: 128 bytes
Configuration Changed: Operativerw PacketSize .1.3.6.1.4.1.495.2.1.6.30.20.1.12 |
asySapRxPacketSizeDefines the size of the receive packet for the Async layer.
Range of Values: 16 to 4096 bytes
Default Value: 128 bytes
Configuration Changed: Operativerw PacketSize .1.3.6.1.4.1.495.2.1.6.30.20.1.13 |
asySapTxWindowSizeDefines the size of the transmit window for the Async layer.
Range of Values: 1 to 127
Default Value: 2
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.20.1.14 |
asySapRxWindowSizeDefines the size of the receive window for the Async layer.
Range of Values: 1 to 127
Default Value: 2
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.20.1.15 |
asySapYTTimerDefines the time of inactivity, in seconds, after which the SAP (service
access point) will send a disconnect request to the MAC layer. The timer
starts when the line is enabled or the virtual circuit is cleared and stops
when the first character of a command is entered.
Range of Values: 0 to 255
Note: A value of 0 means that the timer is disabled.
Default Value: 60
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.20.1.16 |
asySapSRTimerDefines the time of inactivity, in seconds, between command characters.
The timer starts when the command mode is entered or when a character of a
command is entered and stops when a command is entered or when data mode is
entered. A time-out will generate an error message.
Range of Values: 0 to 255
Note: A value of 0 means that the timer is disabled.
Default Value: 60
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.20.1.17 |
asySapNUILengthDefines the length, in nibbles, allowed for the Network User ID.
Range of Values: 1 to 14
Default Value: 0
Configuration Changed: Operativerwobsolete INTEGER .1.3.6.1.4.1.495.2.1.6.30.20.1.18 |
asySapReverseChargingAcceptanceAuthorizes the DCE (Async application) to transmit incoming calls to the DTE
(Async user) that requested the reverse charging, if reverse charging acceptance
is allowed. If acceptance is not allowed, the DCE (Async application)
will not transmit the incoming calls to the DTE which requested the reverse
charging.
Options:
Yes
No
Default Value: No
Configuration Changed: Operativerw YesNo .1.3.6.1.4.1.495.2.1.6.30.20.1.19 |
asySapChargingInformationAuthorizes the DCE (Async application) to send charging information to the DTE
(user) with the Clear Indication or Clear Confirmation packet.
Options:
Yes
No
Default Value: No
Configuration Changed: Operativerw YesNo .1.3.6.1.4.1.495.2.1.6.30.20.1.20 |
asySapSubscriptionCUGEnables the DTE (User) to subscribe to one or more CUGs (Closed User Groups).
A CUG permits the DTEs belonging to the group to communicate with each other in
the group but prevents communication with all other DTEs.
Options:
Yes
No
Default Value: No
Configuration Changed: Operativerw YesNo .1.3.6.1.4.1.495.2.1.6.30.20.1.21 |
asySapSubscriptionCUGOAEnables the DTE (user) to subscribe to one or more CUGs (Closed User Groups),
as in object asySapSubscriptionCUG, with outgoing access.
The DTE can originate virtual calls to DTEs in the open part of the network
(DTEs not belonging to a CUG), and to DTEs belonging to other CUGs with
incoming access capability.
Options:
Yes
No
Default Value: No
Configuration Changed: Operativerw YesNo .1.3.6.1.4.1.495.2.1.6.30.20.1.22 |
asySapSubscriptionCUGIAEnables the DTE (user) to subscribe to one or more CUGs (Closed User Groups),
as in object asySapSubscriptionCUG, with incoming access.
The DTE can receive incoming calls from DTEs in the open part of the network
(DTEs not belonging to a CUG), and from DTEs belonging to other CUGs with
outgoing access capability.
Options:
Yes
No
Default Value: No
Configuration Changed: Operativerw YesNo .1.3.6.1.4.1.495.2.1.6.30.20.1.23 |
asySapPreferentialCUGIndexDefines the preferential CUG (Closed
User Group) for a DTE (user) with a CUG,
CUGOA or CUGIA subscription.
Range of Values: 0 to 99
Note: 0 = No preferential CUG, 1 to 99 = Basic format values allowed
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.20.1.24 |
asySapReceiptConfirmationTells the X.25 layer which receipt confirmation value is required by this
SAP (service access point).
Options:
noAck
dBit
localAck
xmitAck
Default Value: noAck
Configuration Changed: Operativerw Enumeration .1.3.6.1.4.1.495.2.1.6.30.20.1.25 |
asySapEnableProtocolIdControls whether or not the Protocol ID field of the user data is inserted by
the Async layer.
Options:
enable = Allows up to 12 bytes, or 124 bytes for fast select, of user data for
the X.28 value command where the Protocol ID field of the user data is
inserted by the Async layer
disable = Allows up to 16 bytes, or 128 bytes for fast select, of user data for
the X.28 value command where the Protocol ID field of the user data is
not inserted by the Async layer)
Default Value: enable
Configuration Changed: Operativerw YesNo .1.3.6.1.4.1.495.2.1.6.30.20.1.26 |
asySapProtocolIdDefines the protocol format that is used for incoming call or call request
packets to the X.25 call data field.
The field consists of 4 hexadecimal octets where the first octet is coded as
follows:
bits 8 & 7
- 00 for CCITT use
- 01 for national use
- 10 reserved for international user bodies
- 11 for DTE-DTE use
When bits 8 & 7 are equal to 00, bits 6 to 1 will be equal to 000001. The first
octet is shown as 01, 00, 00, 00. The first 0 in each number is optional and
may be shown as 1, 0, 0, 0.
All bits of octets 2, 3 and 4 are set to 0. They are reserved as a future
mechanism for providing the called PAD or packet mode DTE (user) with
additional information pertaining to the calling party.
Default Value: 01,00,00,00
Configuration Changed: Operativerw DisplayString .1.3.6.1.4.1.495.2.1.6.30.20.1.27 |
asySapPromptSignalDefines the prompt PAD service signal (banner) that is sent to the MAC layer
whenever the Async PAD enters a PAD waiting state or waiting for command state.
Options: 1 to 16 alphanumeric characters
Default Value: Character 2/10 (*)
Configuration Changed: Operativerw DisplayString .1.3.6.1.4.1.495.2.1.6.30.20.1.28 |
asySapAutoConnectDteIdIdentifies the remote DTE (by name) to be connected to whenever the async
sap receives a Connect Indication or Connect Confirm from the MAC layer.
If no name is identified the Auto Connect is disabled for this saprw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.495.2.1.6.30.20.1.29 |
asySapAutoConnectRetryDefines the number of times this async sap will try to connect (if Connect
Accept is not received from the X.25 layer) to the remote DTE defined by the
object asySapAutoConnectDteId whenever the async sap receives a Connect
Indication or Connect Confirm from the MAC layer. The async sap will wait
the asySapAutoConnectDelayTimer before trying to connect. a value of '0'
means continuous retries.rw INTEGER .1.3.6.1.4.1.495.2.1.6.30.20.1.30 |
asySapAutoConnectDelayTimerDefines the time in seconds this async sap will wait before trying to
connect to the remote DTE defined by the object asySapAutoConnectDteId
whenever the async sap receives a Connect Indication or Connect Confirm
from the MAC layer.rw INTEGER .1.3.6.1.4.1.495.2.1.6.30.20.1.31 |
asySapHardwareFlowControlEnables the MAC to flow control the device via the EIA RTS/CTS signal.
Options:
Yes
No
Default Value: No
Configuration Changed: Operativerw YesNo .1.3.6.1.4.1.495.2.1.6.30.20.1.32 |
asySapProtocolTypeDefines the Async Protocol type for this sap.
Options:
normal (1) for Normal Async (X.3, X.28, X.29) protocol.
iocProtocol (2) for IOC Protocol.
ModifiedUDF (3) for the Modified IOC Protocol.
Default Value: 1
Configuration Changed: Operativerw Enumeration .1.3.6.1.4.1.495.2.1.6.30.20.1.33 |
asySapControlDefines the control that is used with
the specified Async layer SAP (service
access point).
Options:
clearStats (1): Zeros all the statistic counters for this SAP.
enableSAP (2): Enables the transmission and reception of data to and from the
SAP.
disableSAPImmediately (3): Disables the transmission and reception of data to
and from the SAP and any open virtual calls are cleared immediately.
disableSAPGracefully (4): Disables the transmission and reception of data to
and from SAP after the virtual call has been cleared by the X.28 or network
layer interface.
Configuration Changed: Operativerw Enumeration .1.3.6.1.4.1.495.2.1.6.30.20.1.37 |
asySapStateIndicates the current state of the Async layer SAP(service access point).
Options:
disconnected (1)
enabled (2)
connecting (3)
data Transfer (4)
resetting (5)
Default Value Nonero Enumeration .1.3.6.1.4.1.495.2.1.6.30.20.1.40 |
asySapAsyncFlowControlStateIndicates whether this SAP (service access point) was forced to initiate
flow control procedures by the MAC (media access control) layer.
Options:
flowControlOff (1)
flowControlOn (2)
Note:
When flow control is forced at this SAP, this object takes on the value,
flowControlOn.
Default Value: flowControlOffro Enumeration .1.3.6.1.4.1.495.2.1.6.30.20.1.41 |
asySapNetworkFlowControlStateIndicates whether or not this SAP (service access point) was forced to
initiate flow control procedures by the network layer.
Options:
flowControlOff (1)
flowControlON (2)
Note: When flow control is forced at this SAP, this object takes on the value,
flowControlOn.ro Enumeration .1.3.6.1.4.1.495.2.1.6.30.20.1.42 |
asySapAsyncTxQueueSizeIndicates the current number of frames to be transmitted to the MAC (media
access control) layer.ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.43 |
asySapX25TxQueueSizeIndicates the current number of frames to be send to the network layer.ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.44 |
asySapNumberConnectsIndicates the number of call attempts by this SAP (service access point).ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.50 |
asySapNumberDisconnectsIndicates the number of disconnects for this SAP (service access point).ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.51 |
asySapTxDataCharactersIndicates the number of data characters that were transmitted from this SAP
(service access point) to the MAC layer.ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.52 |
asySapRxDataCharactersIndicates the number of data characters that were received at this SAP (service
access point) from the MAC layer.ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.53 |
asySapParityErrorsIndicates the number of characters with parity errors that were received at this
SAP (service access point).ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.54 |
asySapOverrunsIndicates the number of characters with overrun errors that were received at
this SAP (service access point).ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.55 |
asySapFlowControlByUserIndicates the number of flow control characters that were received by this
SAP (service access point) from the Async port.ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.56 |
asySapFlowControlByX25Indicates the number of flow control messages that were received by this SAP
(service access point) from the network layer.ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.57 |
asySapFlowControlToUserIndicates the number of flow control characters that were transmitted by this
SAP (service access point) to the Async port.ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.58 |
asySapFlowControlToX25Indicates the number of flow control messages that were sent by this SAP
(service access point) to the network layer.ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.59 |
asySapRxResetIndicates the number of resets that were received at this SAP (service
access point) from the network layer.ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.60 |
asySapRxBreakIndicates the number of breaks that were received at this SAP (service
access point).ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.61 |
asySapTxBreakIndicates the number of breaks that were transmitted from this SAP (service
access point).ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.62 |
asySapRxDiscardCharactersIndicates the number of discard characters that were received at this SAP (service
access point).ro Counter .1.3.6.1.4.1.495.2.1.6.30.20.1.63 |
asyProfTableContains the X.3 parameters for each defined X.3 profile. SEQUENCE OF AsyProfEntry .1.3.6.1.4.1.495.2.1.6.30.21 |
asyProfEntryProvides the parameters for a specific X.3 profile SAP (service access point). AsyProfEntry .1.3.6.1.4.1.495.2.1.6.30.21.1 |
asyProfNumberIdentifies the profile SAP (service access point) using a unique numerical value.ro ProfIndex .1.3.6.1.4.1.495.2.1.6.30.21.1.1 |
asyProfRowStatusIndicates whether or not this specific entry is configured within the MIB.
Options:
invalid (1): Row is flagged and deleted from the table after the next reset
valid (1): Parameter is added or modified if it already exists in the table
Default Value: validrw Enumeration .1.3.6.1.4.1.495.2.1.6.30.21.1.2 |
asyProfAliasIdentifies the SAP (service access point) using a unique textual name.
Range of Values: 1 to 16 alphanumeric characters beginning with an
alpha character
Default Value: 0
Configuration Changed: Administrativerw Alias .1.3.6.1.4.1.495.2.1.6.30.21.1.3 |
asyProfParameter1Defines the X.3 parameter 1, PAD recall using a character. This parameter
allows the start-stop mode DTE (user) to initiate an escape from the data
transfer or the connection in progress state in order to send PAD command
signals.
Range of Values:
0 = Not possible
1 = Character DLE
32 to 126 = Graphic character defined by user
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.5 |
asyProfParameter2Defines the X.3 parameter 2, Echo. This parameter provides for characters
received from the start-stop mode DTE (user) to be transmitted back to the
start-stop mode DTE as well as being interpreted by the PAD.
Options:
0 = No echo
1 = Echo
Default Value: No echo
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.6 |
asyProfParameter3Defines the X.3 parameter 3, Selection of data forwarding character(s). This
parameter allows the selection of defined sets of characters received from
the start-stop mode DTE (user) to be recognized by the PAD as an indication
to complete the assembly and forward a complete packet
Range of Values:
0: No data forwarding character(s)
1: Alphanumeric characters (A-Z, a-z and 0-9)
2: Character CR
4: Characters ESC, BEL, ENQ and ACK
6: Characters CR, ESC, BEL, ENQ and ACK
8: Characters DEL, CAN and DC2
16: Characters ETX and EOT
18: Characters CR, ETX and EOT
32: Characters HT, LF, VT and FF
64: All characters in columns 0 and 1 of IA5 except those shown for
values 2, 4, 8 and 32
126: All characters in columns 0 and 1 and character DEL
Note: Some values are combinations of other values (i.e., value 18 is
a combination of values 2 and 16).
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.7 |
asyProfParameter4Defines the X.3 parameter 4, Selection of idle timer delay, in tenths of a
second. This parameter allows the selection of the duration of an interval
between successive characters received from the start-stop mode DTE (user).
When the interval is exceeded, the PAD terminates the assembly of the packet
and forwards it.
Range of Values: 0 to 255
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.8 |
asyProfParameter5Defines the X.3 parameter 5, Ancillary device control. This parameter allows
for flow control between the PAD and the start-stop mode DTE (user).
Options:
0: No use of X-ON (DC1) and X-OFF (DC3)
1: Use of X-ON and X-OFF (data transfer)
2: Use of X-ON and X-OFF (data transfer and command).
Default Value: No use of X-ON (DC1) and X-OFF (DC3)
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.9 |
asyProfParameter6Defines the X.3 parameter 6, Control of PAD service signals and PAD command
signals. This parameter provides the start-stop mode DTE (user) with the
ability to decide whether or not and in what format PAD service signals are
transmitted
Range of Values:
0: No PAD service signals are transmitted to the start-stop mode DTE
1: PAD service signals are transmitted in the standard format
5: PAD service signals and prompt PAD service signal are transmitted in the
standard format
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.10 |
asyProfParameter7Defines the X.3 parameter 7, Selection of operation of the PAD on receipt of a
break signal from the start-stop mode DTE. This parameter allows the
selection of the operation of the PAD after the receipt of a break signal
from the start-stop mode DTE (user).
Range of Values:
0: Nothing
1: Interrupt
2: Reset
4: Send to DTE an indication of break PAD message
5: Interrupt and indication of break
8: Escape from data transfer state
16: Discard output, to start-stop mode DTE
21: Discard output, interrupt and indication of break
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.11 |
asyProfParameter8Defines the X.3 parameter 8, Discard output. This parameter provides for a
PAD to discard the content of user sequences in packets upon request rather
than disassembling and transmitting these to the start-stop mode DTE (user).
Options:
0: Normal data delivery
1: Discard output
Default Value: Normal data delivery
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.12 |
asyProfParameter9Defines the X.3 parameter 9, Padding after carriage return (CR). This
parameter provides for the automatic insertion of padding characters by the
PAD after a carriage return by the DTE (user). This allows the printer of the
DTE to perform the carriage return function correctly.
Range of Values: 0 to 255
Note:
0: No padding after CR
1 to 255: Number of padding characters inserted after CR
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.13 |
asyProfParameter10Defines the X.3 parameter 10, Line folding. This parameter provides for
the automatic insertion of graphic characters by the PAD in the character
stream transmitted to the start-stop mode DTE (user). The predetermined
maximum number of graphic characters per line may be set.
Range of Values: 0 to 255
0: No line folding
1 to 255: Number of graphic characters per line
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.14 |
asyProfParameter11Defines the X.3 parameter 11, Binary
speed of start-stop mode DTE.
Options:
0: 110 bit/s
1: 134.5 bit/s
2: 300 bit/s
3: 1200 bit/s
4: 600 bit/s
5: 75 bit/s
6: 150 bit/s
7: 1800 bit/s
8: 200 bit/s
9: 100 bit/s
10: 50 bit/s
11: 75/1200 bit/s (not supported)
12: 2400 bit/s
13: 4800 bit/s
14: 9600 bit/s
15: 19200 bit/s
16: 48000 bit/s
17: 56000 bit/s
18: 64000 bit/s
19: 14400 bit/s
20: 38400 bit/s
21: 57600 bit/s
22: 115200 bit/s
255: non standard bit rate
Default Value: 110 bit/sro INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.15 |
asyProfParameter12Defines the X.3 parameter 12, Flow control of the PAD. This parameter
allows for flow control between the start-stop mode DTE (user) and the PAD.
Options:
0: No use of X-ON (DC1) and X-OFF (DC3) for flow control
1: Use of X-ON (DC1) and X-OFF (DC3) for flow control
Default Value: No use of X-ON (DC1) and X-OFF (DC3) for flow control
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.16 |
asyProfParameter13Defines the X.3 parameter 13, Linefeed insertion after carriage return. This
parameter allows for the automatic insertion of a linefeed character in the
character stream to and from the start-stop DTE (user) or after each carriage
return. This parameter applies only in the data transfer state.
Range of Values:
0: No linefeed insertion
1: Insert linefeed after transmission of CR to the start-stop mode DTE
2: Insert linefeed after each CR in the data stream from the start-stop mode DTE
4: Insert linefeed after echo of CR to start-stop mode DTE
5: Insert linefeed after transmission to the start-stop mode DTE and
after echo of CR
6:Insert linefeed in data stream after CR from start-stop mode DTE
and after an echo of a CR to the start-stop mode DTE
7: Insert linefeed in the data stream to and from the start-stop mode
DTE and after an echo of a CR to the start-stop mode DTE
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.17 |
asyProfParameter14Defines the X.3 parameter 14, Padding after linefeed. This parameter provides
for the automatic insertion of padding characters in the character stream
transmitted to the start-stop mode DTE (user) after the occurrence of a
linefeed character. This allows the printer of the DTE to perform the
linefeed operation correctly. This parameter applies only in the data
transfer state.
Range of Values:0 to 7
Note:
0: No padding after linefeed
1 to 7: Number of padding characters inserted after linefeed
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.18 |
asyProfParameter15Defines the X.3 parameter 15, Editing. This parameter provides for character
size delete, line delete and line display editing capabilities in the PAD
command state and the data transfer state for the start-stop mode DTE (user).
Options:
0: No use of editing in the data transfer state
1: Use of editing in the data transfer state
Default Value: No editing
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.19 |
asyProfParameter16Defines the X.3 parameter 16, Character delete.
Range of Values: 0 to 127
0 to126: One character from IA5
127: Character 7/15 (DEL)
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.20 |
asyProfParameter17Defines the X.3 parameter 17, Line delete.
Range of Values: 0 to 127
0 to 23: One character from the range of IA5
24: Character 1/8 (CAN)
25 to 127: One character from the range of IA5
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.21 |
asyProfParameter18Defines the X.3 parameter 18, Line display.
Range of Values: 0 to 127
0 to 17: One character from the range of IA5
18: Character 1/8 (DC2)
19 to 127: One character from the range of IA5
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.22 |
asyProfParameter19Defines the X.3 parameter 19, Editing PAD service signals. This parameter
provides the start-stop mode DTE (user) with the ability to decide whether or
not editing PAD service signals are transmitted and which format should be used.
Range of Values:
0: No editing PAD service signals
1: Editing PAD service signals for printing terminals
2: Editing PAD service signals for display terminals
8, 32 to 126: Editing PAD service signals using one character from the range of IA5
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.23 |
asyProfParameter20Defines the X.3 parameter 20, Echo mask. This parameter allows selected
defined sets of characters received from the start-stop mode DTE (user) not to be
transmitted back to the DTE.
Range of Values:
0: No echo mask (all characters echoed).
1: No echo of CR.
2: No echo of LF.
4: No echo of VT, HT and FF.
8: No echo of BEL and BS.
16: No echo of ESC and ENQ.
32: No echo of ACK, NAK, STX, SOH, EOT, ETB and ETX.
64: No echo of editing characters as designated by parameters 16, 17 and 18.
128: No echo of all other characters in columns 0 and 1 not mentioned
above and DEL.
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.24 |
asyProfParameter21Defines the X.3 parameter 21, Parity treatment. This parameter allows the
PAD to check parity in the data stream from the start-stop mode DTE (user) or
generate parity in the data stream to the DTE.
Options:
0: No parity checking or generation
1: Parity checking
2: Parity generation
3: Parity checking and parity generation
Default Value: No parity checking or generation
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.25 |
asyProfParameter22Defines the X.3 parameter 22, Page wait. This parameter allows the PAD to
suspend transmission of additional characters to the start-stop mode DTE
(user) after a specified number of linefeed characters have been
transmitted by the PAD.
Range of Values: 0 to 255
0: Page wait disable.
1 to 255: Number of line feed characters considered by the PAD for the
page wait function.
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.26 |
asyProfParameter23Defines parameter 23 (extension to X.3), Receive parity type.
Options:
0: Parity disable
1: Even parity
2: Odd parity
3: Space parity
4: Mark parity
Default Value: Parity disable
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.27 |
asyProfParameter24Defines parameter 24 (extension to
X.3), Transmit parity type.
Options:
0: Parity disable
1: Even parity
2: Odd parity
3: Space parity
4: Mark parity
Default Value: Parity disable
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.28 |
asyProfParameter25Defines parameter 25 (extension to X.3), Flow control on character to PAD.
Range of Values: 0 to 127
Note:
0 to 18: One character from the range of IA5
19: DC3
20 to 127: One character from the range of IA5
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.29 |
asyProfParameter26Defines parameter 26 (extension to X.3), Flow control off character to PAD.
Range of Values: 0 to 127
0 to 16: One character from the range of IA5
17: DC1
18 to 127: One character from the range of IA5
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.30 |
asyProfParameter27Defines parameter 27 (extension to X.3), Flow control on character to
ancillary device.
Range of Values: 0 to 127
Note:
0 to 18: One character from the range of IA5
19: DC3
20 to 127: One character from the range of IA5
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.31 |
asyProfParameter28Defines parameter 28 (extension to X.3), Flow control off character to
ancillary device.
Range of Values: 0 to 127
0 to 16: One character from the range of IA5
17: DC1
18 to 127: One character from the range of IA5
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.21.1.32 |
asySapProfTableContains the operational X.3 parameters for each async SAP (service access point). SEQUENCE OF AsySapProfEntry .1.3.6.1.4.1.495.2.1.6.30.22 |
asySapProfEntryProvides the operational X.3 parameters for a specific async sap. AsySapProfEntry .1.3.6.1.4.1.495.2.1.6.30.22.1 |
asySapProfSapNumberIdentifies the SAP (service access point) using a unique numerical value.ro SapIndex .1.3.6.1.4.1.495.2.1.6.30.22.1.1 |
asySapProfParameter1Defines the X.3 parameter 1, PAD recall using a character. This parameter
allows the start-stop mode DTE (user) to initiate an escape from the data
transfer or the connection in progress state in order to send PAD command signals.
Range of Values:
0: Not possible
1: Character DLE
32 to 126: Graphic character defined by user
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.5 |
asySapProfParameter2Defines the X.3 parameter 2, Echo. This parameter provides for characters
received from the start-stop mode DTE (user) to be transmitted back to the
start-stop mode DTE as well as being interpreted by the PAD.
Options:
0: No echo
1: Echo
Default Value: No echo
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.6 |
asySapProfParameter3Defines the X.3 parameter 3, Selection of data forwarding character(s). This
parameter allows the selection of defined sets of characters received from
the start-stop mode DTE (user) to be recognized by the PAD as an indication
to complete the assembly and forward a complete packet
Range of Values:
0: No data forwarding character(s)
1: Alphanumeric characters (A-Z, a-z and 0-9)
2: Character CR
4: Characters ESC, BEL, ENQ and ACK
6: Characters CR, ESC, BEL, ENQ and ACK
8: Characters DEL, CAN and DC2
16: Characters ETX and EOT
18: Characters CR, ETX and EOT
32: Characters HT, LF, VT and FF
64: All characters in columns 0 and 1 of IA5 except those shown
for values 2, 4, 8 and 32
126: All characters in columns 0 and 1 and character DEL
Note: Some values are combinations of other values
(i.e., value 18 is a combination of values 2 and 16).
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.7 |
asySapProfParameter4Defines the X.3 parameter 4, Selection of idle timer delay, in tenths of a
second. This parameter allows the selection of the duration of an interval
between successive characters received from the start-stop mode DTE (user).
When the interval is exceeded, the PAD terminates the assembly of the packet
and forwards it.
Range of Values: 0 to 255
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.8 |
asySapProfParameter5Defines the X.3 parameter 5, Ancillary device control. This parameter allows
for flow control between the PAD and the start-stop mode DTE (user).
Options:
0: No use of X-ON (DC1) and X-OFF (DC3)
1: Use of X-ON and X-OFF (data transfer)
2: Use of X-ON and X-OFF (data transfer and command).
Default Value: No use of X-ON (DC1) and X-OFF (DC3)
Configuration Changed: Operative
Note: Object asySapProfParameter27, Flow control on character to
ancillary device, and object asySapProfParameter28, Flow control
off character to ancillary device, are allowed only if this object is
set to No use of X-ON (DC1) and X-OFF (DC3).rw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.9 |
asySapProfParameter6Defines the X.3 parameter 6, Control of PAD service signals and PAD command
signals. This parameter provides the start-stop mode DTE (user) with the
ability to decide whether or not and in what format PAD service signals are
transmitted
Range of Values:
0: No PAD service signals are transmitted to the start-stop mode DTE
1: PAD service signals are transmitted in the standard format
5: PAD service signals and prompt PAD service signal are transmitted
in the standard format
Default Value: 0
Configuration Changed: Operative
The following values are currently not supported:
8 to 15 - PAD service signals are transmitted in a network dependent format
16 - Extended dialog mode, PAD service signals are in English
32 - Extended dialog mode, PAD service signals are in French
48 - Extended dialog mode, PAD service signals are in Spanishrw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.10 |
asySapProfParameter7Defines the X.3 parameter 7, Selection of operation of the PAD on receipt
of a break signal from the start-stop mode DTE. This parameter allows the
selection of the operation of the PAD after the receipt of a break signal
from the start-stop mode DTE (user).
Range of Values:
0: Nothing
1: Interrupt
2: Reset
4: Send to DTE an indication of break PAD message
5: Interrupt and indication of break
8: Escape from data transfer state
16: Discard output, to start-stop mode DTE
21: Discard output, interrupt and indication of break
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.11 |
asySapProfParameter8Defines the X.3 parameter 8, Discard output. This parameter provides for a
PAD to discard the content of user sequences in packets upon request rather
than disassembling and transmitting these to the start-stop mode DTE (user).
Options:
0: Normal data delivery
1: Discard output
Default Value: Normal data delivery
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.12 |
asySapProfParameter9Defines the X.3 parameter 9, Padding after carriage return (CR). This
parameter provides for the automatic insertion of padding characters by the
PAD after a carriage return by the DTE (user). This allows the printer of the
DTE to perform the carriage return function correctly.
Range of Values: 0 to 255
0: No padding after CR
1 to 255: Number of padding characters inserted after CR
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.13 |
asySapProfParameter10Defines the X.3 parameter 10, Line folding. This parameter provides for
the automatic insertion of graphic characters by the PAD in the character
stream transmitted to the start-stop mode DTE (user). The predetermined
maximum number of graphic characters per line may be set.
Range of Values: 0 to 255
0: No line folding
1 to 255: Number of graphic characters per line
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.14 |
asySapProfParameter11Defines the X.3 parameter 11, Binary speed of start-stop mode DTE.
Options:
0: 110 bit/s
1: 134.5 bit/s
2: 300 bit/s
3: 1200 bit/s
4: 600 bit/s
5: 75 bit/s
6: 150 bit/s
7: 1800 bit/s
8: 200 bit/s
9: 100 bit/s
10: 50 bit/s
11: 75/1200 bit/s (not supported)
12: 2400 bit/s
13: 4800 bit/s
14: 9600 bit/s
15: 19200 bit/s
16: 48000 bit/s
17: 56000 bit/s
18: 64000 bit/s
19: 14400 bit/s
20: 38400 bit/s
21: 57600 bit/s
22: 115200 bit/s
255: non standard bit rate
Default Value: 110 bit/sro INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.15 |
asySapProfParameter12Defines the X.3 parameter 12, Flow control of the PAD. This parameter
allows for flow control between the start-stop mode DTE (user) and the PAD.
Options:
0: No use of X-ON (DC1) and X-OFF (DC3) for flow control
1: Use of X-ON (DC1) and X-OFF (DC3) for flow control
Default Value: No use of X-ON (DC1) and X-OFF (DC3) for flow control
Configuration Changed: Operative
Note: Object asyProfParameter25, Flow control on character to PAD, and
object asyProfParameter26, Flow control off character to PAD, are
allowed only if this object is set to No use of X-ON (DC1) and X-OFF (DC3).rw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.16 |
asySapProfParameter13Defines the X.3 parameter 13, Linefeed insertion after carriage return. This
parameter allows for the automatic insertion of a linefeed character in the
character stream to and from the start-stop DTE (user) or after each carriage
return. This parameter applies only in
the data transfer state.
Range of Values:
0: No linefeed insertion
1: Insert linefeed after transmission of CR to the start-stop mode DTE
2: Insert linefeed after each CR in the data stream from the start-stop mode DTE
4: Insert linefeed after echo of CR to start-stop mode DTE
5: Insert linefeed after transmission to the start-stop mode DTE and after
echo of CR
6: Insert linefeed in data stream after CR from start-stop mode DTE
and after an echo of a CR to the start-stop mode DTE
7: Insert linefeed in the data stream to and from the start-stop
mode DTE and after an echo of a CR to the start-stop mode DTE
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.17 |
asySapProfParameter14Defines the X.3 parameter 14, Padding after linefeed. This parameter provides
for the automatic insertion of padding characters in the character stream
transmitted to the start-stop mode DTE (user) after the occurrence of a
linefeed character. This allows the printer of the DTE to perform the
linefeed operation correctly. This parameter applies only in the data
transfer state.
Range of Values:0 to 7
0: No padding after linefeed
1 to 7: Number of padding characters inserted after linefeed
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.18 |
asySapProfParameter15Defines the X.3 parameter 15, Editing. This parameter provides for character
size delete, line delete and line display editing capabilities in the PAD
command state and the data transfer state for the start-stop mode DTE (user).
Options:
0: No use of editing in the data transfer state
1: Use of editing in the data transfer state
Default Value: No editing
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.19 |
asySapProfParameter16Defines the X.3 parameter 16, Character delete.
Range of Values: 0 to 127
0 to126: One character from IA5
127: Character 7/15 (DEL)
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.20 |
asySapProfParameter17Defines the X.3 parameter 17, Line delete.
Range of Values: 0 to 127
0 to 23: One character from the range of IA5
24: Character 1/8 (CAN)
25 to 127: One character from the range of IA5
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.21 |
asySapProfParameter18Defines the X.3 parameter 18, Line display.
Range of Values: 0 to 127
0 to 17: One character from the range of IA5
18: Character 1/8 (DC2)
19 to 127: One character from the range of IA5
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.22 |
asySapProfParameter19Defines the X.3 parameter 19, Editing PAD service signals. This parameter
provides the start-stop mode DTE (user) with the ability to decide whether or
not editing PAD service signals are transmitted and which format should be used.
Range of Values:
0 = No editing PAD service signals
1: Editing PAD service signals for printing terminals
2: Editing PAD service signals for display terminals
8, 32 to 126: Editing PAD service signals using one character from the range of IA5
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.23 |
asySapProfParameter20Defines the X.3 parameter 20, Echo mask. This parameter allows selected
defined sets of characters received from the start-stop mode DTE (user) not to be
transmitted back to the DTE.
Range of Values:
0: No echo mask (all characters echoed)
1: No echo of CR
2: No echo of LF
4: No echo of VT, HT and FF
8: No echo of BEL and BS
16: No echo of ESC and ENQ
32: No echo of ACK, NAK, STX, SOH, EOT, ETB and ETX
64: No echo of editing characters as designated by parameters 16, 17 and 18
128: No echo of all other characters in columns 0 and 1 not mentioned
above and DEL
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.24 |
asySapProfParameter21Defines the X.3 parameter 21, Parity treatment. This parameter allows the
PAD to check parity in the data stream from the start-stop mode DTE (user) or
generate parity in the data stream to the DTE.
Options:
0: No parity checking or generation
1: Parity checking
2: Parity generation
3: Parity checking and parity generation
Default Value: No parity checking or generation
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.25 |
asySapProfParameter22Defines the X.3 parameter 22, Page wait. This parameter allows the PAD to
suspend transmission of additional characters to the start-stop mode DTE
(user) after a specified number of linefeed characters have been
transmitted by the PAD.
Range of Values: 0 to 255
0: Page wait disable
1 to 255: Number of line feed characters considered by the PAD
for the page wait function
Default Value: 0
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.26 |
asySapProfParameter23Defines parameter 23 (extension to X.3), Receive parity type.
Options:
0: Parity disable
1: Even parity
2: Odd parity
3: Space parity
4: Mark parity
Default Value: Parity disable
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.27 |
asySapProfParameter24Defines parameter 24 (extension to X.3), Transmit parity type.
Options:
0: Parity disable
1: Even parity
2: Odd parity
3: Space parity
4: Mark parity
Default Value: Parity disable
Configuration Changed: Operativerw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.28 |
asySapProfParameter25Defines parameter 25 (extension to X.3), Flow control on character to PAD.
Range of Values: 0 to 127
0 to 18: One character from the range of IA5
19: DC3
20 to 127: One character from the range of IA5
Default Value: 0
Configuration Changed: Operative
Note: This object is allowed only if object asySapProfParameter12, Flow control
of the PAD, is set to No use of X-ON (DC1) and X-OFF (DC3).rw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.29 |
asySapProfParameter26Defines parameter 26 (extension to X.3), Flow control off character to PAD.
Range of Values: 0 to 127
0 to 16: One character from the range of IA5
17 = DC1
18 to 127: One character from the range of IA5
Default Value: 0
Configuration Changed: Operative
Note: This object is allowed only if object asySapProfParameter12,
Flow control of the PAD, is set to No use of X-ON (DC1) and X-OFF (DC3).rw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.30 |
asySapProfParameter27Defines parameter 27 (extension to X.3), Flow control on character to
ancillary device.
Range of Values: 0 to 127
Note:
0 to 18: One character from the range of IA5
19: DC3
20 to 127: One character from the range of IA5
Default Value: 0
Configuration Changed: Operative
Note:
This object is allowed only if object asySapProfParameter5, Ancillary device
control, is set to No use of X-ON (DC1) and X-OFF (DC3).rw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.31 |
asySapProfParameter28Defines parameter 28 (extension to X.3), Flow control off character to
ancillary device.
Range of Values: 0 to 127
0 to 16: One character from the range of IA5
17: DC1
18 to 127: One character from the range of IA5
Default Value: 0
Configuration Changed: Operative
Note:
This object is allowed only if object
asySapProfParameter5, Ancillary device
control, is set to No use of X-ON (DC1)
and X-OFF (DC3).rw INTEGER .1.3.6.1.4.1.495.2.1.6.30.22.1.32 |
asyDteTableA table containing the DTE X.28 Selection command objects for each defined
'abbreviated address'. SEQUENCE OF AsyDteEntry .1.3.6.1.4.1.495.2.1.6.30.23 |
asyDteEntryThe objects for a specific DTE X.28 Selection entry. AsyDteEntry .1.3.6.1.4.1.495.2.1.6.30.23.1 |
asyDteNumberIdentifies the DTE X.28 Selection entry by a unique numerical value.ro DteIndex .1.3.6.1.4.1.495.2.1.6.30.23.1.1 |
asyDteRowStatusIndicates whether this specific entry is configured within the MIB.
Entries (rows) may be created by setting this object value to 'valid',
or deleted by changing this object value to 'invalid'.rw Enumeration .1.3.6.1.4.1.495.2.1.6.30.23.1.2 |
asyDteAliasIdentifies the DTE entry by a textual name. Names are unique per service
access point.
Note:
Dte alias (name) must be preceded by a '.' (period) when used in an X.28
Selection with abbreviated address.rw Alias .1.3.6.1.4.1.495.2.1.6.30.23.1.3 |
asyDteCalledAddressDefines the network address of a remote device for this DTE entry.
Allowable values: 1 to 15 numerical digits.rw DisplayString .1.3.6.1.4.1.495.2.1.6.30.23.1.5 |
asyDteFacilityFieldDefines the facility codes and parameters requires for the X.28
Selection command for this DTE entry. The facility codes and parameters
must be entered as defined in the CCITT X.28 Recommendation.
The following facilities are supported:
- CUG facility
- CUG with OA facility
- Called address extension facility
- Call reselection prevention
- Fast select with restriction on response
- Fast select
- Reverse charge
- Charge request
- Network User ID
A value of null string (blank) means no facilities.rw DisplayString .1.3.6.1.4.1.495.2.1.6.30.23.1.6 |
asyDteUserDataFieldDefines the user data field of the X.28 Selection command for this DTE
entry. A value of nul string (blank) means no user data.rw DisplayString .1.3.6.1.4.1.495.2.1.6.30.23.1.7 |
asyDteX3ProfileDefines the X.3 Profile number for a specific set of X.3 parameters.
The Async layer will initialize its SAP to this X.3 Profile before
establishing a logical connection for this DTE entry. a value of '0'
means no X.3 Profile.rw INTEGER .1.3.6.1.4.1.495.2.1.6.30.23.1.8 |