CTTRAPLOG-MIB
Standard SNMP MIB module defining data structures for CTTRAPLOG-MIB.
Imported Objects
Objects
35 total| Object Name |
|---|
RFC1155-SMIro INTEGER .1.3.6.1.4.1.52.4.1.44.1 |
configTable SEQUENCE OF ConfigTableEntry .1.3.6.1.4.1.52.4.1.44.2 |
configTableEntry ConfigTableEntry .1.3.6.1.4.1.52.4.1.44.2.1 |
slotInChassisro INTEGER .1.3.6.1.4.1.52.4.1.44.2.1.1 |
numEntriesLoggedsro Counter .1.3.6.1.4.1.52.4.1.44.2.1.2 |
numEntriesRequestedrw INTEGER .1.3.6.1.4.1.52.4.1.44.2.1.3 |
numEntriesAllocatedro INTEGER .1.3.6.1.4.1.52.4.1.44.2.1.4 |
lastLoggedEntryLogIdro INTEGER .1.3.6.1.4.1.52.4.1.44.2.1.5 |
logCommandrw Enumeration .1.3.6.1.4.1.52.4.1.44.2.1.6 |
wrapro INTEGER .1.3.6.1.4.1.52.4.1.44.2.1.7 |
trapLogTable SEQUENCE OF TrapLogEntry .1.3.6.1.4.1.52.4.1.44.3 |
trapLogEntry TrapLogEntry .1.3.6.1.4.1.52.4.1.44.3.1 |
logIdro INTEGER .1.3.6.1.4.1.52.4.1.44.3.1.1 |
nvmpIdro INTEGER .1.3.6.1.4.1.52.4.1.44.3.1.2 |
trapLogAcknowledgedro INTEGER .1.3.6.1.4.1.52.4.1.44.3.1.3 |
trapLogVarBindro OCTET STRING .1.3.6.1.4.1.52.4.1.44.3.1.4 |
trapLogDescriptionro DisplayString .1.3.6.1.4.1.52.4.1.44.3.1.5 |
timeLoggedro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.52.4.1.44.3.1.6 |
filterIdro Enumeration .1.3.6.1.4.1.52.4.1.44.3.1.7 |
slotChassisro INTEGER .1.3.6.1.4.1.52.4.1.44.3.1.8 |
trapOIDro OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.44.3.1.9 |
z80Timero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.52.4.1.44.3.1.10 |
filterTable SEQUENCE OF FilterEntry .1.3.6.1.4.1.52.4.1.44.4 |
filterEntry FilterEntry .1.3.6.1.4.1.52.4.1.44.4.1 |
filterLogIdro INTEGER .1.3.6.1.4.1.52.4.1.44.4.1.1 |
filterNvmpIdro INTEGER .1.3.6.1.4.1.52.4.1.44.4.1.2 |
filterTrapLogAcknowledgedro INTEGER .1.3.6.1.4.1.52.4.1.44.4.1.3 |
filterTrapLogVarBindro OCTET STRING .1.3.6.1.4.1.52.4.1.44.4.1.4 |
filterTrapLogDescriptionro DisplayString .1.3.6.1.4.1.52.4.1.44.4.1.5 |
filterTimeLoggedro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.52.4.1.44.4.1.6 |
filterFilterIdro Enumeration .1.3.6.1.4.1.52.4.1.44.4.1.7 |
filterSlotInChassisro INTEGER .1.3.6.1.4.1.52.4.1.44.4.1.8 |
filterTrapOIDro OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.44.4.1.9 |
filterZ80Timero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.52.4.1.44.4.1.10 |
trapLoggerAgentrw Enumeration .1.3.6.1.4.1.52.4.1.44.5 |
CTTRAPLOG-MIB Technical Reference Overview
The CTTRAPLOG-MIB SNMP MIB module published by Cabletron defines 35 managed OID objects, including 29 scalar/column metrics, 3 SNMP tables, and 0 trap/notification events. Key tabular structures include configTable, trapLogTable, filterTable.
Key OID Definitions in CTTRAPLOG-MIB
.1.3.6.1.4.1.52.4.1.44.1Total number of logged entries for this chassis.
.1.3.6.1.4.1.52.4.1.44.5Reflects the operational status of the traplogger agent
.1.3.6.1.4.1.52.4.1.44.2.1Each entry allows a user to configure the alarm table for a specific slot. Objects such as Current Entry, MaxEntries Allowed, and an Enable/Disable switch are available.
.1.3.6.1.4.1.52.4.1.44.2.1.1Each Slot can be separately configured. This is the slot number for the configuration entry.
.1.3.6.1.4.1.52.4.1.44.2.1.2This is the total number of entries looged for this slot.
.1.3.6.1.4.1.52.4.1.44.2.1.3Maximum number of entries to store before wrapping the log on this slot.
.1.3.6.1.4.1.52.4.1.44.2.1.4This is the number of entries allocated to log alarms on this slot. It will always be less than or equal to the requested number of entries.
.1.3.6.1.4.1.52.4.1.44.2.1.5This is the log id of the last entry logged for this slot.
.1.3.6.1.4.1.52.4.1.44.2.1.6Allows the user to send the log the commands specified in the enumeration.
.1.3.6.1.4.1.52.4.1.44.2.1.7This is whether or not this configuration has wrapped or not.
.1.3.6.1.4.1.52.4.1.44.3.1Each alarm entry is generated from one of the following sources; (1) a module in one of the main chassis slots, (2) the EM, (3) or a power supply.
.1.3.6.1.4.1.52.4.1.44.3.1.1Each slot has a maximium number of log entries that it can support. Each entry is assigned a monotonically increasing sequence number. When the maximum number of entries for a slot is reached, the log wraps. Each new entry will replace the oldest entry for that slot.
.1.3.6.1.4.1.52.4.1.44.3.1.2This contains the nvmp id of the trap that occurred.
.1.3.6.1.4.1.52.4.1.44.3.1.3This field is set to 2 if a trap as been acknowledged from the EM.
.1.3.6.1.4.1.52.4.1.44.3.1.4This is an ASN.1 encoded string representing the pairs of OID/value items supplied in the original SNMP or NVMP trap.
.1.3.6.1.4.1.52.4.1.44.3.1.5This is an internally defined string used to describe an alarm. Its primary use is for display on the EMs LCD. A default value will be used for the old trap calls.
.1.3.6.1.4.1.52.4.1.44.3.1.6The time the entry was logged. This will be date and time if possible.
.1.3.6.1.4.1.52.4.1.44.3.1.7This will be used to filter certain alarms. The criteria is TBD. An example of classification: informational - requires no intervention. warning - Does not require immediate intervention. e.g. static risk severe - Requires immediate intervention. e.g. power overload. fatal - Requires attention and module may take corrective action such as reboot. e.g. Unrecoverable software or hardware error.
.1.3.6.1.4.1.52.4.1.44.3.1.8Slot of this trap log.
.1.3.6.1.4.1.52.4.1.44.3.1.9This OID combines the General Trap code, Specific Trap code, and the sys object id into one OID.
.1.3.6.1.4.1.52.4.1.44.3.1.10This is the time that the Z80 has been up for the board that sent this trap.
.1.3.6.1.4.1.52.4.1.44.4.1Each filter entry is generated from one of the following sources; (1) a module in one of the main chassis slots, (2) the EM, (3) or a power supply.
.1.3.6.1.4.1.52.4.1.44.4.1.1Each slot has a maximum number of log entries that it can support. Each entry is assigned a monotonically increasing sequence number. When the maximum number of entries for a slot is reached, the log wraps. Each new entry willreplace the oldest entry for that slot.
.1.3.6.1.4.1.52.4.1.44.4.1.2This contains the nvmp id of the trap that was generated.
More MIBs from Cabletron
Browse all CabletronMIBs →SNMP MIB module
Standard SNMP MIB module defining data structures for CTRON-SFCS-MIB.
Standard SNMP MIB module defining data structures for CABLETRON-TRAPS.
SNMP MIB module
Standard SNMP MIB module defining data structures for ADIC-SANMGR-PROXY-MIB.
The CTRON-AP3000-MIB module enables read-write SNMP configuration management for Enterasys AP3000 wireless access points under the Enterasys enterprise OID. It provides programmatic access to device-specific operational parameters and settings required for provisioning and maintaining the AP3000 hardware.