Home/Catalog/CTTRAPLOG-MIB

CTTRAPLOG-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for CTTRAPLOG-MIB.

35
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

35 total
Object Name
RFC1155-SMITotal number of logged entries for this chassis.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.1
configTable
SEQUENCE OF ConfigTableEntry
.1.3.6.1.4.1.52.4.1.44.2
configTableEntryEach entry allows a user to configure the alarm table for a specific slot. Objects such as Current Entry, MaxEntries Allowed, and an Enable/Disable switch are available.
ConfigTableEntry
.1.3.6.1.4.1.52.4.1.44.2.1
slotInChassisEach Slot can be separately configured. This is the slot number for the configuration entry.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.2.1.1
numEntriesLoggedsThis is the total number of entries looged for this slot.ro
Counter
.1.3.6.1.4.1.52.4.1.44.2.1.2
numEntriesRequestedMaximum number of entries to store before wrapping the log on this slot.rw
INTEGER
.1.3.6.1.4.1.52.4.1.44.2.1.3
numEntriesAllocatedThis is the number of entries allocated to log alarms on this slot. It will always be less than or equal to the requested number of entries.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.2.1.4
lastLoggedEntryLogIdThis is the log id of the last entry logged for this slot.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.2.1.5
logCommandAllows the user to send the log the commands specified in the enumeration.rw
Enumeration
.1.3.6.1.4.1.52.4.1.44.2.1.6
wrapThis is whether or not this configuration has wrapped or not.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.2.1.7
trapLogTable
SEQUENCE OF TrapLogEntry
.1.3.6.1.4.1.52.4.1.44.3
trapLogEntryEach alarm entry is generated from one of the following sources; (1) a module in one of the main chassis slots, (2) the EM, (3) or a power supply.
TrapLogEntry
.1.3.6.1.4.1.52.4.1.44.3.1
logIdEach slot has a maximium number of log entries that it can support. Each entry is assigned a monotonically increasing sequence number. When the maximum number of entries for a slot is reached, the log wraps. Each new entry will replace the oldest entry for that slot.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.3.1.1
nvmpIdThis contains the nvmp id of the trap that occurred.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.3.1.2
trapLogAcknowledgedThis field is set to 2 if a trap as been acknowledged from the EM.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.3.1.3
trapLogVarBindThis is an ASN.1 encoded string representing the pairs of OID/value items supplied in the original SNMP or NVMP trap.ro
OCTET STRING
.1.3.6.1.4.1.52.4.1.44.3.1.4
trapLogDescriptionThis is an internally defined string used to describe an alarm. Its primary use is for display on the EMs LCD. A default value will be used for the old trap calls.ro
DisplayString
.1.3.6.1.4.1.52.4.1.44.3.1.5
timeLoggedThe time the entry was logged. This will be date and time if possible.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.52.4.1.44.3.1.6
filterIdThis will be used to filter certain alarms. The criteria is TBD. An example of classification: informational - requires no intervention. warning - Does not require immediate intervention. e.g. static risk severe - Requires immediate intervention. e.g. power overload. fatal - Requires attention and module may take corrective action such as reboot. e.g. Unrecoverable software or hardware error.ro
Enumeration
.1.3.6.1.4.1.52.4.1.44.3.1.7
slotChassisSlot of this trap log.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.3.1.8
trapOIDThis OID combines the General Trap code, Specific Trap code, and the sys object id into one OID.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.4.1.44.3.1.9
z80TimeThis is the time that the Z80 has been up for the board that sent this trap.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.52.4.1.44.3.1.10
filterTable
SEQUENCE OF FilterEntry
.1.3.6.1.4.1.52.4.1.44.4
filterEntryEach filter entry is generated from one of the following sources; (1) a module in one of the main chassis slots, (2) the EM, (3) or a power supply.
FilterEntry
.1.3.6.1.4.1.52.4.1.44.4.1
filterLogIdEach slot has a maximum number of log entries that it can support. Each entry is assigned a monotonically increasing sequence number. When the maximum number of entries for a slot is reached, the log wraps. Each new entry willreplace the oldest entry for that slot.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.4.1.1
filterNvmpIdThis contains the nvmp id of the trap that was generated.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.4.1.2
filterTrapLogAcknowledgedThis field is non-zero if a trap has been acknowleged from the EM.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.4.1.3
filterTrapLogVarBindThis is an ASN.1 encoded string representing the pairs of OID/value items supplied in the original SNMP or NVMP trap.ro
OCTET STRING
.1.3.6.1.4.1.52.4.1.44.4.1.4
filterTrapLogDescriptionThis is an internally defined string used to describe an alarm. It's primary use is for display on the EMs LCD. A default value will be used for the old trap calls.ro
DisplayString
.1.3.6.1.4.1.52.4.1.44.4.1.5
filterTimeLoggedThe time the entry was logged. This will be date and time if possible.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.52.4.1.44.4.1.6
filterFilterIdThis will be used tofilter certain alarms. The criteria is TBD. An example of classification: informational-requires no intervention. warning - Does not require immediate intervention. e.g. statis risk severe - Requires immediate intervention. e.g. power overload. fatal - Requires attention and module may take corrective action such as reboot. e.g. Unrecoverale software or hardware error.ro
Enumeration
.1.3.6.1.4.1.52.4.1.44.4.1.7
filterSlotInChassisSlot of this filter entry.ro
INTEGER
.1.3.6.1.4.1.52.4.1.44.4.1.8
filterTrapOIDThis OID combines the General Trap code, Specific Trap code, and the sys object id into one OID.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.4.1.44.4.1.9
filterZ80TimeThe number of time ticks that have passed since this boards Z80 processor has been up.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.52.4.1.44.4.1.10
trapLoggerAgentReflects the operational status of the traplogger agentrw
Enumeration
.1.3.6.1.4.1.52.4.1.44.5