Home/Catalog/CTTRAPLOG-MIB

CTTRAPLOG-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for CTTRAPLOG-MIB.

35
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

35 total
Object Name
RFC1155-SMIro
INTEGER
.1.3.6.1.4.1.52.4.1.44.1
configTable
SEQUENCE OF ConfigTableEntry
.1.3.6.1.4.1.52.4.1.44.2
configTableEntry
ConfigTableEntry
.1.3.6.1.4.1.52.4.1.44.2.1
slotInChassisro
INTEGER
.1.3.6.1.4.1.52.4.1.44.2.1.1
numEntriesLoggedsro
Counter
.1.3.6.1.4.1.52.4.1.44.2.1.2
numEntriesRequestedrw
INTEGER
.1.3.6.1.4.1.52.4.1.44.2.1.3
numEntriesAllocatedro
INTEGER
.1.3.6.1.4.1.52.4.1.44.2.1.4
lastLoggedEntryLogIdro
INTEGER
.1.3.6.1.4.1.52.4.1.44.2.1.5
logCommandrw
Enumeration
.1.3.6.1.4.1.52.4.1.44.2.1.6
wrapro
INTEGER
.1.3.6.1.4.1.52.4.1.44.2.1.7
trapLogTable
SEQUENCE OF TrapLogEntry
.1.3.6.1.4.1.52.4.1.44.3
trapLogEntry
TrapLogEntry
.1.3.6.1.4.1.52.4.1.44.3.1
logIdro
INTEGER
.1.3.6.1.4.1.52.4.1.44.3.1.1
nvmpIdro
INTEGER
.1.3.6.1.4.1.52.4.1.44.3.1.2
trapLogAcknowledgedro
INTEGER
.1.3.6.1.4.1.52.4.1.44.3.1.3
trapLogVarBindro
OCTET STRING
.1.3.6.1.4.1.52.4.1.44.3.1.4
trapLogDescriptionro
DisplayString
.1.3.6.1.4.1.52.4.1.44.3.1.5
timeLoggedro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.52.4.1.44.3.1.6
filterIdro
Enumeration
.1.3.6.1.4.1.52.4.1.44.3.1.7
slotChassisro
INTEGER
.1.3.6.1.4.1.52.4.1.44.3.1.8
trapOIDro
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.4.1.44.3.1.9
z80Timero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.52.4.1.44.3.1.10
filterTable
SEQUENCE OF FilterEntry
.1.3.6.1.4.1.52.4.1.44.4
filterEntry
FilterEntry
.1.3.6.1.4.1.52.4.1.44.4.1
filterLogIdro
INTEGER
.1.3.6.1.4.1.52.4.1.44.4.1.1
filterNvmpIdro
INTEGER
.1.3.6.1.4.1.52.4.1.44.4.1.2
filterTrapLogAcknowledgedro
INTEGER
.1.3.6.1.4.1.52.4.1.44.4.1.3
filterTrapLogVarBindro
OCTET STRING
.1.3.6.1.4.1.52.4.1.44.4.1.4
filterTrapLogDescriptionro
DisplayString
.1.3.6.1.4.1.52.4.1.44.4.1.5
filterTimeLoggedro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.52.4.1.44.4.1.6
filterFilterIdro
Enumeration
.1.3.6.1.4.1.52.4.1.44.4.1.7
filterSlotInChassisro
INTEGER
.1.3.6.1.4.1.52.4.1.44.4.1.8
filterTrapOIDro
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.4.1.44.4.1.9
filterZ80Timero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.52.4.1.44.4.1.10
trapLoggerAgentrw
Enumeration
.1.3.6.1.4.1.52.4.1.44.5

CTTRAPLOG-MIB Technical Reference Overview

The CTTRAPLOG-MIB SNMP MIB module published by Cabletron defines 35 managed OID objects, including 29 scalar/column metrics, 3 SNMP tables, and 0 trap/notification events. Key tabular structures include configTable, trapLogTable, filterTable.

Key OID Definitions in CTTRAPLOG-MIB

RFC1155-SMIINTEGERread-only
.1.3.6.1.4.1.52.4.1.44.1

Total number of logged entries for this chassis.

trapLoggerAgentINTEGERread-write
.1.3.6.1.4.1.52.4.1.44.5

Reflects the operational status of the traplogger agent

configTableEntryConfigTableEntrynot-accessible
.1.3.6.1.4.1.52.4.1.44.2.1

Each entry allows a user to configure the alarm table for a specific slot. Objects such as Current Entry, MaxEntries Allowed, and an Enable/Disable switch are available.

slotInChassisINTEGERread-only
.1.3.6.1.4.1.52.4.1.44.2.1.1

Each Slot can be separately configured. This is the slot number for the configuration entry.

numEntriesLoggedsCounterread-only
.1.3.6.1.4.1.52.4.1.44.2.1.2

This is the total number of entries looged for this slot.

numEntriesRequestedINTEGERread-write
.1.3.6.1.4.1.52.4.1.44.2.1.3

Maximum number of entries to store before wrapping the log on this slot.

numEntriesAllocatedINTEGERread-only
.1.3.6.1.4.1.52.4.1.44.2.1.4

This is the number of entries allocated to log alarms on this slot. It will always be less than or equal to the requested number of entries.

lastLoggedEntryLogIdINTEGERread-only
.1.3.6.1.4.1.52.4.1.44.2.1.5

This is the log id of the last entry logged for this slot.

logCommandINTEGERread-write
.1.3.6.1.4.1.52.4.1.44.2.1.6

Allows the user to send the log the commands specified in the enumeration.

wrapINTEGERread-only
.1.3.6.1.4.1.52.4.1.44.2.1.7

This is whether or not this configuration has wrapped or not.

trapLogEntryTrapLogEntrynot-accessible
.1.3.6.1.4.1.52.4.1.44.3.1

Each alarm entry is generated from one of the following sources; (1) a module in one of the main chassis slots, (2) the EM, (3) or a power supply.

logIdINTEGERread-only
.1.3.6.1.4.1.52.4.1.44.3.1.1

Each slot has a maximium number of log entries that it can support. Each entry is assigned a monotonically increasing sequence number. When the maximum number of entries for a slot is reached, the log wraps. Each new entry will replace the oldest entry for that slot.

nvmpIdINTEGERread-only
.1.3.6.1.4.1.52.4.1.44.3.1.2

This contains the nvmp id of the trap that occurred.

trapLogAcknowledgedINTEGERread-only
.1.3.6.1.4.1.52.4.1.44.3.1.3

This field is set to 2 if a trap as been acknowledged from the EM.

trapLogVarBindOCTETread-only
.1.3.6.1.4.1.52.4.1.44.3.1.4

This is an ASN.1 encoded string representing the pairs of OID/value items supplied in the original SNMP or NVMP trap.

trapLogDescriptionDisplayStringread-only
.1.3.6.1.4.1.52.4.1.44.3.1.5

This is an internally defined string used to describe an alarm. Its primary use is for display on the EMs LCD. A default value will be used for the old trap calls.

timeLoggedTimeTicksread-only
.1.3.6.1.4.1.52.4.1.44.3.1.6

The time the entry was logged. This will be date and time if possible.

filterIdINTEGERread-only
.1.3.6.1.4.1.52.4.1.44.3.1.7

This will be used to filter certain alarms. The criteria is TBD. An example of classification: informational - requires no intervention. warning - Does not require immediate intervention. e.g. static risk severe - Requires immediate intervention. e.g. power overload. fatal - Requires attention and module may take corrective action such as reboot. e.g. Unrecoverable software or hardware error.

slotChassisINTEGERread-only
.1.3.6.1.4.1.52.4.1.44.3.1.8

Slot of this trap log.

trapOIDOBJECTread-only
.1.3.6.1.4.1.52.4.1.44.3.1.9

This OID combines the General Trap code, Specific Trap code, and the sys object id into one OID.

z80TimeTimeTicksread-only
.1.3.6.1.4.1.52.4.1.44.3.1.10

This is the time that the Z80 has been up for the board that sent this trap.

filterEntryFilterEntrynot-accessible
.1.3.6.1.4.1.52.4.1.44.4.1

Each filter entry is generated from one of the following sources; (1) a module in one of the main chassis slots, (2) the EM, (3) or a power supply.

filterLogIdINTEGERread-only
.1.3.6.1.4.1.52.4.1.44.4.1.1

Each slot has a maximum number of log entries that it can support. Each entry is assigned a monotonically increasing sequence number. When the maximum number of entries for a slot is reached, the log wraps. Each new entry willreplace the oldest entry for that slot.

filterNvmpIdINTEGERread-only
.1.3.6.1.4.1.52.4.1.44.4.1.2

This contains the nvmp id of the trap that was generated.

More MIBs from Cabletron