CTRON-UPS-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
Imported Objects
Objects
10 total| Object Name |
|---|
ctUPS OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.5.4.1 |
CTRON-MIB-NAMES Unknown .1.3.6.1.4.1.52.4.1.5.4.1 |
ctUpsIDrw Enumeration .1.3.6.1.4.1.52.4.1.5.4.1.1 |
ctUpsUpTimerodeprecated INTEGER .1.3.6.1.4.1.52.4.1.5.4.1.2 |
ctUpsDisablerwdeprecated INTEGER .1.3.6.1.4.1.52.4.1.5.4.1.3 |
ctUpsDisconnectrw INTEGER .1.3.6.1.4.1.52.4.1.5.4.1.4 |
ctUpsTestrw Enumeration .1.3.6.1.4.1.52.4.1.5.4.1.5 |
ctUpsBatteryCapacityro INTEGER .1.3.6.1.4.1.52.4.1.5.4.1.6 |
ctUpsACLineVoltsInro INTEGER .1.3.6.1.4.1.52.4.1.5.4.1.7 |
ctUpsBatteryVoltsOutro INTEGER .1.3.6.1.4.1.52.4.1.5.4.1.8 |
CTRON-UPS-MIB Technical Reference Overview
The CTRON-UPS-MIB SNMP MIB module published by Cabletron defines 10 managed OID objects, including 9 scalar/column metrics, 0 SNMP tables, and 0 trap/notification events.
Key OID Definitions in CTRON-UPS-MIB
.1.3.6.1.4.1.52.4.1.5.4.1.1Denotes a type code which refers to the manufacturers and model of the UPS.
.1.3.6.1.4.1.52.4.1.5.4.1.2Denotes the operating time, in hours, since the UPS was last powered on.
.1.3.6.1.4.1.52.4.1.5.4.1.3Allows the UPS to be disabled. A set turns of the UPS for those systems, so equipped. A get/get-next always returns 0.
.1.3.6.1.4.1.52.4.1.5.4.1.4Allows the UPS backup power system to conserve its battery. A set turns off the power system. A get/get-next always returns a 0.
.1.3.6.1.4.1.52.4.1.5.4.1.5Denotes the status performed on the UPS. A write initiates the test. A read indicates status of test.
.1.3.6.1.4.1.52.4.1.5.4.1.6Denotes the percentage of battery capacity left, 100% being a fully-charged battery.
.1.3.6.1.4.1.52.4.1.5.4.1.7Denotes the input AC utility line voltage.
.1.3.6.1.4.1.52.4.1.5.4.1.8Denotes the battery voltage.
More MIBs from Cabletron
Browse all CabletronMIBs →SNMP MIB module
Standard SNMP MIB module defining data structures for CTRON-SFCS-MIB.
Standard SNMP MIB module defining data structures for CABLETRON-TRAPS.
SNMP MIB module
Standard SNMP MIB module defining data structures for ADIC-SANMGR-PROXY-MIB.
The CTRON-AP3000-MIB module enables read-write SNMP configuration management for Enterasys AP3000 wireless access points under the Enterasys enterprise OID. It provides programmatic access to device-specific operational parameters and settings required for provisioning and maintaining the AP3000 hardware.