CTRON-SSR-TRAP-MIB

AI MIB Summary

The CTRON-SSR-TRAP-MIB module defines SNMP trap definitions for Ctron Smart Switch Routers to asynchronously report critical hardware faults, link state transitions, and system events to a network management station.

This module describes the traps specific to the Smart Switch Router.
Main OID:
ssrTrapsMIB.1.3.6.1.4.1.52.2501.1.300
21
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

21 total
Object Name
ssrTrapsMIB
MODULE-IDENTITY
.1.3.6.1.4.1.52.2501.1.300
ssrTrapsConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.2501.1.300.2
ssrTrapsCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.2501.1.300.2.1
ssrTrapsGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.2501.1.300.2.2
trapControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.2501.10.1
envTrapGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.2501.10.2
envPowerSupplyFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.2.1
envPowerSupplyRecovered
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.2.2
envFanFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.2.3
envFanRecovered
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.2.4
envTempExceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.2.5
envTempNormal
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.2.6
envHotSwapIn
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.2.7
envHotSwapOut
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.2.8
envBackupControlModuleOnline
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.2.9
envBackupControlModuleFailure
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.2.10
envLineModuleFailure
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.2.11
envCPUThresholdExceeded
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.2.12
polTrapGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.2501.10.3
polNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.52.2501.10.3.0
polAclDenied
NOTIFICATION-TYPE
.1.3.6.1.4.1.52.2501.10.3.0.1

CTRON-SSR-TRAP-MIB Technical Reference Overview

The CTRON-SSR-TRAP-MIB SNMP MIB module published by Cabletron defines 21 managed OID objects, including 0 scalar/column metrics, 0 SNMP tables, and 13 trap/notification events anchored at base OID .1.3.6.1.4.1.52.2501.1.300. Monitored SNMP traps/notifications include envPowerSupplyFailed, envPowerSupplyRecovered, envFanFailed, envFanRecovered, envTempExceeded, envTempNormal.

Key OID Definitions in CTRON-SSR-TRAP-MIB

ssrTrapsMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.52.2501.1.300

This module describes the traps specific to the Smart Switch Router.

envPowerSupplyFailedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.2.1

A power supply on the sending device has failed. The sysHwPowerSupply object identifies the failed supply.

envPowerSupplyRecoveredNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.2.2

A power supply on the sending device has recovered after failure. The sysHwPowerSupply object identifies the recovered supply.

envFanFailedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.2.3

A Fan tray on the sending device has failed. The sysHwFan object identifies the failed fan tray.

envFanRecoveredNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.2.4

A Fan tray on the sending device has recovered after failure. The sysHwFan object identifies the recovered Fan tray.

envTempExceededNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.2.5

A temperature inside the chassis on the sending device has exceeded normal operating temperature. The sysHwTemperature object identifies the current status.

envTempNormalNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.2.6

A temperature inside the chassis on the sending device has returned to normal operating temperature. The sysHwTemperature object identifies the current status.

envHotSwapInNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.2.7

A module has been inserted into the chassis. sysHwModuleSlotNumber identifies the slot the module was inserted into.

envHotSwapOutNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.2.8

A module has been turned off or removed from the chassis. sysHwModuleSlotNumber identifies the slot the module was removed from.

envBackupControlModuleOnlineNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.2.9

A backup control module that was in standby mode has taken over for a failed primary control module. Poll sysHwControlModuleBackupState for current state of backup control module. sysHwModuleSlotNumber is the index into the sysHwModuleTable for the now active control module.

envBackupControlModuleFailureNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.2.10

A backup control module that was in standby mode has changed to inactive or notInstalled. Poll sysHwControlModuleBackupState for current state of backup control module.

envLineModuleFailureNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.2.11

A line card module which was in the online state changed to the offline state indicating an error condition.

envCPUThresholdExceededNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.2.12

The CPU utilization has exceeded the value of capCPUMaxThreshold after having been below the value of capCPUMinThreshold. Once this trap has occurred it will not occurred again until the utilization has dropped below capCPUMinThreshold. Poll capCPUMinThreshold and capCPUMaxThreshold to determine the configured threshold settings.

polAclDeniedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.52.2501.10.3.0.1

The polAclDenied trap indicates that a message was dropped because of a 'deny' ACL. The polAclName and polAclItem identify the entry in the polAclTable. The ifIndex value identifies the interface on which the deny ACL was applied.