CTRON-POWER-SUPPLY-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
Imported Objects
Objects
69 total| Object Name |
|---|
chPower OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.1 |
CTRON-MIB-NAMES Unknown .1.3.6.1.4.1.52.4.1.1.7.1 |
chPowerOperationalStatusro Enumeration .1.3.6.1.4.1.52.4.1.1.7.1.1 |
chPowerMainVoltageStatusro Enumeration .1.3.6.1.4.1.52.4.1.1.7.1.2 |
chPowerMainVoltagero INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.3 |
chPowerTotalSupplyro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.4 |
chPowerTotalLoadro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.5 |
chPowerMaxSupplyro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.6 |
chPowerMaxLoadro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.7 |
chPowerTable SEQUENCE OF ChPowerEntry .1.3.6.1.4.1.52.4.1.1.7.1.8 |
chPowerEntry ChPowerEntry .1.3.6.1.4.1.52.4.1.1.7.1.8.1 |
chPowerLineIDro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.8.1.1 |
chPowerLineTypero OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.1.8.1.2 |
chPowerLineTotalSupplyro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.8.1.3 |
chPowerLineTotalLoadro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.8.1.4 |
chPowerLineMaxSupplyro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.8.1.5 |
chPowerLineMaxLoadro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.8.1.6 |
chPowerDiagVoltageStatusro Enumeration .1.3.6.1.4.1.52.4.1.1.7.1.9 |
chPowerDiagVoltagero INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.10 |
boardPower OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.2 |
boardPowerSlotStatusTable SEQUENCE OF BoardPowerSlotStatusEntry .1.3.6.1.4.1.52.4.1.1.7.2.1 |
boardPowerSlotStatusEntry BoardPowerSlotStatusEntry .1.3.6.1.4.1.52.4.1.1.7.2.1.1 |
boardPowerSlotStatusIDro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.1.1.1 |
boardPowerOperationalStatusro Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.1.1.2 |
boardPowerAdminStatusrw Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.1.1.3 |
boardPowerLocalAdminStatusrw Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.1.1.4 |
boardPowerLocalStatusro Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.1.1.5 |
boardPowerShutdownAdminrw Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.1.1.6 |
boardPowerPriorityrw INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.1.1.7 |
boardPowerMaxInputPowerro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.1.1.8 |
boardPowerManagementrw Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.1.1.9 |
boardPowerSlotTable SEQUENCE OF BoardPowerSlotEntry .1.3.6.1.4.1.52.4.1.1.7.2.2 |
boardPowerSlotEntry BoardPowerSlotEntry .1.3.6.1.4.1.52.4.1.1.7.2.2.1 |
boardPowerSlotIDro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.1 |
boardPowerIDro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.2 |
boardPowerTypero OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.3 |
boardPowerStatusro Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.2.1.4 |
boardPowerVoltagero INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.5 |
boardPowerCurrentro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.6 |
boardPowerMaxVoltagero INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.7 |
boardPowerMinVoltagero INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.8 |
boardPowerMaxPowerro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.9 |
psPower OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.3 |
psPowerSlotStatusTable SEQUENCE OF PsPowerSlotStatusEntry .1.3.6.1.4.1.52.4.1.1.7.3.1 |
psPowerSlotStatusEntry PsPowerSlotStatusEntry .1.3.6.1.4.1.52.4.1.1.7.3.1.1 |
psPowerSlotStatusIDro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.1.1.1 |
psPowerOperationalStatusro Enumeration .1.3.6.1.4.1.52.4.1.1.7.3.1.1.2 |
psPowerAdminStatusrw Enumeration .1.3.6.1.4.1.52.4.1.1.7.3.1.1.3 |
psPowerMaxOutputPowerro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.1.1.4 |
psPowerSlotTable SEQUENCE OF PsPowerSlotEntry .1.3.6.1.4.1.52.4.1.1.7.3.2 |
psPowerSlotEntry PsPowerSlotEntry .1.3.6.1.4.1.52.4.1.1.7.3.2.1 |
psPowerSlotIDro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.1 |
psPowerIDro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.2 |
psPowerTypero OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.3 |
psPowerStatusro Enumeration .1.3.6.1.4.1.52.4.1.1.7.3.2.1.4 |
psPowerAdminrw Enumeration .1.3.6.1.4.1.52.4.1.1.7.3.2.1.5 |
psPowerVoltagero INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.6 |
psPowerCurrentro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.7 |
psPowerLineFrequencyro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.8 |
psPowerMaxVoltagero INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.9 |
psPowerMinVoltagero INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.10 |
psPowerMaxPowerro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.11 |
bbuPower OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.4 |
termPower OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.5 |
termPowerStatusro Enumeration .1.3.6.1.4.1.52.4.1.1.7.5.1 |
termPowerVoltagero INTEGER .1.3.6.1.4.1.52.4.1.1.7.5.2 |
termPowerCurrentro INTEGER .1.3.6.1.4.1.52.4.1.1.7.5.3 |
termPowerModule1Statusro Enumeration .1.3.6.1.4.1.52.4.1.1.7.5.4 |
termPowerModule2Statusro Enumeration .1.3.6.1.4.1.52.4.1.1.7.5.5 |
CTRON-POWER-SUPPLY-MIB Technical Reference Overview
The CTRON-POWER-SUPPLY-MIB SNMP MIB module published by Cabletron defines 69 managed OID objects, including 54 scalar/column metrics, 5 SNMP tables, and 0 trap/notification events. Key tabular structures include chPowerTable, boardPowerSlotStatusTable, boardPowerSlotTable, psPowerSlotStatusTable, psPowerSlotTable.
Key OID Definitions in CTRON-POWER-SUPPLY-MIB
.1.3.6.1.4.1.52.4.1.1.7.1.8A list of power lines or busses on the chassis's backplane.
.1.3.6.1.4.1.52.4.1.1.7.2.1A list of networking modules installed in this chassis.
.1.3.6.1.4.1.52.4.1.1.7.2.2A list of networking modules and associated power lines installed in this chassis.
.1.3.6.1.4.1.52.4.1.1.7.3.1A list of AC & DC power supplies installed in this chassis.
.1.3.6.1.4.1.52.4.1.1.7.3.2A list of power supplies and associated power lines installed in this chassis.
.1.3.6.1.4.1.52.4.1.1.7.1.1This object reflects the overall status of the chassis's power supply in terms of how the power is being delivered to the chassis.
.1.3.6.1.4.1.52.4.1.1.7.1.2This object reflects the state of the main voltage rail within the chassis. The power on this rail may be delivered by AC supplies, DC supplies or battery supplies.
.1.3.6.1.4.1.52.4.1.1.7.1.3The voltage of the chassis's main voltage rail. This rail carries power to all the modules in the chassis. It has an allowable range of 40 volts to 60 volts DC. The value of this object is the actual voltage * 10.
.1.3.6.1.4.1.52.4.1.1.7.1.4The total power being supplied by the chassis's power supplies to the chassis. The value of this object is the actual watts.
.1.3.6.1.4.1.52.4.1.1.7.1.5The total load being presented by the chassis to the chassis's power supplies. The value of this object is the actual watts.
.1.3.6.1.4.1.52.4.1.1.7.1.6The maximum power that could de supplied by the chassis's power supplies to the chassis. The value of this object is the actual watts.
.1.3.6.1.4.1.52.4.1.1.7.1.7The maximum load that could be presented by the chassis to the chassis's power supplies. The value of this object is the actual watts.
.1.3.6.1.4.1.52.4.1.1.7.1.9This object reflects the state of the diag voltage rail within the chassis.
.1.3.6.1.4.1.52.4.1.1.7.1.10The voltage of the chassis's diag voltage rail. This rail carries power to all the modules in the chassis. It has an allowable range of 4.75 volts to 5.25 volts DC. The value of this object is the actual voltage * 10.
.1.3.6.1.4.1.52.4.1.1.7.5.1This object reflects the status of the chassis's termination voltage rail.
.1.3.6.1.4.1.52.4.1.1.7.5.2The voltage of the chassis's termination voltage rail. This rail carries power to INB terminator cards in the chassis. It has an allowalble range of 3.3 Volt + or - 5%.The value of this object is voltage * 100.
.1.3.6.1.4.1.52.4.1.1.7.5.3The current on the chassis's termination voltage rail. The value of this object is the actual amperage * 100. If this reading is not implemented then the value will be zero.
.1.3.6.1.4.1.52.4.1.1.7.5.4This object reflects the state of the INB termination module number 1. A value of normal(1) reflects that both busses are normal. A value of fault(4) reflects that both busses are in a fault condition.
.1.3.6.1.4.1.52.4.1.1.7.5.5This object reflects the state of the INB termination module number 2. A value of normal(1) reflects that both busses are normal. A value of fault(4) reflects that both busses are in a fault condition.
.1.3.6.1.4.1.52.4.1.1.7.1.8.1A slot entry containing objects for a particular module and associated power line.
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.1A unique value used to identify a particular power line on the chassis's backplane.
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.2The type of power. For example, a power line that supplies DC current at a nominal voltage of 40 to 57 volts or a power line that supplies AC current at a nominal volatge of 110v.
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.3The total power being supplied by the chassis's power supplies to the chassis on this power line. The value of this object is the actual watts.
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.4The total load being presented by the chassis to the chassis's power supplies on this power line. This value will be zero if unknown The value of this object is the actual watts.
More MIBs from Cabletron
Browse all CabletronMIBs →SNMP MIB module
Standard SNMP MIB module defining data structures for CTRON-SFCS-MIB.
Standard SNMP MIB module defining data structures for CABLETRON-TRAPS.
SNMP MIB module
Standard SNMP MIB module defining data structures for ADIC-SANMGR-PROXY-MIB.
The CTRON-AP3000-MIB module enables read-write SNMP configuration management for Enterasys AP3000 wireless access points under the Enterasys enterprise OID. It provides programmatic access to device-specific operational parameters and settings required for provisioning and maintaining the AP3000 hardware.