CTRON-POWER-SUPPLY-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
69
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
69 total| Object Name |
|---|
chPower OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.1 |
CTRON-MIB-NAMES Unknown .1.3.6.1.4.1.52.4.1.1.7.1 |
chPowerOperationalStatusThis object reflects the overall status of the chassis's
power supply in terms of how the power is being delivered
to the chassis.ro Enumeration .1.3.6.1.4.1.52.4.1.1.7.1.1 |
chPowerMainVoltageStatusThis object reflects the state of the main voltage
rail within the chassis. The power on this rail may
be delivered by AC supplies, DC supplies or battery
supplies.ro Enumeration .1.3.6.1.4.1.52.4.1.1.7.1.2 |
chPowerMainVoltageThe voltage of the chassis's main voltage rail. This rail
carries power to all the modules in the chassis. It has
an allowable range of 40 volts to 60 volts DC. The value
of this object is the actual voltage * 10.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.3 |
chPowerTotalSupplyThe total power being supplied by the chassis's power
supplies to the chassis. The value of this object is the
actual watts.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.4 |
chPowerTotalLoadThe total load being presented by the chassis to the
chassis's power supplies. The value of
this object is the actual watts.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.5 |
chPowerMaxSupplyThe maximum power that could de supplied by the chassis's power
supplies to the chassis. The value of this object is the
actual watts.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.6 |
chPowerMaxLoadThe maximum load that could be presented by the chassis to the
chassis's power supplies. The value of
this object is the actual watts.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.7 |
chPowerTableA list of power lines or busses on the chassis's backplane. SEQUENCE OF ChPowerEntry .1.3.6.1.4.1.52.4.1.1.7.1.8 |
chPowerEntryA slot entry containing objects for a particular
module and associated power line. ChPowerEntry .1.3.6.1.4.1.52.4.1.1.7.1.8.1 |
chPowerLineIDA unique value used to identify a particular power line on
the chassis's backplane.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.8.1.1 |
chPowerLineTypeThe type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a
power line that supplies AC current at a nominal volatge of
110v.ro OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.1.8.1.2 |
chPowerLineTotalSupplyThe total power being supplied by the chassis's power
supplies to the chassis on this power line. The value
of this object is the actual watts.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.8.1.3 |
chPowerLineTotalLoadThe total load being presented by the chassis to the
chassis's power supplies on this power line. This value
will be zero if unknown The value of this object is the
actual watts.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.8.1.4 |
chPowerLineMaxSupplyThe maximum power that could de supplied by the chassis's power
supplies to the chassison this power line. The value of
this object is the actual watts.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.8.1.5 |
chPowerLineMaxLoadThe maximum load that could be presented by the chassis to the
chassis's power supplies on this power line. The value of
this object is the actual watts.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.8.1.6 |
chPowerDiagVoltageStatusThis object reflects the state of the diag voltage
rail within the chassis.ro Enumeration .1.3.6.1.4.1.52.4.1.1.7.1.9 |
chPowerDiagVoltageThe voltage of the chassis's diag voltage rail. This rail
carries power to all the modules in the chassis. It has
an allowable range of 4.75 volts to 5.25 volts DC. The value
of this object is the actual voltage * 10.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.1.10 |
boardPower OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.2 |
boardPowerSlotStatusTableA list of networking modules installed in this chassis. SEQUENCE OF BoardPowerSlotStatusEntry .1.3.6.1.4.1.52.4.1.1.7.2.1 |
boardPowerSlotStatusEntryA slot entry containing objects for a particular
module. BoardPowerSlotStatusEntry .1.3.6.1.4.1.52.4.1.1.7.2.1.1 |
boardPowerSlotStatusIDThe slot number of a chassis slot in which this board is
installed. This object is similiar to chSlotID in the
Chassis MIB.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.1.1.1 |
boardPowerOperationalStatusThis object reflects the status of the module's
DC-DC converter power supply.ro Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.1.1.2 |
boardPowerAdminStatusThis object controls the operation of the module's
DC-DC power supply. If the value 3 is written to
this object then the value of the object will be
set to 1 after the reset is performed.rw Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.1.1.3 |
boardPowerLocalAdminStatusThis object controls the operation of the module's
front panel button. In local mode this button may
be used to locally control the operation of the
DC-DC converter, i.e. power on, power off and
reset. In secure mode a request the state of the
front panel button is reflected in the object
boardPowerOperationalStatus. In secure mode
the front panel button has no effect locally.rw Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.1.1.4 |
boardPowerLocalStatusThis object reflects the state of the module's front
panel button.ro Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.1.1.5 |
boardPowerShutdownAdminThis object controls whether or not the module should
auto power down due to an fault condition.rw Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.1.1.6 |
boardPowerPriorityThe module's power-up and power down priority. This is a
value of 1 to 14 and is used to decide which modules are
allowed to power on in the event that power demand of the
chassis is greater than the total power supply. The default
value is 14, highest priority. When two modules have equal
priority then the module in the lowest slot wins.rw INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.1.1.7 |
boardPowerMaxInputPowerThe maximum input power that this module is allowed
to consume. The value of this object is actual
watts.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.1.1.8 |
boardPowerManagementModule power management status.rw Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.1.1.9 |
boardPowerSlotTableA list of networking modules and associated power lines
installed in this chassis. SEQUENCE OF BoardPowerSlotEntry .1.3.6.1.4.1.52.4.1.1.7.2.2 |
boardPowerSlotEntryA slot entry containing objects for a particular
module and associated power line. BoardPowerSlotEntry .1.3.6.1.4.1.52.4.1.1.7.2.2.1 |
boardPowerSlotIDThe slot number of a chassis slot in which this board is
installed. This object is similiar to chSlotID in the
Chassis MIB.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.1 |
boardPowerIDA unique value used to identify a particular power line.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.2 |
boardPowerTypeThe type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a
power line that supplies AC current at a nominal volatge of
110v.ro OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.3 |
boardPowerStatusThis object reflects the status of this power line.ro Enumeration .1.3.6.1.4.1.52.4.1.1.7.2.2.1.4 |
boardPowerVoltageThe voltage reading for the power line. The value of this
object is actual voltage * 100.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.5 |
boardPowerCurrentThe current reading for the power line. The value of this
object is the actual amperage * 100. If this reading is not
implemented then value will be zero.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.6 |
boardPowerMaxVoltageThe maximum voltage for this power line. If the voltage
reading for this power line is greater than this value
then the power line is considered to be in an overvolatge
condition. The value of this object is in voltage * 100.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.7 |
boardPowerMinVoltageThe minimum voltage for this power line. If the voltage
reading for this power line is less than this value
then the power line is considered to be in an undervolatge
condition. The value of this object is voltage * 100.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.8 |
boardPowerMaxPowerThe maximum power for this power line. If the power calculated
for this power line is greater than this value then the
power line is considered to be in an overload condition.
The value of this object is in watts.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.2.2.1.9 |
psPower OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.3 |
psPowerSlotStatusTableA list of AC & DC power supplies installed in this chassis. SEQUENCE OF PsPowerSlotStatusEntry .1.3.6.1.4.1.52.4.1.1.7.3.1 |
psPowerSlotStatusEntryA slot entry containing objects for a particular
power supply. PsPowerSlotStatusEntry .1.3.6.1.4.1.52.4.1.1.7.3.1.1 |
psPowerSlotStatusIDThe slot number of a chassis slot in which this AC power
supply is installed. This object is similiar
to chSlotID in the Chassis MIB.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.1.1.1 |
psPowerOperationalStatusThis object reflects the status of the module's
DC-DC converter power supply.ro Enumeration .1.3.6.1.4.1.52.4.1.1.7.3.1.1.2 |
psPowerAdminStatusThis object controls the operation of power supply.rw Enumeration .1.3.6.1.4.1.52.4.1.1.7.3.1.1.3 |
psPowerMaxOutputPowerThe maximum power that this power supply is allowed
to ouput. The value of this object is watts.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.1.1.4 |
psPowerSlotTableA list of power supplies and associated power lines
installed in this chassis. SEQUENCE OF PsPowerSlotEntry .1.3.6.1.4.1.52.4.1.1.7.3.2 |
psPowerSlotEntryA slot entry containing objects for a particular
power line on a particular power supply. PsPowerSlotEntry .1.3.6.1.4.1.52.4.1.1.7.3.2.1 |
psPowerSlotIDThe slot number of a chassis slot in which this Power
supply is installed. This object is similiar to
chSlotID in the Chassis MIB.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.1 |
psPowerIDA unique value used to identify a particular power line.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.2 |
psPowerTypeThe type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a
power line that supplies AC current at a nominal volatge of
110v.ro OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.3 |
psPowerStatusThis object reflects the status of the power line.ro Enumeration .1.3.6.1.4.1.52.4.1.1.7.3.2.1.4 |
psPowerAdminThis object controls the operation of power supply.rw Enumeration .1.3.6.1.4.1.52.4.1.1.7.3.2.1.5 |
psPowerVoltageThe voltage reading for the power line. The value of this
object is the actual voltage * 100.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.6 |
psPowerCurrentThe current reading for the power line. The value of this
object is amperage * 100. If this reading is not implemented
then value will be zero.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.7 |
psPowerLineFrequencyThe line frequency for the power line. The value of this
object is the actual frequency in Hertz * 10. If this
reading is not implemented then value will be zero.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.8 |
psPowerMaxVoltageThe maximum voltage for this power line. If the voltage
reading for this power line is greater than this value
then the power line is considered to be in an over volatge
condition. The value of this object is voltage * 100.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.9 |
psPowerMinVoltageThe minimum voltage for this power line. If the voltage
reading for this power line is greater than this value
then the power line is considered to be in an over volatge
condition. The value of this object is voltage * 100.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.10 |
psPowerMaxPowerThe maximum power for this power line. If the power calculated
for this power line is greater than this value then the
power line is considered to be in an overload condition.
The value of this object is watts.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.3.2.1.11 |
bbuPower OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.4 |
termPower OBJECT IDENTIFIER .1.3.6.1.4.1.52.4.1.1.7.5 |
termPowerStatusThis object reflects the status of the chassis's termination
voltage rail.ro Enumeration .1.3.6.1.4.1.52.4.1.1.7.5.1 |
termPowerVoltageThe voltage of the chassis's termination voltage rail.
This rail carries power to INB terminator cards in the
chassis. It has an allowalble range of 3.3 Volt + or -
5%.The value of this object is voltage * 100.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.5.2 |
termPowerCurrentThe current on the chassis's termination voltage rail.
The value of this object is the actual amperage * 100.
If this reading is not implemented then the value will
be zero.ro INTEGER .1.3.6.1.4.1.52.4.1.1.7.5.3 |
termPowerModule1StatusThis object reflects the state of the INB termination
module number 1. A value of normal(1) reflects that
both busses are normal. A value of fault(4) reflects
that both busses are in a fault condition.ro Enumeration .1.3.6.1.4.1.52.4.1.1.7.5.4 |
termPowerModule2StatusThis object reflects the state of the INB termination
module number 2. A value of normal(1) reflects that
both busses are normal. A value of fault(4) reflects
that both busses are in a fault condition.ro Enumeration .1.3.6.1.4.1.52.4.1.1.7.5.5 |